Loading...
HomeMy WebLinkAboutREVISIONS��V) � \,ob %�-- Q.FFICE USE ONLY: DATE FILED: \ I a.b REVISION FEE: -I • a d PERMIT# RECEIPT # 191749 PLANNING && DEVELOPMENT sERvjcEsrZECElVED BUILDING & CODE REGULATION DW SION 2300 VIRGINIA AVENUE APR 01 2020 FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 ST. Lucie County, Permitting APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 2Z?O SWeE-r w]4Te-R SCANNED 2. DETAILED DESCRIPTION OF PROJECT BY REVISIONS: St. Lucie Countv `Dlecr- Gmt cold=lGU2RT)W CApibiGED„ RE --DES IGue� E rJc.LoSue t To gCCcFV A0'D;,/rr . 3. 4. U CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: G rz c CITY: Po,tr Sr. Lei PHONE (DAYTIME): '742 OWNEWBUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: ARCHITECT/ENGINEER INFORMATION: ° NAME: DO K7 ADDRESS: pb. 134 CITY: A M P A PHONE (DAYTIME): '9 Revised 0722/2014 C ST. LUCIE COUNTY CERT. #: scpce{tJ Co.:r0C. 7r yr?63 STATE: r� ZIP: 3416,11 FAX: 'T7, ZIP: FAX: STATE: FL ZIP: FAX: NEI ,lit o � 0 r 0 D� ,DST r0 W9I >. F l,,noD§cz 0 rp m 6W3 N� o m9 c r op � v RECEIVED APR 0 1 2020 R ST. Lucie ounty, Permitting 1 �\ r 3c FM 0 r � INNED By ie County REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC (9) 812x$' S.M.S. TO WALL MEMBERS I^ l (❑R) 2" (MAX.)(4)x JS.M.S. 2x2 A 2x2xlg" ANGLE O EYE BOLT 2U—BOLTED TO ! HEADER W/ DOUBLE 3HER & NUT EACH SIDE, SAUG_ AGAINST ANGLE o \ o e e e o S.M.B. e (SEE PLAN MR SDq e (9) /12x3/4' &M.S., EACH SIDE (EACH END. TYP.) O ill 2.7 MIN. BEAM BRACE -� e (NorCH TOP FUMGEs) KNEE BRACE DETAIL &MS. (SEE PLN1 FOR SIZE) JJ CONCRETE (❑R) Q) - W x r CONCRETE SCREW ANCHOR (TYP.) '.1 (2) flOx4' FAME RAIL Bosses 1xNfim BY Y LDNG ANG1E. EACH SIDE ".) (4) 1144' SNS.. 2 52EW5 EACH LEG (TYP.) HOLLOW POST — USE /1'px S.M.S. Y 24' O.C. - TD7NNE To W O.B. TO 2x3. U4 O.B. FASTENED TO COWMN/POE W/(2) /10x11W' S.M.S. INTO SCREW BOSSE A (EACH END. TIT 2x PURUN (WY BE SLOPED OR FLAT) BEAM STITCHING SCREWS (SEE TABLE) B 24. D.C. SPLICE PLATE (EACH SIDE OF BEAR) ` A 5052-H32 ALLOY OR EQUAL, VW THICKNESS �g Jry (1.Ipl 414x�' SCREVS Y R LINE LINE SCREWS PLATE 64pD Ole le BEAM 'A' 'B'6'C' TOTAL WIDTH 2x4 3 2 24 12, VYLE toSP1' 2x5 3 3 32 14' 2x6 4 3 40 14' VHE�PN `ss•x�i ( i2x7!_ : 'S•.':. 'e`Sfi. 4e13 f' PURUN FASTENED TO COLUMN/P WON (4) j12x1' S.MS. (EACH L USING X' WICK FIAT EAR BENT ROOF BEAM j2xqKHW)j 6 1 7 1 88 IS- I KL CONNECTION DETAIL xlow 7 zm y ss s )B• (3) 1124- S.M.S.. EACH LEG AND MIN. (4) /Wx3' LONG S.M.S. INTO (71 P. 9 /CREW' B.M.S. CHANNEL 10 BFAV� YREW 80556 0 0 ALTERNATIVE) Wj+fl( SCREW TOTAL BfAJI STRGIWM' O.C. TOP AND BOTTOM OFSMB 2=J.G.G�o�� „-� sEE TABLE FOR sz6s) q''*ng• VAIN (2)-BI4xl IMIY,' S.M3 O 24' D.C.— INNECT TO 1x2 D.B. TO 2x& (9) /12a' S.N.S. EACH SIDE. (O(F B/DW (TYP ) OR Dd BEN( FDR 2x5 EACH NDTo 2x5 BEAM DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED j u'azo �l ST. JCIEO BOW lxlxiW' BY 3' LONG ANGLE, EACH SIDE (M.) C 0 TJ MED REGEWNG CHANNEL NATLFAL THKKNF55) IN'A x 3' LG. (3) 112,,% S.M.S., EACH lEG (a)�) Z W SCANNED w - z BY C O 0 St. Lucie County � a PURLIN TO ROOF BEAM EE CONNECTION DETAIL LU Co a >- U 0 DRAWN BY: DYK I CHECKED BY: DYK 1W' HIM. 3 W MAX C-C SPACING GF FASTENERS (TYP.) DSTNE (TYP EDGE OR FLAT DATE: SIZE) DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KICTES, LLC 1267 O 39 L3ma3679 1,44-10 NNECTION DE Irvec ling No. - 060811 SHEET 1OF3 PURLIN SUPPORT-sT_-' -'0r�'--- COWjN/POST9- Y' ANGV- EACH SIDE (TYP.) 2x1/B' x 2' ANGLE S.M.S. WITH MIN. 3§' CD pN <€:W2 * / (1) /12x3/4' S.M.S EDGE DISTANCE W/2 EMBED INTO W/` EMBEDMENT INTO �•► _ (EACH SIDE) ll OyO. �§'0 CONCRETE ANCHOR STRU O CONCRETE I'W O.B. SO E, PL EMBEDMENT- O O W/sr MB STRUCTURAL RAL CONCRETE (EACH SIDE) 3- SE,EE..'PTAN FOR SIZE 14 O.B. FASTENEO TO CORNE SECTION WIN /14xNQ S.M.S.1 24' O.C. 21219' GlE 2' LONG (EACH W/ • Y' ANGLE, EACH SIDE (M.) %'0 CONCRETE ANCHOR W/2%' EMBEDMENT INTO STRUCTURAL CONCRETE (IYP.. SEE NOTE 10) �1'x2' O.B. SOLE PLATE 9' EDGE OF CONCRETE i R _ _ 3- MIN. PLAN VIEW 1' (TYP.) TAOM POST B' PLAN VIEW 2'x PURUN L$ 0x2Y� CONCRETE (BEAM BE FLAT SCREW ANCHOR O 24' O.C. OR SLAPEL AND 9' FROM POST (TYP.)` 4 ,., COWMN/POST •l( �taZ O.B. SOLE PUTE- PLAN - I .-venx�c (TYP.) 2 Ns BEAM SUPP( COLUMN/PO 2.Nl/a' x W/ (4) 112 (EACH SIDE) POST BEAM WITH ONE (1) Ya' BOLT. WRH FENDER WA ATTACHED TO BEAM OR DMODNAL BRACING SHA ATTACHED TO ROOF PU 2.2x0.093 BRACE (sEE PUN) COLUMN MAX. THICK BRICK PAVERS IN MORTAR ON TOP OF FOOUM 1 PLATE 0 B SOLE II Z ( N Y' Ox5' CONCRETE SCREWS O 24- O.C. 2X- MIN. CONC. (TYP.), 1)y' CONC. EMBEDMENT (MIN.) EMBEDMENT (TIP.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SUB W?W.M. OR500 PSI� FIBEMIN.R REINFORCED [POLYPROPYLQIE FIBER - 1.5 POUND (MIN.)PER C.Y.] .. - 4 . e4 a UNDISTURBED SOIL OR COMPACTED CRUSHED UMEROCI( (90% PROCTOR) - I MIN. (1)-e5 REBAR CONIINUOUS, SPUCE MUSE OVERLAP 20' MIN. 3' COVER (TYP.) Ix3 O.B. FASTENED TO CORNER SECTION WITH 81Ox2- S.M.S. W/ %- CIA. WASHCR O 18- O.C. (2)-R14 RAIL AND (2)- THE CORNER POST L-1x2 O.B. TOP FRAME CORNER POST lx O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-Ml ISSUED 2500 PSI MIN. CONCRETE STRENGTH 4 . REVIEWED FOR MATE CODE COMPLIANCE S , LUSFiE COUNTY i I I 4. A UNDISTURBED SOIL/SAND ��� W I G (1)—#5 REBAR, CONTINUOUS L) I 3" MIN. GONG. COVER, 36" MIN. — W I I I LAP SPLICE OOf U O TI C 12" MIN! J U Z W MIN. CONTINUOUS PERIMETER FOOTING w (4) d12.Y 2% PURUN BEAM MAY BE FLAT OR SLOPE[ ((2) 810x2): TP. EACH ((TH P8 EACH c Z Of o a = C0 J Z U W U ALTERNATE (1) 1 WW 2x1W ANGLE BRACE DRAWN BY: DYK 25H x%m ANGLE (BRACE) W/ CHECKED BY: DYK (4) Al2WW SS.M.S. O EACH SCALE; ASSHOWN PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 i ANGLE 2' LONG ON RSIDEW/(4) g12xY' S.M.S. LED (BEAM 4: BRACE) TRACE PLAN) ALTERNATE (2) 2x3 BRACE DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KI CATES, LLC 7 vlenolo39 Tampa, FL 33679 `i Zo FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 2OF3 2x PURLIN (MAYBE SLOPED OR FLAT)'„ D ❑ KI M " L ASSOCIATES, LLC �. 1's' 0 X 4' LONG WOOD LAG SCREW OR 'e y4 0 xIN LONG MASONRY ANCHORS ' @ 24' OI&MAx. •�� HOST STRUCTURE '• (MASONRY OR WOOD) 2x24" ANGLE, EACH SIDE '( (TYP.) (4) #14xl" S.M.S., (2) SCREW EACH LEG (TYP.) F EDGE BEAM TO HOST ST z _ CONNECTION DETAIL REVIEWED FOR CODE COMPLIANI ST. LUCIE COUNT ROCC General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of AD 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner lat his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy, for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #10A/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum 141-#10x2" per connection unless shown otherwise. B. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. 1-1022 Low Carbon Steel SMS & Self -Drilling ITEM Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 1/16" W #12 0.219 14. 1/11" #14 (1/4") 0.250 Y2" 5/6" 9. Structure has been designed to meet the V Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, Vult, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs). Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Aluminum roof pans shall be of aluminum alloy 3105-H14 or 3105-H28. Composite panel skins shall be of aluminum alloy 3105-H15 or 3105-H25. CONSULTING STRUCTURAL ENGINEERS PO Bar 10039 Tampa, FL 33679 Tel: (813) 374-Ml ISSUED 0 0 C W o 0 O (D J 42 U Z W w • r_ c Z W aO 1- U) J Z U 0 W rn CL} LU U 0 F DRAWN BY: DYK CHECKED BV: DYK SCALE: AS SHOWN DO YEON KIM, P.E. FLA REG. NUMBER 49497 DO KIM & AS TIAT sES, LLC 87 a pa, 679 1.7 %[. z° 12. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. I Drawing No. - 060811 1 SHEET 3OF3