HomeMy WebLinkAboutPLANSABBREVIATIONS: AC ALTERNATING CURRENT MOP MAIN DISTRIBUTION PANELBOARD AJC AIR CONDITIONING MTS MANUAL TRANSFER SWITCH AFG ABOVE FINISHED GRADE MUD MAIN LUGS ONLY AL ALUMINUM NEC NATIONAL ELECTRICAL CODE AHU AIR HANDLING UNIT NTS NOT TO SCALE ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NON -SE NON SERVICE ENTRANCE RATED C CONDUIT PLCS PLACES (QUANTITY) CU COPPER CONDUCTOR PNL PANEL COVB CITY OFVERO BEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECT CURRENT RMC RIGID METAL CONDUIT DISC DISCONNECT RTU ROOF TOP UNIT EXIST EXISTING SE SERVICE ENTRANCE RATED FPL FLORIDA POWER a LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER TRANS, TX TRANSFORMER IRC INDIAN RIVER COUNTY UG UNDERGROUND KVA KILOVOLTAMPERE UL UNDERWRITERS LABORATORY KW KILOWATT UON UNLESS OTHERWISE NOTED MC METAL CLAD CABLE V VOLT MCB MAIN CIRCUIT BREAKER VA VOLTAMPERE MCC MOTOR CONTROL CENTER W WATT XFMR TRANSFORMER O ®MAN MEANER NEW 20D AMP GENERAC EXISTING NON -SE 400 AMP RATED IETER/MAIN ATS COMBO E 1202401e, NEW ®SRR FPKER 200 AMP GENERA, NONSE RATED ATS ELECTRICAL LEGEND: (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) -�- SURFACE MOUNT 120204V, 10, 3-WIRE PANELBOARD -�- FLUSH MOUNT 120204V, 10, 3WIRE PANELBOARD SURFACE MOUNT 2771480V, 30, 4-WIRE PANELBOARD --Q FLUSH MOUNT 2T!aW, 30, 4WIRE PANEL BOARD UTIUTY METER CAN OR METERIMAIN COMBO UNIT -�-- SURFACE MOUNT AUTOMATIC TRANSFER SWITCH POINT OF NEW CONNECTION RIOR INTERIOR EXISTING PAN BACK FROM E METER/MAIN. EXISTING STINPG 200 AMA PANEMB FeeME SIZE ems' "aaf.E.Rnnuo NOKLFUSED DISCONNECT "� NON FUSED FRPME SIM 3a_NEw NAv.o FUSEDDISCONNECT FUSESIM GENERATOR AND GENERATOR PAD =O GAS STORAGE TANK ® NATURAL GAS METER ATTIC GENERAL NOTES: 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. 2. DARKAND RED UNE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION qO EXISTING 2"PVC UNDERGROUND SERVICE FEEDER ® EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS © EXISTING WVPVC W/ (1) N BARE CU EXISTING 2-PVC WI (3) 0I0 THHN CU, (1) IS THHN CU GROUND © rPVC W1(3) NIU THHN CU. (1) N MINN CU GROUND O f 141rPVC SLEEVE WI GENERAC CABLE WI (3) N THHN CU, (1) N THHN CU GROUND, (6) 914THHN CU © 141VPVC WI (3) N THHN CU, (1) A8 THHN CU GROUND ® 314°PVC Wl (7) 914 THHN CU O 1WPVC WI (1)"BARE CU NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. COMPLETEEIECTRICINC. 637 SEBASTIAN BLVD. SEBASTIAN. FL MINTS (772)38&0533 Sizing Report RefsN Nominal Vol 240 Generator Fuel ,Mice Propane SICng MemM(NECMD) Pan IV (Part III "Idled for seleded c rwlt ImplemeaOSON BoM vafd for SMIe Muse) Ganerd UgM1tlrg& Heougtacks Square Fack9e Being Covemd (M1^21 MOO Small A,I. Cimuil9 (20 amps) Milan alma 2 GENERAC 0 SCANNED BY St. Lucie County Ised(kwl 9 3 1.5 T NEW GENERATOR: Managed Estimded Nameplate A C G H LIOUID COOLED GENERAC 22KW Fue6In-Placs ApWri nwsa Motms Loads (kW) (amps) MV Load lkM aen 5.0 X 5.0 Misrw2ve 1.3 13 ®too AMp BaFAKFx FINISHED FLOOR Dishwasher Rehtgealar 0.8 as Oa - Weli Pump Water Heater 5.5 1.5 5.5 1.5 X 50 Dryer % EXISTING WATER LINE { Caak Cook Top Raf1gerat. _ 3.0 3.0 0.8 3.0 % 9.0 0.8 ' M Erimatetl Nameplace Air COMkioninpa Caolinp Loads Loads 1 (amp) 20V Load EXTERIOR INTERIOR 2TUmt 0Ton UrO X % 26 5.0 % 0.0 FILE '�ip_ EXISTING SIB°X8' CU GROUNDDRODS Hea4noa Heat Pumps Managed Coatis Estimated (2.5 Nam Nameplate (amps) 240V ad (ktNl V Heat Pump (25 2s Ton) x x x 0.0 Heat Pump(5Ton) X 5.0 50 X 0.0 SCOPE OF WORK GENERAL NOTES: • INSTALL (2) 200AMP NON -SE RATED ATS NEXT TO UTILITY MUERIMNN COMBO ON • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION EXTERIOR WALL DETAIL WITH THE LOCAL UTIUTY POWER COMPANY. • UTILIZE A PRE -FABRICATED GENERATOR PAD. THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE BTH EDITION(2017), LOCAL • PROVIDE AND INSTALL (1) 22kW GENERAC LP GAS GENERATOR. ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FOR FROM ATS TO • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN UKE MANNER BY GENERATOR. PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF MASTER ELECTRICIAN • PROWDE(2) LOAD SHED DEVICES PER SIZING DATA THIS SHEET. LICENSED IN THE STATE OF FLORIDA. • GENERATOR TANK AND GAS CONNECTION BY FERRELLGAS UNDER A SEPARATE • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND PERMIT. FASTENED, WITH WORKING SPACE PER NEC 11026. • NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SCOPE OF WORK SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 250. • STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702. AND MANUFACTURER INSTALLATION INSTRUCTIONS. LOAD MANAGEMENT 'LCW LOAD SHED LOAD MANAGEMENTTECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENTAND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS AREALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHUTAC) AND POWER CIRCUITS (RANGE AND WATER HEATER). NNnGENERATOR ADDITION'RISER DIAGRAM EaMaled Aaue unalled Tar¢iem Requirement (URA) (LRA) (URA) la,.SI MWOrk Slarpng A,r'(LRA) 315 134 134 Loatl NEC Summary NEC lord (kM Required General LIM, a R.p+agleS 13.5 Fdimet4Place Appliances aMotore 24A Sumolal Gmreraltnads 37.9 21.1 Cousin, 0 0 Hearng(wldemand fadorsl 0 0 lar,er0HMk,&CxN,ug 0 0 String Maned on regotemeaa M NEC Ankle 22e Pan IV 21.1 Elevalion OA Minimum Sir, Wneraar for motor darling requlremena, 20 BTU Wad required MM00 22 kW Generac Modal Generator Recommended ST.LUCIE COUNTY _PLAN REVIEW BLDG- DATEa ELE . DATE: k' 01 PLUMB: DATE: MECH: DATE: CZ5 W' m h L) JLt. an w LU Z g m q TArZ m M O W O U J Uo U E-1 , _-10/14/2019 1 OF 3 V,=101-0., C R OROUG \ f- N coURT GENERATOR SITE PLAN W � E wz 0 4aa ww E-2 �., 10/142019 2 OF v u S. SCALE: 1.=1U'-0` I LeGENERATOR-.UNLT�BY.7 SEPARATE SUBMITTAL (SEE CONCRETE PAD I x z SCHEDULE FOR MINIMUM �_W EIGHT`REQUIRED)­ YY tlWl.Ei rI1 VI✓ -k"IrCC - PAD THICKNESS FRONT VIEW I PAD LENGTH PAD I x N I I z L9 I W I I I S 95°I SIDE VIEW I{ PAD PAD WIDTH THICKNESS HURRICANE CONCRETE PAD FOR GENERATORS (GENERAC AID HONEYWELL UNITS) (ON-GRADE,APPLICA EI1\15Gl(f'`'T�9`�EE�RIIf°�?G EXPRESSO O TYPICAL ANCHORAGE: (4) 3/8" DIA: AMIFAST CONCRETE INSERTS (PART# 165003 & TEST REPORT 95329 BY ELEMENT MATERIALS TECHNOLOGY) W/ 3/8- DIA. BOLT ASTM A307, 3" MIN. EDGE DISTANCE, 1-3/8" EMBED, INTO CONCRETE (BASE PAN MIN. THICKNESS = 0.69" AND MIN. BEARING STRENGTH = 6 KSI) ISOMETRIC VIEW N LY) ACCORDANCE WITH THE GOVERNING C LOAD REQUIREMENTS AS DETERMINEI �-�-_ WITH THE APPLICABLE BUILDING COI _ THAN OR EQUAL TO THE POSITIVE OR :"GEN PAL NOTES PRESSURE'ASD' CAPACITY VALUES LI ANY ASSEMBLY AS SRO HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THEE ' •I;.,, "S OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017)./p, U!: I NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE) i BY OTHERS ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. IENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS "6/'STATED HEREIN. 4. THE AREA UNDER CONCRETE SLAB ON GROUND SHALL HAVE ALL VEGETATION,SUMPS,-ROOTS, ESAND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY CCOTHERS %THESE CONCRETE PADS HAVE BEEN DESIGNED FOR A MINIMUM'SOIL COEHI0EPIT OF :?ERI FCTION 0.25 AND MINIMUM BEARING CAPACITY OF 2,000 PSF AND MINIMUM SUBGRADE MODULUS 100 M. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. S. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILTY OF THE CONTRACTOR. 6. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. at. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST& DAMAGES INCLUDING LEGAL FEES &APPELLATE FEES RESULTING MOM 'MATERIA, , FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF.THIS"PLAN: 15.-\\ // 7// 7. WATER-TIGHTNESSOFEXISRNGFINISHESSHALLBETHEFULLRESVONSIBILIIYOETHEINSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED-ORALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY -WATERPROOFING OR -LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHAWBETHE FULL RESPONSIBILITY OPTHE INSTALLING CONTRACTOR. i v� B. THE ROLE OF THIS RECORDGINEER. FOR THIS CONSEQUENTLY, THE ARIS CHITECT/ENGINEER IECOINEER RDSHRLL NOT THE ENGINEER LE RECORD. C TEGRIT OF RUSE ARCHITECT/ENGINEER OFRECOES SHALL IBE C RESPONSIBLE FOR THE INTEGRITY OF ALL BUPPDRTING�SUc L_'_l I I N [THIS DESIGN WHICH hSHALL BE COORDINATED By THE PERMITTING CONTRACTOR.( �y��l� yTC l��jll VL� 9. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIHCPROJECLSITE., INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR-SUPPLIED,DATA � ANDy° MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBIl'OR'LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE HELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN `-�,� OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION l ' PRIOR TO MODIFICATION OF EXISTING HELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND I ��.INVALIDATE OUR CERTIFICATION. ��10.-,,,EXCEPi AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE .,INTENDED. CONCRETE PAD SCHEDULE ITEM I GENERATOR UNIT UNIT DIMENSIONS (IN) MINIMUM J UNIT." WEIGHT (CBS)- Ltvl�ING CONCRETE PAD MODEL# PAD DIMENSIONS (IN) PAD WEIGHT (CBS) WIND LOADS WIDTH LENGTH _t141 -�. HEIGHT �I1a WIDTH LENGTH' THICKNESS ALLOWABLE PRESSURE (PSF) ALLOWABLE RESULTANT (LBS). I BKW I 25.00 48A0' 29fOOi, -J 60-� jFG3154-4G 30.56 53.56 4.00 240 30.72 296.93 2 30KW 25.00 48.00 29,00 407 FG3154-4G 30:56 53.56 4.00 240 33.13. 320.25 3 14KW 2S.00 48.00 29.00 435 FG3154-4G 30.56 53.56 4.00 240 34.57 334.21 4 16KW 25.00 48.00 29.00 448 FG3154-0G 30.56 53.56 4.00 2401 Y 35.26 340.85 ;lr 5 16KW 25.00 48.00 29.00 513 FG3154-4G 30.56 53.56 4.()Fl= - 240- 38.53 2/,372.44 6 17KW 25.00 48.00 29.00 471 FG3154-4G 30.56 53.56 4.00 I' <240' J^A°AD f7351.88 7 17KW 25.00 0 29.00 431 FG3154-4G 30.56 53.56 4.00 h -=240~ 34.37 332.20 i 8 20KW 25.OD 0 29.00 451 FG3154-4G 30.56 53.56 4A0 '� _�240`' 35:39� 4-342.12 - 9 2OKW I 25.00 0 !48.00 29.00 448 FG3154-4G 30.56 53.56 4.00� �240' 35.26 a 340.85 10 22KW 25.00 29.00 466 FG3154AG 30.56 53.56 4.00 240 � 35.35 351.38 E) lj Gt HIRE RI NOTES:t I i !-3_6 lY `.^ TE PADS WEIGM PROVIDED BY MANUFACTURER, VERIFIED BY OTHERS. �.T, /ems, r+F �ir-•I 2 FULL THICKNESS OF PADS SHALL BE CONSTRUCTED WITH SOLID PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH,"•^-^ ^°^ °°'°^T'°^^"°- Q �" 3- ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE By CASE BASIS. LARGER CONCRETE PADS MAY BE DESIGNE 4- CONTRACTOR SHALL PROVIDE 5/8' DIA (0.675' O.D.) GALV. TUBE ASTM A53B SCH 40 MIN. OR 1/2- DIA. SOLID COPPER RA EMBED. AS PER CURRENT ELECTRICAL CODE, BY OTHERS) INFO GROUND THROUGH CONCRETE PAD FOR SLIDING RESISTANCE FROM ANY CONCRETE FACE (NOT SHOWN) . NO GALE PRE -FABRICATED GENERATOR PAD DETAIL IFTHFAE IS NO , p O Wmmus OLL ow& VI � w ar S WU"zK5 �Q'�wwa M11J wywjU 3� U)�azw O W w 00 �O I 14-1669A I . IN SEE MIN SEE M�ILlll DISTANCE � 2 m p ¢UQ¢OW �JOU ZZx_I WWQ W U N m 2 m0 a ------------- E-3 ,. _-10/1412019 30F3