Loading...
HomeMy WebLinkAboutFDS TRUSS PAPPERWORKIF 249 Maitland Ave., Suite )972 04841 E: i Springs. g. 32701 P: (321)972-0491 1 F: (321)972-0484 � E: info@fdseng.com Website: www.fdseng.com CA#9161 ENGINEERING. ASSOCIATES August 23, 2019 Building Department Ref: Adams Homes Lot: Lot 22 BI 61 Sec 8 Subdivision: Indian River Estates Address: 5613 Palm Drive Model: 2010-A-RHG KA # 19-5851 Truss Company: Date of drawings: Job No.: Wind Speed: Exposure: Truss Engineer: Builders First Source 8-15-19 2046337 160 B Joaquin Velez To whom it may concern, SCANNED BY St. Lucie County We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 8/23/2019 Carl A. Brown, P.E. FL. # 56126 01 01 101% FILE COP` ♦�♦o�ae sau„� , 0os�00D M. ® Q. aoo r�xCE/yS;F,:y: iVo 20�9 v� :# � : Tl�a `rn, 9�JE ' i "Doing Business with a Service Mindset and an Eye for Detail" =.�ntID ♦� Cf /lNAl- �`� DPP/Psa�oa`��� Page 1 of 1 It b]-00-a0 19-00-00 '7I�'I U U U ^' L) U U C1 C3 C5 b �. ' O m N O m m O m 03 m H O m D N O m O Q Yn N O Q -oo-a CJ O Q V O Q O O Q O O Q n O Q a0 O Q DalinY 1 a a 1 4-00- N '� 'I- Cl 3 C5 T-oo-oo 7-00-00 C Cl— Ct OT A'.g 11 1� D O• 111 e 11 a o N 11 Dl 3 l /ice 031 Y m 1-0 -04 —` n D N_ r W X D .o-e 11 11 11 If A ae m an O D05 D05 005 Q 6'-0• expcu LG d to ind U U U C1 RGYICWCV -•••y_ - q13��tt�f1��t��11��pp C3 I) d REVIEWED WITH NOTATI (SEE EX IEAT OPt) Corrections or comments made on equipment submittals 4 or shop drawings during this review do not relieve con- tractor from compliance with requirements of the draw' -ngs and specifications. This check Is only for review of general conformance with the design concept of the c=c)ect and general compliance with the information given :=1 the contract documents. The contractor Is responsible C3 confirming and correlating all quantities and dimen' �;;ins; selecting fabrication processes and techniques of C1 _ . f all other e'-0'CLG D03 Doi D02 D01 CS C3 1 K 7(4 y� =odes and performing his work in a safe and satisfactorY oannar p U U J U U 12-08-00 22-04-(10 20-00-00 I'LUKIDAa 55-00-00 f_ / Ud1C 0 ) --- Died No. Pfgact ft,__ hike DW'� SCANNED BY St. Lucie County v .0 .... pwonom Hi ".. . sase cca,mm.re„a �auffoln.eano.aan eua� samenceamoawnwcema .. ce'-u IsAsEOO IMPORTANT .CalE0O0.V< ass.l.sseacen This Drawing Must Be APPmend And Ao oomaes a.amwaar.. .Iova Returned Before Fabrication Will rsranaran rsr wneu owarao Loin . wvE oaucao Your Check Ail xaaarcwamvnmwmasraausasam Damn. ion Dimensions And Contlitlona Prior To Conditions ApPmwl Of Plen. SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES AND DIMENSIONS HAVE TCLL: 20 PSF TOLL: 40 PSF BEEN ACCEPTED. TOOL: OT PSF TOOL: 10 PSF BCDL: 10 PSF BLDL: 5 PSF By Dab_ TOTAL: 37 PSF TOTAL: 55 PSF DURATION: 1.25 DURATION: 1.00 CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCLBI SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES (le. SHEATHING, SNNGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEER FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 21 BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) d) UPLIFT AND GRAVITY REACTIONS WARMING BackchaMes will Not Be Accepted Regardless of Fault Without Prior Notifica8on By Customer WAhln 48 Hours And Inesstlgo6on By Builders First Source. NO EXECPTIONS. The Generel Contractor Is W sPonsibla For All Co radians Other Than Tiues to TNsa, Goals Shaer Wall, And Connections. Temporary and Permanent Bracing, And Coiling And Roof Diaphragm Conn..ders. ROOF PITCH: W12 CEILING PITCH: 3112 TOP CHORD SRE: 2 X 4 BOTTOMCHORDS2E 2X4 OVERH/WG LENGTH: IV ENDCUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BNIDING CODE: FBC201T BEARING HEIGHT SCHEDULE BUILDER: - Adams Homes PROJECT. Single Family MODEL: 2010 A 1 OX20 LANAI ADDRESS: 5613 PALM DR LOT/ BLOCK: I 2V61/8 SUBDMSION: CITY: FORTPIERCE DRAWN BY: KTEUBER JOB 8: 2046337 IMsa019 DALE: SCALE: NTS PLANDAM-1 2019 REMSION3: I: a. 3. 4. �, Bl llld@t'S .FirstSource "a M,.d Road Plant City, FL 33563 Ph.(813) 305-1300 Fax (813) 305-1301