Loading...
HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: DATE FILED* REVISIONFEE: r1S'00 LOCATION/SITE ADDRESS: PERMIT # RECEIPT # / ¢/0 -0,S03 PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION SCANNED 2300 VIRGINIA AVENUE BY FORT PIERCE, FL 34982-5652 (772) 462-1553 St. Lucie County APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: e ��r�Tirse rrta Q i 4�l s G6!-A/4 4 x b CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: q 719 BUSINESS NAME: Vi 3 QUALIFIERS NAME: Si EI CITY: I PHONE OWNER/BUILDER INFORMATION: NAME: CITY: PHONE(DA ARCHITECT/ENGINEER INFORMATION: FAX: sLccc / REVISluk""N dRevise06130117 ZIP: General Notes A. CONCRETE & FOUNDATION DESIGN: L ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, 93 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING+/- 1%- ASTM C260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 1 L IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: L CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR 2.ALL MORTAR SHALL BE OF TYPE M OR S. TALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 318". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE HICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. THE FLORIDA BUILDING CODE 6th EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN # 10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING # 12 SPACING MAY BE 24" ON CENTER 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. Z. I"X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & 9IOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON,REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4, ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5, ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER- 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. I FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 _ CURRENT ASCE7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16, 20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP -TYPICAL 2. SIM -SIMILAR I BON - UNLESS OTHERWISE NOTED 4. CONT - CONTINUOUS 5. VIE-- VERIFY IN FIELD G. RESPONSIBILITY: I. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR- 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED. BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER S. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: L ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION R 4501.17IN ITS ENTIRETY. I DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR- 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. SCREENING MATERIAL SHALL BE I8X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2"X0.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 31 PSF SOLID ROOF (SCREEN WALL): 25 PSF COMPONENTS AND CLADDING LOAD: N/A SCANNED BY St. Lucie County ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 150 MPH Thomas L. Hanson P. 116 MPH FLORIDA LICENSE: 38654 B Myron Max Neal P.E. FLORIDA LICENSE:86663 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD. 300 Ib. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. EXISTING SLAB AND OR FOOTING MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE* N/A 10. SOLID ROOF TYPE; 3"X48"X0.024" ELITE EPS COMPOSITE PANEL ROOF 11b FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561.R-4. ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2:-------------------------------------2„ x 2" x 0.044„ 2 x 3:----------2" x 3" x 0.050" 2 x 4---=------------------------------- ----- 2" x 4" x 0.050" 2 x 5:---------------------------------------2" x 5" x 0.050„ 3 x 3:--------------------------------------3" x 3" x 0.125„ OPEN BACK SECTIONS 1 x 2:-------- --------------------------- 1" x 2" x 0.040„ 1 x 3----------------------------------------V x 3" x 0.045" SNAP SECTIONS 2 x 2 SMS:----------------------------------2" x 2" x 0.045" 2 x 3 SMS- ---------------------------------2" x 3" x 0.072" 2 x 4 SMS: -------------------------------- 2" x 4" x 0.04S" 3 x 3 SMS:--------------------------------- 3" x 3" x 0.090" SELF MATING (SMB 2 x 4 SMB:--------------------- 2" x 4" x 0.044" x 0.100" 2 x S SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMBr--------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMBr--------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2---------------------------------------2" x 2" x 0.090„ .+ t C�10 - oSo 3 Joel Falardeau P.E. 'FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.tbcplans.com C.O.A.429054 DATE: 10/16/2019 DRAWN BY: BM I REVISION: I DATE: 1110 1 I 01/14/2020 I RO 2 IR03 I RO 4 Job# 19_1011_214 PROJECT ADDRESS: KELLY 4807 PALMETTO DR FORT PIERCE, FL 34982 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 i1 = I 3" ALUMINUM -1 o - POLY ROOF c0 I T -_2x7 SMB -- ATTACHED TO FASCIA I I If —� ro =o 3" ALUMINUM POLY ROOF ro rn O 1 o I - s �l/ rn o x M W S-3 to _ _ 2x6 SMB _ s i _ _ 2x6 SMB _ _ X to 3x3x.093 2x7 SMB 2x6 SMB 2x6 SMB r7 r7 r7 O 0 O o 0 X X X X X 7 j I I I I it 3x3x.093 U t t rwil s' a. David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 oel Falardeau P.E. LORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineerir Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-w .fbcplans.com C.OA. #29054 DATE: 10/16/2019 DRAWN BY: BM REVISION: DATE: RO 1 01/14/2020 RO 2 RO 3 RO 4 JECT ADDRESS: Y PALMETTO DR PIERCE, FL 34982 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 (1)#S REBAR CONTINUOUS W/ 25" OVERLAP AT ALL JOINTS ON 3" CHAIRS & CENTERED -TYPE II MONOLITHIC SLAB MODERATE SLOPE FTG SLOPE: 2":12" - 3":12" NOTES FOR ALL FOUNDATION TYPES: 1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING OF CONCRETE. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO POURING OF ANY CONCRETE. 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. K TYPE II MONOLITHIC SLAB FOOTING S-3 (4)-3/8" 000NCRETE N OTE: MINIMUM EMBEDMENT OF SCREW WITH 2-3/4" ANCHORS INTO CONCRETE FOOTING SHALL EMBEDMENT (MIN BOG -- BE 2-3/4' AT ALL POST LOCATIONS. ALL DISTANCE=3" SCREW LENGTHS AT POST CONNECTIONS MIN SPACING 2") SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. (3) -1/4" 0 MACHINE BOLTS WITH WASHERS TOP VIEW 3"X3"POST (MIN. EDGE DISTANCE = 3/4" ' (SEE SHEET S-2 FOR MIN. SPACING=3/4 SIZE) OR (4) #14X 3/4' SMS 2"x2"x 0.125" ANGLE (EXTERNAL EA SIDE OR INTERNAL) OR 0.125" (4)-3/8" 000NCRETE RECEIVING CHANNEL SCREW WITH 2-3/4' - I 1" x 2" OPEN BACKANCHORED EMBEDMENT (MIN BUG TO CONCRETE w/ 1/4" X 3- DISTANCE=3" 1/Z"MASONRYANCHOR-6" MIN SPACING 2") 6'--..( MAX EACH SIDE OF POST AND 1 24" O.C. MAX G 4 2" (min) FRONT VIEW NOTE: CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON3/8" 0 LOT SCREW ANCHORS, OTHER SIZE OR TYPE OF ANCHORS SHALL NOT BE USED. CT1 3"X3"POST CONNECTION DETAIL S'3 SCALE: NTS 2" x —END BEAM (SEE SHEET 3-2 FOR SIZE) EXISTING MASONRY WALLGROUTED SOLID — — @ CONNECTION 1/4" p X 2-3/4" EMBI MASONRYSCREW3" END & @ 24" D.C. 2" x_"END BEAM ATTACHED TO 1"x2' OPEN BACK W/ (4) #10 x 2" 1"X2" OPEN BACK THRU SCREW BOSS NOTE: WHEN ATTACHING TO WOOD STRUCTURES, WOOD LAG SCREW , ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT OF MASONRY ANCHOR SCREWS. S2 END BEAM TO HOST CT TA, 1 S'3 SCALE:Ila IL _"X 4"X.125"ANGLE FOR ALL NON -PLUMB OR SQUARE FASCIA SHALL BE USED WITH SUPER GUTTER. OSTSTRUCTURE BREAK FORM HEADER OR RECEIVING CHANNEL #10 SMS AT EACH RISER F—FOR PAN OR#10 SMS@ 8" O.C. FOR COMPOSITE PANEL i--SOLID ROOF \#10 SMS @ B" O.C. ' 1-1/4"J (MIN) FOR COMPOSITE PANEL (2) 910 SCREWS PER 12" WIDTH CONNECTING PAN TO HEADER (BOTTOM OR BACK OF PAN) 2) #10 X 2" SCREWS PER 12" WIDTH CONNECTING HEADER OR CHANNEL TO FASCIA. 51 ROOF PANEL TO FASCIA CONNECTION DETAILS S_3 SCALE:NTS 7 OPTIONAL: 1"X2",PEN BACKATTACHED T� HOST W/ (1) 1/4"0 CONCRETE SCREW ORLA (THIN 6" OFBEAIH&@ 4"O.C.MAX ENBEAMS (B) -1/4" 0 CONCRETE SCREW W/ 1-1/2" EMBEDMENT INTO MASONRY (1-1/2" MIN. SPACING (6)- #14 X 3/4"SMS ATTACHING ANGLE TO BEAM EACH SIDE IV MIN. SPACING) 0 0 0 (B)-1/4"0MSCREWS INTO WOOD (1"I- MIN SPACING) (TYP 2 LOCATIONS) BEAM "B" NOTES: 2X4 1 1. THE MINIMUM EDGE DISTANCE IS 3" FOR MASONRY 2x5 2 STRUCTURES. 2. IF A RECEIVING CHANNEL IS 2x6 2 USED, USE TWICE THE NUMBER 2X7 3 B" ANCHORS INTO THE HOST STRUCTURE. ALL MINIMUM 2x8 3 SPACING SHALL BE APPLICABLE. 2x9 3 A BEAM TO HOST TOi 2x10 4 S-3 \ SLOPED OR FLAT `ROOF BEAM (SEE SHEET S-2 FOR SIZE) \_2"X2"X 0.125"ANGLE EA. SIDE OF BEAM EXISTING HOST STRUCTURE (CONCRBFE, GROUT FILLED CMU OR WOOD) �,xtl:evrS,z't ®�® � ID E A ® a °°U ° .` �5��1 6 U1 L11 s 0 .`� °' LC/ o A n CD ° v® A ' O ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 AbbottStation Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsfte-www.fbcplans.com C.O.A.-429054 10/16/2019 Y: BM REVISION'.~ DATE: RO 1 01/14/2020 RO 2 { RO 3 RO 4 Job# 19°1011_214 PROTECT ADDRESS: PALMETTO DR PIERCE, FL 34982 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3