FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT S(
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIIEER_CE , FL ,
Permit Number:
St.
Owner: J Q S'l�.a.�.�...Q-
Jurisdiction:
Lt.
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft-
b. Frame - Wood, Adjacent
R=11.0 192.00 ft-
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1474.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft'
6. Conditioned floor area above grade (ft') 1474
b. N/A
R= ft°
Conditioned floor area below grade (ft� 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor. Sgl, U=1.04 101.25 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=6.0 1473.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.03
PASS
Total Baseline
Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
SHE STgrA
this calculation are in compliance with the Florida Energy
specifications covered by this
OF
Code.
calculation indicates compliance
with the Florida Energy Code.
f+ nar,�Y:, ,';' '•°;`°, �O
PREP ER-� Y:
Before construction is completed
DATE l ►
this building will be inspected for
compliance with Section 553.908
0 $ Y
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
p WE 1 R�
Hef''
OWNEf�(AGEp(T.
BUILDING OFFICIAL:
DATE: �11\ �� ti
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with F 4 FF,4Ah%iW&-QrHj&1 uires an
envelope leakage test reportwith envelope leakage no greater than 7.00 ACH50 (R402.4.1d'ODE COa" PLIANCE
��ST. LUCIE COUNTY
BOCC
9/11/2019 12:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1474
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1535 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0
329 ft-
___
0 1
0
2SIab-On-Grade Edge Insulatio WIC t ft 0
63 ft-
-_
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH Sit 0
56 ft'
—
0 1
0
4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
___
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft-
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0
203.5 ft'
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
0 1
0
9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft'
___
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft'
_-
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1553 ft'
246 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
160
1474 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Woad
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft'
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Ext IndilEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
8 S=>N Exterior Concrete Block - Ext IndBffDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Ext IndiEDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Ext In50REAT/DINI
4.1 26
0 8
0
208.0 ft'
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Ext In50REAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft'
0.23
0.4
0
9/11/2019 12:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Omt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/ Wall
V # Omt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in
1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in
1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in
1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in
1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapesiblinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft'
315 ft'
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgIA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
/ — Supply —
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 275 ft'
Attic
65 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programabl[e
Cffeiling Fans:
Jan Feb
Heat ng tX] Jan Feb
Mar
AApr
May
[[{ ]]
Jun
fX�
[ ] Jul
DC�
[ ] Aug
[ j
Sep
(] ([)C�)
L J Octct
Venting II ]) Jan I 1 Feb
L l
X Mar
[
[ Jun
lXl
[) Jul
[ ) Aug
EX]
) Sep
lxJ [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (VVEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft'
It
0.3
KITCHEN
Default(8 lbs/sq.ft.
ftR'
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default 81bs/s .ft.
ft2
ft
0.3
GREAT/DINING
9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ed ceiling/soffit
y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation,
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nipino and wirina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electdcal/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log we shall be in accordance with the provisions of ICC-400.
•9/1112019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply duds R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unitIPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-fador:(weighted average)
Be.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: \' d \ `5
r
Address of New Home: THE STERLING City/FL Zip: FT. PIERCE. FL
9/11/2019 12:29:27 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsoft-
Project Summary
Entire House
QUICK CALCS; INC.
SCANNED
BY Job:
St. Lucie County ar
For. W`(NNEDEVELOPMENT
(nT�HE STERLING, FT. PIERCE, FL
k
Notes: ` '� Ct
Weather. Fort Pierce, FL, US
Winter Design Conditions _
Summer Design Conditions
Outsidedb 42 OF
Outsidedb
90
OF
Inside db 70 _ OF
inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Dailyrange
L
;
Relative humidity
50
%
Moisture difference
61
gr4b
Heating Summary
Sensible Cooling Equipment Load Sizing.
Structure 18188 Btuh
Structure
17877
Btuh
Ducts. 5654 Btuh
Ducts
8536
Btuh
Central vent (0 din) 0 Btuh
Central vent (0 cfin)
0
Btuh
none
a)
Humidifica) Lion 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipmentload 23842 Btuh
Use manufacturer's data
n
Ratetswing multiplier
0.95
Infiltration
Equipmerltsensbleload,
25093
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0
Structure
2958
Btuh
Ducts .
2319
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg cool'
Area(M
(none).
1474 147%
Equipment latent load
5277
Btuh
Molume(f[3) 12227 12227
Airchan esmour 0.45 0.23
Equiv. Ag 92
Equipment Total Load (Sen+Lat)
30370
Btuh
(dm) - 47
Req. total capacity at 0.70 SHR
3.0
ton
Heating Equipment Summary
Cooling. Equipment Summary
Make Carrier
Make Carrier
Trade CARRIERAIR CONDITIONING
Trade CARRIERAIR CONDITIONING
Model_ 25HBC536A"030,
Cond 25HBC536XO30
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref 791458t
Efficiency 8.5 HSPF
Efficiency 12.0 EER,15
SEER
Heating input
Sensible cooling
24360-
Bt1h
Heating output 34600,; Btuh @ 47°F
Latentcooling
10440
Btuh
Temperature rise 127 OF
Total cooling
34800'
Btuh
Actual airflow . 1160 cfin
Actual airflow
1160
cfm
Airflowfactor 0.049 dml tuh
Airflowfactcr.
0.044
cfiTilBtuh
Static pressure 0.50 in H2O
Staticpressufe
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.83
Capacity balance point = 33 OF
Backup:
Input=7kW, Output= 23009 Btuh, 100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
?F Wr htoOft" 2019Sep-170931:10
.ma.-, pe..6 P , PJgtt SLite*Lkiwrsal20l9l9.O.O7RSU08101 'Page
�a rds\WdgtboftWAC\WYNNE-TFESTERLWGjw Cale-MJB FraitDoorfaee&N
wrightsoft- Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. a,.:
317 ST. LUCIE UN, Fr. PIERCE, FL 34946 Phow:772-466-6799 Fax772-466-6796 Emil: QUICKCALCS@AOLCOM
I
Roomn
Ertre Home
MkSTER BEDROOM
2
Elpomdvdi
1562 it
520 It
3
R= height
8.3 It d
8.0 it heeti=l
4
Room dimmsiom
1.0 x 329.0 It
5
Room area
1473.5 IF
329.0 W
Ty
Construction
U-%olue
Or
HTM
Area W)
Load
Area (Il)
Load
number
(Btuhfi*
or perimeter (to
(Btuh)
a perimeter (fl)
(BLh)
IHeat
Cad
Groie,
NPIS
1�
Heat
Heat
Cool
6T'
I-�
0143
.
479
'442
1
1768
1Cool
. 1124
,2
1Gross
80
1NIPIS
80
,i
-G
"
. I 1270
38_"'o
---1344
vwwm
12tu
w
as.6ti
34.[/
24
24
so
829
0
0
0
0
0.390
m
10.92
1131
22
22
236
244
0
0
0
0
A3A:406'
0143
T'S'
Im
----400
2 55
"•34
34-
138,
-,,,88
0
--'0
�0
O
WL.G
13AA=
1A-dom
0.143
10
2M
360
353
1414
899
224
224
897
570
712c-ow
1270
w
35.56
42.91
7
5
247
298
0
0
0
0
34A
255
-10
-,217
867
:.'551
-1�112
"79
"318
202
�JX.cicim
270
1AM 1
-
0
f 1$80 162
1478
33
0
1162
"
Z' "-1478
M
2146
ZT.54
41
"o
C'
1124
0
1
0.091
2.55
128
192
192
489
246
0
0
0
0
C:
0.032
A.90
•—232
1474
1474
4320
3419
329
9
F
22A-V
0989
2759
0.01)
14TI
4325
0
329
52
1440
f763
0
11156
q
6.
0) AED womirsim
764
680
Envel6pelos4gain
15366
13954
443 1 2
3897
12
a) Infiltrator
2822
773
909
249
b) Roomwrilllaton
0
0
0
0
13
Intorrtalgaim O—Pmts@ 230
5
liso
2
460
Applianceskiftr
2000
0
Sublntaloines6tolq)
18188
17877
5341
4606
Lesscolemalload
0
0
Le nnsrer
0
0
Redislitbifion
0
0
14
Subtotal
18188
17877
15 1
DUCtloadS
31%
48%,
5654
8538
31%
48-A
Total room load
23842
26413
Airreciured(oinn)
1160
1160
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2019-Sep-170931:11
PjgWStite@Lhiwrsal20l9l9.0.07RSLICS101 Page 1
.Xemerds\WdgltsaWAMVVYNNE-THESTERLINGnp Ca1c=MJS FicirtDoortiecox1f]
I
wrightsoft RighW@ Worksheet Job:
Entire Hbuse Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LK, Fr. PIERCE, FL 34946 Phom:772466-6799 Fax77246"796 Emil: QUICKCALGSC&AOL.COM
1
Roornrourre
WIC
?A BATH
2
EVDSDd VDII
0 It
&0 It
3
Room height
8.0 ft hwtf=l
8.0 It heatbool
4
Roamcrimmsions
7.0 x 9.0 It
7.0 x 8.0 It
5
Roommea
63.0 W
56D IF
Ty
Constriction
U-value
or
HTM
Area
Load
Area M
Loadnumber
(3tUhfifL'q
(Buhffl
or perme
MIA
or perinea (IQ
(Stuh)
Heat
I Cod
Gross
NIPS
Heat
Cool
Gross
I NIPS
Heat
Cool
6
L L
0f143
tA.60
��z,✓-2_M
6
6
0
0
'_qo
'0
6
0
_x6lorn
_'�"1270
TW,
�70 43
0
0
O'_
0,
0
.10
w
1aA4ocs
0.143
se
4.00
2�i
0
0
0
0
0
0
- �o
0
0
IA-clorn
1270
se
35.58
34.77
0
0
0
0
0
0
0
0
11
11DO
0.390
as
10.92
11.31
0
0
0
0
0
0
0
0
.
am
' -!s.
0-
:'0
o
0
0
--i� �O
w
L—G
13A-40M
1A-clorn
0.143
sw
4.00
2M
- 0
0
0
64
57
' 228
145
1270
SN
35.56
42.91
0
0
0
0
7
5
2,47
298
k'043
4:00
';E55
'425
�0.
0'
_-O
0
1270
24
0
0
0
0
2156
7.54
-0
a
P
12C-Osyy
0.091
155
128
0
0
0
0
0
0
0
0
..032
0.96
t2
_32
83
Z' "63
56
0
:ZV 130
F
R-989
2749
0.00
63
0
0
0
5's
0
7
%
'7
6
C)AEDexcursion
1
-2
..225
Envetopelossigain
56
145
747
798
12
a) Witration
0
0
140
38
b) Roorovenlitalion
0
0
0
0
13
Internal gains Cowpants@ 230
a
0
0
0
Appriancesvother
0
0
Subtotal Ones 6 to 13)
58
145
887
AIR
I-Essexternal load
0
0
0
0
Lesstransfer
0
0
Redistri1xilion
a
0
0
14
Subbotal
56
1 45
a 87
15,
Ductl 1
31%l
48-1.1
18
69
31%1
48%1
276
A
Total room load
74
214
162
Airreclured(olm)
4
9
57
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
A
RO&SUteSUriversal 201919.0.07 RSLJO81 01 d& L ties- 2019-Sep-1709:31:11
-0�MNWnghtwftHVAC�VVYNNE—THESTERUNGitp Calc=W8 FrortDoorfacev. N Paget
wrightsoft• Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN, Fr. PIERCE. FL 34946 Prore:772-466-6799Fac772-4666796 Email: QUICKCALCS@AOLCOM
1
Room name
KITCHEN
BATH
2
FVosedmell
0 ft
5.0
5.0 It3
Room height
8.0 Ithew/000l
8.0 It
4
Roomdimmsions
1.0 x 1920 It
9.0
x 5.0 -ft
5
Room area
1920 IF
45.0 R2
" Ty
Construction
U-value
Or
HTM
Area (et
Area (ip)
Load
number
(eNFNIz`r7
(Btuh4h')
ar perimRx (t)
(LoadBuh
Btuh)
or perimels (iq
(BWh)
Heat
Cad
Gross
NrP/S
Heat
Cool
Gmss
NOS
Heat
Cool
8
13A-0cos, .
"0143
ne
-: 400
255
0
`; 0
' 0
40
'r 40.
+:= 160
`^102
1A-dom ,.. . -
, " 1270
'0
„'-0'
.'.. -,_ !0
. 0
o
,,,.. 0
'; , '..; 0
11 W 13A�as . 1i0 � s,�..'-ra4.w �;" 59 - O�s. ?:' 0�. ^-.. 0
00
11 31 0
- 0770
,'hd,
c'�:21.56
:`�:-WM0.„
D;:.
p
(
,,?0
-12C-0sv
0091
255
128
64
64
,':
,0
163
82
0
-
dfiASOmd. ,tt.
t•x4)032
_
.:-pgp
_�?2�32
..192
,� -
192
"_45'�
;_-
,,,
?2h411
.. .,0989
�_ _
,2769
0.00
192
0
_;',-r...172:4p5
0
0
45-
Fmelope los4gain
&MI
501
339
204
12
a) Infiftfim
0
0
87
24
b) Rcomlentilaton
0
0
0
0
13
Udend gains: C—pants@ 230
0
0
0
0
Applimoesrafier
2000
0
Subbial(Gnes6to 13)
335
2501
426
228
LesseAunal low
0
0
0
0
Lesstrandar
0
0
0
0
RedistribLdon
0
0
0
0
14
Subtolel
335
2101
426
228
15
Dudloads
31W.
4RY
iml
11.4
31%
a w
1n1
1n0
39
21
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
�. Ad- wrtrati owT!^ 2019Sep-1709:31:11
PogMSUteOlAmrsal 201919.0.07RSW8101 Page3
.-oamerdslWriglt oftHVADWYNNE-THESTERUNGnp Calc=MJS Frort Doorlaces N
wrightsoft- Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317ST.LUCIELN.,Fr.PIERCE,FL34946Phona:772-466-6799Fa 772-46"796 Email: QUiCKCALCS@AOLCOM
1
2
3
4
5
Roomname
.B"Sedvall
Roam height
Raom dimensions
Roomarea
BEDROOM2
322 it
8.0 ft heatimol
1.0 x 203.5 ft
203.5 ft'
ENTRY -
7.0 It
8.0 ft heaVmol
1.0 x 55.0 ft
55.0 ft°
Ty
Construction
number
U-value
(BWhRtz°f7
-Or
HTM
(BluhMtj
Area (fFj
of perimeter (Iq
Load
(Bhih)
Area (ft')
a perimeter (to
Load
(BWh)
Heat
Cad
Gross
N/P/S
Heat
Cool
Gross
NrP1S
Heat,
Cool
6
lyV . i .
;-03A-0op ..-1, ,
'°. ', ,:: 0.143
'.re
- _ ^4.00
= 'i2S5
. {128
:'. - 12B
f. - 513
..`ixt
.. . ,`.tn
. n
i,., r{ , n
.... -;'6
se
Se
.341 341 -- 1361 }� - -:861 ; :. 01'_ _ ..
077p
. rnv,' '`
`2156 ,
2754
0
+
0
- 0
-:V
`i0
U
"0
`.
u
'
:: U
-
-«ap
" 0
P -
12COw,
0091
255
,
128
0
0
0
0
.,
72
0 —,r
72
o
183
,.
`!
92
C^-^0032
. - • '
:,._ 0.9 "
r2:32
204
"[°
204
;' `182
ia.472
_55
55
49
r'°128
F -y.
Z2A-QII _.,
0989
-
27.69
0.00
204
32
° 891
0
55
7
194
-
0
8
�AED elmuaon
-24
S
Ernelopefosdgain
_
2W9
1873
BOp
545
12
a) Nfiltrafion
564
154
122
34
b) Rmm�enfilation -
0
0
_
'0
0
13
inhxnal wins
Omlpartls@
230
t
23l]
0
0
Lesse#emal load
Lesstransfer
Redistributlon
14 . Subtrrtal
15 Dudloads
Calculabons approved byACCAto meet all requirements of Manual J 8th Ed.
mna ft!¢e - 2019-Sep-770911:11
RigtiSute9Uimrwl201919AA7RSW6101 Page4
.-?amedh1WrigWmftWACiWYNf�-THE STERLWGnp CaIc=MJB FroA Daorfaces: N
wrightsofe Right-JO Worksheet Job:
Entire House Data.
QUICK CALCS, INC. BY.
317 SL LUGE LN..Fr.PIERCE, FL 34946 Ptnre: 772466-6799F=77246F6796 Emil: OUICKCALCS(LDAOLCOM
1-
2
3
4
5
Room name
I5VOsed'4ell
ROom height
Roamdimmensions
Roomaiea
LAUNDRY
6.0 It
8.0 it heat =I
7.0 x 8.0 A
420 IF
GREATIDINING
46.0 ft
82 ft heathmi
1.0 x 488.0 It
488.0 iF
ry
I Conshdon
number
U- Iue
(BWhAtL9
Or
HTM
(BUhAF)
Area
or perimew (tq
Load
(BWh).
Asea.(F
as padmeter (f)
. Load
I.
Heat
I Cool
Gnus
N/Pis
Heat
I Cool
Gross
I NIPS
Heat
I Cool
11 I VI 110 I 0290 Be
OI w
13
Miami Oo Wyft@ 230
0
0
2
460
AppGanoeshlher
0
-
1
0
Subtohl Qines6fa13)
644
317
-'6154
6409
Lessexameiload
0
0'
- 0
- 0
Lesstansfer
0
0
-
0
0
RerLsb'bulim
0
0
0
0
14
Subbial
644
317
6154
6409
15
Ductloads
31%
401/0
200
151
31%
481%
1913
3060
Totaf iwm load
644
468
8067
' 9469
Air regrured(cfm)
1
41
21
393
- 416
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed.
2019Sep470991:11'
RigNSuteOLhmrSM201919.0.07RSW8101 Page
._aamenls\Wiig*zRWAC\VYYME-THESTERUNGnp Cale=MJB Fmnl Doorfaces:N _
t
w►rightsoftm Duct System Summary b:
Entire House By,
QUICK CALCS, INC.
317 ST.LUCIE M Fr. PIERCE, FL 34946 PInre:772-46SV99 Fa 7724666796.Email:QUICKCALCS@AOLCOM
For. WYNNE DEVELOPMENT
THE STERLING, FT. PIERCE, FL
Heating
Cooling
Extemal static pressure
0.50
in H2O
0.50 in H2O
Pressurelosses .
0
in H2O'
.0 in H2O
Available.static pressure
0.50
in H2O
0.56 in H2O
Supply / return available pressure
0.250 / 0.250
in H2O .
0.250 / 0.250 in H2O
Lowestfriction rate
0.284
in/100ft
0.284 in/100ft
Actual airflow
1160
cfm
1160 cTm
Total elective length{TEL)
176 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(dm)
Design
FR
Diam
(In)
HxW
(In)
Duct
Mat
Actual
Ln (A)
Ftg.Egv
Ln (ft)
Trunk
a`TM
h 559
27
15
0.376
4.0
Ox0
VIFx
18.1
115.0
st1
BEDROOM2
h 4486
218
146
0.374
6.0
OxO
VIFx
18.6
'115.0
st1
ENTRY •
h 1209
59
38
0.510
4.0
OxO
VIFx
3.0
95.0
GREAT/DIMNG
c 4735
196
208
0.318
7.0
OxO
VIFx
22.4
135.0
st2
GREATUNNG-B
o 4735
.196
208
0.307
7.0
0x0
VIFx
28.1
135.0
st2
KITCHEN
c 3695
21
162
0.375
7.0
0x0
VIFx
18.3
115.0 1
st1
LAUNDRY
h 844
41
21
0.366
6.0
Ox0
VIFx
21.6
115.0
st1
M.BATH
h 1162
57
54
0.366
4.0
OxO
VIFx
21.6
-115.0'
st1
MASTERBEDR00M.A.
h 3501
170
149
0.297
6.0
0x0
VIFx
33.1
135.0
s12
MASTERBEDROOwB
h 3501
170
149
0.284
6.0
OxO
VIFx
41.1
135.0
st2
WIC
c 214
4
9
0.310
4.0
OxO
VIFx
26.3
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Dud
Name
Type
(cfin)
(dn)
FR
(fpm)
(In)
(In)
Material.
Trunk
st2 , .
PeakAVF
737
724
0.284
938
12.0
0 x 0
VinlFlx
st1
st1
PeakAVF
1101
1122
0.284
1050
14.0
0 x 0
VinlFlx
wrightsof - 2019-seo-1709a1;11
•wri. w-,..�. Ri9K'Sule&LhWr5a1201919.0.07RSU09101 Pagel
...o rbkVifigWioftWAC\WttJNETFFSTERLNGjW Uc=WB Imri DoorMw%N
Name
Grille
Size (in)
Hlg
(dm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(n)
H x W
(in)
Stud/Joist
Opening (in)
Dud
Matl
Trunk
rbl
Ox0
1160
1160
0
0
0
0
Ox 0
MFx
C # wrigghtso t- 2019-Sep-170991:11
�.r FU9h uteGLhwrsal 201919.0.07 RSLJO8101 Page2
...o rbUdgNsoftWAMWVNNE-THESTERL[NGnp Cala=MJ8 Front Daorfaw& N