HomeMy WebLinkAboutPLANSFILE Copy BLDG` DgTE:--� DA ELE DATE:J!`q PLUMB: DATE_ M DATE: A SOLAR PV SYSTEM IMPROVEMENT FOR0 : VALLADARES RESIDENCE SCANNED BY St. Lucie County SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL VICINITY MAP Shl Y, ,I PROJECT SITE LOCATION , FOR SOLAR IMPROVEMENT 865SOuthlndlah Rrv4w Dn4 SYSTEM INDEX I SHEET DRAWING NAME CV COVERSHEET SLRI SOLAR SYSTEM EQUIPMENT LOCATION PLAN PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS -------- APPENDIX-------- HB1021 NEW PROVISION + LETTER HANWHA Q CELLS 325W MODULE DATA SHEET ENPHASEIQ7+ MICROINVERTER DATA SHEET I PROJECT: I 0 �w w> oZ �a �zN W K N j 0 h W La C 0 J W W N Z Q w' Q W W W a o b bBE 3€ P N a a W og €E DATE 10/16/2019 �a $ DRAWN BY: 1LL CHKD BY: 11A =w� REC NO. # 29127 SCALE I AS NOTEDa DRAWING#sa +yllr" \`\ S\.14HST I TATE OF 10 LAMONRL,P.L P p9 1 1e �� o Lr WIND ZONE 3 LOCATION TYP. Q-CELL Q.PEAK 325W MODUIETYP. APPROXIMATE LOCATION OF L-FOOT PENETRATION TO 2'.0" SYP TRUSS. FLASH PER 2017 FBC SEE SHEET PVRSS FOR DETAILS. IRONRIDGE XR100 SOLAR RAIL TYP 2 PLCS PER MODULE ARRAY IN ZONES I & 2 APPROXIMATE LOCATION OF ENPHASE ENVOY Q COMBINER BOX (OR EQUAL) APPROXIMATE LOCATION OF MAIN DISTRIBUTION PANEL LOCATED INSIDE BUILDING ROOFTOP JUNCTION BOX APPROXIMATE LOCATION FOR WIRE TRANSITION. SEE SHEET SLR2 4W 1 2V-11" 20141 e-dr (18) Q-CELL Q.PEAK DUO 325W MODULES W/ (18) ENPHASE IQ7+ MICROINVERTERS (9) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (12) 11' XR700 RAIL (6) XR-100 INTERNAL BONDED SPLICE KITS (3) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (70) WIRE MANAGEMENT CLIPS (38) IRONRIDGE L-FEET W/ LAG SCREW (12) IRONRIDGE UFO SLEEVES (12) IRONRIDGE END CAPS FOR RAILS (42) IRONRIDGE GROUNDING UFO CLAMPS (18) LANDSCAPE OR PORTRAIT ENPHASE ENGAGE CABLE CONNECTORS (2) ENPHASE 6 FT EXTENSION CABLE (2) ENPHASE END CAPS (1) NEMA 31? RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT 15 TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. ROOF LAYOUT NOTE SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. SCALE N.T.S. LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON SOUTHERN YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7- TO A MAXIMUM 27" (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. FIELD VERIFY. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBIUTY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE ULTIMATE WIND ZONE 1 MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN, MAX SPAN, MAX SPAN, MAX DEPTH V.n(MPH) CANTILEVER CANTILEVER" CANTILEVER" REQ. 170 4'-0" O.C., 1' 7" O.C. 4'-0" O.C., 1' 7" O.C. 2'-0" O.C., 0'-9" O.C. 3" ` - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "D% RISK CATEGORY II , ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7.10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. "fAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. "'3RDRAIL'IS tJ]REDO!lUaWN ORXAEUMNT4DRSPECIREDli00F'ZGNE a DIMENSION DEFINED PER ASCE 7.10 SHALL BE 4 FT REGARDLESS AS PER 2017 FLORIDA RESIDENTIAL CODE 6TH EDITION GABLE END BUILDING' HIP END BUILDING ROOF ROOF WIND AREA ZONES WIND AREA ZONES N TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE NONE 39" X 65" PHOTOVOLTAIC -- ALUM. SOLAR RAIL TYP 2 PLCS MODULE TYP. \ . ARRAY. TRS 1\ C TRS . k TRS SPLICE BAR (USE WHEN p I = SPLICE AT MID -SPAN W/ #12-1465" ST STL TRS C TRS - o - u R TA PING SCREWS TYpELF L LIMAX CANT. SEE SCHX­ ASPHALT SHINGLEST` ALUM L-FOOT - 76N DIA ST STL LAG BOLT TYP. SEE /METAL 5V ROOF TYP. FOR MAX SPAN REQ. TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN SCALE: 3"=1' 0" 2X I BETWI OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 IRONRIDGE XRI000 OR XR100 #12-14x8' ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL PER MODULE ARRAY AND BE CONNECTED LESS THAN 25% OF MODULE LENGTH IN ROOF ZONE 1ntN,ROOFzZONES,2-&-3-THREE(31:RAILS;AREREQUIREWER-MODULEARRAY. EMBEDMENT DEP IN THIS DETAIL. ALUM. L-FOOT FASTENED TO RAIL W/ 3/8-16 ST. STL. BONDING BOLT & NUT PV MODULE FRAME IRONRIDGE UFO CLAMP IRONRIDGE RAIL IRONRIDGE UFO CLAMP IRONRIDGE STOPPER SLEEVE PV MODULE FRAME OF tl`O�U`� nvivrvur dye �MODULETYP. ASPHALT SHINGLES/ METAL 5V ROOFING TYP. � SHEATHING - WOOD ROOF -' TRUSS TYP. IRONRIDGEXR1000 OR XR100 ALUM. SOLAR RAIL TYP. ry' ST STL LAG BOLT. SEE SCH FOR EMBED DEPTH REQ. TYP EACH L-FOOT TYPICAL PV L-FOOT CONNECTION DETAIL SCALE: 1 2"=1' 0" 3" a MID CLAMP - PLAN IRONRIDGE UFO CLAMP PV MODULE FRAME IRONRIDGE RAIL MID CLAMP - SIDE IRONRIDGE 1 UFO CLAMP PV MODULE FRAME IRONRIDGE STOPPER SL END CLAMP - PLAN END CLAMP - SIDE END & MID CLAMP CONNECTION DETAILS I PROJECT: I DATE 10-16-2019 29 DRAWN BY: JUL CHKD BY: JIA� RECORD A 29127 K SCALE: AS NOTED" R DRRAAWING# ��I,,�/7 110 T.K1�1R 7 E �1 Y - ai �J?Sur j TATE OF 777j111111111\\\\ POWER TABLE: SYSTEM I SYSTEM DC -SIDE A B C ISTBRNCH C 2NDBRN # PV MODULE 1 1 9 9 MANUF Q CELLS MODEL Q.PEAK DUO G5 295 W 2655W 2655 W POWER 325 WOO 290 W 2610 W 261 O W VOC 40.4 VDC 240 VAC 240 VAC 240 VAC ISC 10.1 A 1.21 A 10.89 A 10.69 A VMP 33.7 VDC 60 HZ 60 HZ 60 HZ IMP 9.7 AMP ENHWEDROP CABLE SYSTFAR SYSTEM A e PMSE LOT+ /9\ /, NCRONVERTERTYP. " V LED ONTERMINATORGRASEE GA Q ONB200FPIPXASE ENGAGE 3 GBU SYSTEn _ n L--. FNPHASE Q CPU E SYSEEM QA & ENPRASE DROP GBIESYSIFM SYSTEM B ON END OF ENPNASE ENGAGE GBU SYSTEM ,-, NEC 2014 LABELING REQUIREMENTS PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: 21.78 A MAXIMUM AC OPERATING VOLTAGE: 240 V IPE0.NEC6.-LTO DAEEXFEPNPLOL WSfDNX./M1NJ.l.EEPANRj.O,SNVICEPA D.L = IARPVRAPN.R1E' MAIN PV SYSTEM WARNING DEDICATED SOLAR PANEL DO NOT CONNECT ANY LOADS LABEL PER NEC 110.21 - PROVIDE AT NEW SUB PANELOR SERVICE PANEL (IF REQUIRED) V Q CUMSYSTFM AC -SIDE OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK INVERTER ENPHASE4Q7+ EQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL Q CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY . PEAK POWER CONT. POWER USTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC �110.3(B). ENPHASEMICROINVERTER SYSTEM IS RAPID SHUTDOWN COMPLIANT PER NEC 690.12. VOLTAGE CURRENT FREQUENCY TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2%OR LESS PER INVERTER MANUFACTURER. QLABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). CAUTION SOLAR ELECTRIC SYSTEM CONNECTED LABEL PER NEC 690.15 & NEC 690.13(B). PROVIDE AT NEW OR EXISTING SUB PANEL OR SERVICE PANEL PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL PER NEC 690.56(C)- PROVIDE AT NEW SUB PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN C INVERTEROUTPUIORCUTCURE QOUTDOOR CONDITIONS A HI#10 AWG, INSUTAfIOM THHN/TRWN-2 OR SLVJLAR 121 #10 AWG GROUND CONDUCTOR B'CONOUTMNwm INOOORCONDNONS I ROMEIGBU.N CA9 Oe EQUAL w/#IDmGRouuD F COMPUANTSYSTEMS. WARNING WARNING CAUTION DUAL POWER SOURCE ELECTRICSHOCK HAZARD. DO NOTTOUCH PHOTOVOLTAIC SYSTEM CIRCUIT TERMINALS. TERMINALS ON BOTH THE LINE WARNING IS BACKFED SECOND SOURCE IS PV SYSTEM AND LOAD SIDES MAY BE ENERGIZED IN THE INVERTER OUTPUT CONNECTION - DO NOT LABEL PER NEC 705.12(D)(34)&NEC 690.M 'A LABEL PER NEC 7B5.12(D)[3)&NEC IRI- OPEN POSITION RELOCATE THIS OVERCURRENT DEVICE PROVIDE AT NEW OR EXISTING SUB PANEL OR PROVIDE AT WIN SENCE PANEL OR TAP BOX LASELPER NEC 6RG12(EL- PROVIDE AT MAIN SERVICE PANEL LABEL PER NEC >Vi12I016ION- PROVIDE AT6WN SEANCE PANEL SERVICE PANEL LOCATION COMBINER 00X ONPN ORND CARE ONOOOR CONDRONS (2) a AWG, INSUTATIOM TIHN/NMN-2 OR SWW (2) #10 AWG, GROUND & NEUTRAL CONDUCTOR B•CONDUTMANWM NEWBOA RATED ENPHASE IQOOMBNER BOXIOREQLL4N CONNECIING TO UTILITY MOER (RENVERVBT NEW 6OA NONPLUSED LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. ��6oM� � Lo z � o PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. ENPHASE Q CABLE SHALL BE KEPT z" ABOVE ROOF SURFACE MINIMUM ZLENPRASE Q CABLE SYSTEM DOES NOT CONTAIN A NEUTRAL AND IS NOT REQUIRED MANUFACTURER. IQ7+MICROINVERTER DOES NOT REQUIRE EQUIPMENT BONDING FOR GROUNDING. SEE MANUFACTURER'S INSTALLATION MANUAL FOR DETAILS. J GROUNDING ELECTRODE SUPPLY SIDE CONNECTION OPTION TOUIIUTYGRID B401RLCIIONAL (TYP.) DIRTYN Ic XWHMETU &GROULDINGIFIECIRODE BOND # I O AW G CU TO EXISTING NDING EIECIRODE SUPPLY SIDE CONNECTION COMPLY WITH Lw NK 705.12(A) 60AMPFUSED OLSCONNECI. LOCATE AWG, 02SIMTOM THNN/2HWN2 OUTDOOR AS SHOWN CONDUT SM r A104IA ON SHEETSIRI. SHALL G BE SfeVICERATED ](2)#A(1)#10 EQWMEN IO DOWNER BOX OUTPUT GROUP (2) # 6 AWG, INSULATION: TIHN/IHW N-2 (2) # 10 AWG, GROUND & NEUTRAL COMUCTOR CONDUIT SQE 2"ANMNUM 0 NEW BOA RATED E PHASE IQ CONNNER BOX [OR EQUAL) 2G/2P OA/2P SYSTEM A SYSTEM BLgfl �� EETRJ _ O$ c UN .I NOR will y - a T * \A _ 91 Lli� ,�0 '. ATE OF �•g R6C7 - lOH O �\ '77,,/ OW- LAAAA