Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE T GRAND CARLTON I ACT Street: �j'�q-� 2,10 Builder Name: WYNNE BUILDING COPR. SCANNED Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: BY Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade (ft') 1446 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=1.04 101.25 ft' SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1445.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 16. Credits Patel Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.31 PASS Total Baseline Loads: 48.06 1 hereby certify that the plans and specifications covered by Review of the plans and Srg2, this calculation are in compliance with the Florida Energy specifications covered by this 0�41HE a O� Code. calculation indicates compliance y'r i„°"� =3,,, O with the Florida Energy Code. rarr°. 4sf : ;;••• r O PREP Ep �/ Before construction is completed r d DATE: this building will be inspected for compliance with Section 553.908 rt O I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'0 WE OWNER/A DIT:t BUILDING OFFICIAL: OO dd DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. ,n�,I�� - Compliance requires an Air Barrier and Insulation Inspection Checklist in ac CItatanTl this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACM �1Y2) PLIANCE CODE &A ST. LUCIE COUN I Y BOCC 9/13/2019 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 -_ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 f12 ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---_ 0 1 0 9/13/2019 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FOAM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' ___ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' __ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft' 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Ext Ins@EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Ext Infi&DROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext ImHEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Ext InsOREAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Ext InsOREAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 9/13/2019 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 24.0 ft- 6 It 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfrn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SeWnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 9/13/2019 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS -- Supply — -- Return— Air CFM 25 CFM25 HVAC # J # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e C[ei]ling Fans: jThermosta[[t:]]Y Heating (X) Jan H Feb Mar [ [ ] ] Apr [ ] [` ]] lX1 Jun [[` ]]] ri Jul fX] [ ] Aug [[ ]] IXJ Sep (] [rX,] L Oct NovrX,] Nov Dec [ Dec Venting II 11 Jan II II Feb X Mar [Xl (1 May lll[ 11 Jun [ 1 Jul [ ] Aug [( 11 Sep lxl [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 SO 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' It 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. fP It 0.3 BATH Default(8 lbs/sq.ft. ft' It 0.3 BEDROOM 2 Default(81bs/sq.ft. ft' ft 0.3 ENTRY Default(81ba/sq.ft. ft' ft 0.3 LAUNDRY Default B lbs/sq.ft. ft' It 0.3 GREAT/DINING 9113/2019 1:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 P shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninqno and Wrina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids cover plates and I ceillno -a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 9/13/2019 1:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec°/a B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. \\ Builder Signature: Date: Address of New Home: J\-) 7�t \`-UlLo �1 1� City/FLZip: FT. PIERCE. FL 9/13/2019 1:21:48 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project SummaryJob: - wrightsofE° Entire House BDa yte:: QUICK CALCS, INC. For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL SCANNED Notes: <%7- BY St. Lucie County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions. Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (O'cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Ratelsnrinp multiplier Equipmenload 0.95 24753 Infiltration sensible Btuh Method Simplified Latent Cooling Equipment.Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0' Btuh Heatingg Cool T% (none) Area (ft�) 1446 Equipment latent load 5521 Btuh Volume (ftj 12511 12511 Air changesthour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment S ummary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536A•030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI'ref 79145 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Stuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling . 34800 Btuh Actual airflow 1160 cfm Actual.airflow 1160. cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Apr-11 09:29:36 Right-SuiteO Universal 201717.0.14 RSU08101 Page 1 ...uick Ca1cs1Doc=ents1TFE GRAND CARLTON-1446.mp Cab = MJ8 Front Door races: N wrightsoft Right4@ Worksheet Job: Entire House Dace: QUICK CALCS, INC. By. 317 ST. LUCIE 1A. FT. PIERCE. FL 34946 Phone: 7724666799 Fax 772-466.6796 Email: OUICKCALCS@AOLCOM 1 Room name FsUre House BEDROOM 156.2 ft 49.0 ft 3 Rcpome hill 9 8.7 ft d 8.0 It heaU000l 4 Room dimensions 1.0 x 297.0 It 5 Room area 1445.5 ft' 297.0 fto Ty Constiuctian U-value �Or HTM Area (ft� Load Area (ftq Load number (Btutvfti°� (BtulYft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross WP/S Heat Cool Gross WP(S. Heat Cool 6 14A5-tom- 13A4ocs, . -.0143 -;. n ,4.00 - - 255 503 465 • L•, IBM • 1184 72 170 2 0.770 _. n'. 21.56. ' 19.31 . -..38 ,.. 0 • ' 815 ,: 730 0 : 0 - 0 13A4ccs 0.143 a 4,00 255 128 83 333 212 0 0 0 0 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - '13A4ocs 0.143 se 4.00 2.65 34 - 34 136 86 0 ` 0 0 0 y/ 13A4ocs 0.143 s 4.00 2.55 360 353 1414 - 899 216 216 865 550 L—f 1Ac1om 1270 s 3556 34.77 7 7 247 241 0 0 0 0 :13A4ocs ..0143 w . 400 255 310 237 949 603 104 72 - 288 483 1Aclom -4 270 w ...3556 ,6521 �32 4 2 '- - 1140 . 1770 = 32 "2 ';, 1140 `•1770. 05-2om; _-:0.770 w ." 21.56. :. ;19:31 41 ,. 41 '.. 880..-. 788 0 .p •_. 0 , -'.::.0 P 12COsw 0.091 - 255 1.28 192 192 489 246 0 0 0 0 C . ^t IISA30md - '0.032 - ' .•0.90 _ 232 -.. 1446 . ,.1446 1296 - ' 3354 297, 297: '266 :. - - 669 F 22A-tpl 0.989 - 27.69 . 0.00 1446 156 4325 0 297 49 1357 0 6 c)AFD excursion 918 627 Envelope loss/gain 14961 13349 4204 4DD3 12 a) Infiltration 2887 791 848 232 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal Qlnes 6 to 13) 17848 17520 5053 4925 emal load 00 0 0sfer000 0 ution 000 0 ED 1799 -17520 5053 4925 ds32°k 49% 8536 32% 49% 1601 2400 m load 23%3 . 26M6653 7325ed (cfm) 1160 - 1160 328 326 .4e& -FIf- wriightsoft- RightSulteO Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale =MJS Front Door faces: N 2017-Apr-11 09:29:38 Page 1 wrilgRsofC RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE I-M. FT. PIERCE. FL 34946 Phone: 772-466-6799 Fas 772466-6796 Emil: OUICKCALCS@AOLCOM 1 Roomname WIC KITCHEN mad Oft Oft 3 R height eight 8.0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 1720 ft 5 Room area 54.0 fl' 1720 ft- Ty construction U-value Or HTM Area (ftj Load Area (fll Load number (SlulJftz*F) (Rlu1/111 or penmeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross I WP/S Heat Cool Gross I WP/S Heal Cool 6 WVy 13AAccs `- :.4A54orn'., - '0:143 n' 4.0q : 2.55 0 ,.0: 0 0 0: . '0' .o " 0 LG' .. 0.770 n' `-' 21.56 ' 19.31 ' ' 0 " ' 0 - 0 .. ".o 0 0 ::- "0 �' - .: 0 4�1�C 13AAccs 0.143 a 4.00 255 0 0 0 0 0 .. 0 0 0 `D 1Actom 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 :W - 13AAccs 0.143 se 4.00 265 0 0. 0 0 0 0 ,0 0 W 13A-0acs 0.143 s 4.00 255 0 0 0- 0 0 0 0 0 t-G 1Ao1om 1270 a 35.56 34.77 0 0 0 0 0 0 0 0 13AAocs - 0143 w 4.00 265 0 0 0 .0 0 0 .0 0 y1Acicnn : .. .1270 w„ _- 35,56. 55.21 0 0. ..0. 0. ,. 0 0 ..:00 4A5-tam .0.770 w 21.56 19.31 - 0 . 0'. . 0 ' .0 d . A `... P. 12C4isw 0.091 - 255 1.28 0 0 0 0 64 64 163 82 C r' ;16A.10riid' - `0.032'- - .' .0.90 "" 232' '64 .. .54. 48 125. 172 `172 i' . 154 399 F 22Atpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AlD excursion -9 -170 Erwdope loss/gain 48 117 317 311 12 a) trdiltra0on 0 0 0 0 b) Room vemilaticn 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1128 Total room load 64 174 418 3437 Air required (cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . A wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...uick CalcSlDocumems\THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone: 7724666799 Fax 7724686796 Email: DUICKCALCS@AOLCOM 1 Room name BATH BEDROOM 2 Rmad wall 5.0 ft 34.2 ft 3 height 8.0 If heat/000l 8.0 ft heat/coot 4 Roam dimensions; 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft- 203.5 ft- TY Construction U-lalue. Or HTM Area (ftj Load Area (ft2) Load number (Btuh/fti F) (Btuh/ft) or perimeter (ft) (Btuh) or paameter (ft) (Btuh) Heat Cool Gross WKS Heat Cool Gross N/P/S Heat. Cool 8 Vy;.�.;T3A4ocs ' ,. - . ,= 0 743 n ` - 4.00 $;55 40 ^ 40 - -; 180 , 102 128 Y28 - 513 `+326 -.0770 n `-.�21.56 - ! 19.31 -4.0 -' . 0 , 0 ...0' ..' 0 0 13A-0acs 0.143 e 4.00 255 0 0 0 0 60 56 225 143 %elom 1.270 a 35.55 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 e. 10.92 11.31 0 0 0 0 0 0 0 0 `D W . -'.13A-0ocs - 0.143 se .4.00 255 0 - 0 0 0 34 ..34 136 86 y/ 13A4ccs 0.143 s 4.00 265 0 0 0 0 32 32 - 128 81 fir' tAclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 - AaMocs - 0143 w 400 " 265 0` 0 0 0 0 0 0 0 1Aclomc.�; 35.56 ' . 55.21 .0 _ - _ ,0 0 ..t. • . 0 - . -0 '0 '... - 0 - �0 C4A5.2om :-- .`10770 "w =":21.56 ^i19.31: 0- - 0- .0 .0' •,0 ..,0 r" 0,,.. -"-'-. 0 P 12C-0sw 0091 2.55 1.28 0 0 0 0 0 0 0 0 C .-'.'16A-30ma ''. .. •. b.o32 o.90 - -2.32 r.. -45-' 45 .:-. ".40, 104 �.:- '204, -204 `:: .' a82 -472 F _ 22A4o1 0.969 27.69 0.60 45 5 138 0 2D4 34 946 0 6 c)AED exursion -16 -85 FJnelope loss/gain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 _ b) Room ventilation0 0 - 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other -0 0 Subtotal Qines 6 to 13) 425 214 3671 3498 Less external load 0 0 '0 0 Less transfer 0 0 0 " 0 Redaldbution 0 0 0 0 14 Subtotal 426 214 3571 3498 15 'Duct loads 320/6 49% 135 104 32% 49% 1131 1704 Total room load 560 318 1 4702 5203 Air regwred(cfm) 28 14 232 232 . A wrightsoTt' RigWflufte® Universal 2017 17.0.14 RSU08101 2017 Apr 11 0 Page .:.uick CaloslDocuments\THE GRAND CARLTON-1448.mp Cale = MJ8 Front Door faces: N wrightsoftRightwA) Worksheet Job: Entirci Hbdse Date: QUICK CALCS, INC. Ely:- 317 ST. LUGIE Uft, FT PIERCE, FL 34946 Phone: T72-466-6799 Fax 772AO"796 Enrol: QUCKCALCS@AOL.COM 1 Room name LAUNDRY GREATID[NNG 2 3 =ad wall height 6.0 ft 8.0 it heat/cool 47.0 ft 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42-0 ft' 1.0 x 626.0 ft 526.0 fP Ty Constructim number U-.dw F) (Btuww Or HTM (BtUWft2) Am or perimeter (ft) Load (Btuh) Am (fit2) or perimeter. (ft) Load (Btuh) Heat Cool Gross NIPIS Heat Cool Gnus NIPIS Heat Cool 6 '43x-0ocs- 0.143 n' 265 �0' 0 0 .0 2M -217 1366 .,652 4A5-tom -0.770 n; MIS 19.31 0 0 0 to 381. '0 -8115 ��730 V6 13A4ccs 0.143 a 4,00 Z55 0 0 0 0 0 0 0 0 1 1A,c1cm 11D0 1270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W , Y—G 1344ocs 13AAccs 1Aclom 0:143 0.143 1270 se a a 4.00 4.0D 35.55 265 255 34.77 0 48 0 0 48 0 .0 192 a .0 122 a 0 0 0 0' 0 01 0 0 13 0 0 a 0143["'w 1, 55 0 0 0 'vo I J:Z70 W 6 5 21 0 0 0 0 4A5-2cm - 2 156 9 31 ji. :0 -0 '0 4110 -�4101 788 P -1 0091 56 72 0 C I= 0'. 42 38 97, .1220 F 22A-tor 0. 6 166 0 0 6 c)AED excursion -22 668 Fmclope loss/gain 539 270. 4997. 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal 01rea; 6 to 13) 643 298 5994 6112 Less ekemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14:Subtotal 643 298 6994 5112 15 Duct loads M. 496AI M41 1451 32%1 49% 1 18991 2490 Total Total ;;i load MI 4411 1 1 71M 1 7112 (cfm) 42 20 390 M 29:38 "Ift Afl- wrigllhtsoft' Right-SuiteV Universal 2D17 12017-Apr-11 OP age RSU08101 Page 4 ... ulck CalcsXDocumantsXTHE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N wrightsoft' RighW@ Worksheet Job: Entire House . Date: QUICK CALCS, INC. By: 317 ST. LUCIE ILIA, FT. PIERCE, FL 34946-Phone: 7724666799 Fax 772466-6796 Email: QUCKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 3 Eloosed wall Room height 7.0 it 8.0 it 8.0 it heat(cool 8.0 it heat/ocol 4 Room dimersions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 0 56.0 ft- Ty Construction U-value Or HTM Area Load(ft2) Load number (8tuMft'-°F) (BWIJftI or perimeter (ft) (Btuh) ors perimeter ft Heat Cocl Gross WP/S Heat Cod Gross WPIS Heat Cool 6 W r13A4ocs. -.. .0.143 �n _. 4.00 - 2:55 8::-:- .8 32 .- - 20 <p: 0:. ;; ..0 L--G .4AS2nm :-:.,: :0.770 6: 21.56 ' 19.31 .-.0 ..0 ...., 0 .0 . . 0 ,0 0 . '=:0 U,J13A-4ccs 0.143 a 4.00 255 48 27 108 ,0 69 0 0 0 0 G 1Ac1om 1.270 a 35.66 87.29 0 0 0 0 0 0 0 0 11 `D_ 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W ::13A-0dcs 0.143 se 4.00 2.55 0 0 0 0 0 0 ' 0 W �--G 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 .0 228 145 1Aclom 1270 s 3556 34.77 0 0 0 0 7 7 247 241 • .13A4ocs ;.. :0143 W 4.00 255 0 0 0 a 0 0 0 - 0 - 1Acicm _ .. - .. 1270 w - . 35.56 55.21 0 ;' 0 .. 0. .,0 - b ` 0 . __, 0 ; ^0 4A5-tam • . r,0770 ... w:' --21.56 19r31 _ 0. 0:: - 0 :: '0 .. 0°•: 0.' 0 .. -.;.'0 P '12d-0sm 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0 C. .._ 16A-3pmB, -. 0.032 . -- 0.90 232 50 60 . . 45 - ,116 . "56 r 56 = 50 _. 130 F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 ; 0 6 c)AED excursion Sg Envelope loss/gain 792 496 747 478 12 a) Vlfiltratilm 121 33 138 38 b) Room ventilation 0 0 0 0 13 internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 913 529 885 516 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 _ Subtotal 913 629 885 516 15 butt loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1165 768 Air required(cfnn) 59 35 58 34 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed .�GGA wrigFitsoR- RiehtSulte® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5 ...uick CaIcslDocuments\THE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: N 9 -- wrightsoftDuct System Summary Dab Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799. Fax 77246"796 Email: OUICKCALCS@AOL.COM For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 Cfm 1160 cfm Total effective length (TEL) 176 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (In) H x W (In) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 0x0 VIFx 23.3 115.0 st1 M. BATFFA h 768 58 34 0 0 OxO VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc' Diann H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx wri htsoft• 2017-Apr-11 09:29:38 g RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 �� ...uick CaIcs1Documents\THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 VIFx c }J{} wri htsoft Page 2 2017-Apr-1109:29:38 " r 9 - RightSuRe® Universal 201717.0.14 RSU08101 / ...uick Calcs\Documents%THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N