Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 SCANNED BY St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SWEENEY RESIDENCE Builder Name: Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNT' JAN 2 4 P029 City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: JOHN SWEENEY Jurisdiction; ST LUCIE COUNT" ST. Lucie County, Permitting Design Location: FL, Fort Pierce County: St. Lucie (Florida Cl rate Pone 2 � 1. New construction or emsting New (From Plans) 9. Wall Types (1568.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1568.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1440.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1440.00 ft2 6. Conditioned floor area above grade (ft2) 1440 b. NIA R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft2 11. Duds R ft' 7. Windows(137.5 sqft.) Description Area a. Sup: Attic, Rel: Attic, AH: MUOROOM 6 140 a. U-Factor: Sgl, U=0.85 84.13 ft2 SHGC: SHGC=0.40 b. U-Factor: Sgl, U=0.69 53.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.330 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1440.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1440.00 %' b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.095 Total Proposed Modified Loads: 52.11 PASS Total Baseline Loads: 54.55 I hereby certify that the plans and specifications covered by Review of the plans and O this calculation are in compliance with Code. the Florida Energy specifications covered by this e+ - calculation indicates compliance �.Q[/�yi��L with the Florida Energy Code. PREPARE 2 ,� 1K3C � Beforeconstruction �`�""� DATE: 1 4 be inspected fO compliance with Section 553.908 I hereby certify that this i , aIdgned, is in compliance Florida Statutes. with the Florida Energy. OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). F11A 60py 1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT TiOe: SWEENEY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1440 Lot # Owner Name: JOHN SWEENEY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1440 13392 SPACES Number Name Area Volume Kitchen Occupants Bedrooms In9I ID Finished Cooled Healed 1 BEDROOM 3 151 1404.3 No 0 1 1 Yes Yes Yes 2 CLST 3 14 130.2 No 0 1 Yes Yes Yes 3 LAUNDRY 42 390.6 No 0 1 Yes Yes Yes 4 LINEN a 74.4 No 0 1 No Yes Yes 5 CLST2 18 167.4 No 0 1 Yes Yes Yes 6 BEDROOM 2 151 1404.3 No 0 1 1 Yes Yes Yes 7 BATH 2 45 418.5 No 0 1 Yes Yes Yes 8 MUDROOM 45 419 No 0 1 Yes Yes Yes 9 HALLWAY 48 446.4 No 0 1 No Yes Yes 10 LIVING 177 1646.1 No 0 1 Yes Yes Yes 11 DINING 144 1339.2 No 0 1 Yes Yes Yes 12 KITCHEN 165 1534.5 Yes 0 1 Yes Yes Yes 13 FOYER 72 669.6 No 0 1 Yes Yes Yes 14 MASTER BEDROO 206 1906.5 No 0 1 1 Yes Yes Yes 15 M WIC 2 25 232.5 No 0 1 No Yes Yes 16 M WIC 1 25 233 No 0 1 Yes Yes Yes 17 M BATH 105 977 No 0 1 Yes Yes Yes V23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 24 It 0 151 ft2 1 0 0 2 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 14 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation LAUNDRY Eft 0 42 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation LINEN t ft 0 8 ft2 ___ 1 0 0 5 Slab -On -Grade Edge Insulation CLST 2 2ft 0 18 ft2 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 2 24 It 0 151 ft2 __ 1 0 0 7Slab-On-Grade Edge Insulation BATH 2 511 0 45 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulation MUDROOM 5 ft 0 45 ft2 __ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 48 ft2 I __ 1 0 0 1081ab-On-Grade Edge Insulation LIVING 12 ft 0 177 ft2 ___ 1 0 0 11SIab-On-Grade Edge Insulation DINING 12 ft 0 144 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 14it 0 165 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation FOYER 8 ft 0 72 ft2 __ 1 0 0 14SIab-On-Grade Edge Insulation MASTER BEDRO 27 ft 0 205 ft2 1 0 0 15SIab-On-Grade Edge Insulation M WIC 2 1 ft 0 25 ft2 ___ 1 0 0 16SIab-On-Grade Edge Insulation M WIC 1 5ft 0 25 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation M BATH 22 It 0 105 ft2 ___ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emift Emifl Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1560 ft2 0 ft2 Light N 0.3 No 0.9 No 0 22.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1440 ft2 N N 1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 3 30 Blown 151 W 0.1 Wood 2 Under Attic (Vented) CLST 3 30 Blown 14 ft2 0.1 Wood _ 3 Under Attic (Vented) LAUNDRY 30 Blown 42 ft- 0.1 Wood _ 4 Under Attic (Vented) LINEN 30 Blown 8ft2 0.1 Wood 5 Under Attic (Vented) CLST2 30 Blown 18 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 151 ft2 0.1 Wood _ 7 Under Attic (Vented) BATH 2 30 Blown 45 ft2 0.1 Wood _ 8 Under Attic (Vented) MUDROOM 30 Blown 45 ft2 0.1 Wood _ 9 Under Attic (Vented) HALLWAY 30 Blown 48 ft2 0.1 Wood _ 10 Under Attic (Vented) LIVING 30 Blown 177 ft2 0.1 Wood _ 11 Under Attic (Vented) DINING 30 Blown 144 ft2 0.1 Wood _ 12 Under Attic (Vented) KITCHEN 30 Blown 165 ft2 0.1 Wood _ 13 Under Attic (Vented) FOYER 30 Blown 72 ft2 0.1 Wood _ 14 Under Attic (Vented) MASTER BEDRO 30 Blown 205 ft2 0.1 Wood 15 Under Attic (Vented) M W IC 2 30 Blown 25 ft2 0.1 Wood _ 16 Under Attic (Vented) MWIC1 30 Blown 25W 0.1 Wood 17 Under Attic (Vented) MBATH 30 Blown 105 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 S Extedor Concrete Block - Int InsuBEDROOM 3 4 11 0 9 4 102.7 112 0 0 0.3 0 _ 2 W Exterior Concrete Block - Int InsuBEDROOM 3 4 13 0 9 4 121.3 ft2 0 0 0.3 0 _ 3 W Exterior Concrete Block - Int Insul CLST 3 4 2 0 9 4 18.7 ft2 0 0 0.3 0 _ 4 W Exterior Concrete Block - Int Insul LAUNDRY 4 6 0 9 4 56.0 ft2 0 0 0.3 0 _ 5 S Exterior Concrete Block- Int Insul CLST 2 4 2 0 9 4 18.7 ft2 0 0 0.3 0 _ 6 E Exterior Concrete Block - Int InsuBEDROOM 2 4 13 0 9 4 121.3 ft2 0 0 0.3 0 _ 7 S Exterior Concrete Block- Int InsuBEDROOM 2 4 11 0 9 4 102.7 ft2 0 0 0.3 0 _ 8 E Exterior Concrete Block - Int Insul BATH 2 4 5 0 9 4 46.7 f12 0 0 0.3 0 9 E Exterior Concrete Block- Int InsuIMUDROOM 4 5 0 9 4 46.7 fN 0 0 0.3 0 _ 10 W Exterior Concrete Block- Int Insul LIVING 4 12 0 9 4 112.0 ft2 0 0 0.3 0 _ 11 W Exterior Concrete Block- Int Insul DINING 4 12 0 9 4 112.0 ft2 0 0 0.3 0 _ 12 E Exterior Concrete Block- Int Insul KITCHEN 4 14 0 9 4 130.7 ft2 0 0 0.3 0 _ 13 E Exterior Concrete Block- Int Insul FOYER 4 8 0 9 4 74.7 fN 0 0 0.3 0 _ 14 N Exterior Concrete Block- Int InsuMASTER BE 4 12 0 9 4 112.0 ft2 0 0 0.3 0 _ 15 W Exterior Concrete Block - Int InsuMASTER BE 4 15 0 9 4 140.0 ft2 0 0 0.3 0 _ 16 N Exterior Concrete Block - Int Insul M WIC 1 4 5 0 9 4 46.7 ft2 0 0 0.3 0 _ 17 N Exterior Concrete Block- Int Insul M BATH 4 7 0 9 4 65.3 ft2 0 0 0.3 0 18 E Exterior Concrete Block - Int Insul M BATH 4 15 0 9 4 140.0 ft2 0 0 0.3 0 1/23/2020 6:40 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 E Insulated FOYER None .27 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 _ 2 3 _ 4 5 6 W 2 Vinyl Low-E Single E 6 Vinyl Low-E Single W 10 Metal Low-E Single E 12 Vinyl Low-E Single W 15 Vinyl Low-E Single E 18 Vinyl Low-E Single Yes 0.85 0.4 Y 22.0 ft' 2 ft 0 in 0 it 14 in Yes 0.85 0.4 Y 22.0 ft' 2 ft 0 in 0 ft 14 in Yes 0.69 0.22 Y 53.3 ft2 2 ft 0 in 0 ft 23.51 Yes 0.85 0.4 Y 9.0 ft' 2 ft 0 in 0 ft 14 in Yes 0.85 0.4 Y 22.0 ft2 2 ft 0 in 0 ft 14 in Yes 0.85 0.4 Y 9.0 ft2 2 It 0 in 0 It 14 in None None Drapes/blinds None None None None None Exterior 5 None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 1562.6 85.78 161.33 .1523 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UnlV Split Single SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None MUDROOM 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / V # — Supply-- Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 140 ft2 Attic 14 ft' Default Leakage MUDROOM (Default) c(Default) c 1 1 1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programablef N Ceiling Fans: xThermostat:X� Heal ng Jan Feb Mar Apr�X Jun [ � Jul r I [X] Aug fX [ Sep [ ] L 1 Oct fr Dec Venting [ ]Jan I l l l l Feb X Mar Apr [ May, l 1 Jun I Jul [ 1 Aug I Sep Ixl Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(B lbs/sq.ft. 0 ft2 0 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 SUN ROOM Default(81bs/sq.ft ft2 ft 0.3 GREAT ROOM Default(8 lbs/sq.R. fP ft 0.3 LINEN Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8 lbs/sq.ft. 112 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 It 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 OFFICE CLST Default(8 lbs/sq.ft. ft2 ft 0.3 OFFICE Default(8 lbs/sq.ft, ft2 ft 0.3 WIC Default(B lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOMS LIVIN Default(81bs/sq.fL ft2 ft 0.3 M WIC Default(8 lbs/sq.R. ft2 ft 0.3 HALL Default(8 Ibs/sq.fL ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M TOILET Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(B lbs/sq.ft. ft, ft 0.3 WIC3 Default(8 lbs/s.ft. ft2 It 0.3 BEDROOM 3 1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD fix - - i I JAN 2 4 2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ST. Lucie County, Permitting i ESTIMATED ENERGY PERFORMANCE INDE - " - The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12, Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location MUDROOM 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned Floor area (sq. ft.) 6. 1440 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.788 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.330 c) Area 7c. 137.5 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be inst led (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be complet b d on installed code compliant features. fit' Builder Signature: Date:, Address of New Home: TREETOPTRAIL City/FL Zip: FORT PIERCE, FL 34951 1123/2020 6:40:44 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERI RECEIVED TABLE 402.4.1.1 JAN 2 4 2020 AIR BARRIER AND INSULATION INSPECTION COMPONEN CRITERIA Project Name: SWEENEY RESIDENCE Builder Name: Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Y Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the lop plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking,or floor framing g cavity insulation shall and cantilevered floors be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Dud shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or Insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to rill voids between fire sprinkler cover olates and walls or ceilings. a. in aaamon, inspection or log watts shall be in accordance with the provisions of ICC-400. 1/23/2020 6:40 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 SCANNED ® Project SummaryBY Job: -I Wrightsoft te: May17,2019 Entire House St. Lucie Countv By QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Favc T72466-6796 Email: QUICKCALCS AOL.COM For. SWEENEY RESIDENCE TREE TOP TRAIL, FORT PIERCE, FL 34951 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TO Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TO Daily range Relative humidity Moisture difference Heating Summary Structure 18862 Btuh Ducts 4277 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23139 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He Co Area (ft)z 12 1 Volume (fta) 13392 13392 Airchangesfhour 0.45 0.23 Equiv. AVF (cfm) 100 51 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 6.4 kW 21711 Btuh 20 OF 1000 cfm 0.043 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 M OF 50 % 61 gdlb Sensible Cooling Equipment Load Sizing Structure 15987 Btuh Ducts 6273 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Equipment sensible load 21147 Btuh Latent Cooling Equipment Load Sizing Structure 4145 Btuh Ducts 1671 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5815 Btuh Equipment Total Load (Sen+Lat) 26962 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1630AJ1NA Coil RH1T3621MTANJA AHRI ref 7941344 Efficiency 13.0 EER, 16 SEER Sensible cooling 21000 Btuh Latent cooling 9000 Btuh Total cooling 30000 Btuh Actual air flow 1000 cfm Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.79 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r p- wrljLI ft- 1� {^1 �'�N-� 2019-May-17 13:00:51 •^ Right -Suite® Universal 2018 18.0.31 RSU08101 FWD- D- s V' Page 1 ACCKEADocunnetsMaghtsoft HVAC\SWEENEY RESIDENCE.rup Cale =MJ8 Front Door faces: E FILE COPY I F wrightsotV Right-)@ Worksheet Job: Entire House Date: May 17, za19 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 3 2 Exposed wall 168.0 ft 24.0 It 3 Room height 9.3 ft 9.3 ft heaUcool 4 5 Room dimensions Room area 1440.0 ft' 1.0 x 151.0 ft 151.0 ft' Ty Construction 1-1-value Or HTM Area (ft') Load Area (ft� Load number (BtutVftk'F) (Btuwftg or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cad Gas N/P/S Heat Cool Gross WP/S Heat- Cool 6 . W 1� 13A4ccs 13AAccs 0.143 0.143 n a 4.00 4.00 219 219 223 558 223 504 894 2018 488 1102 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 25 0 455 844 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 31.52 9 1 164 284 0 0 0 0 11 11130 0.390 a 10.92 10.34 20 20 219 208 0 0 0 0 W v+/ 134-4acs 13A4ccs 0.143 0.143 s w 4.00 4.00 219 219 223 558 223 472 894 1891 488 1034 102 121 102 105 .,. 410 420 _ — _224 230 2 glazing, clr low-e 0.650 w 18.20 33.77 32 0 582 1081 16 0 291 540 ��(C' 2 alazino. clr low-e 0.650 w 18.20 25.40 54 0 976 1362 0 0 0 0 C 161380md 0.032 - 0.90 1.60 1440 1440 1290 2304 151. 151 _ _ 135 . .w 242 F 22A-toh 1.358 - 38.02 0.00 1440 168 6388 0 151 24 913 0 6 c)AED excursion 5% 173 Ernelope loss/gain 15771 9791 2169 1409 12 a) Infiltration 3091 846 442 121 b) Roomventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 5350 0 Subtotal (lines 6 to 13) 18862 15987 2510 1530 Less e#ernal load 0 0 -0 0 Less transfer 0 0 0 0 Redistribution 0 0 214 91 14 Subtotal 18962 15987 2824 1621 15 Duct loads 1 231/6 39% 4277 6273 23% 39% 640 636 Total. load 23139 22260 3465 2257 Air required (cfm) 1000 1000 150 101 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. M}F wrrghesofe- 2019-May-1713:00:51 AMA Right -Suite) Universal 2018 18.0.31 RSU08101 Page 1 E:\Dmumets\WrightsoftHVAC\SWEENEYRESIDENCE.mp Calc=MJ8 Front Doorfaces: E wrightsofr RighWO Worksheet Job: Entire House Date: May 17, zols By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Far. 77246645796 Email: OUICKCALCS@AOL.COM 1 Room name CLST3 LAUNDRY 2 Exposed wall 2.0 ft 6.0 it 3 Room height 9.3 ft heat/cool 9.3 It heat/cool 4 Room dimensions 2.0 x 7.0 ft 6.0 x 7.0 ft 5 Room area 14.0 ft- 42.0 fR Ty Coretmction U-value Or HTM rea Aqt� Load Area (ft2) Load number (BtuMWl') (Btu)Vft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P!S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 0.143 In 4.00 Z19 0 0 0 0 0 0_ 0- '0 0 13A-4ocs 0.143 a 4.00 2-19 0 0 0 0 0 0 0 2 glazing, clr lcw-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 1i 2 glazing, clr lowe 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 w 1344ocs 0.143 s 4..00 219 0 0 -0 - 0 -- 0' -- 0 -.' ',0 _. :-.A 13A4ocs 0.143 w 4.00 219 19 19 74 41 56 56 223 122 2 glazing, clr lowe 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 olmm. clr lowe 0.650 w 18.20 25.40 0 0 0 0 0 0_ 0 0 C _ 1fiB30md 0.032 0.90 1.60 14 14 13 22 42 - - _-_42 _ _ 38 ....- _67. F 22A-toh 1.358 - 38.02 0.00 14 2 76 0 42 - 6 228 - 0 61 c)AEO emursion -3 -25 Envalope loss/gain 163 61 1 489 164 12 a) hfilbation 37 10 110 30 b) Roomvantilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal(lims 6to 13) 200 71 600 695 Less extemal load 0 0 -0 0 Less transfer 0 0 0 0 Redistribution -200 -71 96 46 14 Subtotal 0 0 696 741 15 Duct bads 23% 39% 0 0 23% 39% 158 291 Total mom load 0 0 854 1032 Air required(cfm) 0 0 37 46 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrrgtieso>Pe- 2019-May-1713:00:51 .4C�A ISWEEuiEY U SIDE I E.w 18.Cao RSU08101 Page 2 E:1Documnets\Wrightsofl HVAC1SWEENEV RESIDENCE.mp CaIc=MJB Front Door faces: E r�t wrightsoftr Right-M Worksheet Job: Entire House Date: May 17, 2019 By: QUICK CALCS, INC. 317 Sr LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM i Room name LWEN CLST 2 2 Eked wall 0 ft 2.0 It 3 Room height 9.3 ft heat/cool 9.3 It heat/cod 4 Room dimensions 2.0 x 4.0 It 9.0 x 20 It 5 Room area 8.0 ft. 18.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (BtulVft2-F) (BtuWff2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cad Gross N/P(S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 219 0 0 0 0 0 0 0 0 2 glazing, clr lows 0.650 a 18.20 33.7 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 11D0 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 W .13A-4ws 0.143 s _ 4.00 2.19 0 0 0 0 19 19 - _ _ 74 ____ - 41 Vy 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr Iwe 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 ::G 2 alazina. clr lowe 0.650 w 18.20 25.40 0 0 0 0 0 0 0 0 C 1613-30md 0.032 - 0.90 - 1.60 8 8 7 13 18 -_-18 _ _ .16 �. -._.29 F 22A-toh 1.358 38.02 0.00 8 0 0 0 18 2 -76 0 6 c)AED excursion 0 3 Envelope loss/gain 7 12 167 67 12 a) Infiltration 0 0 37 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 7 12 203 77 Less external load 0 0 0 0 Less transfer 0 0 -0 0 Redistribution -7 -12 -203 -77 14 Subtotal 0 0 0 0 15 Duct loads ' 23% W/o0 0 231 39% 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2019-May-17 13:00,51 A&K RightSuite@ Universal 2018 18.0.31 RSU08101 Page 3 E:1Docurmets\Wrightsoft HVAC\SWEENEV RESIDENCE.rup Calc=MIA Front Door faces: E +wrightsoft, Right-MWorksheet Job: Entire House Date: May 17, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6795 Emil: OUICKCALCS@AOL.COM 1 Room name BEDROOM 2 BATH 2 _ 2 Evosed wall 24.0 it 5.0 ft 3 Room height 9.3 it heaticool 9.3 It heat/coot 4 Room dimensions 1.0 x 151.0 ft 5.0 x 9.0 R 5 Room area 151.0 f 2 45.0 ft2 Ty Coretruction U-Nelue Or HTM Area (ft) Load Area (ft-) Load number (BtuNft2-'F) (Btu)Vft2) or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 w 13A-4ocs 0.143 n 4.00 219 0 0 0 0 0 0 ---0- 0 % 13A-4ocs 0.143 a 4.00 219 121 105 420 230 47 47 186 102 2 glazing, clr low-e 0.650 a 18.20 33.77 16 0 291 540 0 0 0 0 IIL--GGD glazing, cir low-e 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 110 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 w 13A-0acs 0.143 s 4.00 219 102 .102 410 224 0 _ _ 0. _ 0 0 Y)/ 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 _- 0 _ 0 0 IL-IGi 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 eladm. clr low-e 0.650 w 18.20 25.40 0 0 0 0 0 0 0 0 C 161330md 0.032 - 0.90 , 1.60 151 151 _ 135. 242 - 45 __ __45 __ __ 40 . ..72 F. 22A-toh 1.358 - 38.02 0.00 151 24 _ 913 0 45 . _ 5 _ 190 _ _ 0 6 c)AED excursion -26 -7 Envelope loss/gain 2169 1209 417 167 12 a) Infiltration 442 121 92 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 250 0 Subtotal (fines 6to 13) 2610 1580 509 192 Less ex4emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 119 54 - 8 14 14 Subtotal 1 2729 1634 517 2D6 15 Duct loads 23% 39% 619 641 23% 39% 117 81 Total room load 3347 2275 634 287 Air required (cfm) 145 102 27 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ A -PP- w�lghGsofc- 2019-May-1713:00:51 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 4 EADocurrnets\Wdghtsoff HVAC1SWEENEY RESIDENCE.rup Calc=MJ8 Front Door faces:E I{� wrightsoft, Right-M Worksheet Job: Entire House Date: May 77, zols By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724666796 Email: QUICKCALCS@AOL.COM 1 Room rlame MUDROOM HALLWAY 2 Flposed wall 6.0 it 0 It 3 Room height 9.3 It heat/cool 9.3 ft heat/cod 4 Room dimensions 5.0 x 9.0 It 1.0 x 48.0 It 5 Room area 45.0 ft- 48.0 W Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (BWIV °-°F) (Btuhrft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) He; Cod Gross N/PIS Heat Cool Gress N/PIS Heat Cool 6 W 13A4acs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 - - 0 13A-0acs 0.143 a 4.00 2.19 47 47 186 102 0 0 -0 0 2 glazing, clr lowe 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr Iov-e 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.1919 0 0 0 0 - 0 _ __-0 _ 0 _ _ 0 _ _ _.. -0 lql 13A-4= 0.143 w 4.00 219 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 L�—GC 2 alazina. dr Iowe 0.650 w 18.20 25.40 0 0 0 0 0 0 0 0 C 16B-30mtl- 0.032 - 0.90 1.60 45 45 40 - 72 _ -48- _ 48 ___ 43 __ __77 F 22A-toh 1.358 - 38.02 0.00 45 5 190 0 48 0 0 0 6 c)AED mursion -24 -3 Es lope loss/gain 417 150 43 74 12 a) Infiltration 92 25 -a 0 b) Rcomventilation 0 0 0 0 13 hand gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6to 13) 509 675 43 74 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 -03 -74 14 Subtotal 514 683 0 0 15 Duct loads 23% 39346 116 269 23% 39% 0 0 Total room load 630 952 0 0 Air rec ired(din) 27 43 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -pj' wr�gtibo_M 2019-May-1713:00:51 A Right -Suite® Universal 2018 18.0.31 RSU08101 Page 5 E:\Docurmets\Wnghtsofl HVAC\SWEENEY RESIDENCE.rup Calc=MJB Front Door faces: E wrightsofC Right-M Worksheet Job: Entire House Date: May 17, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM 1 Room name LIVING DINING 2 E1ylosed wall 12.0 ft 120 ft 3 Room height 9.3 It heat/cool 9.3 ft heat/cod 4 Room dimensials 1.0 x 1T7.0 ft 12.0 x 120 ft 5 Room area 177.0 ft' 144.0 W Ty Construction U-value Or HTM Area (ft.) Load Area (W) Load number (BtuWfti°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 W 13A-0ocs '0.143 n 4.00 219 0 0 0 0 0 0 0 0 13A-0ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 _ -0 _. 0 2 glazing, clr lowe 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13AAccs 0.143 a 4.00 219 0 0. 0 0 0. 0 0-- 0 V+/ 134-0acs 0.143 w 4.00 219 112 58 232 127 112 112 447 244 ��-CC 2 glazing, clr low-e 0.650 W 18.20 33.77 0 0 0 0 0 0 0 0 2 olazino. clr low-e 0.650 w 18.20 25.40 54 0 976 1362 0 0 0 0 C 166<10md 0.032 - 0.90 1.60 177 . 177 159 283 _ 144 _ . _144 _ _ _ 129 - 230 F 22A-toh 1.358 - 38.02 0.00 177 12 456 0 144 12 456 - 0 6 c)AED elxursion 578 -56 Envelope loss/gain 1823 2349 1032 418 12 a) Infiltration 221 60 221 60 b) Roomvemilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1100 Subtotal(lines 6to 13) 2043 2410 1253 1579 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 20 0 0 14 Subtotal 2055 2430 1253 1579 15 Duct loads 23% 39% 466 953 230/6 39% 284 619 Total room load 2521 3383 1537 2198 Air required (cfm) tog 752 66 99 Calculations approved byACCAto meet all requirements of Manual J 8th Ed 2019-M_ ay-1713:00:51 RIghlSuite® Universal 2018 18.0.31 RSUD8101 AEADocunnets\Wrighlsoft WACISWEENEY RESIDENCE.mPage 6p Calc=MJ8 Front Door loons: E - i wrightsoft• Right-M Worksheet Job: Entire House Date: May 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: T724GM799 Fax 772466-6796 Emil: OUICKCALCS@AOL.COM 1 Roan name KITCHEN FOYER 2 F)Wosed wall 14.0 ft 8A ft 3 Room height 9.3 ft heat/cool 9.3 0 heaticoal 4 5 Room dimensions Room area 1.0 x 165.0 ft 165.0 R' 8.0 x 9.0 ft 720 ft' Ty Construction U-velue Or HTM Area M Load Area (ft-) Load number (BIUVIt °F) (BtulJf 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W y/ 13A flocs 13AAocz 2 glazing, Gb r we 0.143 0.143 0.650 n a a 4.00 4.00 1820 219 219 33.77 0 130 9 0 121 0 0 485 164 0 265 304 0 74 0 _ -0 54 0 _ 0_ 217 -0 _-0 119 0 III----,--GGD 11 glazing,110 clr low-e 0.650 0.390 a a 18.20 10.92 31.52 10.34 0 0 0 0 0 0 0 0 0 20 0 20 0 21.9 0 W Yil It--GG 13A4acs 13A4ocs 2 glazing, clr loa2 0.143 0.143 0.650 s w w 4.00 4.00 11120 219 219 33.77 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 _ 0 0 0 _ _ 0___ 0 0 _20B _- 0 0 0 C 2 alazina. clr lave 161330md 0.650 0.032 w 18.20 0.90 25.40 1.60 0 165 0 165 0 _ 148 0 264 0 _ _ 72 0 _--.72. 0 -_ 65 0 _-. __ 115 F 22A-toh 1.358 - 38.02 0.00 165 14 532 0 72 8 304 0 6 c)AED excursion 1-49 -37 Envelope loss/gain 1329 784 806 404 12 a) Infiltration 258 71 147 40 b) Room ventilation 0 0 - 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 600 Subtotal (Iirxs 6 to 13) 1587 1WA 953 1045 Less e#emal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1587 0 0 1354 0 0 953 0 0 1045 15 Duct loads 23% 39% 360 728 23% 39% 216 410 Total room load regL imd (cfm) 1984 21116 1151 14� Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrl9ti�oP!- 2019-May-1713:00:51 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 7 E:1DacumnetslWdghtsofl HVAC\SWEENEYRESIDENCE.mp Calc=MJB Front Doorfaces: E wrightsofr Right-M Worksheet Job: Entire House Date: May 17, zote By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M W IC 2 2 Exposed wall 27.0 it 0 It 3 Room height 9.3 It heaticool 9.3 It heat/coot 4 Room dimensions 1.0 x 205.0 ft 5.0 x 5.0 ft 5 Room area 205.0 ft2 25.0 ft2 Ty Construction U-value Or HTM Area qft Load Area (ft-) Load number (Bluh/ftMF) (Btuh/ftl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W�l 13A-4= 0.143 n 4.00 219 112 112 447 244 0 0 0 0 1 13AAocs 0.143 a 4.00 219 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 a 18.20 33.77 0 0 0 0 0 0 -0 0 h 2 glazing, dr low-e 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13AAccs 0.143 s 4.00 219 0 0 0 0 0 0 _ 0._ 0 y/L 13A-0ars 0.143 w 4.00 219 140 124 494 270 0 0 0 0 �(C' 2 glazing, clr lcw-e 0.6W w 18.20 33.77 16 0 291 540 0 0 0 0 2 clazino, clr low_-e 0.650 w 18.20 25.40 0 0 0 0 0 0 0 0 C 16&30md 0.032 - 0.90 1.60 205 205 184 328 25 . _ .- _25 ._ . _-. .22 _ _ 40 F 22A-toh 1.358 - 38.02 0.00 205 27 1027 0 25 0 0 0 6 c)AED excursion 120 -1 Envelope loss/gain 2443 1502 22 39 12 a) Infiltration 497 136 0 0 b) Roomventilation 0 0 -0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 1400 0 Subtotal (lines 6 to 13) 2940 3038 22 39 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2940 3038 22 39 15 Duct loads 235/6 39 % 667 1192 23% 39% - 5 15 Total room load 1 3606 4230 27 54 Air required (cfm) 156 190 1 2 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. _ -PI- wrrg!>1boFe- 2019-May-17 13:00:51 ACCA RlghtSuite® Universal 201818.0.31 RSU08101 Page 8 EADocuneets\Wrightsoft HVACISWEENEY RESIDENCE.rup Cale = MJ8 Front Door faces: E - wrightsogr Right-M Worksheet Job: Entire House Date: May 17, 2019 QUICK CALCS, INC. By- 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fan 772AGG-6796 ErnaiC OUICKCALCS AOL.COM 1 Room name M W IC 1 M BATH 2 F)posed wall 5.0 It 22.0 ft 3 Room height 9.3 It heaticool 9.3 ft heat/cool 4 Room dimensions 5.0 x 5.0 ft 15.0 x 7.0- It 5 Room area 25.0 W 105.0 ft' Ty Construction U-%slue Or HTM Area (ft') Load Area It-) Load number (BtUVft-F) (Btuhlft' or perimeter (ft) (Stuh) a perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 W 13A-4ccs 0.143 It 4.00 2.19 47 47 186 102 65 65 261 142 y/ lak lccs 0.143 a 4.00 Z19 0 0 0 0 140 131 523 286 2 glazing, clr lcwr a 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 III-----GGD 2 glazing, clr lawe 0.650 a 18.20 31.52 0 0 0 0 9 1 164 284 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 219 0 0 0 0 0 .0 0_ 0 U+1 13A4ccs 0.143 w 4.00 Z19 0 0 0 0 _ 0 0 _ 0 0 —G 2 glazing, clr lavc 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 alazirw, clr %awe 0.650 W 11120 25.40 0 0 0 0 0 0 0 0 C 16B30md- 0.032 - 0.90 1.60 25 25 22 40 105. _ 105 _._. 94 _168 F 22A-tph 1.358 - 3802 0.00 25 5 190 0 105 22 837 0 8 c)AED excursion .6 34 Fmelope loss/gain 399 136 1878 845 12 a) In iftration 92 25 405 111 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliences/other 0 0 Subtotal (lines 6 to 13) 491 161 2282 956 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 491 161 2282 956 15 Duct loads 230/6 39%, 111 63 23% 39% 518 375 Total mom load 1 602 1 224 2800 1332 Air required(cfm) 26 10 121 60 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -04 wrrgbbofc- 2019-May-1713:00:51 Right -Suite® Unlversa12018 18.0.31 RSU08101 Page 9 E:\DwumetsXWdghtsoftWAC\SWEENEYRESIDENCE.mp Calc=MJ8 Front Doorfaces: E wrightsofts Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa,c 772466-6796 Email: OUICKCALCS@AOL.COM For: SWEENEY RESIDENCE TREE TOP TRAIL, FORT PIERCE, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1000 cfm Job: Date: May 17, 2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 10.500 in H2O 1.000 in/100ft 1000 cfm 174 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 634 27 13 1.000 4.0 Ox 0 VIFx 5.0 115.0- st3 BEDROOM h 3347 145 102 1.000 7.0 OxO VIFx 14.6 115.0 st1 BEDROOM3 h 3465 150 101 1,000 7.0 OXO VIFx 13.7 115.0 st1 DINING c 2198 66 99 1.000 7.0 OXO VIFx 29.6 115.0 st2 FOYER c 1455 51 65 1.000 6.0 Ox0 VIFX 5.9 115.0 st3 KITCHEN c 2582 84 116 1.000 7.0 OxO VIFx 31.7 115.0 st2 LAUNDRY c 1032 37 46 1.000 6.0 Ox0 VIFx 11.5 115.0 sill LIVING C 3383 109 152 1.000 8.0 Ox0 VIFx 15.1 115.0 st1 M BATH h 2800 121 60 1.000 6.0 OxO VIFx 38.4 135.0 st4 M Wlc 1 h 602 26 10 1.000 4.0 Ox 0 VIFx 38.5 135.0 st4 MWIC2 c 54 1 2 1.000 4.0 Ox0 VIFx 39.5 135.0 st4 MASTER BEDROOM c 2115 78 95 1.000 7.0 OXO VIFx 29.6 115.0 st2 MASTER BEDROOM -A c 2115 78 95 1.000 7.0 OxO VIFx 36.6 115.0 st2 MUDROOM c 952 27 43 1.000 6.0 OxO VIFx 3.7 115.0 st3 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 148 72 1.000 755 6.0 0 x 0 VinlFlx st2 st2 Peak AVF 455 477 1.000 723 11.0 0 x 0 VinlFlx st1 Peak AVF 440 402 1.000 807 10.0 0 x 0 VinIFIX st3 Peak AVF 105 121 1.000 347 8.0 0 x 0 VinIFIX wrightsoft- 2019-May-1713:00:52 �r, RighlSuiteO UnNersal 2018 16.0.31 RSUC8101 Page 1 ^`�"^E:\Documnets\Wrightsoft HVAC\SWEENEY RESIDENCE.rup Calc=MJ8 Front Door faces: E Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diann (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1 1000 1000 0 1 0 0 0 Ox 0 VIFx WP19htSOR' 2019-May-17 13:00:52 •w• •• ^���•+�+ RightSuite® Universal 2018 18.0.31 RSU08101 Page 2 ACCAE:\Dacurmets\Wrightsot HVAC\SWEENEYRESIDENCE.rup Calc=MJB Front Doarfeces:E 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SWEENEY RESIDENCE Builder Name: Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, F1, 34951 Permit Number: V Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the lop of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subffoor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior wells, or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler c er Mates and walls or ceilinos. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/17/2019 1:07 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.