HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
SCANNED
BY
St. Lucie County
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SWEENEY RESIDENCE
Builder Name:
Street: TREE TOP TRAIL
Permit Office: ST LUCIE COUNT'
JAN 2 4 P029
City, State, Zip: FORT PIERCE, FL,
34951
Permit Number:
Owner: JOHN SWEENEY
Jurisdiction; ST LUCIE COUNT" ST.
Lucie County, Permitting
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Cl rate Pone
2 �
1. New construction or emsting
New (From Plans)
9. Wall Types (1568.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 1568.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (1440.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1440.00 ft2
6. Conditioned floor area above grade (ft2)
1440
b. NIA
R= ft2
Conditioned Floor area below grade (ft2)
0
c. N/A
R= ft2
11. Duds
R ft'
7. Windows(137.5 sqft.) Description
Area
a. Sup: Attic, Rel: Attic, AH: MUOROOM
6 140
a. U-Factor: Sgl, U=0.85
84.13 ft2
SHGC: SHGC=0.40
b. U-Factor: Sgl, U=0.69
53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
30.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft'
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.330
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1440.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 1440.00 %'
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.095
Total Proposed Modified Loads: 52.11
PASS
Total Baseline
Loads: 54.55
I hereby certify that the plans and specifications covered by
Review of the plans and
O
this calculation are in compliance with
Code.
the Florida Energy
specifications covered by this
e+ -
calculation indicates compliance
�.Q[/�yi��L
with the Florida Energy Code.
PREPARE 2
,� 1K3C �
Beforeconstruction
�`�""�
DATE: 1 4
be inspected fO
compliance with Section 553.908
I hereby certify that this i , aIdgned,
is in compliance
Florida Statutes.
with the Florida Energy.
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
F11A 60py
1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
TiOe:
SWEENEY RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
1440
Lot #
Owner Name:
JOHN SWEENEY
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
TREE TOP TRAIL
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL, 34951
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
LOW
BLOCKS
Number
Name
Area
Volume
1
Entire House
1440
13392
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
In9I ID
Finished Cooled
Healed
1
BEDROOM 3
151
1404.3
No
0
1
1
Yes
Yes
Yes
2
CLST 3
14
130.2
No
0
1
Yes
Yes
Yes
3
LAUNDRY
42
390.6
No
0
1
Yes
Yes
Yes
4
LINEN
a
74.4
No
0
1
No
Yes
Yes
5
CLST2
18
167.4
No
0
1
Yes
Yes
Yes
6
BEDROOM 2
151
1404.3
No
0
1
1
Yes
Yes
Yes
7
BATH 2
45
418.5
No
0
1
Yes
Yes
Yes
8
MUDROOM
45
419
No
0
1
Yes
Yes
Yes
9
HALLWAY
48
446.4
No
0
1
No
Yes
Yes
10
LIVING
177
1646.1
No
0
1
Yes
Yes
Yes
11
DINING
144
1339.2
No
0
1
Yes
Yes
Yes
12
KITCHEN
165
1534.5
Yes
0
1
Yes
Yes
Yes
13
FOYER
72
669.6
No
0
1
Yes
Yes
Yes
14
MASTER BEDROO
206
1906.5
No
0
1
1
Yes
Yes
Yes
15
M WIC 2
25
232.5
No
0
1
No
Yes
Yes
16
M WIC 1
25
233
No
0
1
Yes
Yes
Yes
17
M BATH
105
977
No
0
1
Yes
Yes
Yes
V23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 3
24 It
0
151 ft2
1
0
0
2 Slab -On -Grade Edge Insulation
CLST 3
2 ft
0
14 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
LAUNDRY
Eft
0
42 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
LINEN
t ft
0
8 ft2
___
1
0
0
5 Slab -On -Grade Edge Insulation
CLST 2
2ft
0
18 ft2
1
0
0
6 Slab -On -Grade Edge Insulation
BEDROOM 2
24 It
0
151 ft2
__
1
0
0
7Slab-On-Grade Edge Insulation
BATH 2
511
0
45 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulation
MUDROOM
5 ft
0
45 ft2
__
1
0
0
9 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
0
48 ft2
I
__
1
0
0
1081ab-On-Grade Edge Insulation
LIVING
12 ft
0
177 ft2
___
1
0
0
11SIab-On-Grade Edge Insulation
DINING
12 ft
0
144 ft2
__
1
0
0
12SIab-On-Grade Edge Insulation
KITCHEN
14it
0
165 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
FOYER
8 ft
0
72 ft2
__
1
0
0
14SIab-On-Grade Edge Insulation
MASTER BEDRO 27 ft
0
205 ft2
1
0
0
15SIab-On-Grade Edge Insulation
M WIC 2
1 ft
0
25 ft2
___
1
0
0
16SIab-On-Grade Edge Insulation
M WIC 1
5ft
0
25 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
M BATH
22 It
0
105 ft2
___
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar SA Emift
Emifl
Deck
Pitch
V
# Type Materials
Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 1560 ft2
0 ft2
Light
N
0.3 No 0.9
No
0
22.6
ATTIC
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
1440 ft2
N N
1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
_
1
Under Attic (Vented) BEDROOM 3
30
Blown
151 W
0.1
Wood
2
Under Attic (Vented) CLST 3
30
Blown
14 ft2
0.1
Wood
_
3
Under Attic (Vented) LAUNDRY
30
Blown
42 ft-
0.1
Wood
_
4
Under Attic (Vented) LINEN
30
Blown
8ft2
0.1
Wood
5
Under Attic (Vented) CLST2
30
Blown
18 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
151 ft2
0.1
Wood
_
7
Under Attic (Vented) BATH 2
30
Blown
45 ft2
0.1
Wood
_
8
Under Attic (Vented) MUDROOM
30
Blown
45 ft2
0.1
Wood
_
9
Under Attic (Vented) HALLWAY
30
Blown
48 ft2
0.1
Wood
_
10
Under Attic (Vented) LIVING
30
Blown
177 ft2
0.1
Wood
_
11
Under Attic (Vented) DINING
30
Blown
144 ft2
0.1
Wood
_
12
Under Attic (Vented) KITCHEN
30
Blown
165 ft2
0.1
Wood
_
13
Under Attic (Vented) FOYER
30
Blown
72 ft2
0.1
Wood
_
14
Under Attic (Vented) MASTER BEDRO
30
Blown
205 ft2
0.1
Wood
15
Under Attic (Vented) M W IC 2
30
Blown
25 ft2
0.1
Wood
_
16
Under Attic (Vented) MWIC1
30
Blown
25W
0.1
Wood
17
Under Attic (Vented) MBATH
30
Blown
105 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 1
S
Extedor Concrete Block - Int InsuBEDROOM 3
4
11
0 9
4
102.7 112
0
0
0.3
0
_ 2
W
Exterior Concrete Block - Int InsuBEDROOM 3
4
13
0 9
4
121.3 ft2
0
0
0.3
0
_ 3
W
Exterior Concrete Block - Int Insul CLST 3
4
2
0 9
4
18.7 ft2
0
0
0.3
0
_ 4
W
Exterior Concrete Block - Int Insul LAUNDRY
4
6
0 9
4
56.0 ft2
0
0
0.3
0
_ 5
S
Exterior Concrete Block- Int Insul CLST 2
4
2
0 9
4
18.7 ft2
0
0
0.3
0
_ 6
E
Exterior Concrete Block - Int InsuBEDROOM 2
4
13
0 9
4
121.3 ft2
0
0
0.3
0
_ 7
S
Exterior Concrete Block- Int InsuBEDROOM 2
4
11
0 9
4
102.7 ft2
0
0
0.3
0
_ 8
E
Exterior Concrete Block - Int Insul BATH 2
4
5
0 9
4
46.7 f12
0
0
0.3
0
9
E
Exterior Concrete Block- Int InsuIMUDROOM
4
5
0 9
4
46.7 fN
0
0
0.3
0
_ 10
W
Exterior Concrete Block- Int Insul LIVING
4
12
0 9
4
112.0 ft2
0
0
0.3
0
_ 11
W
Exterior Concrete Block- Int Insul DINING
4
12
0 9
4
112.0 ft2
0
0
0.3
0
_ 12
E
Exterior Concrete Block- Int Insul KITCHEN
4
14
0 9
4
130.7 ft2
0
0
0.3
0
_ 13
E
Exterior Concrete Block- Int Insul FOYER
4
8
0 9
4
74.7 fN
0
0
0.3
0
_ 14
N
Exterior Concrete Block- Int InsuMASTER BE
4
12
0 9
4
112.0 ft2
0
0
0.3
0
_ 15
W
Exterior Concrete Block - Int InsuMASTER BE
4
15
0 9
4
140.0 ft2
0
0
0.3
0
_ 16
N
Exterior Concrete Block - Int Insul M WIC 1
4
5
0 9
4
46.7 ft2
0
0
0.3
0
_ 17
N
Exterior Concrete Block- Int Insul M BATH
4
7
0 9
4
65.3 ft2
0
0
0.3
0
18
E
Exterior Concrete Block - Int Insul M BATH
4
15
0 9
4
140.0 ft2
0
0
0.3
0
1/23/2020 6:40 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
• FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt Door Type
Space Storms U-Value Width
Ft In
Height
Ft In
Area
1
E Insulated
FOYER None .27 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Omt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
_ 1
_ 2
3
_ 4
5
6
W 2 Vinyl Low-E Single
E 6 Vinyl Low-E Single
W 10 Metal Low-E Single
E 12 Vinyl Low-E Single
W 15 Vinyl Low-E Single
E 18 Vinyl Low-E Single
Yes 0.85 0.4 Y 22.0 ft' 2 ft 0 in 0 it 14 in
Yes 0.85 0.4 Y 22.0 ft' 2 ft 0 in 0 ft 14 in
Yes 0.69 0.22 Y 53.3 ft2 2 ft 0 in 0 ft 23.51
Yes 0.85 0.4 Y 9.0 ft' 2 ft 0 in 0 ft 14 in
Yes 0.85 0.4 Y 22.0 ft2 2 ft 0 in 0 ft 14 in
Yes 0.85 0.4 Y 9.0 ft2 2 It 0 in 0 It 14 in
None
None
Drapes/blinds
None
None
None
None
None
Exterior 5
None
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000414 1562.6 85.78 161.33 .1523
7
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central UnlV
Split Single SEER: 16 30 kBtu/hr 900 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt
Conservation
1
Electric None
MUDROOM 0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/
V #
— Supply--
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC #
Heat Cool
1
Attic 6 140 ft2
Attic 14 ft' Default Leakage MUDROOM (Default) c(Default) c
1 1
1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
• FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programablef
N
Ceiling Fans:
xThermostat:X�
Heal ng Jan
Feb
Mar
Apr�X
Jun
[ � Jul
r I
[X] Aug
fX
[
Sep
[ ]
L 1 Oct
fr Dec
Venting [ ]Jan I
l l l
l Feb
X Mar
Apr
[
May,
l 1 Jun
I Jul
[ 1 Aug
I
Sep
Ixl
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating(WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(B lbs/sq.ft.
0 ft2
0 ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
SUN ROOM
Default(81bs/sq.ft
ft2
ft
0.3
GREAT ROOM
Default(8 lbs/sq.R.
fP
ft
0.3
LINEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 lbs/sq.ft.
112
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ft2
It
0.3
BATH 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
OFFICE CLST
Default(8 lbs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 lbs/sq.ft,
ft2
ft
0.3
WIC
Default(B lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOMS LIVIN
Default(81bs/sq.fL
ft2
ft
0.3
M WIC
Default(8 lbs/sq.R.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.fL
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(B lbs/sq.ft.
ft,
ft
0.3
WIC3
Default(8 lbs/s.ft.
ft2
It
0.3
BEDROOM 3
1/23/2020 6:40 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD fix - -
i
I
JAN 2 4 2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ST. Lucie County, Permitting i
ESTIMATED ENERGY PERFORMANCE INDE - " -
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12, Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location MUDROOM
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned Floor area (sq. ft.) 6. 1440 d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.788
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.330
c) Area 7c. 137.5
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
0 Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131.
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat No
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be inst led (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be complet b d on installed code compliant features. fit'
Builder Signature: Date:,
Address of New Home: TREETOPTRAIL City/FL Zip: FORT PIERCE, FL 34951
1123/2020 6:40:44 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERI RECEIVED
TABLE 402.4.1.1 JAN 2 4 2020
AIR BARRIER AND INSULATION INSPECTION COMPONEN CRITERIA
Project Name: SWEENEY RESIDENCE Builder Name:
Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number:
Y
Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the lop plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing g cavity insulation shall
and cantilevered floors
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Dud shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or Insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to rill voids between fire sprinkler
cover olates and walls or ceilings.
a. in aaamon, inspection or log watts shall be in accordance with the provisions of ICC-400.
1/23/2020 6:40 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
SCANNED
® Project SummaryBY Job:
-I Wrightsoft te: May17,2019
Entire House St. Lucie Countv By
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Favc T72466-6796 Email: QUICKCALCS AOL.COM
For. SWEENEY RESIDENCE
TREE TOP TRAIL, FORT PIERCE, FL 34951
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Outside db
Inside db
Design TO
Summer Design Conditions
42 OF Outside db
70 OF Inside db
28 OF Design TO
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure 18862 Btuh
Ducts 4277 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 23139 Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
He
Co
Area (ft)z
12
1
Volume (fta)
13392
13392
Airchangesfhour
0.45
0.23
Equiv. AVF (cfm)
100
51
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
6.4 kW
21711 Btuh
20 OF
1000 cfm
0.043 cfm/Btuh
1.00 in H2O
90 OF
75 OF
15 M OF
50 %
61 gdlb
Sensible Cooling Equipment Load Sizing
Structure
15987
Btuh
Ducts
6273
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data In
Rate/swing multiplier 0.95
Equipment sensible load 21147 Btuh
Latent Cooling Equipment Load Sizing
Structure
4145
Btuh
Ducts
1671
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
5815
Btuh
Equipment Total Load (Sen+Lat)
26962
Btuh
Req. total capacity at 0.70 SHR
2.5
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM
Cond RA1630AJ1NA
Coil RH1T3621MTANJA
AHRI ref 7941344
Efficiency 13.0 EER, 16 SEER
Sensible cooling
21000
Btuh
Latent cooling
9000
Btuh
Total cooling
30000
Btuh
Actual air flow
1000
cfm
Air flow factor
0.045
cfm/Btuh
Static pressure
1.00
in H2O
Load sensible heat ratio
0.79
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-r p- wrljLI ft- 1� {^1 �'�N-� 2019-May-17 13:00:51
•^ Right -Suite® Universal 2018 18.0.31 RSU08101 FWD- D- s V' Page 1
ACCKEADocunnetsMaghtsoft HVAC\SWEENEY RESIDENCE.rup Cale =MJ8 Front Door faces: E FILE COPY
I F wrightsotV Right-)@ Worksheet Job:
Entire House Date: May 17, za19
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
BEDROOM 3
2
Exposed wall
168.0 ft
24.0 It
3
Room height
9.3 ft
9.3 ft heaUcool
4
5
Room dimensions
Room area
1440.0 ft'
1.0 x 151.0 ft
151.0 ft'
Ty
Construction
1-1-value
Or
HTM
Area (ft')
Load
Area (ft�
Load
number
(BtutVftk'F)
(Btuwftg
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cad
Gas
N/P/S
Heat
Cool
Gross
WP/S
Heat-
Cool
6
.
W
1�
13A4ccs
13AAccs
0.143
0.143
n
a
4.00
4.00
219
219
223
558
223
504
894
2018
488
1102
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
a
18.20
33.77
25
0
455
844
0
0
0
0
2 glazing, clr low-e
0.650
a
18.20
31.52
9
1
164
284
0
0
0
0
11
11130
0.390
a
10.92
10.34
20
20
219
208
0
0
0
0
W
v+/
134-4acs
13A4ccs
0.143
0.143
s
w
4.00
4.00
219
219
223
558
223
472
894
1891
488
1034
102
121
102
105
.,. 410
420
_ — _224
230
2 glazing, clr low-e
0.650
w
18.20
33.77
32
0
582
1081
16
0
291
540
��(C'
2 alazino. clr low-e
0.650
w
18.20
25.40
54
0
976
1362
0
0
0
0
C
161380md
0.032
-
0.90
1.60
1440
1440
1290
2304
151.
151
_
_ 135
. .w 242
F
22A-toh
1.358
-
38.02
0.00
1440
168
6388
0
151
24
913
0
6
c)AED excursion
5%
173
Ernelope loss/gain
15771
9791
2169
1409
12
a) Infiltration
3091
846
442
121
b) Roomventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
5350
0
Subtotal (lines 6 to 13)
18862
15987
2510
1530
Less e#ernal load
0
0
-0
0
Less transfer
0
0
0
0
Redistribution
0
0
214
91
14
Subtotal
18962
15987
2824
1621
15
Duct loads 1
231/6
39%
4277
6273
23%
39%
640
636
Total. load
23139
22260
3465
2257
Air required (cfm)
1000
1000
150
101
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
M}F wrrghesofe- 2019-May-1713:00:51
AMA Right -Suite) Universal 2018 18.0.31 RSU08101 Page 1
E:\Dmumets\WrightsoftHVAC\SWEENEYRESIDENCE.mp Calc=MJ8 Front Doorfaces: E
wrightsofr RighWO Worksheet Job:
Entire House Date: May 17, zols
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Far. 77246645796 Email: OUICKCALCS@AOL.COM
1
Room name
CLST3
LAUNDRY
2
Exposed wall
2.0 ft
6.0 it
3
Room height
9.3 ft heat/cool
9.3 It heat/cool
4
Room dimensions
2.0 x 7.0 ft
6.0 x 7.0 ft
5
Room area
14.0 ft-
42.0 fR
Ty
Coretmction
U-value
Or
HTM
rea Aqt�
Load
Area (ft2)
Load
number
(BtuMWl')
(Btu)Vft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat I
Cool
Gross
N/P!S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A4ocs
0.143
In
4.00
Z19
0
0
0
0
0
0_
0-
'0
0
13A-4ocs
0.143
a
4.00
2-19
0
0
0
0
0
0
0
2 glazing, clr lcw-e
0.650
a
18.20
33.77
0
0
0
0
0
0
0
0
1i
2 glazing, clr lowe
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
11D0
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
w
1344ocs
0.143
s
4..00
219
0
0
-0
- 0
-- 0'
-- 0
-.' ',0
_. :-.A
13A4ocs
0.143
w
4.00
219
19
19
74
41
56
56
223
122
2 glazing, clr lowe
0.650
w
18.20
33.77
0
0
0
0
0
0
0
0
2 olmm. clr lowe
0.650
w
18.20
25.40
0
0
0
0
0
0_
0
0
C _
1fiB30md
0.032
0.90
1.60
14
14
13
22
42
- - _-_42
_ _ 38
....- _67.
F
22A-toh
1.358
-
38.02
0.00
14
2
76
0
42
- 6
228
- 0
61
c)AEO emursion
-3
-25
Envalope loss/gain
163
61
1 489
164
12
a) hfilbation
37
10
110
30
b) Roomvantilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
500
Subtotal(lims 6to 13)
200
71
600
695
Less extemal load
0
0
-0
0
Less transfer
0
0
0
0
Redistribution
-200
-71
96
46
14
Subtotal
0
0
696
741
15
Duct bads
23%
39%
0
0
23%
39%
158
291
Total mom load
0
0
854
1032
Air required(cfm)
0
0
37
46
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrrgtieso>Pe- 2019-May-1713:00:51
.4C�A ISWEEuiEY U SIDE I E.w 18.Cao RSU08101 Page 2
E:1Documnets\Wrightsofl HVAC1SWEENEV RESIDENCE.mp CaIc=MJB Front Door faces: E
r�t wrightsoftr Right-M Worksheet Job:
Entire House Date: May 17, 2019
By:
QUICK CALCS, INC.
317 Sr LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM
i
Room name
LWEN
CLST 2
2
Eked wall
0 ft
2.0 It
3
Room height
9.3 ft heat/cool
9.3 It heat/cod
4
Room dimensions
2.0 x 4.0 It
9.0 x 20 It
5
Room area
8.0 ft.
18.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (W)
Load
number
(BtulVft2-F)
(BtuWff2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cad
Gross
N/P(S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A4ocs
0.143
n
4.00
2.19
0
0
0
0
0
0
0
0
13A-4ocs
0.143
a
4.00
219
0
0
0
0
0
0
0
0
2 glazing, clr lows
0.650
a
18.20
33.7
0
0
0
0
0
0
0
0
2 glazing, clr lowe
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
11D0
0.390
e
10.92
10.34
0
0
0
0
0
0
0
0
W
.13A-4ws
0.143
s
_
4.00
2.19
0
0
0
0
19
19
- _ _ 74
____ - 41
Vy
13A4ocs
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
2 glazing, clr Iwe
0.650
w
18.20
33.77
0
0
0
0
0
0
0
0
::G
2 alazina. clr lowe
0.650
w
18.20
25.40
0
0
0
0
0
0
0
0
C
1613-30md
0.032
-
0.90
- 1.60
8
8
7
13
18
-_-18
_ _ .16
�. -._.29
F
22A-toh
1.358
38.02
0.00
8
0
0
0
18
2
-76
0
6
c)AED excursion
0
3
Envelope loss/gain
7
12
167
67
12
a) Infiltration
0
0
37
10
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
7
12
203
77
Less external load
0
0
0
0
Less transfer
0
0
-0
0
Redistribution
-7
-12
-203
-77
14
Subtotal
0
0
0
0
15
Duct loads '
23%
W/o0
0
231
39%
0
0
Total room load
0
0
0
0
Air required (cfm)
0
0
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
2019-May-17 13:00,51
A&K RightSuite@ Universal 2018 18.0.31 RSU08101 Page 3
E:1Docurmets\Wrightsoft HVAC\SWEENEV RESIDENCE.rup Calc=MIA Front Door faces: E
+wrightsoft, Right-MWorksheet Job:
Entire House Date: May 17, 2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6795 Emil: OUICKCALCS@AOL.COM
1
Room name
BEDROOM 2
BATH 2 _
2
Evosed wall
24.0 it
5.0 ft
3
Room height
9.3 it heaticool
9.3 It heat/coot
4
Room dimensions
1.0 x 151.0 ft
5.0 x 9.0 R
5
Room area
151.0 f 2
45.0 ft2
Ty
Coretruction
U-Nelue
Or
HTM
Area (ft)
Load
Area (ft-)
Load
number
(BtuNft2-'F)
(Btu)Vft2)
or perimeter (it)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
w
13A-4ocs
0.143
n
4.00
219
0
0
0
0
0
0
---0-
0
%
13A-4ocs
0.143
a
4.00
219
121
105
420
230
47
47
186
102
2 glazing, clr low-e
0.650
a
18.20
33.77
16
0
291
540
0
0
0
0
IIL--GGD
glazing, cir low-e
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
110
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
w
13A-0acs
0.143
s
4.00
219
102
.102
410
224
0
_ _
0.
_
0
0
Y)/
13A4ocs
0.143
w
4.00
2.19
0
0
0
0
0
_-
0
_
0
0
IL-IGi
2 glazing, cir low-e
0.650
w
18.20
33.77
0
0
0
0
0
0
0
0
2 eladm. clr low-e
0.650
w
18.20
25.40
0
0
0
0
0
0
0
0
C
161330md
0.032
-
0.90
, 1.60
151
151
_ 135.
242
- 45
__ __45
__ __ 40
. ..72
F.
22A-toh
1.358
-
38.02
0.00
151
24
_ 913
0
45
. _ 5
_
190
_
_ 0
6
c)AED excursion
-26
-7
Envelope loss/gain
2169
1209
417
167
12
a) Infiltration
442
121
92
25
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
250
0
Subtotal (fines 6to 13)
2610
1580
509
192
Less ex4emal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
119
54
- 8
14
14
Subtotal 1
2729
1634
517
2D6
15
Duct loads
23%
39%
619
641
23%
39%
117
81
Total room load
3347
2275
634
287
Air required (cfm)
145
102
27
13
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
_ A -PP- w�lghGsofc- 2019-May-1713:00:51
Right -Suite® Universal 2018 18.0.31 RSU08101 Page 4
EADocurrnets\Wdghtsoff HVAC1SWEENEY RESIDENCE.rup Calc=MJ8 Front Door faces:E
I{� wrightsoft, Right-M Worksheet Job:
Entire House Date: May 77, zols
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724666796 Email: QUICKCALCS@AOL.COM
1
Room rlame
MUDROOM
HALLWAY
2
Flposed wall
6.0 it
0 It
3
Room height
9.3 It heat/cool
9.3 ft heat/cod
4
Room dimensions
5.0 x 9.0 It
1.0 x 48.0 It
5
Room area
45.0 ft-
48.0 W
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area (ftj
Load
number
(BWIV °-°F)
(Btuhrft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
He;
Cod
Gross
N/PIS
Heat
Cool
Gress
N/PIS
Heat
Cool
6
W
13A4acs
0.143
n
4.00
2.19
0
0
0
0
0
0
0
- - 0
13A-0acs
0.143
a
4.00
2.19
47
47
186
102
0
0
-0
0
2 glazing, clr lowe
0.650
a
18.20
33.77
0
0
0
0
0
0
0
0
2 glazing, clr Iov-e
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
W
13A-4ocs
0.143
s
4.00
2.1919
0
0
0
0
- 0
_ __-0
_ 0
_ _ 0
_ _
_.. -0
lql
13A-4=
0.143
w
4.00
219
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
w
18.20
33.77
0
0
0
0
0
0
0
0
L�—GC
2 alazina. dr Iowe
0.650
w
18.20
25.40
0
0
0
0
0
0
0
0
C
16B-30mtl-
0.032
-
0.90
1.60
45
45
40
- 72
_
-48-
_
48
___ 43
__ __77
F
22A-toh
1.358
-
38.02
0.00
45
5
190
0
48
0
0
0
6
c)AED mursion
-24
-3
Es lope loss/gain
417
150
43
74
12
a) Infiltration
92
25
-a
0
b) Rcomventilation
0
0
0
0
13
hand gains: Occupants @ 230
0
0
0
0
Appliances/other
500
0
Subtotal(lines 6to 13)
509
675
43
74
Less eMemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
5
9
-03
-74
14
Subtotal
514
683
0
0
15
Duct loads
23%
39346
116
269
23%
39%
0
0
Total room load
630
952
0
0
Air rec ired(din)
27
43
0
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
-pj' wr�gtibo_M 2019-May-1713:00:51
A Right -Suite® Universal 2018 18.0.31 RSU08101 Page 5
E:\Docurmets\Wnghtsofl HVAC\SWEENEY RESIDENCE.rup Calc=MJB Front Door faces: E
wrightsofC Right-M Worksheet Job:
Entire House Date: May 17, 2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM
1
Room name
LIVING
DINING
2
E1ylosed wall
12.0 ft
120 ft
3
Room height
9.3 It heat/cool
9.3 ft heat/cod
4
Room dimensials
1.0 x 1T7.0 ft
12.0 x 120 ft
5
Room area
177.0 ft'
144.0 W
Ty
Construction
U-value
Or
HTM
Area (ft.)
Load
Area (W)
Load
number
(BtuWfti°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W
13A-0ocs
'0.143
n
4.00
219
0
0
0
0
0
0
0
0
13A-0ocs
0.143
a
4.00
2.19
0
0
0
0
0
0
_
-0
_.
0
2 glazing, clr lowe
0.650
a
18.20
33.77
0
0
0
0
0
0
0
0
2 glazing, clr lowe
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
W
13AAccs
0.143
a
4.00
219
0
0.
0
0
0.
0
0--
0
V+/
134-0acs
0.143
w
4.00
219
112
58
232
127
112
112
447
244
��-CC
2 glazing, clr low-e
0.650
W
18.20
33.77
0
0
0
0
0
0
0
0
2 olazino. clr low-e
0.650
w
18.20
25.40
54
0
976
1362
0
0
0
0
C
166<10md
0.032
-
0.90
1.60
177
. 177
159
283
_
144
_ . _144
_ _
_ 129
- 230
F
22A-toh
1.358
-
38.02
0.00
177
12
456
0
144
12
456
-
0
6
c)AED elxursion
578
-56
Envelope loss/gain
1823
2349
1032
418
12
a) Infiltration
221
60
221
60
b) Roomvemilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
1100
Subtotal(lines 6to 13)
2043
2410
1253
1579
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
11
20
0
0
14
Subtotal
2055
2430
1253
1579
15
Duct loads
23%
39%
466
953
230/6
39%
284
619
Total room load
2521
3383
1537
2198
Air required (cfm)
tog
752
66
99
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
2019-M_ ay-1713:00:51
RIghlSuite® Universal 2018 18.0.31 RSUD8101 AEADocunnets\Wrighlsoft WACISWEENEY RESIDENCE.mPage 6p Calc=MJ8 Front Door loons: E -
i wrightsoft• Right-M Worksheet Job:
Entire House Date: May 17, 2019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: T724GM799 Fax 772466-6796 Emil: OUICKCALCS@AOL.COM
1
Roan name
KITCHEN
FOYER
2
F)Wosed wall
14.0 ft
8A ft
3
Room height
9.3 ft heat/cool
9.3 0 heaticoal
4
5
Room dimensions
Room area
1.0 x 165.0 ft
165.0 R'
8.0 x 9.0 ft
720 ft'
Ty
Construction
U-velue
Or
HTM
Area M
Load
Area (ft-)
Load
number
(BIUVIt °F)
(BtulJf 2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
y/
13A flocs
13AAocz
2 glazing, Gb r we
0.143
0.143
0.650
n
a
a
4.00
4.00
1820
219
219
33.77
0
130
9
0
121
0
0
485
164
0
265
304
0
74
0
_ -0
54
0
_ 0_
217
-0
_-0
119
0
III----,--GGD
11
glazing,110 clr low-e
0.650
0.390
a
a
18.20
10.92
31.52
10.34
0
0
0
0
0
0
0
0
0
20
0
20
0
21.9
0
W
Yil
It--GG
13A4acs
13A4ocs
2 glazing, clr loa2
0.143
0.143
0.650
s
w
w
4.00
4.00
11120
219
219
33.77
0
0
0
0
0
0
0
0
0
0
0
0
_
0
0
0
_ 0
0
0
_
_ 0___
0
0
_20B
_- 0
0
0
C
2 alazina. clr lave
161330md
0.650
0.032
w
18.20
0.90
25.40
1.60
0
165
0
165
0
_ 148
0
264
0
_ _ 72
0
_--.72.
0
-_ 65
0
_-. __ 115
F
22A-toh
1.358
-
38.02
0.00
165
14
532
0
72
8
304
0
6
c)AED excursion
1-49
-37
Envelope loss/gain
1329
784
806
404
12
a) Infiltration
258
71
147
40
b) Room ventilation
0
0
- 0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
1000
600
Subtotal (Iirxs 6 to 13)
1587
1WA
953
1045
Less e#emal load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
0
1587
0
0
1354
0
0
953
0
0
1045
15
Duct loads
23%
39%
360
728
23%
39%
216
410
Total room load
regL imd (cfm)
1984
21116
1151
14�
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
wrl9ti�oP!- 2019-May-1713:00:51
Right -Suite® Universal 2018 18.0.31 RSU08101 Page 7
E:1DacumnetslWdghtsofl HVAC\SWEENEYRESIDENCE.mp Calc=MJB Front Doorfaces: E
wrightsofr Right-M Worksheet Job:
Entire House Date: May 17, zote
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
MASTER BEDROOM
M W IC 2
2
Exposed wall
27.0 it
0 It
3
Room height
9.3 It heaticool
9.3 It heat/coot
4
Room dimensions
1.0 x 205.0 ft
5.0 x 5.0 ft
5
Room area
205.0 ft2
25.0 ft2
Ty
Construction
U-value
Or
HTM
Area qft
Load
Area (ft-)
Load
number
(Bluh/ftMF)
(Btuh/ftl
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W�l
13A-4=
0.143
n
4.00
219
112
112
447
244
0
0
0
0
1
13AAocs
0.143
a
4.00
219
0
0
0
0
0
0
0
0
2 glazing, clr lowe
0.650
a
18.20
33.77
0
0
0
0
0
0
-0
0
h
2 glazing, dr low-e
0.650
a
18.20
31.52
0
0
0
0
0
0
0
0
11
11D0
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
W
13AAccs
0.143
s
4.00
219
0
0
0
0
0
0
_
0._
0
y/L
13A-0ars
0.143
w
4.00
219
140
124
494
270
0
0
0
0
�(C'
2 glazing, clr lcw-e
0.6W
w
18.20
33.77
16
0
291
540
0
0
0
0
2 clazino, clr low_-e
0.650
w
18.20
25.40
0
0
0
0
0
0
0
0
C
16&30md
0.032
-
0.90
1.60
205
205
184
328
25
. _ .- _25
._ . _-. .22
_ _ 40
F
22A-toh
1.358
-
38.02
0.00
205
27
1027
0
25
0
0
0
6
c)AED excursion
120
-1
Envelope loss/gain
2443
1502
22
39
12
a) Infiltration
497
136
0
0
b) Roomventilation
0
0
-0
0
13
Internal gains: Occupants Q 230
0
0
0
0
Appliances/other
1400
0
Subtotal (lines 6 to 13)
2940
3038
22
39
Less wdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
2940
3038
22
39
15
Duct loads
235/6
39 %
667
1192
23%
39%
- 5
15
Total room load
1
3606
4230
27
54
Air required (cfm)
156
190
1
2
Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed.
_ -PI- wrrg!>1boFe- 2019-May-17 13:00:51
ACCA RlghtSuite® Universal 201818.0.31 RSU08101 Page 8
EADocuneets\Wrightsoft HVACISWEENEY RESIDENCE.rup Cale = MJ8 Front Door faces: E -
wrightsogr Right-M Worksheet Job:
Entire House Date: May 17, 2019
QUICK CALCS, INC. By-
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fan 772AGG-6796 ErnaiC OUICKCALCS AOL.COM
1
Room name
M W IC 1
M BATH
2
F)posed wall
5.0 It
22.0 ft
3
Room height
9.3 It heaticool
9.3 ft heat/cool
4
Room dimensions
5.0 x 5.0 ft
15.0 x 7.0- It
5
Room area
25.0 W
105.0 ft'
Ty
Construction
U-%slue
Or
HTM
Area (ft')
Load
Area It-)
Load
number
(BtUVft-F)
(Btuhlft'
or perimeter (ft)
(Stuh)
a perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W
13A-4ccs
0.143
It
4.00
2.19
47
47
186
102
65
65
261
142
y/
lak lccs
0.143
a
4.00
Z19
0
0
0
0
140
131
523
286
2 glazing, clr lcwr a
0.650
a
18.20
33.77
0
0
0
0
0
0
0
0
III-----GGD
2 glazing, clr lawe
0.650
a
18.20
31.52
0
0
0
0
9
1
164
284
11
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
W
13A4ocs
0.143
s
4.00
219
0
0
0
0
0
.0
0_
0
U+1
13A4ccs
0.143
w
4.00
Z19
0
0
0
0
_
0
0
_
0
0
—G
2 glazing, clr lavc
0.650
w
18.20
33.77
0
0
0
0
0
0
0
0
2 alazirw, clr %awe
0.650
W
11120
25.40
0
0
0
0
0
0
0
0
C
16B30md-
0.032
-
0.90
1.60
25
25
22
40
105.
_ 105
_._. 94
_168
F
22A-tph
1.358
-
3802
0.00
25
5
190
0
105
22
837
0
8
c)AED excursion
.6
34
Fmelope loss/gain
399
136
1878
845
12
a) In iftration
92
25
405
111
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants Q 230
0
0
0
0
Appliences/other
0
0
Subtotal (lines 6 to 13)
491
161
2282
956
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
491
161
2282
956
15
Duct loads
230/6
39%,
111
63
23%
39%
518
375
Total mom load
1
602
1
224
2800
1332
Air required(cfm)
26
10
121
60
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
-04 wrrgbbofc- 2019-May-1713:00:51
Right -Suite® Unlversa12018 18.0.31 RSU08101 Page 9
E:\DwumetsXWdghtsoftWAC\SWEENEYRESIDENCE.mp Calc=MJ8 Front Doorfaces: E
wrightsofts Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa,c 772466-6796 Email: OUICKCALCS@AOL.COM
For: SWEENEY RESIDENCE
TREE TOP TRAIL, FORT PIERCE, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/100ft
1000
cfm
Job:
Date: May 17, 2019
By:
Cooling
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 10.500
in H2O
1.000
in/100ft
1000
cfm
174 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matt
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH 2
h 634
27
13
1.000
4.0
Ox 0
VIFx
5.0
115.0-
st3
BEDROOM
h 3347
145
102
1.000
7.0
OxO
VIFx
14.6
115.0
st1
BEDROOM3
h 3465
150
101
1,000
7.0
OXO
VIFx
13.7
115.0
st1
DINING
c 2198
66
99
1.000
7.0
OXO
VIFx
29.6
115.0
st2
FOYER
c 1455
51
65
1.000
6.0
Ox0
VIFX
5.9
115.0
st3
KITCHEN
c 2582
84
116
1.000
7.0
OxO
VIFx
31.7
115.0
st2
LAUNDRY
c 1032
37
46
1.000
6.0
Ox0
VIFx
11.5
115.0
sill
LIVING
C 3383
109
152
1.000
8.0
Ox0
VIFx
15.1
115.0
st1
M BATH
h 2800
121
60
1.000
6.0
OxO
VIFx
38.4
135.0
st4
M Wlc 1
h 602
26
10
1.000
4.0
Ox 0
VIFx
38.5
135.0
st4
MWIC2
c 54
1
2
1.000
4.0
Ox0
VIFx
39.5
135.0
st4
MASTER BEDROOM
c 2115
78
95
1.000
7.0
OXO
VIFx
29.6
115.0
st2
MASTER BEDROOM -A
c 2115
78
95
1.000
7.0
OxO
VIFx
36.6
115.0
st2
MUDROOM
c 952
27
43
1.000
6.0
OxO
VIFx
3.7
115.0
st3
Supply Trunk Detail Table
Trunk
Htg
Cig
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st4
Peak AVF
148
72
1.000
755
6.0
0 x 0
VinlFlx
st2
st2
Peak AVF
455
477
1.000
723
11.0
0 x 0
VinlFlx
st1
Peak AVF
440
402
1.000
807
10.0
0 x 0
VinIFIX
st3
Peak AVF
105
121
1.000
347
8.0
0 x 0
VinIFIX
wrightsoft- 2019-May-1713:00:52
�r, RighlSuiteO UnNersal 2018 16.0.31 RSUC8101 Page 1
^`�"^E:\Documnets\Wrightsoft HVAC\SWEENEY RESIDENCE.rup Calc=MJ8 Front Door faces: E
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diann
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1 1000
1000
0
1 0
0
0
Ox 0
VIFx
WP19htSOR' 2019-May-17 13:00:52
•w• •• ^���•+�+ RightSuite® Universal 2018 18.0.31 RSU08101 Page 2
ACCAE:\Dacurmets\Wrightsot HVAC\SWEENEYRESIDENCE.rup Calc=MJB Front Doarfeces:E
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SWEENEY RESIDENCE Builder Name:
Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, F1, 34951 Permit Number:
V
Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the lop of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subffoor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior wells, or insulation that on
installation readily conforms to available space shall
extend behind piping and Wring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
c er Mates and walls or ceilinos.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/17/2019 1:07 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.