Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED BY FORM R405-2017 St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TOTTEN ADDITION Builder Name: Street: 6511 FORT PIERCE BLVD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: JAMES & LINDA TOTTEN Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (320.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 320.00 ft' 3. Number of units, if multiple family 1 b. WA c. N/A R= ftz R= ft' 4. Number of Bedrooms 0 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (200.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 200.00 ft' 6. Conditioned floor area above grade (ft') 200 b. N/A R= ft' Conditioned floor area below grade (ft� 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(24.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 40 a. U-Factor: Sgl, U=0.79 24.00 ft' SHGC: SHGC=0.50 b. U-Factor: N/A ft. 12. Cooling systems kStu/hr Efficiency SHGC: a. Central Unit 28.0 SEER:14.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kStu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: REVIEWED FOR Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.500 g� wq 14. Hot water CODE COMPLIANCE Insulation Area 8. Floor Types (adeE a. 1 cP �f r ST. LUCIE COUNT®F: 38.335 Edge In a. Slab -On -Grade Edge Insulation R=0.0 200.00 ft' b. Conservation features BOCC c. N/A i R= ft' 15. Credits CF, Pstat Glass/Floor Area: 0.120 Total Proposed Modified Loads: 14.29 PASS Total Baseline Loads: 14.40 I hereby certify that the plans and specifications covered by Review of the plans and VHE Srq?F this calculation are in compliance with the Florida Energy specifications covered by this O� _- ; , p Code. calculation indicates compliance i„' '- z ' O with the Florida Energy Code. g� r+ urrr°%, ::.a .°,`.:•`3; O� PREPARER BY: DATE: - Before construction is completed this building will be inspected for y compliance with Section 553.908 I hereby certify that this building, as designed s in compliance Florida Statutes. yS with the Florida Ene y de. C00 WE OWNER/AGE BUILDING OFFICIAL: DATE: �- - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 10/1/2019 1:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: - # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: TOTTEN ADDITION Bedrooms: 0 User Conditioned Area: 200 JAMES & LINDA TOTTEN Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: ST. LUCIE COUNTY Whole House Fan: Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 6511 FORT PIERCE BL County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl no 1600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ADDITION 200 1600 Yes 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 60 It 0 200 ft2 ___ 0 0 1 ROOF J # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 217 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC - 1 Full attic Vented 150 200 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 19 Blown 200 ft2 0.11 Wood 10/1/2019 1:32 PM EnergyGauge® USA 6.0.02 (Rev. 1)'- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY cHFCKI ICT RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 SW 2 S —3 N Exterior Frame - Wood Exterior Frame -Wood Exterior Frame - Wood ADDITION 13 20 8 160.0 ft' 0 0.23 0.5 ADDITION 13 10 8 80.0 ft' 0 0.23 0.5 ADDITION 13 10 8 80.0 ft' 0 0.23 0.5 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area — 1 SW Insulated ADDITION None .46 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening — 1 — 2 SW 1 Metal Single (Clear) Yes 0.79 0.5 N 12.0 ft' 2 ft 0 in 1 ft 0 in None SW 1 Metal Single (Clear) Yes 0.79 0.5 N 12.0 ft' 2 ft 0 in 1 ft 0 in None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation — 1 352 ft' 352 ft' 21 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 133.3 7.32 13.77 .0881 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit/ None SEER: 14 28 kBtu/hr 840 cfm 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector Storage System Model # Collector Model # Area Volume FEF — ft' 10/1/2019 1:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHFr1C1 IAT RFPnPT DUCTS • / --Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 40 ft- Attic 10 ft' Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: Jan Heating ,]Y Feb r' [X] Mar AApr Jun ] 4X] Jul r[[ ]] Aug r[[]] Sep �]j] Nov f�C]] Dec Venting I 1 Jan L J I 1 Feb L J [Xl Mar May LX1 Jun [ ] Jul I Aug lXl [ Sep lXl Lxl Occtt lxl [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 ADDITION 10/1/2019 1:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TOTTEN ADDITION Builder Name: ' Street: 6511 FORT PIERCE BLVD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner: DAMES & LINDA TOTTEN Jurisdiction: ST. LUCIE COUNTY = Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. ElectricaVphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids �u__icrinkler cover Plates and walls or ceilingq _n i_ :_ ... .. ."a;; uc III awulaance with the provisions or ruc-auu. 10/1/2019 1:32 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (ifmultiple-family)3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 28.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 200 d) Room unit/PTAC EER e) Other 14.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.790 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.500 14. Heating system: Capacity 27.0 c) Area 7c. 24.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0. a) U-factor:(weighted average) Sa. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 19.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on instal ode compliant features. Builder Signature: Date: la- Z 3 " / S C Address of New Home: 6511 FORT PIERCE BLVD. City/FL Zip: FT. PIERCE. FL = 10/112019 1:32:12 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect Summary Job: wrightsoft° ! rY Date: Enure House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 PIOM: 772-466-6799 Email: QUICKCALCS@AOL.COM Promect Information For. JAMES & UNDATOTTEN 6511 FORT PIERCE BLVD., FORT PIERCE, FL Notes: Design• • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Insidedb 75 OF Design TO 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15852 Btuh Structure 15903 Btuh Duds 3563 Btuh Ducts 4918 Btuh Central vent (0 dm) 0 Btuh Central vent (0 cfin) 0 Btuh none (none) Humidification 0 Bluh Blower 0 Btuh Piping 0 Btuh Equipment load 19415 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 19780 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3119 Btuh Ducts 1401 Btuh Central vent (0 cfm) 0 Btuh Area(ft� Heatingg Coolingg (none) 1354 1354 Equipment latent load 4520 Btuh Volume (fit) 11986 11986 Airchanggesthour Equiv.AVF 0.45 0.23 Equipment Total Load (Sen+Lat) 24300 Btuh (dim) 90 46 Req. total capacity at 0.70 SHR 2A ton Heating Equipment Summary Cooling Equipment Summary Make Make INTERNATIONAL COMFORT PRODUCTS Trade Trade EXISTING EQUIPMENT Model Cond TCA430AK4 AHRI ref Coil NFCX3600C2 AHRI ref Efficiency 100 EFF Efficiency 11.5 EER,14 SEER Heating input 5.1 kW Sensible cooling 19600 Btuh Heating output 17505 Btuh Latentcooling 8400 Btuh Temperature rise 50 OF Total cooling 28000 Btuh Actual airflow 319 cfm Actual airflow 933 cfm Airflowfador 0.016 crm/Btuh Airflow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ wrights f[' 20130C-0114:31:42 •••- RigFkSU"Uriversal 2019 19.0.07 RSU08101 Page 1 �� ...KY)ow rts\WdgtLroflHVAC1TOTTENADDMON.np Calc=MJ8 Fror/Doorlares:NE wrightsoft, Right-JO Worksheet Job: Entire House Data: QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORTPIERCE, FL34946 Ptore:772-466-6799 Email:QUICKCALCS@AOL.COM 1 2 3 4 5 Roan reme Exposed%%d1 Room height Room dimensions Roun area Ertfire House 148.0 It 8.9 ft 1354.0 W E)WIMGHOUSE 108.0 ft 9.0 It heavcod 1.0 x 1154.0 It 1154.0 ft' Ty Condon number U-value (BWMtz°Fl Or HTM (Bull" Area (f?) w pedmebar (f) Load (BWh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cod Gross NrPiS Heat Cod Gross N/P5 Heat Cod 6 11 l4J- �C �C -D 12C-0sv --" 1Aclom 1A-d= 11D0 12C-0OW 1Aclam 1AcIom 12C-0sv - 1Aciam „11DO 12C-Ow 1Aclon j2Cc0e'w�___ 16B-30ad 22Agpf - 0.091 1.270 1270 __0.390 0.091 1270 1270 -"0.091 1270 _.0.390 ne ne ne _ne- w w _se w sw -w w255 nw ✓-_ - �, 255, 35.56 35.56 -10.92 755 35.56 _35.56 2.55 35.56 __10.92 35.56 _ 255=-'7.06 0.90 _�27.69 1.0G 70.43 70.43 _10.34. 1.96 41.04 4852 ' 1.96 48.52 _10.34. 1.96 70:43 1.60 �0.00 Y---906 20 30 __ 21 251 6 _ 12 '430 36 __20 305 6 198 1354 1354. 205 0 0 -_21 '--599 711 1057 ,__229 594 213 427 952 1280 _223 762 213 _505 1213 4098 --480 1409 2113 ,�21Z ' 306 20 30 --21 - 235 D 0 _^21 163 5 7 258 7 0 F 219 0 -599 711 1067 ,�229 390 213 427 GS/ 427 0 480 1409 2113 __217 299 246 582 - -�505 582 - 0 428 423 _209 1846 vt/ ��CC 233 5 7 - -374 22 �20 299 0 --198 1354 -_-_ _`j48 456 246 582 --- 731 1747 `211 585 423 _.__209 2166 - �0 171 6 12 Y70 12 --0 225 6 _ 198 1154 _1154 t-C P C_ F .-,_ 0.091 1270 10.091 0.032 _0.989 558 213 =505 1034 `2991. _ 198 1154 108 _ --0 6 C)AED e=,sm 212 -470 Emelope los4gmn 13086 11766 10021 6849 12 a) Mitratm b) Room%entlatw 2766 0 757 0 2081 0 570 0 13 Intemal gains Oovpads@ 230 Appliancesbther a 1380 2000 4 920 2000 Subtotal (lines6 b 13) 15852 15903 12102 12339 14 15 Lewcad=rnaIload L.esstransfer Redstnbufm Sublolal Dudloads 220% 310/( 0 0 0 15852 3563 0 0 0 15903 4918 229% 31% 0 0 0 12102 2720 0 0 0 12339 3818 Total mom load AirmgUmd(dm) 19415 319 20821 933 14822 243 16155 724 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed _ �+- wrri9�+>C+o_Ti- 2019-0rt-01 14:31:42 A& ^•^ Ri91i-SdtWLhwml20l9l9.0.07RSLI08101 Pagel ...KrDownerls\WrigftmftHVAC1TOTTENADDMONnp Calc=1018 Frort Doorfacea:NE wrightsofC Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email:OUICKCALCS@AOL.COM 1 2 3 4 Room name Expasedvall Room height Room dimensions Room area ENCLOSED PORCH 40.0 it 8.0 it heat%cool 20.0 x MO it 200.0 ft' Ty Construction number U-value (BbIW'F) Or HTM (Btuh" Area (fp) or perimeter M Load (Btuh) Area or perimeter Load Heat Cool Gross N0S Heat Cool Gross NIPS Heat Cool s 11 �C �p 1-09N2C091 1ACIom 1ACIom 11D0 12C-Ow 1AcIom 12C:bs 12GOsv 1A-dom J1Dp_ 12C-09v 1Aclom 12C-0sivv` ,16B-30ad 2A^ 0. 1270 -1.270 ne ne ne _ne- se se se s sv _sv_ m w ! = - 2.55 35.56 3556 -�10.92 2.55 35.56 35b6 —256 35.56 _10.92 2.55 35.56 ___-_ 2.55 0.90 _769 1.96 70.43 70.43 _,10.34 1.96 41.D4 48.52 48.52 - 48.52 -_10.34. 1.96 70.43 ____1.06 1.60 ,,,0.00. 0 0 0 - _ '0 0 0 __p 80 0 0 V— 170 15 ___�_20 80 0 � __— 200 �40 � , ` 0 0 0 __0 204 0 0 —` 200 853 223 204 0 _ __0 _.. 179 =f109 0 0 0 lQJ ��(G' _ —0.390 0.091 1270 1270 0.091 1270 _0.390 _0 80 0 0 �` 160 24 _�20 80 0 �0 200 _.200 w,._0 157 0 0 f26 1164 �211 157 _0 0 = 0 ----- - U�/ I r 0.091 1270 _0.061 0.,032 ----- 15 _ C F _ _� -- - 320 0 6 C)AED ax Irti. 682 Emelope loss/gain 3065 2916 12 a) Infiltration b) Roan%entilatm 685 0 188 0 13 Infernal gains Oovpants@ 230 Applianoesblher 2 460 0 Subbfal Qines6to 13) 3750 3564 14 15 Lessextertal load � Redistribufion Subbtel Durtloads 22'/ 31% 0 0 0 3750 $43 0 0 0 3564 1102 Total room load Airrequired(rtm) 4593 75 4666 209 Calculations approved bvACCAto meetall requirements of Manual J 8ti1 Ed wrightso_it- 2019-OQ-01 14:31A2 Aft RigYtS ADDMONs P CaI19.0.07 FrortD 01 Paget ...IODoo+rerts\WrigfYsoftHVAC1TOTiEN ADDRIONnp CaIo=MJB Frort Doarfanes:NE �- wrightsofte Duct System Summary oDate: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE,FL34946 Ptow: 772-466-6799 Emil: QUICKCALCS@AOL.COM Project• • For. JAMES&LINDATOTTEN 6511 FORT PIERCE BLVD., FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow, Total e$ective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 319 dim 92 ft Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 933 cbT1 Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) (Cftn) (dm) FIR (in) (in) Mall Ln (ft) Ln (ft) Trunk ENCLOSEDPORCH C 4666 75 209 0.080 8.0 OXO MFX 22.1 70.0 EXISTING HOUSE-B c 16155 243 724 0.080 15.0 Ox0 MFx 0 0 Return Branch Detail Table Name Grille - Size (in) Htg (dm) Clg (dm) TEL (ft) Design FR �kloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Mati Trunk rb2 Ox0 319 933 0 0 0 0 Ox 0 VIFx wright aft- 2019-0a-0114:31A2 �, •••+-.d.�,�., Riglt-Sute®Uriversa1201919.0.07 RSW9101 xaDoamert%Wri9ltsoftWAC1TOTrENADOMONnp Calc=MI6 Frort Doorrams:NE Pagel