This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: NichiPr oducts"m Fiber -Cement Siding
APPROVAL DOCUMENT: Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and
Drawing No. ITS N2090403, titled "NichiTanel", sheets 1 and 2 of 2, both dated 10/0512018, prepared by
Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E., bearing the Miami -Dade County Product
Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County
Product Control Section.
AVIISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA # 18-0815.06 and consists of this page 1 and evidence pages E-1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 19-0328.02
Expiration Date: July 22, 2024
Approval Date: May 23, 2019
051
r 3/�v l Page l
Nichiha USA, Inc.
NOTICE OF ACCEPTANCE: . EVIDENCE SUBMITTED
1. Evidence submitted under previous NOA'S—
A. DRAWINGS "Submitted under NOA # 15-1102.141,
1. Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and Drawing No. ITS
N2090403, titled "NichiPanel", sheets 1 and 2 of 2, both dated 03/16/2009, prepared by
Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E. on 10/13/2015.
B. TESTS "Submitted underNOA # 09-051L01"
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram ofNichiProducts Fiber -Cement
Panels, prepared by Intertek Testing Services NA LTD, Report No. 3145127COQ-004A,
dated 08/07/08, signed and sealed by Rick Curkeet, P.E.
2. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram ofNichiBoards and EcoPlanks,
prepared by Intertek Testing Services NA LTD, Report No. 3145127COQ-004B, dated
10/24/08, signed and sealed by Rick Curkeet, P.E.
3. Test report on Standard Specification for Flat Non -Asbestos Fiber -Cement Sheets of
NichiProducts Fiber -Cement Panels, per ASTM C1186-07, prepared by Intertek
Testing Services NA LTD, Report No. 3145123COQ-005, dated 05/20/08, with a
revision dated 02/02109, signed and sealed by Rick Curkeet, P.E.
4. Test report on Surface Burning Characteristics of NichiPanel Fiber -Cement Panels,
per ASTM E84-08, prepared by Intertek Testing Services NA LTD, Report No.
3145123COQ-006, dated 06/25/08, with a revision dated 04/03/09, signed and sealed
by Rick Curkeet, P.E.
5. Test report on Standard Test Method for Behavior of Materials in a Vertical Tube
Furnace at 750°C ofNichiha M series unprimed cementitious, per ASTM E136-99,
prepared by Intertek Testing Services NA LTD, Report No. 3105885COQ-002, dated
10/26/06, with a revision dated 03130/09, signed and sealed by Rick Curkeet, P.E.
C. CALCULATIONS "Submitted under NOA # 14-0715.03"
1. Anchor calculations prepared by Progressive Engineering, Inc., dated
10/22/2014, signed and sealed by Carl D. Fussner, P.E.
"Submitted under NOA # 09-0511.01"
2. Anchor analyses prepared by Category 5 Engineering Services, Inc., dated
04103/2009, signed and sealed by Emma T. Mellinger, P.E.
OS r3 2015.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No.19-0328.02
Expiration Date: July 22, 2024
Approval Date: May 23, 2019
E-1
Nichiha USA, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # 15-1102.14"
1. Drawing No. ITS N1090403 and ITS N2090403 statements of code conformance to the 51
edition (2014) FBC issued by Nichiha USA, Inc, dated 03/16/2009, signed and sealed by Carl
D. Fussner, P.E. on 10/13/2015.
2. Statement letter of no financial interest issued by Progressive Engineering, Inc., dated
10/13/2015, signed and sealed by Carl D. Fussner, P.E_
2. Evidence submitted under NOA # 18-0815.06
A. DRAWINGS
1. Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and Drawing
No. ITS N2090403, titled "NichiPanel", sheets 1 and 2 of 2, both dated 10/65/2018,
prepared by Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 6h edition (2017) FBC issued by PEI
Engineering Services, Inc, dated 02/22/2018, signed and sealed by Carl D. Fussner,
P.E. ^
oS i3�iot9
Carlos M Utrera, P.E.
Product Control Examiner
NOA No.19-0328.02
Expiration Date: duly 22, 2024
Approval Date: May 23, 2019
E-2
B° t
olc Sl
rn
12' Pe
(
1:
I" Panels Shown / 51W Panels Shown
1�1�1
�I�IrI
�Irl�l
1�Ifi1�1
II�I�1�1
I1�1�1�1
sl�l�ll�l
.. r r
1 •
;
1010a!
r r
Mimi"
, .
PRODUCT REVISED /
as complyln with the Florida
Building Code
NOA=No. 1 B-0B16.06
Expiration Date 0712212019
By
Miami-130d6 Product Control
lax
° a/o Spacing
rryp•)
5t Panel Height
(TYp•)
1�Ovedap
ITmJ
Nich[Board
Fiber Cement Siding
DESCRIPTION and SPECIFICATION NIchlBoard lap siding
material Is a non -asbestos fiber cement product tested In
accordance with ASTM C.1185 & ASTM C.1188 Type A
mssUog the raqulremeats of the Florida Building Code (HVHZ).
Boards are available In a variety of widths within the maximum
and minimum dimandons specified below.
Plank Dimensions
Width
Length
Thickness
5Y,°MIM
12'
!ie
12° Max.
12'
pia
Design Pressure Rating .126 put
LIMITATIONS
1. All Installation shall be done In accordance
with this Notice of Acceptance, the
manufacturer's Installation recommendations,
and the applicable sections of the Florida
Building Code Including High Velocity
Hurricane Zone whore Required.
2. Wood studs and plywood sheathing
supporting MchlBoard and EmPlank siding
shell conform to the Florida Building Coda
(Indudhng the HVHZ where required), and the
requirements of this Notice of Acceptance
(See Note Shoat 2).
3. Siding Installed as specified herein shag be
dsssftled.as Large Missile Impact Realstent
OCT 0 5 2010 c
No 171 B07
STATE OF
NICHIHA USA, INC.
5485 E. Jot=Crouse. JOMe C=k. Gk 30DO
PRODUCT REVISED
an comPlyrn® with the Florida
Building Code
NOA-No. 18-0815.08
Expiration D to 07/22/2019
By
�
Miami- ad Product Control
NICHIBOARD SIDING INSTALLATION
• The boards shall he applied horizontally commencing from the
bottom course of the wall.
• Each successive course shall ovedap the prior course by i Ya".
. Any vertical Joints shall be over framing members, with
fasteners either side of the Joint.
• The planks shall be Installed over V APA rated extedo"rade
plywood (SG = 0.50 min.) supported by 2' x 4' minimum wood
—1,11ohl6oard slang
studs spaced a maximum of 16" o.c.
-woauarvaa.h.w 9.id.r
The siding shell be fastened through over -lapping planks wlth
edx2VCommw Nag@
Bd x 2 Ye long common nells over wood studs.
s Ye da vadwM, a, olo
A row of fasteners shall be placed In the ovedap of each
2- M"l.gy. YP ut",
2• diet ads• 4' Mh,a.
I
course, spaced 6' o/c In the horizontal direction.
P
• Successive rows of fasteners shell be spaced not more then 5
%' o/c. (boards greater than 6 %' In width shag require an
%• Plywood shoamng-
additional row of fasteners In the center of the plank).
Faskamd to Saida
car
A distance of between a/a and 2' from the edges shell always
be observed.
PRODUCT RENEWED
as complying with the Florida
Building Coda
NOA-tin. 19-0328.02
Expiration DOAP0712212024
By
MIamF-Da o Produ—77
ct Control
PLYWOOD SHEATHING NOTE
NlchlBoard Fiber -Cement Lop Siding Is designed to be Installed
to plywood sheathing. Such plywood shall be %0 (5-ply)
® minimum, APA rated sheathing, Structural 1 grade, with a
�o specified specific gravity of 0.60 or greater (e.g. Douglas
Fir -Larch or Southern Firm). Use Of other grade plywood shall
require a slie-specific fastener design for the siding attachment,
signed and sealed by a Florida Registered Professional
Engineer.
Such plywood sheathing shag be supported by framing
consisting of 2" x 4' minimum wood studs, or 2' x 6'
16ga metal studs, each at 16" o/c. Plywood shall be
attached to the framing studs In accordance with the
Florida Building Code (High Velocity Hurricane Zone).
OCT 0 5 2018
DESCRIPTION and SPECIMCATION
NIchlPanal siding material Is a non -asbestos 8bar cement
product tasted In accordance with ASTM C-1185 d ASTM
C-1188 Type A meeting the requirements of the Florida Building
Code (HVHZ). Panels era available In four -toot widths within
the maximum end mlNmum dlmanslons specified below.
Plank Dimensions
IAgdih
Len
Thkkness
48.
a.
%e
48"
1ir
%e
48.
IT
g,e
0ealan Pressure Rating -104 psf
LIMITATIONS
1. Ali Installation shag be done In accordance with
this Notice of Acceptance, the manufacturer's
Installation recommendations, and the applicable
sections of the Florida Building Code Including'
High Velocity Hurricane Zone where Requhedl
2. Wood studs and plywood sheathing supporting
NlchlPenal aiding shall conform to the Florida
Building Code (Including the HVHZ where
rsqulmd), and the requirements of this Notice of
Acceptance (See Note Sheet 2). 1
3. Siding installed as specified herein shag be
classified as Large Missile Impact Resistant
PRODUCT REVISED
socomp udth the Florida
DxgdIna 0odi
80A-No. 1"815.08
Exprrntron D • 07/22I2018
ay
Frisco a a Product control
N
OU 0 5 2018
V
No 71007
Q
9 STATE OF r.w
NlchiPanal NICHIHA USA, INC.
Fiber Ceti eaese oMscasmne.kcnsooel
KrAlFwel Sidhp
Weather-rbn1sont Barrier
—ed x 2' Corrmn Nd
e• clo vearatly, a• o/c
Hod:anl - V Min,
3" Mats Edge lllshNa.
91' Plywood sheathing
Fastened to 5" per
Ronda BuMng Code
PRODUCT RENEWED
as complying with the Florida
Building Code
NOA-No. 19-0328.02
Expiration e07/2212024
By
MlamhDa a Product Control
NICHIPANEL SIDING INSTALLATION
• The panels shall be applied vertically, avoiding horizontal Joints.
• The panels shell be Installed over %" APA rated exterior -grads
plywood (SG - 0.50 min.) supported by 2°x4` minimum wood
studs spaced a maximum of 16" o.c.
• Fasteners shall be placed at 6" o/c In the vertical direction and
6"o/c In the horizontal direction.
• A distance of between Y4" and 3" from the edges shall always
be observed.
PLYWOOD SHEATHING NOTE
NlchlPanel Fiber -Cement Siding Is designed to be Installed to
plywood sheathing. Such plywood shell be %" (5-ply) minimum,
APA rated sheathing, Structural 1 grade, with a specified
specific gravity of 0.50 or greater (e.g. Douglas Flr Larch or
Southern Pine). Use of other grade plywood shall require a
site -specific fastener design for the siding attachment, signed
and sealed by a Florida Registered Professional Engineer.
Such plywood sheathing shall be supported by framing
consisting of 2" x 4• minimum wood studs, or 2" x 6" 10ga metal
studs, each at 116" o/c. Plywood shall be attached to the framing
studs In accordance with the Florida Building Code (High
Velocity Hurricane Zone).
PRODUCT REVISED
as comprying with the Florida
BulhllntiCode
NDANo. 18-0815.06
Expiration Date 07/22/2019
By
Mlam a a Product Central
AN C�V
OCT 0 2018
No 71907
STATE OF :;