gaf.com SBS Self -Adhering Roofing System
How Do I Prepare for a Liberty'" Project?
Before You Start.. the installation of your new Liberty" SBS Self -Adhering Roofing, do the following:
• Read Instructions Thoroughly... and understand how the entire system works before starting your installation.
• Understand The Materials... know when and where to use each component, why each is necessary, and the common mistakes to avoid.
• Contact GAF Technical Services... at 1-8041`100F411 for detailed information on specific applications.
Do's And Don'ts... Liberty' SBS Self -Adhering Roofing Systems are designed to be installed over low -sloped roof decks.
• Do Install On Roofs Between 1/2• And 6° Per Foot Incline... and backnail the Liberty' Cap Sheet when the slope is greater than
1• per foot. Contact GAF Technical Services at 1-800-ROOF-411 for fastening requirements specific to your project.
• Do Install In Moderate Temperatures... between 45oF (7C) and 95OF (350C), to assure proper adhesion and easier work conditions.
• Do Install Over Clean, Smooth Surfaces... that are free of dirt, debris, and damage, or are otherwise unsuitable for installation.
• Don't Work Alone... GAF recommends at least 2 people install Liberty" SBS Self -Adhering Roofing.
SAFETY FIRST... Protect yourself and others. Consider the following common-sense safety precautions, including:
® Wear Glasses
• Wear appropriate clothing, including protective footwear, eye wear, and gloves.
• Be aware of your surroundings. Watch for power lines when working near ladders and use common sense on your job site.
• Follow local building codes.
• Bend at the knees. Never lift with your back.
13 Wear Gloves
Precautionary Note: The application instructions for this product require the use of primers adhesives, or cements that contain
Common
solvents Apply solvent -based products ONLY as instructed. Excess application of solvent based products may affect the performance
Mistakes
of this product, delay application o/ the cap sheet, cause surface blistering of the cap sheet, or result in the asphalt flowing, dripping, or
and How to
Q Avoid Them
staining. You may notice unpleasant odors from the solvents, which will dissipate when the solvent -based product has dried.
What Tools & Equipment Do I Need to Install a Liberty" Roof?
o
Trowel Gloves Hammer Utility Knife Weighted Roller Brush Tape Measure Caulk Gun Liberty'" Installation Kit
Liberty' Roof Materials... What Do I Need to Install a Quality Roof?
• Liberty" Installation Kit... comes with enough primer and cement to install approximately 200 square feet of membrane.
Additional kits or extra primer and cement may be purchased if necessary.
• Liberty- Self -Adhering Base/Ply... is the base weatherproofing layer when applied over acceptable, prepared decks
or insulations. Each roll contains approximately 200 square feet.
• Liberty" MA Mechanically Attached Base... is applied when the deck is unsuitable for set -adhered sheets or when a nailed
base sheet is preferred. Each roll contains approximately 200 square feet.
• Liberty" Self -Adhered Cap... is the first line of defense from the weather. Each roll contains approximately 100 square feet.
• Metal Flashing... for covering roof perimeter edges. Metal flashings are typically sold in 10-foot sections and must be primed
with asphalt primer and allowed to dry before installation.
• Everything Else... when measuring, note the size and number of vent pipes, and other flashings. Don't forget any nails, lumber,
or other additional materials that you may need.
Liberty" Roof Systems... Which Roof is Right for Me?
2-Ply Layout (SA Base)
2-Ply Layout (MA Base)
3-Ply Layout
Note: Single -ply application not shown; visit gaf.com for details if required.
STEP i - Preparing for a Liberty" Roof... Is the Surface Ready?
Remove All Existing Roofs... and determine the suitabilittyy of the existing roof deck. Alternately,
Ube; MA Mechanically Attached Base maYy be installedover certain roof types or deck types not
• listed. Contact GAF Technical Services at 1-800-ROOF-411 for more information.
• Inspect The Deck... and determine what type of preparation is required. Replace damaged deck
materials as necessary.
Install Insulation (if ® desired). using GAF DRILL-TECTM screws and plates or GAF approved adhesives. • Use minimum 1/2 thick EnergyGuerdTM Polyiso Insulation with approved fiberglass or paper facer.
Acceptable Decks
15/32' Minimum Plywood .......... Apply light asphalt primer at 112 to 3/4 gal per 100 sq. ft.
GAF EnergyGuard" Polyiso Insulation.......... Install LibertyTM Self -Adhered Base/Ply Sheet directly to
insulation.
Other Deck Types May Be Acceptable.......... Contact GAF Technical Services at 1-800-ROOF-411
for more information.
Common Mistakes (and How to Avoid Them)...
Poor Roof Drainage... can lead to leaks at the seams. Before installation, fix the roof deck at
• locations where water remains after 48 hours.
• Not Priming The Deck.. or metal may lead to poor adhesion and is a leading cause of problems.
STEP 2 - Installing Liberty" Base Sheet... Nailed Base or Adhered Base?
=� 1. Align Base Sheets... Starting at the lowest point of the roof where there are gutter or fascia edges,
extend the base sheet over and down the fascia fullyY behind the metal edge or gutter height,
L, fastened along roof edge and along fascia 9" o.c. Ivlmimum overhang is 1 . Be in with 1/i vndth
((19 11/16) sheets in 2-ply systems. Use 1/3 width (13 1/8') starter sheets in 3 fly systems and install
2nO ply (interply sheet) starting with 1IR width (1911/16') sheets to maintain side lap offsets.
13
2. Install MA Base Sheet (Where Required)... using nails with 1' cap heads. Fasten every 9" in the lap
and stagger 2 rows in the field every 18' (see Fasfening detail). Cover the entire roof area.
3. Install Self -Adhered Base Sheet... by aligning sheets properly before removin the release liners. Roll
out sheet and let ft sit or "relax" for at least 30 minutes to minimize the potential for wrinkles that can form
during installation. Remove one side of the release liner at a time.
4. Overlap Following Rows of Base Sheet... horizontalry, (side lap l by using the line found on the base
sheet. Remove release films from top and bottom half of sheet in [um, carefully rolling back into position
to maintain over)ap. Where no line is ppresent, overlap by 3'. Overlap vertically (end laps) by at least 6'.
Make sure all end laps are at least 18" apart.
5. Roll Base Sheet Into Place (Base Onlv)... using a weighted lawn or linoleum roller.
This improves adhesion to the deck and ensures properly sealed laps.
NOTE: A base sheet is not required; visit gaf.com for more information.
Common Mistakes (and How to Avoid Them)...
Not Letting The Liberty^" Sheets Relax... can lead to wrinkles. In colder weather, the rolls require more
time to flatten.
• Not Rolling The Base Sheets... Is a leading cause of opening laps. Always pay close attention to laps when
rolling the base sheets.
STEP 3 - Installing Liberty' Self -Adhered Cap Sheet.. Where Do I Begin?
-.� 1. Install Edge Flashin5... over the base sheet in a 1/8" bed of cement and stagger nail with two rows of
- roofing netts, 3" o.c. Prime the face on the roof and allow to dry before installing cap sheet.
Li 2. Align Cap Sheet... 1/4' from the edge at the lowest point of the roof. Roll out and position full
width (39 3/8") sheets with the selvage edge on the high side of the roof. Allow sheet to relax
for at least 30 minutes prior to installing.
3. Overlap Following Rows... horizontally (side lap) by aligning with the bottom of the salvagpe edgge.
Vertical (end laps) must be overlapped by at least 6 and applied in a 1/8" bed of Matre 201 SBS
Flashin% Cement Make sure all end laps are at least 18' apart and have clipped corners (see End Lap
detail). t�AF recommends installing a bead of plastic cement along the step up length of the lap.
4. Remove Release Films... from top to bottom half of sheet in turn, carefully rolling back into position
to maintain overlap Remove selvage edge release film prior to installing bottom Half of sheet and
finishing the side lap.
S. Roll the Cap Sheet Into Place... using a weighted roller. This improves adhesion to the base sheet
and ensures properly sealed laps.
Common Mistakes (and How to Avoid Them)...
ANot Priming the Edge Metal... can cause the cap sheet to peel away at the edges. Always prime
• edge metal before installing cap sheet
• Not Applying Cement at the End taps... can cause laps to open. All locations where sheets extend
over granules must be set in cement.
STEP 4 - Cleaning Up and Maintaining Your Liberty" Roof..
Remove All Tools and Materials From the Roof... and make sure there is no debris that can slow or
stop the flow of water.
�� • Dispose of Materials Properly... following all federal, state, and local laws.
Insn¢cf the Roof AnnuaIW... and remove any leaves, branches, or vegetation that may be present.
®Look for other damage an repair if necessary.
• Keep Gutters Clean... to ensure proper water flow and minimize the possibility of damaging ice dams.
w
Fastening
End Lap
Edge Flashing
Shingle Tie -In
@2013 GAF 9113 • #349 RESLB108