Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION4f St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report SCANNED BY St. Lucie County All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: Address Year / h Width 01 & Length&0Single C = In Compliance N = Not in Compliance REf t c- Serial #jX2L!%B27j6ron} HUD Plate Double/ WindZone- Fire Safety / Electrical 6_ 1. Smoke Detector: Installedse� Missing C 2. Electrical System Checked: Exposed Wiring _Other 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other _ 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ 5. Electrical Ground: Chassis Main Panel Gas Pipe Reviwd 319105 Page I of 3 Construction _C I. Exit Doors Operable: Front Back Other C_ 2. Exit Door Locks: Missing Inoperable J�_ 3. Egress windows: Missing Inoperable 6 4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged_ 6. Floor system: Joist Decking Area Damaged 7. Interior Paneling: Missing _ Loose _ Damaged_ Ci 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other 9. Leaks Apparent: Ceiling V Doors _ Floor _ Roof 10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NO_ 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing C 1. Trap: Missing Notconnected Other C 2. Plumbing fixtures: Missing Not installed _ Not Vented 3. Relief Valve: Missing Inoperable Other G 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected C 2. Deleted Heating/AC system: Not installed Other. 3. Thermostat: Missing Inoperable Ci 4. Air registers: Missing Inoperable C 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 G6. Gas furnace Water heater vent: Missing Loose T-Return Air: To Furnace To A/C From rooms 8. Range: Vent Hood 9. Gas Valve: Accessible Installed improperly _ 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or d tenorated? 2. Will a remodeling permit be required? YES NO YES NO_k The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: Inspected By: �,__ Sign urs requlrtM� Phone Number: l,/�J�//;�aj THEIR SEAL. License # 3' 35S Page 3 of 3 Al I9 Engrneers Seal STEVEN G. WOOD, P.E. FL LICENSE 34398 960 SULTAN DR pORT ST LUCIE, FL