Potuct A I M > Product Or nomicgtin s-.-arch > P Ik t lA t > Application Depll
''
FL#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL17443-R1
Revision
2017
Approved
I A TAYLOR ROOFING
302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aol.com
SCANNED
BY
St. Lucie Count
<12
Kyle Taylor �(/�//p I(7�
kylewhite228@aol.com
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Roofing
Metal Roofing
tb odfi Y
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden File
Fdid
Evaluation Report
Copy
Florida License
PE-49704 ----
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
01/23/2023
Validated By
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL17443 R3 COI FL 17443 3 A Taylor 2017 Code Eval R e nnrt with Detail<
=SSa.R4f
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL 1897 2012
ULS80 2006
Equivalence of Product Standards
Certified By
Sections from the Code
IrA
Product Approval Method Method 1 Option D
Date Submitted
01/24/2018
Date Validated
02/14/2018
Date Pending FBC Approval
02/17/2018
Date Approved
04/10/2018
Summar�f of Products
FL A Model Number or Name
Description
17443.1 5 V Com p _._.�
_._.�
26GA i/2' rib hlightt over 15/32 APA plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
EDesign Pressure: +N/A/-129.25
Other.-129.25 @ 6" o.c. -69.25 @16" o.c. margin of.safety
;. 2:1 with24" max, coverage Install per manufacturers detail.
Not, for use in HVHZ.
'Installation Instructions
FL17443 R3 tI FL 17443 1 A Ta/jgr 7017 Code Eval Repots
�
vrth Details R Rdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI AE FL 17443 1 A Taylor ¢37 Code Eval RepRG '
with Details. RSSS P-df
Created by Independent Third Party: Yes
17443.2 VICTORIAN CRIMP SHINGLE
126GA 1/2 RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER I
CDX/APA 15/32" PLYWOOD
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details anti in compliance with FBC 2017 6th
ed. Not for use in HVHZ.
Installation Instructions-����___ ... __.
FLI7443 El I1 EL 17443 1 A Taylor 2017 Code Eva[ Pen: 1
f with Details RK p I
J Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 Ell AE FL 174431 A Tavior 2017 Cade Evai Repork
with Details R599_pdf
Created by Independent Third Party: Yes
n:�<k tii,.]
Conrad Us:: 26M el.+ r String Road T II h R 373" Phone: 850-487-1824
the 5G@ M Florida Is an AA/EEO employer. �,gevfiaht 20n7.2013 grata P fl rid _ Pdvacv Statement :: a� Nbili 5 t t :: Refund Statement
Under Ratios law; email addresses are public records. If you do not want your e-mail address released in response to a publio-records request, pd not serd alechorIc
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any q i,,iburs, please wntmt 850.487.1395. •Pursuant to Section
455.275(1), Randle Statutes, effective October 1, 2012, lichesees licensed under chapter 455, F.S. must provide the Department with an email address if they have
one. The mass provided maybe used for official communlcaUon with the licamee. However email addresses are pudic record. If you do not wish to supply a personal
address, Please provide the Department with an snail address which can be made available W the publw. To determine if you are a leansee Under Chapter 455, ES.,
please dick here.
Product Approval Adcepb:
MROWNERM
Credit Card
Safe
Fort Pierce, FL 34962
(772) 466-4040
Compliant with Florida Building Code 2017 (V1 ed.)
Compliant with Florida Product Approval Rule 0 61620-3
Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY
FBC Sections:1504.3.2. 1507
5V Crimp thru fastened Y"'rlb at each panel edge and 1 fastener In the center of the panel, 24" net cover -age, 26GA ASTM
A79Z 6-50, AZ55, .018, 50ksi min. over min.15/32" thick CDX plywood deck. Corrosion Resistant fastener p9-15 H WH with
sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
of the rib in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. SDx2"-annular ring shank
nails spaced W O.C. reroofing, with less than 19/32' plywood (min.15/32"), this attachment is to be used in addition to
existing attachment. Deck slope 2:12 or greater and shall be cam liant with FBC 2017 61" ad. Undedayment: See FBC 2017 0
ed., Sec 1507 Table 1507.1.1
*'Design Pressure:
Sparing:
-69.25 PSF
16" O.C.
-129.25 PSF
6" O.C.
Corrosion Resistant Fastener #10 x 1" Zinc plated, MM Pancake Head,. installed at Zper panel into lock seam. Panels applied
with 12" exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be
compliant with FBC 2017 6T" ad. Underiaymentl See FBC 2017 6T"ed., Sec.1507 Table 1507.1.1
**Design Pressure:
-105 PSF
W;
Reference Data:
TEST REPORTS
Hurricane Test Laboratory (TST-1527) N0224-0501-06 TAS 125 (UL 580.941)
PRI Construction Materials Technologies (TST-5878) #FAE-023.02-01 UL580-06/UL 1897-04'
I. UL 580-94 teststandords are equivalent to UL 580.06 test standards.
2. UL 1897-04 test standards are equivalent to UL.1897-12 test standards.
u 1. VUndedayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2027 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project speck approval by local authorities w/jurisdiction is allowed by other registered
engineers.
5. Fire classification is not part of this acceptance. Sheardiaphragm values are outside this report.
6. Support framing in compliance w/FBC20176'h ed, Chapter 22Steel,Chapter23Wood andChapter16Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturin�?(,JJJ;VPuting products
under this evaluation. ttt gOW( }rrryrrr/
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or, � i ■ this
report. �.`(�E��E`4
r.
5 V Crimp
Fastener- #9-15 corrosion resistant w/sealing washers
24" coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening 1 2"o.c.
Panel Width: 26"
Panel Coverage: 24",maximum
26 GA Architectural Metal Roof panel
VICTORIAN CRIMP
MINIMUM 2 FASTENERS
AT LOCK SEAM
FIELD CUT 112 SHINGLE
TO CREATE STAGGERED
PATTERN
VICTORIAN CRIMP
SHINGLES
9"EXPOSURE
w
of
D
w
O
a
x
w
N
Fastener.410x 1"
Zinc Plated MTW
Pancake Head
A SCANNED
BY
e a St. Lucie County
MUM
_..
- a 5 Home lug in j User Registratlpn Hot Topics j S.bmit surNarge ! stats ll Facts I Publi.o ns I F5C Roo MS Site Map ! links i Seamn
p
v product Approval
USER: publk User
1 2
Pnotlutt Approval Mrny> PrMuct or Ae_ nu ,,tjnn S 'Ch > Application List > Appilcadon Detail
PL 9
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technicai Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL9777-Rll
Revision
2017
Approved
Owens Corning
One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg. keeler@owenscoming.mm
Greg Keeler
greg. keeler@owensmming.mm
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Roofing
Undedayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
-d Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest Mile Copy
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke. Bowden
Certificate of Independence
'~ Validation Checklist - Hardcopy Received
EL9777 RII COI OCRI4002.8a 2017 FBC Evilyptign Report W ath rlo k
Nan-HVHZ.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
TAS 103
1995
UL 1097
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2017
Date Validated 10/11/2017
Date. Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summany of Products
FL #
Model, Number or Name
Description
9777.1
Weathedock G
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions
FL9777 Fill II OCR14002 8a 2017 FBC Evaluation Report
Weathedock Non-HVHZ odf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14 02 2p ent7 FBC Evaluation geport
Weath do k Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.2 WeatherLock G (High Tear)
Weatherproofing Undedayment
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
EL9777 RIl II OCR14002 8a 2017 FOC Evaluation Reno
Weathedock Non-HVHZ.Ddf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 RI1 AE OCR140D2 ea 2017 FBC Evaluation Report
Weatherlock Non-HVHZ odf
Created by Independent Third Party: Yes
-
9777.3
Weatherlock MAT
Waterproofing Undedayment
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: No
Installation Instructions
EL9777 RIl II OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZodf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
'
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 R11 AE OCRI4002 eb 2017 FBC Evaluation Report
Weatherlock HVHZodf
Created by Independent Third Party: Yes
9777.4
Weatherlock MAT
Waterproofing Undedayment
Limits of Use
Approved for use In HVHZ: No
Installation Instructions
EL9777 R11 1I OCR14002 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Weatherlock Non-HVHZ.odf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL 9777 Rll AE OCR140Q2 8a 2917 F13C Evaluation Report
Weatherlock Non-HVHZ
odf
Created by Independent Third Party: Yes
9777.S
Weatherlock Metal
Weatherproofing Underfayment
Limits of Use
Approved for use in HVHZ: No
i Approved for use outside HVHZ: Yes
I Impact Resistant: N/A
Design Pressure: NIA
Other: See evaluation report for limits of use.
Installation Instructions
F19777 R11 11 OCRI40028a u17 EB9 Evaluation a rr
Weatherlock Nan-HVHZ odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 Rll AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ odf
Created by Independent Third Party: Yes
19777.6
Weatherlock Metal
Weatherproofing Undedayment
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: No
Installation Instructions
FL9777 RI1 II OCRI4002 8b 2017 FeEvaluation R ¢4Lt
Weatherlock HVHZodf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.7 1 WeatherLock Specialty Tile & Metal
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R1I AE OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.odf
Created by Independent Third Party: Yes
Underlayment
Installation Instructions
FL9777 R11 II OCR14002.8a_2017 FBC. Evaluation Report
uparnenocK Non-nvnc Dor
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
Party: Yes
Back eezt
Contact( :: 2601 BI 1 SO B d T p h = 32 90 phone BW-487-1B2M1
The state of Florida It an AAAEO employer. Coovdoht 2007.2013 State of Florida_ :: Cdvacv SMameM :: Aceeselblllty Statement :: Refund Statemme
Under Flodde law, email addresses are public records. If you do not want your e-mail address released In meponsa to a publle-recoms reason, do not send electmNc
mall to this entity. instead, Contact the office by phone or by traditional Mal. If you have any questions, please Contact 850.487.1395. `Pursuant to section
455.275(1),. Florida Statutes, effective Odbber 1, 2012, licensees licensed under Chapter 455, F.S, must provide the Department with an email address if they have
one. The emaiis provided may be used for official communication with the licensee.. However email addresses are public record. If you de, not wish to supply a personal
address, please provide the Deparbment with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please dick hem .
Product Approval Accepts;
®OW R
�CC111`l i'\"it }"1°Rt Cs'
$` R CREEK Certificate of Authorization Eon bur 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6' EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
(800)438-7465
www.owenscorning com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underiayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Enti
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies ((ST5878)
NEI-053.02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093.02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-213.02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OGF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272.02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296.02-02
ICC-ES AC 188'
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
ICC-ES AC 48
ASTM D 1970
2012
2015
PRI Construction Materials Technologies (TST5878)
OCF318-02.01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Matedais Technologies (TST5878)
OCF-355.02.01
UL 1897
2012
'Detennined to be equivalent to ASTM D 226-09, Type I
and 11
OCRI4002.8a FL9777-Rll Page 1 of
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
R E K OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock(D Self -Sealing Ice & Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive undedayment constructed from SBS
(Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq, rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
Weathert-ock@ Mat
WeatherLock@ Mat is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH or
Houston, 7X)
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-11 and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@
WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, 7X)
Weathert-ock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. Wealherl-ock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete the roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND Roof Tile Adhesive. (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof • slopeshall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock@ G (High
WeatherLock@ G (High Tear) is a self -adhered, undedayment used as an alternative to
Tear)
ASTM D 226, Type I or Type I I roofing felt and ASTM D 1970 self -adhering polymer
(Houston, 7XJ
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-11.
Weathert-ock@ G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
FL9777-RN
2 of
• ••----•���� �w.., L ,� v.�.mca jUj Qww ui nonoa proouct approval under Rule 51020-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply Warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All underiayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underayment
application. Prior to beginning Installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlaymeht shall be installed with the release backer removed and pressed firmly
Into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum,3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Speclalty Tile & Metal, end laps shall be premed with ASTM D
41 primer or seated with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Undedayment System No.1 — WeatherLeek_Specialty Tile & Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
undedayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
FL9777-R11
3 of
...,,..,.w�
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attdbutes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck. area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The undedayment may be used as described in other current FBC.. product approval documents.
6) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code e Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
E NrtpR�tt
No 74021
%13 STATE OF
CERTIFICATION OF INDEPENDENCE
2017.10.
_ Ile 09:06:29
.�. 04r00t
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products
under this. evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
4 of
I his evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whichthisreport is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.