Loading...
HomeMy WebLinkAboutNOAREVIEWED FOR MDiADE IAMI•CODE COMPLIANCEto Em ST. LU C I E COUNTY PRODUCT CONMIAMI-DTRADSOL SECTCOUINON TY �ryry ��++//++ 1 t805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONONDCdRBSOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIMION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eav/ecoaamv Nichiha USA, Inc. SCANNEL, 6465 E. Johns Crossing File COPY BY Johns Creek, GA 30097 St. Lucie Count%• SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: NichiPr oducts"m Fiber -Cement Siding APPROVAL DOCUMENT: Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and Drawing No. ITS N2090403, titled "NichiTanel", sheets 1 and 2 of 2, both dated 10/0512018, prepared by Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. AVIISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 18-0815.06 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 19-0328.02 Expiration Date: July 22, 2024 Approval Date: May 23, 2019 051 r 3/�v l Page l Nichiha USA, Inc. NOTICE OF ACCEPTANCE: . EVIDENCE SUBMITTED 1. Evidence submitted under previous NOA'S— A. DRAWINGS "Submitted under NOA # 15-1102.141, 1. Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and Drawing No. ITS N2090403, titled "NichiPanel", sheets 1 and 2 of 2, both dated 03/16/2009, prepared by Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E. on 10/13/2015. B. TESTS "Submitted underNOA # 09-051L01" 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram ofNichiProducts Fiber -Cement Panels, prepared by Intertek Testing Services NA LTD, Report No. 3145127COQ-004A, dated 08/07/08, signed and sealed by Rick Curkeet, P.E. 2. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram ofNichiBoards and EcoPlanks, prepared by Intertek Testing Services NA LTD, Report No. 3145127COQ-004B, dated 10/24/08, signed and sealed by Rick Curkeet, P.E. 3. Test report on Standard Specification for Flat Non -Asbestos Fiber -Cement Sheets of NichiProducts Fiber -Cement Panels, per ASTM C1186-07, prepared by Intertek Testing Services NA LTD, Report No. 3145123COQ-005, dated 05/20/08, with a revision dated 02/02109, signed and sealed by Rick Curkeet, P.E. 4. Test report on Surface Burning Characteristics of NichiPanel Fiber -Cement Panels, per ASTM E84-08, prepared by Intertek Testing Services NA LTD, Report No. 3145123COQ-006, dated 06/25/08, with a revision dated 04/03/09, signed and sealed by Rick Curkeet, P.E. 5. Test report on Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C ofNichiha M series unprimed cementitious, per ASTM E136-99, prepared by Intertek Testing Services NA LTD, Report No. 3105885COQ-002, dated 10/26/06, with a revision dated 03130/09, signed and sealed by Rick Curkeet, P.E. C. CALCULATIONS "Submitted under NOA # 14-0715.03" 1. Anchor calculations prepared by Progressive Engineering, Inc., dated 10/22/2014, signed and sealed by Carl D. Fussner, P.E. "Submitted under NOA # 09-0511.01" 2. Anchor analyses prepared by Category 5 Engineering Services, Inc., dated 04103/2009, signed and sealed by Emma T. Mellinger, P.E. OS r3 2015. Carlos M. Utrera, P.E. Product Control Examiner NOA No.19-0328.02 Expiration Date: July 22, 2024 Approval Date: May 23, 2019 E-1 Nichiha USA, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA # 15-1102.14" 1. Drawing No. ITS N1090403 and ITS N2090403 statements of code conformance to the 51 edition (2014) FBC issued by Nichiha USA, Inc, dated 03/16/2009, signed and sealed by Carl D. Fussner, P.E. on 10/13/2015. 2. Statement letter of no financial interest issued by Progressive Engineering, Inc., dated 10/13/2015, signed and sealed by Carl D. Fussner, P.E_ 2. Evidence submitted under NOA # 18-0815.06 A. DRAWINGS 1. Drawing No. ITS N1090403, titled "NichiBoard", sheets 1 and 2 of 2 and Drawing No. ITS N2090403, titled "NichiPanel", sheets 1 and 2 of 2, both dated 10/65/2018, prepared by Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 6h edition (2017) FBC issued by PEI Engineering Services, Inc, dated 02/22/2018, signed and sealed by Carl D. Fussner, P.E. ^ oS i3�iot9 Carlos M Utrera, P.E. Product Control Examiner NOA No.19-0328.02 Expiration Date: duly 22, 2024 Approval Date: May 23, 2019 E-2 B° t olc Sl rn 12' Pe ( 1: I" Panels Shown / 51W Panels Shown 1�1�1 �I�IrI �Irl�l 1�Ifi1�1 II�I�1�1 I1�1�1�1 sl�l�ll�l .. r r 1 • ; 1010a! r r Mimi" , . PRODUCT REVISED / as complyln with the Florida Building Code NOA=No. 1 B-0B16.06 Expiration Date 0712212019 By Miami-130d6 Product Control lax ° a/o Spacing rryp•) 5t Panel Height (TYp•) 1�Ovedap ITmJ Nich[Board Fiber Cement Siding DESCRIPTION and SPECIFICATION NIchlBoard lap siding material Is a non -asbestos fiber cement product tested In accordance with ASTM C.1185 & ASTM C.1188 Type A mssUog the raqulremeats of the Florida Building Code (HVHZ). Boards are available In a variety of widths within the maximum and minimum dimandons specified below. Plank Dimensions Width Length Thickness 5Y,°MIM 12' !ie 12° Max. 12' pia Design Pressure Rating .126 put LIMITATIONS 1. All Installation shall be done In accordance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code Including High Velocity Hurricane Zone whore Required. 2. Wood studs and plywood sheathing supporting MchlBoard and EmPlank siding shell conform to the Florida Building Coda (Indudhng the HVHZ where required), and the requirements of this Notice of Acceptance (See Note Shoat 2). 3. Siding Installed as specified herein shag be dsssftled.as Large Missile Impact Realstent OCT 0 5 2010 c No 171 B07 STATE OF NICHIHA USA, INC. 5485 E. Jot=Crouse. JOMe C=k. Gk 30DO PRODUCT REVISED an comPlyrn® with the Florida Building Code NOA-No. 18-0815.08 Expiration D to 07/22/2019 By � Miami- ad Product Control NICHIBOARD SIDING INSTALLATION • The boards shall he applied horizontally commencing from the bottom course of the wall. • Each successive course shall ovedap the prior course by i Ya". . Any vertical Joints shall be over framing members, with fasteners either side of the Joint. • The planks shall be Installed over V APA rated extedo"rade plywood (SG = 0.50 min.) supported by 2' x 4' minimum wood —1,11ohl6oard slang studs spaced a maximum of 16" o.c. -woauarvaa.h.w 9.id.r The siding shell be fastened through over -lapping planks wlth edx2VCommw Nag@ Bd x 2 Ye long common nells over wood studs. s Ye da vadwM, a, olo A row of fasteners shall be placed In the ovedap of each 2- M"l.gy. YP ut", 2• diet ads• 4' Mh,a. I course, spaced 6' o/c In the horizontal direction. P • Successive rows of fasteners shell be spaced not more then 5 %' o/c. (boards greater than 6 %' In width shag require an %• Plywood shoamng- additional row of fasteners In the center of the plank). Faskamd to Saida car A distance of between a/a and 2' from the edges shell always be observed. PRODUCT RENEWED as complying with the Florida Building Coda NOA-tin. 19-0328.02 Expiration DOAP0712212024 By MIamF-Da o Produ—77 ct Control PLYWOOD SHEATHING NOTE NlchlBoard Fiber -Cement Lop Siding Is designed to be Installed to plywood sheathing. Such plywood shall be %0 (5-ply) ® minimum, APA rated sheathing, Structural 1 grade, with a �o specified specific gravity of 0.60 or greater (e.g. Douglas Fir -Larch or Southern Firm). Use Of other grade plywood shall require a slie-specific fastener design for the siding attachment, signed and sealed by a Florida Registered Professional Engineer. Such plywood sheathing shag be supported by framing consisting of 2" x 4' minimum wood studs, or 2' x 6' 16ga metal studs, each at 16" o/c. Plywood shall be attached to the framing studs In accordance with the Florida Building Code (High Velocity Hurricane Zone). OCT 0 5 2018 DESCRIPTION and SPECIMCATION NIchlPanal siding material Is a non -asbestos 8bar cement product tasted In accordance with ASTM C-1185 d ASTM C-1188 Type A meeting the requirements of the Florida Building Code (HVHZ). Panels era available In four -toot widths within the maximum end mlNmum dlmanslons specified below. Plank Dimensions IAgdih Len Thkkness 48. a. %e 48" 1ir %e 48. IT g,e 0ealan Pressure Rating -104 psf LIMITATIONS 1. Ali Installation shag be done In accordance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code Including' High Velocity Hurricane Zone where Requhedl 2. Wood studs and plywood sheathing supporting NlchlPenal aiding shall conform to the Florida Building Code (Including the HVHZ where rsqulmd), and the requirements of this Notice of Acceptance (See Note Sheet 2). 1 3. Siding installed as specified herein shag be classified as Large Missile Impact Resistant PRODUCT REVISED socomp udth the Florida DxgdIna 0odi 80A-No. 1"815.08 Exprrntron D • 07/22I2018 ay Frisco a a Product control N OU 0 5 2018 V No 71007 Q 9 STATE OF r.w NlchiPanal NICHIHA USA, INC. Fiber Ceti eaese oMscasmne.kcnsooel KrAlFwel Sidhp Weather-rbn1sont Barrier —ed x 2' Corrmn Nd e• clo vearatly, a• o/c Hod:anl - V Min, 3" Mats Edge lllshNa. 91' Plywood sheathing Fastened to 5" per Ronda BuMng Code PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 19-0328.02 Expiration e07/2212024 By MlamhDa a Product Control NICHIPANEL SIDING INSTALLATION • The panels shall be applied vertically, avoiding horizontal Joints. • The panels shell be Installed over %" APA rated exterior -grads plywood (SG - 0.50 min.) supported by 2°x4` minimum wood studs spaced a maximum of 16" o.c. • Fasteners shall be placed at 6" o/c In the vertical direction and 6"o/c In the horizontal direction. • A distance of between Y4" and 3" from the edges shall always be observed. PLYWOOD SHEATHING NOTE NlchlPanel Fiber -Cement Siding Is designed to be Installed to plywood sheathing. Such plywood shell be %" (5-ply) minimum, APA rated sheathing, Structural 1 grade, with a specified specific gravity of 0.50 or greater (e.g. Douglas Flr Larch or Southern Pine). Use of other grade plywood shall require a site -specific fastener design for the siding attachment, signed and sealed by a Florida Registered Professional Engineer. Such plywood sheathing shall be supported by framing consisting of 2" x 4• minimum wood studs, or 2" x 6" 10ga metal studs, each at 116" o/c. Plywood shall be attached to the framing studs In accordance with the Florida Building Code (High Velocity Hurricane Zone). PRODUCT REVISED as comprying with the Florida BulhllntiCode NDANo. 18-0815.06 Expiration Date 07/22/2019 By Mlam a a Product Central AN C�V OCT 0 2018 No 71907 STATE OF :;