Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 `gg-CS"3 a FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION "Florida Department of Business and Professional Regulation - Residential Performance Method SCANNED Project Name: TILLBERG RESIDENCE Builder Name: GEM BUILDERS Street: 1313 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY BY - City, State, Zip: FORT PIERCE, FL, Permit Number: St. Lucie County Owner: WILLIAM AND DANA TILLBERG Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing _ New (From Plans) 9. Wall Types (2944.8 sqft.) Insulation Area 2. Single family or multiple family, Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 2654.80 it' b. Frame -Wood, Adjacent R=11.0 290.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. NIA R= ft' to. Ceiling Types (2778.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2778.00 ftz 6. Conditioned Floor area above grade (ft') 2778 b. NIA R= ft' Conditioned Floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(452.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 200 a. U-Factor: Sgl, U=0.55 452.67 ft' SHGC: SHGC=0.22 b. U-Factor: N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: NIA ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 6.153 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems a. Electric Cap: 50 gallons S. Floor Types (2778.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2776.00 ft b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.163 Total Proposed Modified Loads: 93.74 PASS Total Baseline Loads: 95.34 1 hereby certify that the plans and specifications covered by Review of the plans and S7gyF this calculation are in compliance with the Florida Energy specifications covered by this OfgtiE Code. calculation indicates compliance {� with the Florida Energy Code. PREPAR Y: Before construction is completed DATE: -5- 9 this building will be inspected for compliance with Section 553.908 I hereby certify that this bu di designed, is in compliance Florida Statutes. rid a Energy C de COD WE SRO OWNER/A BUILDING OFFICIAL: DATE: - Compliance requires certifilat4 by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 1i project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT 5UMMARY GHEGKLI5T REPURF PROJECT Title'. TILLBERG RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2778 Lot # Owner Name: WILLIAM AND DANA TILLBE Total Stories: 1 Block/Subdivislon: # of Units: 1 Worst Case: No PlatBook: Builder Name: GEM BUILDERS Rotate Angle: 0 Street: 1313 LONE PINE DRIV Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) - Comment: CLIMATE / - Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2778 28500 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 4 156 1560 - No 0 1 1 Yes Yes Yes 2 CLST4 18 180 No 0 1 Yes Yes Yes 3 BATH 3 54 540 No 0 1 Yes Yes Yes 4 BEDROOM 3 132 1320 No 0 1 1 Yes Yes Yes 5 CLST 3 16 160 No 0 - 1 Yes Yes Yes 6 BATH 2 64 640 No 0 1 Yes Yes Yes 7 BEDROOM 2 140 1400 No 0 1 1 Yes Yes Yes 8 CLST 2 16 160 No 0 1 Yes Yes Yes. 9 MUD ROOM 105 1050 No 0 1 No Yes Yes 10 AHU CLST 12 120 No 0 1 No Yes Yes 11 DINING 156 1560 No 0 1 Yes Yes Yes 12 FOYER 94 940 No 0 1 Yes Yes Yes 13 KITCHEN 358 3580 Yes 0 1 Yes Yes Yes 14 LIVING ROOM 202 2222 No 0 1 Yes Yes Yes 15 FAMILY ROOM 247 2717 No 0 1 Yes Yes Yes 16 HALL 32 320 No 0 1 No Yes Yes 17 HALL 40 400 No 0 1 No Yes Yes 18 MASTER BEDROO 271 2981 r No 0 1 1 Yes Yes Yes 19 M WIC 1 49 490 No 0 1 Yes Yes Yes 20 M WIC 2 54 540 No 0 1 No Yes Yes 21 M BATH 234 2340 No 0 1 Yes Yes Yes 22 M TOILET 20 200 No 0 1 Yes Yes Yes 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 23 W/D 24 240 No 0 1 No Yes Yes 24 POWDER RM 36 360 No 0 1 Yes Yes Yes 25 GAME ROOM 248 2480 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 4 25 ft 0 156 ft2 ___- 1 0 0 2 Slab -On -Grade Edge Insulation CLST 4 2ft 0 18 112 __-_ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 3 6 ft 0 54 ft2 _--_ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 3 lift 0 132 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation CLST 3 2ft 0 16 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation BATH 2 8ft 0 64 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 lift 0 140 ft' _--- 1 0 0 8 Slab -On -Grade Edge Insulation CLST 2 2ft 0 16 ft' --__ 1 0 0 9 Slab -On -Grade Edge Insulation MUD ROOM 1 ft 0 105 ft2 ---_ 1 0 0 10Slab-On-Grade Edge Insulation AHU CLST lit 0 12 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation DINING 14ft 0 156 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation FOYER 9 ft 0 94 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN 14 ft 0 358 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation LIVING ROOM 11 ft 0 202 112 1 0 0 15SIab-On-Grade Edge Insulation FAMILY ROOM 14 ft 0 247 112 ____ - 1 0 0 16SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation HALL 2 1 ft 0 - 40 ft2 1 0 0 18SIab-On-Grade Edge Insulation MASTER BEDRO 27.2 ft 0 . 271 ft2 ____ 1 0 0 19Slab-On-Grade Edge Insulation M WIC 1 8ft 0 49 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation M WIC 2 1 ft 0 54 ft2 ____ 1 0 0 21SIab-On-Grade Edge Insulation M BATH 37 It 0 234 ft2 ____ 1 0 0 22SIab-On-Grade Edge Insulation M TOILET 9ft 0 20 112 ____ 1 0 0 23SIab-On-Grade Edge Insulation W/D lit 0 24 ft2 ---- 1 0 0 24SIab-On-Grade Edge Insulation POWDER RM 18 ft 0 36 112 --__ 1 0 D 25SIab-On-Grade Edge Insulation GAME ROOM 32 ft 0 248 ft2 ____ 1 0 0 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY GHEGKLI5T REPURT ROOF _ / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Ban Absor. Tested Tested Insul. (deg) 1 Hip Metal 3107 ft' 0 ft' Light N 0.4 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2778 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 4 0 Blown 156 ft' 0.1 Wood 2 Under Attic (Unvented) CLST 4 0 Blown 18 ft' 0.1 Wood 3 Under Attic (Unvented) BATH 3 0 Blown 54 ft' 0.1 Wood _ 4 Under Attic (Unvented) BEDROOM3 0 Blown 132 IF 0.1 Wood _ 5 Under Attic (Unvented) CLST3 0 Blown 16 ft' 0.1 Wood _ 6 Under Attic (Unvented) BATH 2 0 Blown 64 ft' 0.1 Wood 7 Under Attic (Unvented) BEDROOM 0- Blown 140112 0.1 Wood 8 Under Attic (Unvented) CLST 2 0 Blown 16 ft' b.1 Wood 9 Under Attic (Unvented) MUD ROOM 0 Blown-. 105 ft' 0.1 Wood 10 Under Attic (Unvented) AHU CLST 0 Blown 12 ft' 0.1 Wood 11 Under Attic (Unvented) DINING 0 Blown 156 ft' 0.1 Wood _ 12 Under Attic (Unvented) FOYER 0 Blown 94 ft' 0.1 Wood _ 13 Under Attic (Unvented) KITCHEN 0 Blown 358 fF 0.1 Wood 14 Under Attic (Unvented) LIVING ROOM" 0 'Blown 202 ft' 0.1 Wood _ 15 Under Attic (Unvented) FAMILY ROOM 0 Blown 247 ft' _ 0.1 Wood 16 Under Attic (Unvented). HALL 0 Blown 32 R2 0.1 Wood 17 Under Attic (Unvented) HALL2 0 Blown 40 ft' 0.1 Wood 18 Under Attic (Unvented) MASTER BEDRO 0 Blown 271 ft' 0.1 Wood _ 19 Under Attic (Unvented) M WIC 1 0 Blown 49IF 0.1 Wood _ 20 Under Attic (Unvented) MWIC2 0 Blown 54 ft' 0.1 Wood _ 21 Under Attic (Unvented) M BATH 0 Blown 234 ft' 0.1 Wood _ 22 Under Attic (Unvented) M TOILET 0 Blown 20 ft' '0.1 Wood 23 Under Attic (Unvented) W/D 0 Blown 24 ft' 0.1 Wood 24 Under Attic(Unvenled) POWDER RM 0 Blown 36 ft' 0.1 Wood, 25 UnderAttic (Unvented) GAME ROOM 0 Blown 248 ft' 0.1 Wood WALLS it r)�t Adjacent To 11VAIT Type Space Cavity Width Height Sheathing Framing Solar Below _ i S Exterior Concrete Block- Ext InstZEDROOM 4 5 13 0 10 0 130.0 ft' 0 0 0.4 0 _ 2 W Exterior Concrete Block- Ext InsiSEDROOM 4 5 12 0 10 0 120.0 fl' 0 0 0.4 0 3 W Exterior Concrete Block- Ext Insul CLST 4 5 2 0 10 0 20.0 ft' 0 0 0.4 0 4 W Exterior Concrete Block - Ext Insul BATH 3 5 6 0 10 0 60.0 ft' 0 0 0.4 0 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 J FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 5 W Exterior Concrete Block- Ext InsiBEDROOM 3 5 11 0 10 0 110.0 ft? 0 0 0.4 0 6 W Exterior Concrete. Block- Ext Insul CLST 3 5 2 0 10 0 20.0 ft' 0 0 0.4 0 _ 7 W Exterior Concrete Block- Ext Insul BATH 2 5 8 0 10 0 80.0 ft. 0 0 - 0.4 0 _ 8 W Exterior Concrete Block- Ext InstMEDROOM 2 5 11 0 10 0 110.0 ft' 0 0 0.4 0 _ 9 W Exterior Concrete Block- Ext Insul CLST 2 5 2 0 10 0 20.0 ft' 0 0 0.4 0 _ 10 N Garage Frame - Wood CLST 2 11 8 0 10 0 80.0 ftZ 0 0.1 0.4 0 _ 11 N Garage Frame - Wood MUD ROOM 11 9 0 10 0 90.0 ft. 0 0.1 0.4 0 _ 12 N Exterior Concrete Block- Ext Insul DINING 5 13 0 10 0 130.0 R' 0 0 0.4 0 13 E Exterior Concrete Block-Ext Insul DINING 5 1 0 10 0 10.0 ft' 0 0 0.4 0 _ 14 W Garage Frame - Wood DINING 11 2 0 10 0 20.0 ft' 0 •0.1 0.4 0 _ 15 N Exterior Concrete Block - Ext Insul FOYER 5 9 0 10 0 90.0 ft- 0 0 0.4 0 _ 16 E Exterior Concrete Block - Ext Insul KITCHEN 5 10 0 10 0 100.0 ft' 0 0 0.4 0 _ 17 S Exterior Concrete Block - Ext Insul KITCHEN 5 4 0 10 0 40.0 ft2 0 0 0.4 0 _ 18 S Exterior Concrete Block - Ext InsdIIVING ROO 5 11 0 11 0- 121.0 ft' 0 - 0 0.4 0 _ 19 E Exterior Concrete Block - Ext Ins614MILY ROO 5 14 0 11 0 154.0 ft' 0 0 0.4 0 _ 20 E Exterior Concrete Block- Ext InsUMASTER BE 5 17 0 11 0 187.0 ft' 0 0 - 0.4 0 21 S Exterior Concrete Block- ExtInsdMASTER BE 5 3 0 11 0 33.0 ft' 0 0 0.4 0 _ 22 SW Exterior Concrete Block- Ext InstW1ASTER BE 5 7 3 11 0 79.8 R' 0 0 0.4 0 _ 23 E Exterior Concrete Block- Ext Insul M WIC 1 5 7 0 10 0 70.0 ft' 0 0 0.4 0 _ 24 S Exterior Concrete Block- Ext Insul M WIC 1 5 1 0 10 0 10.0 ft' 0 0 0.4 0 _ 25 N Exterior Concrete Block -. Ext Insul M BATH 5 14 0 10 0 140.0 ft' 0 0 0.4 0 26 E Exterior Concrete Block - Ext Insul M BATH 5 '10 0 10 0 100.0 ft' 0 0 0.4 0 _ 27 W Exterior Concrete Block - Ext Insul M BATH 5 13 0 10 0 130.0 ft' 0 0 0.4 0 _ 28 N Exterior Concrete Block - Ext Insults TOILET 5 4 0 10 0 40.0 ft' 0 0 0.4 0 _ 29 E Exterior Concrete Block - Ext InsulM TOILET 5 5 0 10 0 50.0 ft' 0 0 0.4 0 _ 30 N Garage Frame - Wood W/D 11 4 0 10 0 40.0 ft' 0 0.1 0.4 0 _ 31 W Garage Frame - Wood W/D 11 6 0 10 0 60.0 R' 0 0.1 0.4 0, 32 E Exterior Concrete Block-.Ext InsUPOWDER R 5 6 0 10 0 60.0 ft' 0 0 0.4 0 33 S Exterior Concrete Block -Ext InsUPOWDERR 5 6 0 10 0, 60.0 ft' 0 0 0.4 0 _ 34 W- Exterior Concrete Block - Ext InsdPOWDER R 5 6 0 10 0 60.0 ft' 0 0 0.4 0 _ 35 E Exterior Concrete Block - Ext InsmAME ROOM 5 15 0 10 0 150.0 ft' 0 0 0.4 0 36 S Exterior Concrete Block- Ext Ins01AME ROOM 5 17 0 10 0 170.0 ft' 0 0 0.4 0 DOORS # - Omit Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .4 6 8 48 f 2 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software I Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown Is the entered, Proposed orientation. /. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft' 2 ft 0 in 0 ft 7 in None None _ 2 W 2 Metal Low-E Single Yes 0.55 0.22 N 15.0 ftz 2 ft 0 in 0 ft 7 in None None 3 - W 4 Metal Low-E Single Yes 0.55 0.22 N 6.0 ft' 2 ft 0 in 0 It 7 in None None _ 4 W 5 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft' 2 It 0 in 0 ft 7 in None None _ 5 W 7 Metal Low-E Single Yes 0.55 0.22 N 6.0 ft'- 2 ft 0 in 0 ft 7 in None None _ 6 W 8 Metal,_Low-E Single Yes 0.55 0.22 N 15.0 B' 2ft 0 in 0 ft 7 in None None _ 7 N 12 Metal Low-E Single Yes 0.55 0.22 N 36.0 ft' 8 ft 0 in 0 It 6 in None None 8 E 16 Metal Low-E Single Yes 0.55 0.22 N 20.0 W. 8 ft 0 in 0 It 7 in None None 9 S 18 Metal Low-E Single Yes 0.55 0.22 N 72.0 ft' 14 It 0 in 0 It 7 in None - None 10 E 19 Metal Low-E Single Yes 0.55 0.22 N 72.0 ft' 2 it 0 in 0 It 7 in None None 11 £ 20 Metal Low-E Single Yes 0.55 0.22 N 20.0 ft' 2 ft 0 in Oft 7 in None None 12 SW 22 Metal Low-E Single. Yes 0.55 0.22 N 46.7 ft' 14 ft 0 in 0 It 7 in None None 13 N 25 Metal Low-E Single Yes 0.55 0.22 N 25.0 ft' 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 _ 14 E 29 Metal Low-E Single , Yes 0.55 - 0.22 , N 9.0 R' 2 ft 0 in 0 ft 7 In None None 15 W 34 Metal Low-E Single Yes 0.55 0.22 N 20.0 ft' 8 It 0 in 0 It 7 in None None 16 E 35 Metal Low-E Single Yes 0.55 0.22 , N 48.0 ft' 2 ft 0 in 0 ft 7 iri None None 17 S 36 Metal 'Low-E Single Yes 0.55 0.22 N 12.0 ft2 2 ft 0 in 0 It 7 in None None GARAGE # Floor Area. ' Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 546 ft' 546 ft' 29 ft loft 11 INFILTRATION # Scope Method SLA CFM'50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000456 3325 182.54 343.29 .1747 7 HEATING SYSTEM # System Type Subtype Speed Efficiency - Capacity Block Ducts 1 Electric Strip Heat/ None COPAL 34 kBtu/hr 1 sys#1 COOLING SYSTEM ` # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit! Spin Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 ' 1 s sys#1 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20)7) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM '# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage. Cart # Company Name System Model # Collector Model # Area Volume FIEF None None ft' DUCTS / ---- Supply — — Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft' Attic 20 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Venting Feb Mar Mar Apr Apr May May fX� Jun [ j Jul f ] [X] Aug f ] [x] Sep [ ] ffX11 L 1 Oct NovfDec Nov Decec [ ]Jan l l l^l tXl Jun [ 1 Jul [ 1 Aug [ 1 Sep lxl - [X] [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 66 68 66 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 R 0.3 BEDROOM 4 Default(8 lbs/sq.ft. ft' it 0.3 .CLST4 Default(8 lbs/sq.ft. ft' ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM3 Default(8 lbs/sq.ft. ft' ft 0.3 CLST3 Defaull(8lbs/sq.ft. ft' ft 0.3 BATH 2 Default@ lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 CLST2 Default(8 lbs/sq.ft. ft' ft 0.3 MUD ROOM Default(8 lbs/sq.ft. ft' ft 0.3 AHU CLST Default(8 lbs/sq.ft. ft' It 0.3 DINING Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft, ft' ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft' ft 0.3 FAMILY ROOM Default(8 lbs/sq.ft. ft' ft 0.3 HALL 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. It, It 0.3 HALL 2 Default(8 lbs/sq.ft. ft' It 0.3 MASTER BEDROO Default(8 lbs/sq.ft. W It 0.3 M WIC 1 Default(8 lbs/sq.ft. ft' ft 0.3 M WIC 2 Defauft(8 lbs/sq.ft. ft' ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 H 0.3 M TOILET Defauft(8 lbs/sq.fL ft' ft 0.3 W/D Default(8 lbs/sq.ft. ft' ft 0.3 POWDER RM Default(8 lbs/s.ft. ft' ft 0.3 GAME ROOM 1 11/5/2019 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 - wrightsoft Project Summary Date: Sept. 24,2019 a Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772-46GV99 Fax: 772-4668/96 Emit: OUICKCALCS@AOLCOM V •ect Information For: 1313BLONE PANE DRNE, FORT PIERCE, L Notes: SCANNED BY St. Lucie County Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db , 75 OF Design TD 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 35477 Btuh Structure 28969 Btuh Ducts 9175 Btuh Ducts 6663 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 44652 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmerrt sensible load 33851 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3175 Btuh Ducts 3628 Btuh Central vent (0 cfm) 0 Btuh Heating Cool ingg Area (none) (ft� 2778 29nA Equipment latent load 6802 Btuh Volume (ft3) 28500 28500 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 40653 Btuh Equiv. AVF (cfm) 152 76 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6049J1 AHRI ref Coil TEM4AOC48S41++TDR AHRI ref 8676081 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER ' Heating input 12.3 kW Sensible cooling 32550 Btuh Heating output 42015 Btuh Latent cooling 13950 Btuh . Temperature rise 25� OF Total cooling e�n19 46500 Btuh Actual air flow 1550 cfm Actual air flow Q 8 NQ� 550 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 043 cfr Static pressure 1.00 in H2O Static pressure @ 00 it Space thermostat Load sensible heatratio' ® 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Ri9htSuite® Un'rversa1201919.0.08 RS1J08101 ...nets\Wri9htsoft HVAC\TILLBERG RES- GEM BLDR.mp Cale = MJB Front Door faces: N wrightsofr Right-M) Worksheet Job: Entire House Date: Sept. 24, 2019 � By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax: T72-466-6795 Email: QUICKCALCS@fOLCOM 1 Room name Entire House BEDROOM 4 2 Exposed wall 280.2 it 25.0 it 3 Room heigit 10.3 it 10.0 ft heat/cool 4 Room dimensions 13.0 x 12.0 it 5 Room area 2778.0 fF 156.0 ft' Ty Construction number LI-value (Btuhlf k F) Or HTM (BtuWft2) Area or perimeter (ft) Load (81uh) oorperimeter (it) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 VVV[ 1345ocs 2 glazing, clrlow- 2 glazing, cir low- 0.125 0.650 0.650 ri n n 3.50 18.20 18.20 - 1.91 14.99 14.99 554 12 15 465 0 0 '1625 218 273 889 180 225 130 0 15 115 0 0 403 0 273 _ 220 0 225 W 11 2 glazing, clr low-e -. 1345ocs 0.650 0.125 n ne 1820 3.50 14.99 1.91 _ 72 79 - 0 33 1310 114 1079 GL - . _0 0 - 0 0 0 0 0 0 L--G 2 olazina, cir low- _ 134-5ocs 2 glazing, cir low- O.650 0.125 0.650 ne a a 18.20 3.50 18.20 28.88 - -1.91 33.77 .47 730 12 0 - 653 0 _ 849 2286 218 1254 1249 405 0 120 0 _ _ 0 105 0 0 368 0 0 201 • 0 2 glazing, cir low- 2 glazing, cir low- 0.6m 0.650 a a 18.20 18.20 33.77 33.77 45 20 0 0 819 . 364 1520 675 15 0 0 0 273 0 507 0 l7! FF�-CCD+ 23ASas 2 glazing, cir low- 2 glazing, cir low- 0.125 O.650 0.650 s s s 3.50 18.20 18.20 1.91 10.68 10.fi8 36 436 25 27 T2 50 1655 456 455 540 267 267 0 0 0 0 0 0 0 0 0 0 0 0 11G0 13A-5ocs - _ 0.540 - 0.125 s w 15.12 3.50 14.31 -1.91 48 - 881 _ 48 712 _ 726 2492 687 1362 0 0' 0 0 0 0 0 0 2 glazing, cir low- 2 glazing, cir low- 2 gazing, cir low- '0.650 0.650 0.650 w w w %20 18.20 18.20 33.77 33.77 33.77 9 20 20 0 0 - 0 164 354 364 304 675 675 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low- 2 glazing, clr low-- 0.650 0.650 w w 18.20 18.20 33.77 33.77 48 72 0 0. 874 1310 1621 2432 0 0 0 0 0 ... 0 0 0 C 16X19-0md 0.408 - 1.59 1.37 2778 2778 4405 3_801 155 156 247 213 F. - _ 22A-tph - _ . 1.358 ,- - 3802 0.00' .2778 _ _ 280 9893. 0 _ 156 -` 25 .. 951 0 6 c)AFD excursion 457 -113 Emlope loss/gain _ 30799 20917 2514 1252 12 a) Infiltration 4677 1253 441 118 . b) Room centilation 0 0 0 0 -13 Internal galm: Occupants @ 230 0 0 0 0 Appliarcestother 6800 SOD Subtotal Qlnes 6 to 13) 35477 28969 2954 1870 Less ekemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution - 0 0 114 42 14 Subtotal 35477 28969 3069 1912 15 _ Duct loads 26% 23% 9175 6663 26% 23% 794 440 Total room load 44652 1 35632 38M 2352 Air required (cfm) 1550 1550 134 102 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t -F}F wrighis M- 2019Sep-Sep10:13:11 Right-Suite(l) RES- G MBDUniversal rup Ca.0.08 R8U0 Front Page 1 ...nets\WngMsoft HVAC\TILLBERG RES GEM BLDR.mp CaIc=MJB Front Door faces: N Z e6ed N :aaOP4 IDo0 lucid 8fW = 01e0 dm'801e W30 -S38 pu3ell11\OVM IPSIOuM1SIOU - MOOV 1oLwnsu 8O'0'6L 6LOL Ies -un wai!nS-i461u •-.-. ....... lG:£L:OL 6Z-daSBLOZ-33osa461+M 'P3 419 f lenueW to sluawaLm al lie laaw of y00y q paAojdde suoilepoleo vz L£ 0 0 (wm) peipbG, Jro Z6S ESOL 0 0 Peol W= IeWl LM . 9LZ %£Z %9Z 0 0 %EZ %9Z spool lon0 SL Lvr Me 0 0 leioi9ns 6L st, Mu 99- OLz- ualuwwSrea 0 0 0 0 ialsueii S-1 0 0 0 0 _ Pool Ime" nal RE 9LL 89 Mz (£L oi9 Sau!D IelolgnS 0 0 Jegio/Seo Bl*ly 0 0 0 0 O£Z @'7 Suednoo0 :su!eB!ewaul EL 0 0 0 0 uo!leiqum woos (q 8Z 9M 6 SE. UO!m it (e ZL 5c Us fib SLL we6/nol edola'w3 EL- uo!mnm O3V(3 9 0' w . e - 9' K 0 - 91 - - z .. _ . aL 00-0 zo Be - 9s£'L 4di-vzz ' d 4L 99 K bS SZ. 6Z SL_ SL L£'L 691 - 9b'0 PwU6LX9L 0 0 0 - 0 _ 0 _ 0 _ 0 - 0 _ 0 LL'££ OZ'8L M 099'0 aMo! i1o'6ulmP Z 0 0 0 0 0 0 0 0 LL:££ OZ'8L M 059'0 aMnl -0o'6L!zel6Z 0. 0 0 0 0 0 0 0 Wee Oz % M 099'0 a -Mal ip'6mze!B Z 0. 0 0 0 0 0 0 0 LL'E£ OZ'BL M 099'0 amj ip'6uize!6 Z 0 0 0 0 - 0 0 0 0 LL££ Oz,% M 099,0 Ip ,SPoSVEG 0 0 0- 0_. 0 0 0 _ .0' L6'L _ Me- a=j 0 0 0 0 0 0 0 0 W14 US S 06S'O 09" 0 0 0 0 0 0 0 0 89'OL OM S 0990 aMa! Jp'6u!ze!6Z 0 0 0 0 0 0 0 0 65"6L Oz,% S 0990 a-ml-0o'6uIMPZ 0 0 0 0 0 0 0 0 161 OS'£ S SU 0 SooSb£L 0 0 0 0 0 0 0 0' LL"Ee '0zm a 099,0 �Mol ip'6u5Z 0 0 0 0 0- �. 0 0 0 LL'££ OM a 0!9'0 a-Mo! i!o CRIB Z EOZ. 60L 0 9 0 0 0 0 LL'E£ OZ'9L a 099'0 a-Mol 40 TUIMBZ £OL 69L 09 09 8E OL- OZ OZ wl 05£ a SZVO �SbEL 0 0 _ 0 _ 0 0 - 0 0 0 99'9Z - OZ'9L eu 099'0 o-Mol-0o' u!Zel6Z 0 0 0- 0 0 0 0 0 Wl 09£ ae SZVO SOOG-M LL _ 0 0 0 - 0 - - _ _ 0 0 0. - - 0 - 66'K OM u. 099'0 - aml-00 TkilmI6Z 0 0 0 0 0 0 0 0 66'6L OZ'8L u 099'0 aml JID UI 16 Z 0 0 0 0 0 0 0 0 663L OZBL u 099'0 aMol-0o'su!zeoZ 0 0 O: 0 0 0. 0 0 ' wl 09'E- u 9ZVO SooSOM 9 M I-H SMIN SSaO 1-0 WH S/d/N S=V log0 ieaH (d,z71Nni8) iegwnu (4njM (iL) iaiawuad io (gnlM (4) iaiawued io (z11M Paul (d11 easy Peol l=7i) ean/ W1H i0 an!en-(1 uo!Mgwoo Al .0 o'vs 4 0 M sale woos 9 it 09 x 0'6 u O'Z x 0'6 wo!Suawlp wooy v loo AM4 4 O'M l000/leeq a 0'OL w6!0I wool:l £ » 09 a Oz Ilm posocb3 z £ Hlva b 1SIO awm waoa l WOO"IOV@SOIVOXOInO :Ilew3 96L9-996-ZLL :M=l 66L9-999-ZLL :auNd 9b66£ ld '30a31d luOd '3NVl mom is LL£ •ONI `so- o moint) :As 66oz'vz'ldas :oleo eSnOH GAIM.9 :qor ;aaysiioM Of -wBlu ,UOS44r)!JM ' Y wrightsoft Right -A) Worksheet Job: Entire House Date: Sept. 24, 2019 ) QUICK CALCS, INC. BY; 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 7724W-6796 Emil: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 CLST 3 2 3 Exi sed wall Room height - 11.0 ft 10.0 It heaticeol 2.0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 12.0 x 11.0 ft 132.0 ft' - 8.0 x 2.0 ft 16.0 w Ty Construction number L)-wlue (Btuh1ftMF) Or HTM (Btuhtfil Area or perimeter M) (Ruh) or�Perimeter (ft) Load (Ruh) Had Cool Gross NIP/S Heat Cool Gross N!P/S Heat Cool 6 ILA 134Socs 2 glazing, clrlow-e 2 glazing, clr Iowa ` 0.650 0.650 0.650 n n n 3.20 18.20 18.20 4:91 1499 14.99 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 -EGG 11 t-G 2 glazing, cir low-e 1345ocs 0.650 0.125 In ne '18.20 3.50 14.99 1.91 __ 0 0 0- 0 0 0 _ 0 0 _ 0 0 0 -0 0 0 0 0 V+1 2 glazino. clr low-e 1345ocs 2 glazing, clr lows _ 0.650 0.125 0.650 ne a a 18.20 3.50 1620 26.88 1.91 33.77 _ 0 110 0 0 9.5 0 0 333 0 0 182 0 0 20 0- 0 20 0 0 70 0 0 38 0 2 glazing, cir Iowa 2 glazing, clrlowa 0.650 0.650 a a 18.20 1620 33.77 33.77 15 0 0 0 273 0 507 0 0 0 0 0 0 0 0 0 1M 1345ocs 2 glazing, clr Iowa 2 glazing, clr Iowa 0. 0.650 0.650 s s s 3.50 18.20 18.20 1.91 14.99 10.6868 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 11GO - 2 0.540 - 0.650 s w 15.12 3.50 14.31 0 -` 0 0 0 0 0 0 0 _ 0 0 0 - 0 0 0 0 0 l 2 glazing, clr Iow-e glazing, 2 glazing, clr Iowa 2 glazing,blr Iowa 0.650 0.650 0.650 w w w 18.20 18.20 18.20 33.77 3.77 3377 33.77 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 2 glazing, clr Iowa. 1fiX19-0md 0.653 0.653 0.408 w w - 18.20 18.20 1.59 33.77 33.77 1.37 0 0 132 0 0 132 0 0 209 0 0 181 0 0 , 16 0 0 16 0 0 25 0 0 22 _ C _ F 22A4ph _ 1.358 - 38.02 _ 0.00 _ 132 11 418 0- _ _ 16 _- _2 76 _ 0 6 c)AED excursion _75 -4 Emlope loss/gain 1233 794 171 55 12 a) Irdiftration 194 52 35 9 b) Room ventilation 0 0 0 0 13 Internal gains: occupants @ 230 0 0 0 0 Appliances/other 850 0 Subtotal Qin es 6 to 13) 1427 1696 207 66 Less e#emal load 0 0 0 0 14 Less transfer Redistrbution Subtotal 0 120 1547 0 46 17,* 0 -207 0 0 56 0 15 Duct loads 2WA 23% 400 401 28% 23% 0 0 Total room load Air required (cfm) 1947 6B 2143 93 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -Fp- wrl9ti of"t- 2019Sep-2410:13:11 RightSuite® Universal 2019 19.0.08 RSU08101 Page 3 ...nets\Wnghtsoft HUAC\TILLBERG RES- GEM BLOR,rup Calc = MJ8 Front Door Faces: N wrightsoft Right-J®Worksheet Job: Entire House Date: Sept. 24, 2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A6"799 Fax 772-466-6796 Email: QUICKCALCS@IOLCOM 1 Room name BATH 2 BEDROOM 2 2 .3 Exposed wall Room height 8.0 It 10.0 ft heat/cool 11.0 It 10.0 ft heat/cool 4 5 Room dimensions Room area 8.0 x 8.0 ft 64.0 ft- 1.0 x 140.0 ft 140.0 ft' Ty Construction U-value Or HTM Area (to toad Area (n Load number (Btuhlft''F) (Btuwft' or perimeter (ft) (Ruh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Ccol Gross WP/S Heat Gool 6 I-G 13ASocs 2glazing, cirlowe 2 glazing, cir Iowa 0.125 0.650 - 0.650 n. n n 3.50 1820 18.20 1.91 14.99 14.99 0 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ��Gi 11 VN 2 glazing,.clr Iowa - 13ASocs C.650 0.125 n ne 18.20 '3.50 _ 14.99 1.91 0 0 0 0 0 - �'0- 0 0 0 0 0 o 0 '0 0 0 �C V�1 I--' 2 glazing, clr lava 13A6ods 2 glazing, cir lava 0.650 0.125 0.650 re a a 18.20 3.50 1820 26.88 1.91 33.77 0 80 6 0 - 74 0 0 259 109 0 142 203 0 110 0 0 95 0 0 333 0 0 182 0 II--(C` 2 glazing, cir Iowa 2 glazing, cir lava 0.650 - 0.650 a e 1620 _ 1820 . 33.77 33.77 0 0 0 0 0 0 0 0 15 0 0 0 273 0 507 -0 VI! 13k.5Dcszing. 2 glazing, cir Iowa 2 glazing, cir lava 0.650 REM 0.650 s s s 3.50 1820 1620 1.91 10.68 10.68 0 0 0 0 0 0 , 0 0 0 0 0 0 0 0 0 - _ 0 0 0 0 0 0 0 0 0 l��-CCD 11G0 13ASocs�- 0.540 "'0.125 s w 15.12 3.50 14.31 .. 1.91 0_ 0 0 0 _ 0_ 0 _ 0 0 0 0 _ 0 0 0 0 0 0 2 glazing, cir lower 2 glazing, co- lava 2 glazing, clr lower 0.650 0.650 0.650 w w w 18,20 18.20 18,20 33.77 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lava 2 glazing, cir Iowa 16X19-0md 0.650 _ 0.650 0.408 w w - 18.20 _ 18.20 1.59 33.77 _ _ 33.77 1.37 0 „ _ 0 64 0- 0 64 0 0 101 0 0 88 0 0 140 0 0 140 0 0 222 0 0 192 _ C _ F_ 22A-tph_.. _ 1.358 -._ - - _35.02 i _ 0.00 _. 64 _ ._ 8: _ 304 ..0 _ _ 140 _ 11 418 0 6 c) AED excursion -16 .72 Envelope loss/gain 774 416 1246 808 12 a) Indftration 141 38 194 52 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/otFgr 0 800 Subtotal Qirles 6 to 13) 915 453 1440 1659 Less wdemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 123 1038 0 49 502 01 232 1671 0 86 1745 15 Duct loads 26°,6 23-A 268 115 26% 23% 432 401 Total room load Air required (cfm) 1306 45 617 27 2103 73 2147 93 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed wrlghtsox- 2019Sep-24 10:13:11 A ' ' RightSuite® Unisersal 2019 19.0.08 RSU08101 Page 4 ...nets%Wdghtsoft HVACITILLBERG RES- GEM BLDR.rup Cale = MJ8 Front Door Faces: N wrightsoftRight-M) Worksheet Job: Entire House Date: Sept.24, 2019 QUICK CA.LCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fax: 772466.6796 Email: OUICKCALCS@,AOL.COM 1 Room nome CLST 2 MUD ROOM 2 Exposed wall 2.0 ft 0 It 3 Room height 10.0 It heat/cool 10.0 ft heat/cool 4 5 , Room dimensions Room area 8.0 x 2.0 ft 16.0 ft- 1.0 x 105.0 It 105.0 ft. Ty Constmction U-value Or HTM Area (ft� Load Area (ft� Load number (Btulyft=°F) (Btulvm or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6% 13ASom 2 glazing, cir Iowa 2 glazing, cir Iowa 0.125 0.650 0.650 n n n 3.50. 18.20 18.20 1.91 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ll-�-�GG W 11 2 glazing, cir Iowa 134-Socs 0.650 0.125 n ne 18.20 3.50 14.99 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 alazioa, cir lava 13A5ocs 2 glazing, cir Iowa 0.650 0.125 0.650 ns a a 18.20 3.50 1&20 25.88 1.91 33.77 0 20 0 0 20 0 0 70 0 0 38 0 0 0 0 __ 0 0 0 0 0 0 0 0 0 __C 2 glazing, cir lowe 2 glazing, cir lowe 1345ocs 2 glazing, cir Iowa 2 glazing, cir lowe 0.650 0.650 0.125 0.650 0.650 a a s s s 18,20 18.20 3.50 18.20 1820 33.77 33.77 1.91 14.99 10.68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11G0 13A5ons 0.540 0.125 s w 15.12 3.50 14.31 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G 2 glazing, cir lava 2 glazing, cir lave 2 glazing, ao- lava 0.650 0.650 0.650 w w w 18,20 18.20 16.20 33.77 33.77 33.77 0 0 o 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lava 2 glazing, cir Iowa 16X19-0md 0.650 0.650 0.408 w w - 11120 11120 1.59 33.77 33.77 1.37 0 0 16 0 0 16 0 0 25 0 0 22 0 0 105 0 0 105 0 0 165 0 0 144 C F 22A4ph 1.358 - 38.02 0.00 . 16 2 _ _ _ 76 0 105 _ 0 0 0 6 c)APD mmlon 4 51 Emelope loss/gain 171 56 166 93 12 a) Infiltration 35 9 0 0 b) Room tentilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 750 Subtotal Qines 6 to 13) 207 66 166 843 Less e)denral load 0 0 0 0 Less transfer 0 0 0 0 RedstribLdion -207 -66 32 26 14 Subtotal 0 0 199 889 15 Duct loads 26,6 23% 0 0 26% 239.6 51 200 Total room bad 0 0 250 1069 Air required (cfm) 0 0 9 46 Calculations aooroved bvACCA to meet all reouirements of Manual J 8th Ed wrrghesoTe- 2019Sep-2410:13:11 Aetk ' RlghtSute®Unrvzrsal2019 19.0.08 RSU08101 Page 5 ...nets%Wdghtsoft HVACITILLBERG RES GEM BLDR.mp Calc = MJ8 Front Door faces: N I# wrightsoft, Right-J®Worksheet Job: Entire House Date: Sept. 24, 2019 QUICK CALCS, INC. By: 317 ST UCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name AHU CLST DINING 2 Eposed wall 0 ft 14.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 3.0 x 4.0 ft 12.0 ft' 13.0 x 12.0 ft 156.0 ft, Ty Corstnlctton U-value Or HTM Area (ft� Load Aroa (ft°) Load number (BtuWft? °F) (Btuwft°) or perimeter (ft) (Btuh) or perimeter (tt) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 V+/ 13AFwcs 2 glazing, cir lave 2 glazirg, cir Iowa 0.125 0.650 0.650 n n n 3.50 1&20 18.20 1.91 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ILA-GGG V,lt 11 2 glazigq, clr Iowa 1345ocs 0.650 0.125 n ne 18.2) 3.50 " 14.99 1.91 _ 0 0 0 0 0 0 0 0 0 0 _ 0_ 0 0 0 0 0 L--G 2 alazinq, clr low¢ 13ASocs 2 glazing, clr Iowa 0.650 0. 0.650650 re a a _ 18.20 3.50 1fl20 26.88 1.91 33:77 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 2 glazing, cir Iowa 13ASocs 2 glazing, cir low¢ 2 glazing, cir Iowa 0.650 0.650 0.650 0.650 0.650 a a s s s 18.20 18.20 3.20 18.20 1fl20 33.77 33.77 1.91 10.68 10.68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 136 36 0 0 0 94 36 D 0 0 650 655 0 0 0 540 540 0 V 11GO 0.540 0.650 s w 15.12 14.31 1.91 0 0 0 0 0 0 0 0 0 10 _ 0 10 0 35 0 19 l�l 23ASoas 2 glazing, cir lows 2 glazing, cir Iowa 2 glazing, cir lava 0.a50 0.650 0.650 w w w 18.20 18.20 1820 18,20 33.77 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IIIF-���GGGa 2 glazing, cir lava 2 glazing, cir Iowa 16X190md 0.650 0.650 0.408 w w - 18.20 18.20 1.59 33.77 33.77 1.37 0 0 12 0 0 12 0 0 19 0 0 16 0 0 156 0 0 156 0 0 247 0 0 213 C F 22A-tph " 1.358 - 38,02 0.00 12 , 0 - 0 _ 0 155 . - 14 _ " 532 0 6 c)AED etaursion -1 .67 Envelope loss/gain 19 15 1799 885 12 a) Infiltration 0 0 247 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 150 Subtotal Qines 6 to 13) 19 15 2046 1101 Less a demal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -19 0 0 -15 0 0 1 2047 0 1 1102 15 Duct loads 26% 23% 0 0 26% 23°h 529 254 Total room bad Air required (cfm) 0 0 0 0 2576 89 1356 59 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -n'}F- w,risr+taof'!- 2019Sep-2410:13:11 . A Right -Suite® Univemal20l9l9.0.OB RSU08101 Page 6 ...netslWrlghtsot HVAC\TILLBERG RES-GEMBLDR.mp Calc= MJ8 Front Door faces: N wrightsoftRight-M) Worksheet Job: Entire House Date: Sept. 24, 2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-b799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name FOYER KITCHEN 2 Flosed wall 9.0 ft 14.0 ft 3 Room height 10.0 it heat/cool 10.0 it heat/cool 4 5 Room dimensions Room area - 1.0 x 94.0 it 94.0 ft2 1.0 x 358.0 ft 358.0 W Ty Construction number U-value (BtuWft-°F) Or HTM (&uWft') Area (ft or meterperi(it) Load (Ruh) Area (ft or perimeter (it) Load (Ruh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 VIjI--G 13AS 2 glazing, clr low-. 2 glazing, clr Im-a 0.125 0.650 O.650 In in In 3.50 18.20 18.20 1.91 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 40 0 0 40 0 0 140 0 0 76 0 0 I--G �- G yl 11 2 glazing, cir low-e 134-5ocs 0.650 0.125 _ In ne 18.20 3.50 14.99 1.91 0 0 0 0 _. 0 0 0 0 0 0 0 0 0 0 0 0 �-C VVjj!! �--G 2 glazing. cU Im-e _ 134-Sots 2 glazing, ctr lowe 0.650 0.125 0.650 ne a a 18.20 3.50 18.20 25.88 - 1.91 33.77 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IL----GG Vtl 2 glazing, co- lowe 2 glazing, cir low- _ 134Socs 2 glazing, cir Icw- 2 glazing, cir love 11G0 13A-5k Q650 0.650 0.650 O.650 0.650 0.540 0.125 a a s s s s w 18.20 18.20 3.20 18.20 18.20 15.12 3.50 33.77 33.77 4.91 10.68 10.68 14.31 _ 1.91 0 0 90 0 0 48 0 0 0 42 0 0 48 0 0 0_ 140 0 0 726 - 0 0 0 80 0 0 _ 687 0 0 - 0_ 0 0 0 0 100 0 0 0 0 0 0 80 0 0 0 0 0 0 280 0 0 0 0 0 0 153 2 glazing, cir low- 2 glazing, clr lcw-e 2 glazing, clr low- 0.650 0.650 0.650 w w w 18.20 18.20 1a20 33.77 33.77 33.77 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 20 0 0 0 0 0 364 0 0 675 2 glazing, clr low- 2 glazing, clrlow- 161(19-0md 0.650 _ O.650 0.408 w w - 18.20 18.20 1.59 33.77 33.77 1.37 0 0 94 0 0_ 94 0 0 0 0 129 0 0_ 356 0 0 358 0 0 568 0 0 490 C F _ _ 22A-tph_ 1,358 . 38.02 0.00 94 - 9 _149 .. 342 0 358 _. 14 532 _ _ 0 6 c)AED excursion -54 177 Envelope loss/gain 1354 842 1884 1571 12 a) Infiltration 159 42 247 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 150 Subtotal nines 6 to 13) 1523 885 2131 1787 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal - 0 0 1523 0 0 885 0 33 2163 0 26 1814 15 Duct loads 26'1(6 23% 394 203 26% 23% 559 417 Total room bad Air rerPnred (cfm) 1916 67 1088 47 2723 95 2231 97 Calculations approved bvACCA to meet all requirements of Manual J Sth Ed - i - =IgftboVt- 201Mep-2410:13:11 RlghtSulte® Unhmmal 2019 19.0.08 RSU08101 Page 7 ...nets\Wrightsoft HVAC\TILLBERG RES- GEM BLOR.rup Calc = MJ8 Front Door faces: N wrightsoft• Right-M) Worksheet Job: Entire House Date: Sept. 24, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax: 772-466-6796 Email: OUICKCALCS@,AOL.COM 1 Room name LIVING ROOM FAMILYROOM 2 E)posed wall 11.0 ft 14.0 It 3 Room helglt 11.0 It heat/cool 11.0 ft heaVccol 4 Room dimensions 1.0 x 202.0 ft 1.0 x 247.0 ft 5 Room area 202.0 ft2 247.0 ft2 Ty Construction U-%olue Or HTM Area (ft2) Load Area (1112) Load number (BtuNft? °F) (Btuhlft� or perimeter (ft) Etuh) or perimeter (ft) (Ruh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat ' Cool 6 1N 13A-9ocs 0.125 in" 3.50 1.91 121 49 172 - 94 0 0' 0 0 2 glazing, cir Iowa 0.650 in 18,20 14.99 0 0 0 0 0 0 0- 0 IL�sfC, 2 glazing, cir lowe 0.650 n 18,20 14.99 0 0 0 0 0 0 0 0 2 glazing, clrirnve 0.650 n.. - 18,20 14.99 72 0 , 1310 1079 0 0 0 0 11 W 134-5ocs 0.125 re 3.50 1.91 0 _ 0 .,, 0 0 0 0 0- _ , 0 �G 2 dazira, clr bwe 0.650 ne 1820 26.88 0 0 0 0 0 0 0 0 IN 1345ocs 0.125 a 3.50 1,91 - 0 - 0 - 0 0 ' 0 0 0 _ '0 2 glazing, cir lowe 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 ICI----GGG 2 glazing, cir low-e 0.650 a 18.20 ` 3377 .0 0 0 0 0 0 0 0 2 glazing, clr.lowe.. 0.650 a 18.20 33.77 o 0'_., 0 0 0 0 0 0 1M 13gS0cs - 0.125 s 3.50 1.91 0 0 0 .. 0 0 0 _ 0 0 2 glazing, clr Iowa 0.650 s 18.20 14.68 0 0 0 0 0 0 0 0 2 gazing, clr Iowa 0.650 s 18.20 t0.fi8 0 0 0 0 0 0 0 0 11GO 0.540 s 15.12 14.31 0 0 0 0 0 0 0 13A5ocs -- - - 0.125 -w -3.50 -1.91 0. - 0 -0 0 - 0 154 - 82 287 _ '157 2 glazing, cir Iowa "'0.650 w 18.20 33.77 0- 0 0 0 .0 0 0 0 2 glazing, co- Iowa 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 w 1620 33.77 0 0 0 0 0 0 0 0 2 glazing, cir lowe 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.650 _ w 18.20 33.77 0 0 0 0 -276 72 0 1310 2432 C 16)(19-0md 0.408 - 1.59 202 3M _ 247 247 338 _ _ F - . _ 22AAph�.� ., _ _ .. _1,358. _ --'„ 33.02 _1.37 0.00 _ _•. 202. _ _202 _ 11 _- 418. - 0 - _.247 121 _392 .532 .- ,_0 6 c)AEO excursion -220 796 Envelops loss/gain 2220 1220 2521 3722 12 a) Infi@ration 213 57 271 73 b) Room ventilation 0 0 0 0 13 Internal gaim: Occupants @ 230 0 0 0 0 Appliances/other 2500 0 Subtotal (tires 6 to 13) 2434 3777 2793 3795 Less eldemel load 0 0 0 0 Less transfer 0 0 0 0 Redstnlx3ion 0 0 14 11 14 Subtotal 2434 3777 2807 3806 15 Duct loads 26% 23% 629 869 26% 2356 726 875 Total room load 30M 4646 3632 4682 Air required (cfm) 106 = 123 204 Calculations approved W ACCA to meet all reouirements of Manual J 8th Ed -PI&- w�'�9timo�� 2019Sep-2410:13:11 A=� - RightSulte® UnNemal 2019 19.0.08 RSU08101 Page 8 ...nets\Wdghtsoft HVAC\TILLBERG RES- GEM BLDR.mp Cale = MJ8 Front Door faces: N 1 wrightsofv Right-M Worksheet Job: Entire House Bate: Sept. za, zos By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-46rW96 Email: OUICKCALCS@AOL.COM 1 Room name HALL HALL 2 2 Exposed wall O ft O ft 3 Room height 10.0 ft heallcool 10.0 ft heat/cool 4 5 Room dimensions Room area 4.0 x 8.0 ft 32.0 W 4.0 x 10.0 ft 40.0 ft Ty Construction LLvalue Or HTM Area (ft� Load Area (ft� Load number (Btukft' ° (Btuwft5 or perimeter (ft) (&uh) or perimeter (ft) (Btuh) Heat Cool Gross N1PlS Heat Cool Gross WPIS Heat Cool 6 . V�I1-1'' Ir„ 1345ocs 2 glazing, clr lower 2 glazing, clr lower 0.125 0.650 '0.650 n -n n 3.50 18.20 1a20 1.91 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 11 t-G y/ 2glazing, d0ow�, 13A5ocs 0.650 0.125 n ne 18,20 3.50 14.99 1.91 0 0 0 0 0 0 _ 0 0 _. 0 0 0 0 0 0 _ 0 0 L-G 4)/ 2dazim. cir lower 234Socs glazing, clr lower _ 0.650 0.125 0.650 ne a a 18,20 8,20 1fl20 _26.88 1.91 93.91 0 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 0 0 0 _ .0 0 0 0 0 0 IFF---CGG' 2 glazing, cir lower 2 glazing, cir Iow- 0.650 0.650 a e 1a20 _ 18,20 33.77 33.77 0 _. 0 0 0 0 _ 0 0 . _ 0 0 0 0 0 _ 0 0 0 VII I�-BCD` 13450cs 2 glazing, cIr low -a 2 glazing, clr lows 0.50 .6650 -00.650 s s s 3.50 id20 18.20 1.91 1.8 10.68 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 -0 0 0 0 0 0 0 0 0 0 11G0 13AS0cs - - - 0.540 _ -0.125 s w 15.12 3.50 _ _14.31 1.91 _ 0 0 0 0 0 - 0 0 - 0 0 0 0 - - 0 0 0 _ 0 0 2zglazing, cir lows 2 glazing, cir lowe glazing, cir ww-e 0.650 0.650 0.650 w w w WO '11120 lazo 33.77 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low- 2 glazing, cir low- 16X19-0md 0.650 0.650 0.408 w _w. - 18.20 18.20 1.59 3377 33.77 1.37 0 0 32 0 _ 0 32 0 0 51 0 0 44 0 0. 40 -0 0 40 0 0 63 0 0 55 C F , . 22A4ph� .;- 1.358 - 31102 _ - 0.00 _. .32 '0 .0 0 _ 40 0 _ _ 0 _ _0 6 c) AED excursion 3 i 3 Envelope loss/gain 51 41 63 52 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (liras 6 to 13) 51 41 63 52 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redstribution 51 41 -63 52 14 Subtotal 0 0 0 0 15 Duct loads 26% 23^b 0 0 26% 23-A 0 0 Total room load 0 0 0 0 Air required (dim) 0 0 0 0 Calculations approved IgVACCA to meet all requirements of Manual J 8th Ed. -Fla- wrl9ti�o> - A... 2019Sep-2410:13:11 Page 9 esWrightsoft HVACITILLBERG RES-GEMBLDR.mp Colo =MJ8 Front Door faces: N . + I wrightsofC Right-M Worksheet Job: Entire House Date: Sept. 24, zots By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M W IC 1 2 Exposed wall 27.2 It So It 3 Room height 11.0 ft heat/cool 10.0 It heat/cool 4 5 Room dimensions Room area 1.0 x 271.0 it 271.0 ft- 7.0 x 7.0 ft 49.0 ft- Ty Construction number U-value (Btuhlftk- Or HTM (Btuwm Area (11� or perimeter (ft) Load (Btuh) Area (M or perimeter (It) Load (Btuh) Heat Cool Gross N7PIS Heat Cool Gross WP/S Heat Cool 6 v �1' -13Abacs 2 glazing, cir lows 2 gazing, clr lower 0.125 0.650 0.650 n n n 3.50 1&20 18.2D 1.91 14.99 14.99 33 0 0 33 0 0 116 0 0 63 0 0 10 0 0 10 0 0 35 0 0 19 0 0 L(-(C' 11 2 glazing, cir low- 134 Socs 2 d2inq. cir low- 13A5ocs 2 glazing. cir low- 2 glazing, cir love 2 glazing, cir low- 13450cs 2 glazing, cir law- 2 glazing, cir low- 11G0 13ASocs - 2 glazing, cir low- 2 glazing, clr low- 2 glazing, cir low- 2 glazing, clr low- 2 glazing, cir law- 16X19-0md _ 0.650 0.125 0.650 0.125 0.650 0.650 0.650 0.125 0.650 0.650 0.540 0.125 0.650 0.650 0.650 0.650 0.650 0.408 :n. ne ne a a a a s s s s w w w w w w - 11120 3.5D 11120 3.50 18.20 18.20 1&20. 3.50 18.20 18.20 15.12 3.50 1&20 1&20 11120 18.20 18.20 1.59 14.99 1.91 _ 26.88 1.91 33.77 33.77 33.77 1.91 14.99 10.68 14.31 -1.91 33.77 33.77 33.77 33.77 33.77 1.37 0 79 --47 0 0 0 0 0 0 0 0 187 `:0 '20 0 0 0 271 0 33 0 0 0 0 0 0 0 0 0 - 167 0 0 0 0 0 271 0 114 _ 849 0 0 0 0 0 0 0 0 585 0- 354 0 0 0 430 0--" 62 1254 0 0 0 - 0 0 0 0 0 319 0 675 0 0 0 371 0 0 - 0 0 0 0 - 0 0 0 0 0 70 0 . 0 0 0 0 49 0 0 ---0 0 0 0 0 0 0 0 0 70 0 0 0 0 _ 0 49 0 0 _ 0 - 0 0 0 -. :. 0. 0 0 0 0 245- 0 0 0 0 0 78 0 0 _ _ _ 0 0 0 0 '0 0 0 0 - 0 134 0 0 0 0 0 67 Vdl LG _ C F 22A-tph-. _ 1:358 - 3102 _ Q00 _ 271 _27 _ 1033 _ 0 49 _ _ 8 304 .. 0 6 c)AED excursion -217 -15 Envelope lossigain 3490 2529 em 205 12 a) Infiltration b) Room ventilation 527 0 141 0 141 0 38 0 13 Infernal gains: Occupants @ 230 0 0 0 0 Apdiaxxs/other 900 0 Subtotal (Iinxs 6 to 13) 4018 3570 803 243 Less e#emai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4018 3570 803 243 15 Duct loads 26% 23% 1039 821 26% _ 23% 208 56 Total room load 5057 4391 1010 299 Air required (dm) 176 191 35 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i}F wrt-ghbow- 2019Sep-2410:13:11 G`A RightSuite® Universal 2010 19.0.08 RSW8101 Page 10 ...nets\Wrightsoft HVAC\TILLSERG RES- GEM BLDR.mp Calc = MJ8 Front Door faces: N wrightsofto Right-M Worksheet Job: Entire House Date: Sept. 24, 2049 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-4656796 Email: OUICKCALCS@AOL.COM 1 Room name M WIC 2 M BATH 2 Bposed wall 0 it 37.0 it 3 Room height 10.0 ft heat/cool 10.0 it heat/cool 4 Room cLmersions 1.0 x 54.0 ft 1.0 x 234.0 It 5 Room area 54.0 ft- 234.0 ft- Ty Construction LWalue Or FiTNI Area (ftTj Load Area (" Load number (BtuWft? °F) (&ulyfl=) or perimeter (ft) (Btuh) or pedmeter (ft) (auh) Heat Cool Gross WPIS Heat Cool Gross WP/S Heat Cool 6 W 1345ocs 0.125 n 3.50 - -1.91 0 0 0 0 0 0 0 1 0 {L�-EGG 2 glazing, clr low-e 0.650 n 1&20 14.99 0 0 0 0 0 0 0 0 2 glazigg, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2glazilg, clr low- _ 0.650 n 18.20 14.99 0 - 0 0 0 _ 0 _ 0 _ 0 0 11 Yd 13ASocs 0.125 ne 3.50 1.91 0 0 0 0 0- 0 0 0 �-1' 2 alazirta, clr low-e 0.650 ne 18.20 28.88 0 0 0 0 0 0 0 0 Vj{l-G 13ksocs 0.125 a 3.50 1.91 0 0 0 _ 0 130 _ 130 455 249 2 glazing,clr low-e 0.650 a 1&20 33.77 0 .. 0 0 0 0 0 0 0 1-G L-G 2 glazing, clr low-e 0.85=0 a 1&20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.650 e 18.20 33.77 0 0 ,. 0 0 0 0 0 0 v11. _ 134Socs 0.125 s _ - 3.50 1.91 0 - _ 0 0 0 140 115 403 220 2 glazing, clr low-e 0.690 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s la20 10.68 0 0 0 0 25 25 455 267 11G0 0.540 s 15.12 14.31 0 0 0 0 0 0 0 0 13ASocs _ 0.650 w 3.50 3..77 _ - 0 1.0 _- 0 100 100 350 190 2 glazing, clr low- 0.650 w 1a20 33.77 0 0 0 0 01 0 0 0 0 2 glazing, clr low-e 0.650 w 1d20 33.77 0 0 0 0. 0 0 0 2 glazing, clr bwe 0.650 w 11120 33.770 0 0 0- O 0 0 0 2 glazing, clr low-e 0.650 w 18,20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.650 w 18.20 33.77 , 0 0 0 0, 0_ 0 0 0 C 16X19-0md_ 0.408 - 1.59 1.37 54 54 86 74 234 234 371 320 F.-_ _ .22A-tpti _. 1.358 _- 3B.02 0.00 _ _ .54 _ 0 0 0 - -234 - 37 _ _ 1407 0 6 c)AED excursion 4 81 Errelope loss/gain 86 70 3440 lies 12 a) lrifiRration 0 0 652 - 175 b) Room ventilation 0 0 0 0 13 Intenal gains: Occupants @ 230 0 0 0 0 Appliancesfother 0 0 Subtotal (lines 6 to 13) 86 70 4092 1340 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redstdbution 0 0 0 0 14 Subtotal 86 70 4092 I= 15 Duct loads 26% 23% 22 16 26% 23% 1058 308 Total room load 103 86 5151 16M Air required (cfm) 4 4 179 72 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PFF wrrgtitsoft- 2019-Sep-2410:13: 11 " ' RiG RES- G Universal wp ale =6 RSU081 Front Page 11 ...nets\WnBhtsoR FNAC\TILLBERG RES- GEM BLDR.rup CaIc=MJ6 Front Door laces: N wrightsoft' Right-M) Worksheet Job: Entire House Date: Sept. 24, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOLCOM i Room name M TOILET W/D 2 Exposed wall 9.0 ft 0 ft 3 Room height 10.0 ft heatfcool 10.0 ft heatfcool 4 Room dimensions 4.0 x 5.0 ft 4.0 x 6.0 ft 5 Room area 20.0 fP 24.0 iF Ty Construction uArd a Or HTM Area (" I Load Area (ft2) Load number (BtuWffF) (Btuh/ft2) or perimeter (ft) (Ruh) or perimeter (it) (Ruh) Heat Cool Gross WP/S Had Cool Gross WPIS Heat Cool 6 : V�/ �-G 134-5ocs 2 glazing, cir lower 2 glazing, cir Iowa 0.125 0.650 0.650 n n n 3.50 18.20 18.20 -1.91 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 L�-GG 2 glazing, cir Iowa. 0.650 n 18.20 14.99 -- 0 - 0 0 0 0 0 0 0 11 134bocs 0.125 ne 3.50 1.91 0 0 0 0 0 0 0 0 LG W , ILA--(GG 2 clazim, clr Iowa 13A-Socs - 2 gazing, cIr Iav4 0.650 0.125 0.650 _ ne a a 18.20 3.50 18.20 _26.88 1.91 33.77 0 - 0 - 0 0 0- 0 0 0 0 .. 0 0- 0 0 0 0 0 0 0 0 0' 0 0 0 0 2 gazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0' 0 2 gl trig, cir Iowa 0.650 a 18.20 33.77 0 0_ 0 - 0 - 0 0 0 0 VI! 1345ocs 2 glazing, cir Iowa 2 glazing, cir Iowa 0.650 0.650 0.650 s s s 3.20 18,20 1620 1.91 10.68 10.68 40 0 0 40 0 0 140 0 0 76 0 0 0 0 0 0 0 0 0 0 0 0 0 0 III------C4 11G0 13A-5ocs - _ 0.540 ..- 0.125 a • w 15.12 3.50 14.31 -1.91 _ 0 50 _ 0 41 _ 0 144 _ 0 78 0 0 0 0 0 .... 0 0 0 2 glazing, cir Iowa 2 glazing, cir Iowa 2 gazing, clr Iowa 0.650 0.650 0.650 w w w 1820 18.,20 20 18.203 33.77 3.77 3:77 9 0 0 0 0 0 164 0 0 304 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 2 gazing, clr Iowa 16)(19Omd 0.650 0.650 0.408 w w - 11120 18.20 1.59 33.T7 33.77 1,37 0 0 20 0 0 20 0 0 - 32 0 0 27 0 0 24 0 0 24 0 0 38 0 . 0 - 33 C_ F .. _ 22A-tph _ _ 1.358 _ - . 3802 _ , 0.00 _ .- 20 - 9 342 0 _ _ 24 0 0 - 0 6 c)AED excursion 91 -2 Emeiope loss/gain 821 577 38 31 12 a) Infiltration 159 42 0 0 b) Room ventilation 0 - 0 0 0 13 internal gains: Owupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal Vines 6 to 13) 980 619 38 31 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redstribldion 0 0 38 31 14 Subtotal 980 619 0 0 15 Duct loads 26% 23% 253 142 26% 23°,6 0 0 Total room load 1 1 1233 762 0 0 Air required (cfm) 43 33 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrlghcsoR - 2019Sep-2410:13:11 CAA Right-SuiteG univema12019 19.0.08 RSLO8101 Page 12 ...nets\Wrightsolt HVACITILLBERG RES GEM BLDR.rup Calc = MJ8 Front Door aces: N �+wrightsoft, Right-JOWorksheet Job: Entire House Date: Sept. 24, 2019 QUICK CALCS, INC. By. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772-456-6799 Fax 77246"796 Email: QUICKCALCS@AOL.COM i Room name POWDER RM GAMEROOM 2 Exposed wall 18.0 ft 32.0 It 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 It 36.0 ft- 1.0 x 248.0 ft 248.0 ft' Ty Constmction U-wlue Or HTM Area (ftl Load Area Load number (Btuh/ft' F) (Duh/M or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 lN. Ili 1345ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.125 0.650 0.650 n _ n n 3.50 1820 1&20 1.91 14.99 14.99 60 0 0 60 • 0 0 210 0 0 ' 115 0 0 - 170 12 0 158 0 0 553 218 0 302 180 0 -EGG 11 IN 2 glazing, clr I6we 134-5ocs 0.650 0.125 n. ne _1&20 3.50 ` -14.99 1.91 _ 0 0 _ 0 0 0 0 .0 0 D 0 -0 0 0 0 _ 0 0 W , 2 glazlnp, dr lav_e 134-5ocs 2 glazing, clr lowe 0.650 0.125 0.650 ne a a 18.20 3.50 18.20 26.88 1.91 33.77 0 60' 0 O 40 0 O 140 0 0 76 0 0 " 0 0 0 - 0 0 0 - 0 0 0 0 0 I[-GGG 2 glazing, olr Iowa 2 glazing, clr Iowa 0.650 Q650 a a 1&20 1820 33.77 33.77 0 20 0 0 0 364 0 675 0 0 0 0 0 0 0 0 13A5ocs 2 glazing, clr Iowa 2 glazing, clr Iowa 0.125 0.650 0.650 s s s 3.50 1&20 18,20 1.91 14.99 10.68 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11GO _ _ 0.540 0.650 _s w 15.12 3.50 14.31 1.91 0 60 0 60 _ 0 210 0 110 0 150 0 100 0_ - 3 0 190 2 glazing,. clr low-e 2 glazing. 2 g1mig, clr lowe 2 glazug, drlowe 0.650 0.650 0.650 w w w 18,20 18.20 1&20 33.77 33.77 � 33:77 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 '0 0 0 0 0 0 2 glazing, clr Iowa 0.650 w -18.20 33.77 0 0 0 0 48 0 874 1621 2 glazing, clr lowe 16X19{1md 0.650 0.408 w - 1820 1.59 _ 33.77 1.37 0 36 0- 36 _ 0 57 0 49 0 248 0 248 0 393 0 339 C F, - . 22A-tph - . 1.358 - 38.02 0.00 _ _ 36 - _ 18 684 0 _ 248, 32 _ 1217 - 0 6 c)AED ela:ursion -28 448 ErnIope loss/gain I 1666 1003 3612 3086 12 a) Infiltration 317 85 564 151 b) Room ventilation 0 0 - 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 200 Subtotal Oines 6 to 13) 1983 1088 4176 3437 Less a demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 7 6 14 Subtotal 1983 1088 4183 3443 15 Duct bads 28% 23% 513 250 26% 23% 1082 792 Total room load 2495 1338 5265 4234 Air required (dim) 87 58 183 184 Calculations aooroved bvACCA to meet all requirements of Manual J 8th Ed 'fj'F wrr9ti>mof!- 2019-Sep-2410:13:11 ' RightSufte® Universal 2019 19.0.08 RSUOB101 Page 13 ...nets\Wnghtsoft WAC\TILLBERG RES- GEM BLOR.mp Calo = MJ8 Front Door faces: N wrightsoft Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A6"799 Fax 772.466.6796 Email: OUICKCALCS@AOLCOM Project• • For: TILLBERG RESIDENCE, GEM BUILDERS 1313 LONE PINE DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length,(TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm Job: Date: Sept. 24, 2019 BY: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm 214 ft Name Design (Btuh) Htg (cfm) CIg (cfm) Design FIR Diam (in) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1306 45 27 1.000 5.0 Ox 0 VIFx 17.0 115.0 st1 BATH 3 h 1053 37 24 1.000 5.0 Ox 0 VIFx 34.8 135.0 st3 BEDROOM 2 c 2147 73 93 1.000 7.0 Ox 0 VIFx 8.6 115.0 st1 BEDROOM c 2143 68 93 1.000 7.0 0x0 VIFx 29.8 135.0 st3 BEDROOM h 3862 134 102 1.000 7.0 Ox0 VIFx 46.2 155.0 st4 DINING h 2576 89 59 1.000 6.0 Ox0 VIFx 25.8 115.0 st2 FAMILY ROOM C 2341 61 102 1.000 7.0 Ox0 VIFx 37.2 135.0 st3 FAMILYROOM-A C 2341 61 102 1.000 7.0 Ox0 VIFx 29.2 135.0 st3 FOYER h 1916 67 47 1.000 6.0 Ox0 VIFx 23.9 115.0 st2 GAME ROOM c 2117 91 92 1.000 7.0 0x0 VIFx 51.2 155.0 st4 GAMEROOM-A c 2117 91 92 1.000 7.0 Ox0 VIFx 44.9 155.0 st4 KITCHEN c 2231 95 97 1.000 7.0 OXO VIFx 8.7 115.0 st1 LIVING ROOM c 2323 53 101 1.000 7.0 Ox 0 VIFX 18.7 115.0 st2 LIVING ROOM -A c 2323 53 101 1.000 7.0 0x 0 VIFx 22.0 115.0 st2 M BATH h 5151 179 72 1.000 6.0 Ox 0 VIFx 50.2 155.0 st6 M TOILET h 1233 43 33 1.000 5.0 Ox 0 VIFx 68.6 155.0 st6 M WIC 1 h 1010 35 13 1.000 4.0 Ox 0 VIFx 43.2 135.0 sty M WIC 2 C 108 4 4 1.000 4.0 0x 0 VIFx 51.0 155.0 st6 MASTER BEDROOM c 2196 88 96 1.000 7.0 Ox 0 VIFx 38.3 135.0 St5 MASTER BEDROOM -A C 2196 88 96 1.000 7.0 Ox 0 VIFx 39.1 135.0 St5 MUD ROOM c 1069 9 46 1.000 6.0 Ox0 VIFx 12.1 115.0 st1 POWDER RM h 2495 87 58 1.000 5.0 Ox 0 VIFx 41.4 135.0 sty wrightsoft- 2019Sep•2410:13:13 ��- ..w•� w.-n, RightSulte® Unlversa1201919.0.06 RSU0B101 i9lA.i\ Page 1 ...nets\Wdghtsoft HVAC\TILLBERG REB-GEM BLDR.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table ' Name Trunk Type Htg (cfm) CIg (cfm) Design FIR Veloc (fpm) Diam (n) H x W (n) Duct Material Trunk st5 PeakAVF 523 371 1.000 958 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 785 679 1.000 999 12.0 0 x 0 VinlFlx st6 Peak AVF 225 109 1.000 646 8.0 0 x 0 WIFlx st5 st4 Peak AVF 317 286 1.000 717 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 544 607 1.000 773 12.0 0 x 0 VinIFIX SO st1 Peak AVF 765 871 1.000 815 14.0 0 x 0 VMIFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1550 1550 0 0 0 0 0x 0 VIFx C * wrightsoft- 2019Sep-2410:13:13 •��••� .•-.-. RlghlSuite® Universal 2019 19.0.08 RSU08101 page 2 ...nets\WrlghtsoR WAC\TILLBERG RES- GEM BLDR.mp Calo=MJ8 Front Dcor faces: N 2017 EPL DISPLAY CARD SCANNED BY l / qlc- 0 S 3O St. Lucie County ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) S. 2778 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.550 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.220 14. Heating system: Capacity 34.0 c) Area 7c. 452.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) go. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *LabelSection R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ome s c mplied with the Florida Building Code, Energy Conservation, through the above energy ich wi installed (or exceeded) in this home before final inspection. therwise, a new EPL e cc I d based on installed code compliant features./ /n Date: y/ Address of New Home: 1313 LONE PINE DRIVE City/FL Zip: FORT PIERCE, FL 11/5/2019 2:26:56 PM EnergyGauge® USA 6.0.04 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1