Loading...
HomeMy WebLinkAboutSOLAR INFORMATIONThe new Q.PEAK DUO-135 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. OAKUM'S world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding perfor- mance under real conditions— both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY �J Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.9%. QINNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. J ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID QCELMLS Technology', Hot -Spot Protect and Traceable Quality Tra.QTM.-To>IWAno>v- onrenr EXTREME WEATHER RATING '. 2017 High-tech aluminium alloy frame, certified for SCANNED high snow (5400Pal and wind loads (4000Pa). BY O t� A RELIABLE INVESTMENT St. Lucie Cou nt]/ Inclusive 12-year product warranty and 25-year linear ouamy Testes I performance warranty'. wmm am STATE OF THE ART MODULE TECHNOLOGY ID. An032§e] lam, J Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. r APT test conditions according to IEUTS 62804-1:2015, method B (-1500V, 168h) ' See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooltcparrayson Rooftop arrays an residential buntlin6s ` commercial/industrial ® bulltlings Engineered in Germany OC♦r r1 ELLS MECHANICAL SPECIFICATION Weight 18.7 kg Front Cover 3.2 man thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 x 20 monocrystalline O.AINTUM solar hall cells ]unction box 70-85mm x50-70mmx 13-21mm Protection class IP67, with bypass diodes Cable 4mma Solar cable; (+) 1100mm, (-) 1100mm Connector Multi -Contact, MC4, IP65 and IP68 IIvm Na.,I��Iso ELECTRICAL CHARACTERISTICS POWER CLASS 315 320 325 -- 330_ MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC'(POWER TOLERANCE+5W/-OW) Power at MPPa PWI IW] 315 320 325 330 Short Circuit Current- Ise [A] 10.04 10.09 10.14 10.20 E Open Circuit Voltage- Vp° IV] 39.87 40.13 40.40 40.66 Current at MPP• 1.11 [A] 9.55 9.60 9.66 9.71 Voltage at MPP• V.P, IV] 32.98 33.32 33.65 33.98 Efficiency' If [%] 218.7 219.0 219.3 219.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOCa Power at MPP' P.PP IW] 233.4 237.2 240.9 244.6 E Short Circuit Current' Is. [A] 8.09 8.14 8.18 8.22 e Open Circuit Voltage- Ve° IV] 37.30 37.54 37.79 38.04 f Current at MPP• lam W 7.51 7.H 7.60 7.64 Voltage at MPP• V." IV] 31.07 31.39 31.70 32.01 'lOOOW/m;25°B.spectrum AM 1.5G 'Measurement tolerances STC t3%; NOC t5% e80GWAa2. NOCT. spectrum AM 1.5G •typical values, actual values may differ O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE p" 5T e �E m 9 At least 98%of nominal power during X 10-"T-----r----"�---"�-""-" first year. Thereafter max. 0,54 % degradation per year. At least 93.1%of _ nominal power up to 10 years. At least " a 85%pf nominal power up to 25 years. t, m__-_____-_____�_____r____ All within measurement tolerances. 5 Fulll war warranties in accordance with the tt warrantyterms of year O ectWeELLS sales m organisation of your respective country. IPWW4IXCE IWM'1 >e Typical module performance under low Irradiance conditions In Wass comparison to STC condition(25°C, 1000W/m'). TEMPERATURE COEFFICIENTS Temperature Coefficient of I$e a I%/K] +0.04 Temperature Coefficient of Vm I1 [%/Kl -0.28 Temperature Coefficient of P., V I%/K] -0.37 Normal Operating Cell Temperature NOCT VC1 45 PROPERTIES"1' SYSTEM DESIGN Maximum System Voltage Van IV] 1000 Safely Class II Maximum Reverse Current le [A] 20 Fire Rating C Push/Pull Load [Pal 5400/4000 Permitted Module Temperature -40°C up to+85°C (Test -load in accordance with IEC 61215) On Continuous Duty QUALIFICATIONS 1 CERTIFICATES PARTNER VDE Quality Tested, IEC 61215 (Ed.2); IEC 61730 (Ed. 11. Application class A This data sheet complies with DIN EN 50380. EVE NOTE: Installation instructions must be followed. See the Installation and operating manual Or contact our technical service department for further Information on approved installation and use of this product. Namara OCELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wopen, Germany I TEL+49 (0)3494 66 99-234441 FAX+49 (0)3494 66 99-230001 EMAIL sales®q.cells.com I WEB www.q-ceils.com Engineered in Germany O "LLIEti Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The 107+ Micro is required to support 72-cell modules. `aaw ENPHASE. To learn more about Enphase offerings, visit enphase.com `/ Enphase IQ 7 and IQ 7+ Microinverters _I Commonly used module pairings' 235W-350W+ Module compatibility _ _ 60-cell PV modules only _235W-4_40W+ 60-cell and 72-cell PV modules Maximuminput DC voltage 48V 66V _ Peak power tracking voltage 27V-37V 27V-45V range 16 V-48 V 10 V-60 V _Operating _ _ _ _ Min/Max start voltage _ _ _ 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Ise) 15 A 15'A Overvoltage class DC port II II . DC port backfeed current _ 0 _A OA PV array configuration _ 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA _ _ Maximum continuous output power _ 240 VA _ 290 VA _ Nominal(L L)voltage/ranges �240V% 208V% 240V% 208V/ ' {- 211-264 V_ 211-264 V M_ aximum continuous output current _ 1.0 A (240 V) _183-229V 1.15 A (208 V) _ 121 A (240 V) _183-229V 1.39 A (208 V) '_Nominal frequency 60 Hz 60 Hz _ Extendedfreque-rcy-range 47-68Hz _ _ _ 47-68Hz __—_-._._______-... +_ A_C short circuit fault current over 3 cycles 5.8 Arms 5.8_Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) _ _ 13 (208 VAC) _ 13 (240 VAC) __ _ _ _ 11 (208 VAC) ' Overvoltage class AC port_ _ _ III AC port backfeed current GA 0 A Powerfactorsetting 1.0 10 __._—___. __.. Power factor (adjustable) Power ___ 0.851eading ... 0.85lagging 0.851eading ... 0.85lagging Peak efficiency 97.6 % 97.6 % 97.5 % _ 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA ,_Ambient temperature range_ -40°C to+65°C _ _ Relative humidity range 4% to 100% (condensing) ,._______. ____.f _ .___._.. Connectortype (IQ7-60-2-US&IQ7PLUS-72-2-US) _ MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connectortype (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxb) 212 mm x 175 mm x W.2 mm (without bracket) Weight 1.08 kg (2.38 Ibs) Cooling Natural convection -No fans Approved for wet locations Yes Pollution degree P63 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmenialcategory/UV exposure rating NEMA Type6/outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. ._ _ _ . .. __ Disconnecting means . _ _ ._..__ c_Wn __ _ _. _ _ _ _ _ _ _ _ .__ The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. Noenforced DC/ACratio. Seethe compatibility calculator at hhsps'//ennhas .omen�s/sunnort/module-compatibility. Nominal voltage range can be extended beyond nominal if required by the utility. imits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 'earn more about Enphase offerings, visit enphase.com u EN P HAS E. 9 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 1-19 The new Q.PEAK DUO-G5 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding perfor- mance under real conditions— both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. a ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for 1 high snow (540OPa) and wind loads (4000 Pa). O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. THE IDEAL SOLUTION FOR: Rooftoparra"on Roopoparrgra on residential buildings ®commercial/industrial buildings SCANNED BY St. Lucie County ■ ouaoty'restea w...wpmo� ID.40032567 ' APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) ' See data sheet on rear for further information. Engineered in Germany O CELLS SPECIFICATIONMECHANICAL Format 1685mm x 1000mmx32mm(including frame) Weight 18.7 kg _ °tl =m.s.. Front Cover 3.2mm thermally pre -stressed glass with anti -reflection technology r Back cover Composite film Frame Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells )unction box 70-85mm x50-70mmx 13-21mm Protection class IP67, with bypass diodes Cable 4mma Solar Cable; (+) 1100mm, I-) 1100 mm Canneclm Multi -Contact, MC4, IP65 and IP68 ° mm DU^li^ ELECTRICAL COARACTtRISTICS POWER CLASS 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +S W /-0 W) Power at MPPa Pore [W) 315 320 325 330 Short Circuit Current' Is, [A] 10.04 10.09 10.14 10_.20 _ E E Open Circuit Voltage- V., IV] 39.87 40.13 40.40 40.66 Current at MPP• fair [A] 9.55 9.60 9.66 9.71 Voltage at MPP• Vial IV] 3298 33.32 33.65 33.98 Efficiency' 8 [%] 218.7 219.0 219.3 i19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOCa Power at MPP' Purr IW] 233.4 237.2 240.9 244.6 E Short Circuit Current- Isa Al 8.09 8.14 8.18 8.22 e Open Circuit Voltage' Voa [VI 37.36 37.54 37.79 38.04 Current at MPP• [.,a [Al 7.51 Z56 7.60 7.64 Voltage at MPP` Varr [VI 31.07 31.39 31.70 32.01 '1000WAine C, spectrum AM 1eG 'Measuremem tolerances STCt3%; NOC i5% '800Whna,NOCT,spectrum AM 1.5G -typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during first year. Thereafter max. 0.54% degradation per year. At least 93.1%of nominal power up to 10 years. At least 85%of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. " is TEMPERATURE COEFFICIENTS Temperature Coefficient of ISs a [%/K] Temperature Co efficient of P., y [%/K] „° -------------------------- up, L----- L I m ac I I Ias I I a m ® ass es, IRRAOWICE worst Typical module performance under low irradiance conditions in comparison to STC conditions (25-C, 1OOOW/m9. +0.04 Temperature Coefficient of Ve, p [%/K] _ -0.28 -0.37 Normal Operating Cell Temperature NOCT [°C] 45 "I' 1' SYSTEM DESIGN Maximum System Voltage Vie IV] 1000 Safety Class II Maximum Reverse Current I, IA] 20 Fire Rating C Push/Pull Load [FBI 5400/4000 Permitted Module Temperature -40°C up to+85°C (Test -load in accordance with IEC 61215) On Continuous Duty I f]VE C NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hari Q CELLS GmbH Sentimenee 17-21, 06766 Hitterfeld-Wolten, Germany I TEL+49 (0)3494 66 99-234441 FAX+49 073494 66 99-230001 EMAIL sales®9-cells.com I WEE verve,cellai Engineered in Germany O CELLS Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) -The IQ 7+ Micro is required to support 72-cell modules. 1111901411111 ENPHASE. To learn more about Enphase offerings, visit enphase.cam �./ • Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module. pairings' 235 W_-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only -, 60-cell and 72-cell PV modules Maximum input DC voltage 46 V 60V _ Peak power tracking voltage _ _ 27V-37V - _ 27V-45V Operating range_ 16 V-48 V 16 V_- 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V M_ax DC short_circuit current (module Isc) 15A 15 A Overvoltage class DC port II _ _ II DC port bs_ckfeed en currt � 0 A PV array_confguration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power 250 VA 295 VA Maximum continuous output power 240 VA _ _ _ 290 VA Nominal (L-L) voltage/range' 240 V % 206 V / 240 V % 206V / ' V 183_-22_9 V 183-229 V Maximum continuous output current _211-264 1.0 A (240 V) _ _ _ 1.15 A (208 V) __211-264_V _ 1A (240 V) _ _ 1.39 A (208 V) Nominal frequency 60 Hz 60 .Hz _ Extended frequency range _ 47-68 Hz _ 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) _ 13 (208 VAC) _ _Arms 13 (240 VAC) 11 (208 VAC) overvoltage class AO port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.85 leading... 0.85 lagginq 0.85 leading... 0.85 lagging CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 MECHANICAL DATA temperature range -400C to+65°C _Am_bient Relative humidity range 4%to 100% (condensing) Connector type(IQ7-60-2-US&IQ7_PLUS-72-2-US_)_MC4(orAmphenol H4 UTX with add_itio_na_I Q-DCC_-S adapter) - Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 -PV2 to UTX: order ECA-S20-S25 : Dimensions (WxHxD) _ _ 212mm x 175 mm_ x 30:2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans , 4pro-v---...-t---- -- -------"-- Approvedforwetlocations ------ ------- ------ -- ----- - - Ves Pollution degree PD3 ._.______ Enclosure Class II double -insulated, corrosion resistant polymeric enclosure - - - -- Environmental category UV exposure rating ----- 67 -- -- — -- ... ----- -- - - NEMA Type6/outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require Installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break � disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741•SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed accordinq manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at httns�/lennhase.com/en-us/stinnort/mndtilp.compatibilily. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v E N P H A S E. © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19