Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTIONI St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 SCANNED BY St. Lucie County Mobile Home Inspection Report All requests for permits to place or replace used Mobile! Manufactured homes must be completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner: wmle f3LD& CORP Date: (Print or type) tRGE... 0 Year / Manufacturer RECETVL0 OCT 3 0 2019 sr. Lucie County, Permitting 's AwsH c/xEs FAI RWAY5 IVLttP I FLA5t as83J� HUD Plate #RA J5 A5'0 3 S WidthgZP7 Lengthq1 ISingle Double V111, Wind Zone 3z C = In Compliance N = Not in Compliance Fire Safety / Electrical C 1. Smoke Detector: Installed V : Missing �_ 2. Electrical System Checked: Exposed Wiring _Other 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ C 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 3/9/05 Page t of 3 OCT 3 0 2019 ST. Lucie County, Permitting Construction I. Exit Doors Operable: Front Back Other l� 2. Exit Door Locks: Missing Inoperable 3. Egress windows: Missing Inoperable C4. Windows: Broken Glass Inoperable 5. screens: Missing Damaged_ 6. Floor System: Joist Decking Area Damaged _ 7. Interior Paneling: Missing _ Loose _ Damaged_ 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other C_ 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof —10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NOS[ 12. Walls: Structurally Unsound _ Loose _ Weather tight _ Plumbing —AC--1. Trap: Missing Not connected Other C.2. Plumbing fixtures: Missing _ Not installed _ Not Vented el 3. Relief Valve: Missing Inoperable Other C_4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning _(_ 1. Heating Appliances: Missing Not Connected C 2. Deleted Heating/AC system: Not G 3. Thermostat: Missing Inoperable _Af_ 4. Air registers: Missing Inoperable G 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 C 6. Gas furnace Water heater vent: Missing C 7. Return Air: To Furnace To A/C C 8. Range: Vent Hood Loose From rooms __C, 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary RECEIVED OCT 3 0 2019 ST. Lucie county, Permitting 1. Is subject structure found to be fifty (50%) or more damaged o deteriorated? YES NO_V" 2. Will a remodeling permit be required? YES NO The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: , 13 9 Inspected By: V J CLicense# 3�3j8 �q 7�` sige ure,equiredb75-7�� Phone Number: ( -f "I Engl deal Page 3 of 3 STEpEN G. WOOD, P.E. FL LICENSE W98 95o SULTAN DR pGRT ST LUCIE, FL