Quality Steel Corporation AG/UG Propane Tanks
SC BNNED
't• Lucie County
APPROxIMATE AROVEGROUND/UNOEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG`
WIDTH
LEG**
SPACING
WEIGHT
(lbs.)
*`QUANTITY
FULL LOAD
PERSTACK
`120 wg.
24"
Ellin.
5'-8"
3'
1'-11/2"
21-101/2uor 3'-11"
260
108196
16112
*250 wg.
30"
Hemi.
7-10"
3'-8"
1'-5"
4'-11"
480
54
9
*320 wg.
30"
Hemi.
9'-7"
3'-8"
V-5"
5'
620
45
9
500 wg.
371/2"
Hemi.
10'
4'-2"
1'-8"
5'
1 950
37130
8 1 6
1000wg.
41"
Hemi.
16'
4'-5"
1'-8"
10'-1"
1,800
17115
6 1 5
1450wg.
461/2"
Ellip.
17' 4"
4'-11"
1'-9"
11'-7"
2,650
12
4
1990wg.
461/2"
Ellin.
1 23'-11"
1 4'-11"
1'-9"
16'
3,520
8
4
Dimensions and specifications shown are approximate. Individual vessels may vary.
• leg spacing +/-2°. Leg widths and spacing may vary based on mfg. location. Check with your salesperson For detalls. 120, 250, 320 wg. standard tanks
- no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks-2 holes 16" on center. 1450 wg. and up as shown above.
•• Full load and stack quantities vary by shipping location. Check with your salesperson far details.
General Specifications
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1.
Complies with NFPA 58.
- Rated at 250 psig from -20 F to 125" F. All vessels registered with National Board.
-Two service options available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
u
r •.
eri.,ea �
4/ ease •u �...�
'aml Sgu
ONtl1�9N['JN�
,�„ oNaya
N 1.11r r1--,�I'�rR 7/1raa I�IJ�III 11 7i_
• �i 1 �:j�ll _•i
r'ex
r. '1ir`j Ib
-�!!^'..1;( i- niec7►ari,.wi il).111�I •IJI�,^�II;I
'1� wxa'vrWw/ra�atw -111
i
PROPANE CONSTRUCTION NOTES
1. All pipe and fittings above ground and Inside building shall be
SCH..40 Galvanized ASTM A120. or AGA approved corrugated
stainless steel-(C.S.S.T.)-pipe.
2. All polypipe and finings shall be ASTM D251.3 or ASTM D2517
and shall be bt rded-oufside underground at a depth of 18" with
warning tape and tracer wire.
3. All pipe and meter locations are approximate and subject to
change.
.4_ Ali polypipe shall be joined by heat fusion or approved mechanical.
couplings.
5. All -galvanized pipe shall be threaded.
6.' All pipe.shall be pressure tested to.20 PSI -for• a period of 24
hours.
UNDERGROUND TANK INSTALLAilON
,!
2" to G"
DOWNGRADED AWAY
- FROM DOME __ _
,:.
ANODE CABLE �_ ,' •r
SACRIFICIAL ANODE
(MAGNESIUM BAG) %1 �. •�; '
% REGULATOR
SHUT OAS OFF A T
VALVE
•SIDE VALVE
f1 •x
F4U
A90
J-41
Ism—\. o
'
_..
HARR 11G TAPE
RISER.,,
_
1
GRADE/CONCRETE SLEEVE
•.,
� ''a
� .� a::
�• •: .• e• •f - :• o �,
.ail
URUEnanoutloV•OAS
COWAINEneOWAiNEn SERVICE LINE
�0
TRACE HIRE
Bulletin LP-7: R122H
March 2010
Type R122H First -Stage Regulator
Introduction
The Type R122H is an Underwriters Laboratories listed
regulator designed for Two -Stage LP -Gas systems.
The unit is designed to reduce the tank pressure to an
outet pressure of 10 psig. The compact size makes it
ideal for small domestic applications and underground
tanks. The outlet pressure setting isnonadjustable
and is factory set at a nominal 10 psig. Screened drip -
lip vents are oriented over the outlet as standard.
Features
• 20 Year Recommended Replacement Life —The
R122H is designed using rugged time proven
design concepts and constructed of corrosion
resistant materials, both internally and externally.
With proper installation and periodic inspection and
maintenance the R122H regulator will meet a 20
Year Recommended Replacement Life.
• Dual Gauge Taps — Built-in 1/8 inch NPT gauge
taps orificed to a number 54 drill size on both
the inlet and outlet side of the regulator allow for
easy testing.
• Durability — A fluorocarbon valve disc is utilized
to improve lockup performance in systems with
contaminated gas.
• Improved Regulation — A large fabric -reinforced
diaphragm and stabilizer clip deliver accurate and
stable regulation.
• Easy Installation — The units compact size and
easily accessible inlet and outlet wrench flats make
installation easy even in the tightest installations.
FISHER°
Figure 1. Type R122H First -Stage Regulator
Superior Overpressure Protection — The
combination of a high capacity relief valve and large
vent provide overpressure protection that exceeds
UL standards. When used in conjunction with a
R622 or R652, the two -stage system will limit the
downstream'pressure from the second -stage to 2
psig even in a double failure situation.
• Corrosion -Resistant —Added corrosion resistance
from an internal and external coating process for all
castings prior to painting, stainless steel relief valve
spring and retainer and a corrosion resistant relief
valve seat.
• Positive Draining Spring Case — When installed
properly with the spring case vent pointed down,
the design allows moisture formed in the spring
case to drain out limiting the problems with
corrosion and freezing water in the spring case.
a
EMERSON-
Process Management
Bulletin LP-7: R122H
Table 1. Ordering Informolion
TYPE NUMBER
CAPACITY BTUIHR
CONNECTIONS
PROPANE(II
INLET x OUTLET
NOMINAL OUTLET SETTING
R122K-AAA
1 1.100,000
114-inch x lf24nch WIT
10 psig (0,69 Dar)
I. CaPadty is based on 30 PSIG (A,07 Dar) Dtlet We• m and Us &oW.
Figure 2. Type R122H Dimensions INCHES
(MMI
LP -Gas Equipment
Emerson Process Management
Regulator Technologies, Inc.
USA -Headquarters
McW=M Texas 75069-1872 USA
Telephone: ) (800) 5585853
Telephone:) (972) 5483574
For further information visit W ..fisherregulators.mmap
The Emerson logo Is a 11ademark and service Marc of Emerson DeddC Co. M other maths are lire pmperry of their prospect ve ownem. Fisher Is a Mak ovmed by Frgnu CmNole, Inc, a
11USIR 9 of Emerson Process M=wmerd.
The Contents of then puboCooml are presented far mMmaomai proposes WV.. and while every efton has been made M ensure melr a MITeft they are not 10 be construed as vmnan9es ar
guarantees. elmrss orhnpied, rega" Me produds or smvlres deuribed harem or their use or appUcalWey. We reserve me right to readily or mpivm the designs orsperMmllonsof each
wdducts at an mire wimaa more.
Emerson"Cores kvotn�t does not assume MPg ll`y for Coo ealecmn, use a m laaame of all I"060a RssponsibWyfor WWI selecwn, use am malldHtan� of airy Emerson
Rrows+ Managmerd PMduc1 rematts solelywM the Kumaser.
e
EMERSOM
OFmersgn Process Mamgeman Re9mmorTedffWI0 ins, Inc. 2M 2010; All Rights Reserved Process Management
Bulletin 71.1:R622
June 2010
Type R622 Pressure Reducing Regulator
• Comp ,...
• Protei
Scree
• Inlet and Outlet Pressure Gauge Taps
Figure 1. Type R622 Pressure Reducing Regulator
Introduction
Type R622 direct -operated, spring -loaded regulators
provide economical pressure reducing control in
a variety of residential, commercial, and industrial
FISHER'
Relief
leight
applications. These regulators can be used with
natural, manufactured, or propane gases and have the
same inlet and outlet pressure capabilities.
A
d
EMERSON.
Process Management
0
x
0
Bulletin 71.1:R622
Body Size and End Connection Style(1)
1/2 NPT inlet and outlet
Maximum Allowable Inlet Pressure(1)
Operating: 125 psig (8,6 bar)
Emergency: 125 psig (8,6 bar)
Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring
range which has operating and emergency
pressures of 60 psig (4,1 bar)
Maximum Allowable Outlet (Casing) Pressure(l)
Operating to Avoid Internal Part Damage:
3 psid (0,21 bar d) above outlet pressure setting
Emergency: 20 psi (1,4 bar) ,
Outlet Pressure Ranges
See Table 1
Orifice Size
1/8-inch (3,2 mm) orifice
Flow Coefficients
Wide -Open C. for Relief Sizing: 12.5
Wide -Open Cv for Relief Sizing: 0.36
Cl: 35
IEC Sizing Coefficients
XT: 0.78
FG: 0.82
FL: 0.89
Flow Capacities
See Table 2
Pressure Registration
Internal
Relief Performance
See Figure 4
Internal Relief Performance
Start -to -Discharge is 8 to 22-inches w.c.
(20 to 55 mbar) for setpoints from
1.8 to 20-inches w.c. (4 to 50 mbar)
Start -to -Discharge is 140 to 200% over setpoint
from 20-inches w.c. to 2.2 psig (50 to 152 mbar)
Spring Case Vent Connections
314 NPT with removable screen
Temperature Capabilities(1)
-20° to 160OF (-290 to 71 °C)
Approximate Weight
2.35 pounds (1 kg)
Construction Materials
Body, Spring Case, Diaphragm Plate, and
Orifice: Aluminum
Diaphragm, Disk, and 0-ring: Nitrile (NBR)
Adjusting Screw and Pushpost: Delrm15
Closing Cap: ASAThernoplastic (UV -Ray Resistant)
Control Spring: Zinc -plated steel
Machine Screw, Spring Seat,
and Lever: Zinc -plated steel
Valve Stem: Zinc
Relief Valve Spring, Relief Spring Retainer,
Lever Pin, and Vent Screen: Stainless steel
rm wban Should not
In addition, Type R622 regulators have internal relief
across the diaphragm to help minimize overpressure.
Any outlet pressure above the start -to -discharge point
of the non-adjustable relief valve spring moves the
diaphragm off of the relief valve seat, allowing excess
pressure to bleed out through the screened spring
case vent.
Table 1. Outlet Pressure Ranges
Specifications
The Specifications section fists specifications forType R622
Pressure Reducing Regulators. As it originally comes
from the factory, specifications for a given regulator
are stamped on the spring case nameplate.
OUTLET PRESSURE RANGE
CONTROL SPRING PART
NUMBER
CONTROL SPRING
COLOR CODE
SPRING WIRE DIAMETER,
INCHES(mm)
SPRING FREE LENGTH,
INCHES(mm)
1.8 to 224110e WC (410 5 mbar)
T14453TGO12
Purple
0,051 (1,30)
BAG (86,4)
5 to 74nches w tL (12 to 17 mbar)
714398TOO12
Om11ge
0,062 (1,58)
BAG (86A)
6.510941ICh s W.a (16 to 22 mbar)
T14399W012
Yellow
0.067 (1,70)
3.61 (91,7)
9 to 134nCh1 WC (22 to 32 mbar)
T1440CM012
Sllvu
0.072 (1,83)
4.10(104)
13 to 20-lndh s W.C. (32 to 50 mbal)
T14401TOO12
Gray
0,080 (2,03)
3.60 (91,4)
16 to 354nChes W.C. (40 to 87 mbar)
T14402TOO12
Pink
0.093 (236)
3.62 (89,4)
1 to 2.2 psig (69 to 152 mbar)
TI"03TOO12
Light Blue
0.105 (2.67)
3.66 (93,0)
28-Oct-19
Confined Space/Combustion Air Calculation
Address 2613 SE BREVARD
Appliance Btu's Required Required Rooms Rooms sizes in
Air Calc Air in calc Dimmension Calc
Total Room
Air Avail
Cf vol
Range Kitchen 39'x25'x 12' 11,700
No Makeup Air Required for Range '
Laundry 10'x 10'x 12' 1,200
No Makeup Air Required for LAUNDRY
60,000
60,00011000 x50
3,000
Dryer
22,000
22,000/1000 x50
1,100
e
P-0B Pro ane
MaaNrvm Capacity of TracPipe• CounterbUike• CSBT In Thousands of BTU per He
w f
(Basatl on a 7R SpeclB<E:Grevlty 1252g BTU per cable loot Gas)
The higher
g/4'
Maximum Capacity of Tracpipe Counterbtrike CSST In Thousands of BTU per House Propene Gas
dW"IMp
(Baeotl on a 152 9peG6e Gravity 12520 BTU per cable foot Oael
ova mwuue—..-._. ---
the additional length of tubing and n is the number of addilbnai Rungs and/or bends.