HomeMy WebLinkAboutPLANSC APPROVED PRODUCTS LIST TABLE t
- - MAXIMUM ALLOWABLE RAFTEF . -,-'ME, END POST, GROUND ANCHOR AND PAA-ASTENER SPACING SPECIFICATIONS
WIND SPEED I -
PRODUCT CATEGORY
SUB CATEGORY
MANUFACTURER
STRUCTURAL COMPONENTS
ROOF DECK
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
STRUCTURAL COMPONENTS
STRUCTURAL WALL
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
STRUCTURAL COMPONENTS
FLOOD VENT
FLOOD FLAPS, LLC
8x16 Flood Flap
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
Series 402-14
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
Series 407
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door -8' Wide
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door-1 O' Wide
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door-12' Wide
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door -16'' Wide
EXTERIOR DOORS
ROLL -UP
ASTA INDUSTRIES, INC.
Model203 - Max. 12' Wide
WINDOWS
SINGLE HUNG -
MI WINDOWS AND DOORS
Model 185 SH
QA
APPROVAL
EXPIRATION
No. & DATE
DATE
FL6596.1-R5
04/05/27
10/10/17
FL6702.1-RS
03114/27
10/10/17
FL17381.1-R2
09/27/19
10/03/17
FL17996.3-R1
09/14/20
01/29/18
FL17996.5-R1
09/14/20
01/29/18
FL16806.2-R4
11/1120
06/18/19
FL16806.4-R4
11/11/20
06/18119
FL16806.1-R4
11/11 /20
O6/18/19
FL16806.3-R4
11111 /20
06/18/19
FL8888.01-R5
12131 /19
10/06/17
FL17499.1-R5
10/17/23
03/27M 9
OPEN
180
ISO
N/A
N/A
N/A
WA
WA
N/A
WA
WA
N/A
ON -CENTERS ALONG RAFTERS OR
PARTIALLY
MAXIMUM
PURLINS, AND POSTS OR GIRTS
ENCLOSED
ENCLOSED
RISK
WIND
EXPOSURE
ULTIMATE
WIND SPEED
NOMINAL
WIND SPEED
POST/RAFTER
SPACING
.(INCHES)
INTERIOR
END
180
180
CATEGORY
CATEGORY
(MPH)
(MPH)
(FEET)
POSTS/RAFTERS
POSTSIRAFTERS
180
180
110 TO 150
89 TO 116
5.0
6
6
I
C
151 TO 180
117 TO 139
4.0
6
6
N/A
WA
NOTES: 1. Spedikations applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18
gauge hat channel roof pudins.
156
138
2. Spectfiwtions applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). Spacing
requirements for other roof heights and/or slopes may vary.
165
147
ULTIMATE WIND SPEE
110 150
180
180
.120._130 .140.
12
ISO
172
14
30'Anchoi- -
d
16
Detal 1D -
I
�
179
154
18
l
Fi--
g
20_
4V Ancho
155 ., I
133
0
22
De1a111C
0
24
J
180
174
26,
m
28
175
157
30
NOTES:
DETAILS 1C AND ID SHOWN ON SHEE
1. DOORS AND WINDOWS SHOWN MAYBE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET:
METAL CARPORT INSTALLATION PLANS
AND D DETAILS AND FRAMING AND
FASTENER SPECIFICATIONS
FOR CONSTRUCTION IN THE STATE OF FLORIDA
PREPARED FOR:
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON, NORTH CAROLINA 27017
PREPARED BY.,
BECHTOL ENGINEERING AND TESTING, INC.
60'Alldwr
605 WEST NEW YORK AVENUE
Detail lC
DELAND, FLORIDA 32720
Certificate of Authorization No. 00005492
_
4OFfi
A PRODUCT SHALL HAVE A VALID. FBC PRODUCT APPROVAL:
B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURERS INSTALLATION REOURIEMENTS.
2 FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAYBE RAISED OR LOWEREDASNECESSARYTOACCOMODATE SRAMING CONNECTIOTEb NS -
GENERAL NOTES: REVIEWED FOR He Cop _ RECEIVED
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN IS, �II PI 111 _NCE --
PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET-BACKS,.FINISHFLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OT SRT. VV
2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF, SUPPORTING DEAD LOAD 0 11 HE STRUCTURE AND APPLICABLE LNEd N IT_L��S.�PRdOEN Sr
NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THEFBCAPPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND ;INSTAALLLL�� ��AAFF��BBLLINA
CARPORTS, INC.; WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERINGAND TESTING, INC.; SHALL NOT BE RESPONSIBLE FOR STRUCTURAL b@bk FAILURE
DUE TO THE APPLICATION OF ADDITIONAL LOADS:
3. ALL STEEL TUBING. SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 1
4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE
LOCATION OF THE BUILDING. WITHIN THE STATE OF FLORIDA. - - -
6. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4' SELF DRILLING SCREWS WITH CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 .4XW1 .4
WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING
AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
8. CONCRETE ANCHORS. SHALL SE TAPCON REDHEAD LOT 1/2' x FOR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9. POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS.
10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017)- RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SIXTH
EDITION (2017) -BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED.
11. 14 GA FRAMING: 2-1/2' x 2-12' TUBE STEEL (TS) WITH 2-1/4' x 2-1/4" TS NIPPLES. 12 GA FRAMING: 2-1/4° x 2-1/4° TS WITH Y x 2' TS NIPPLES.
12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF
OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER
EVERY 220 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED B'
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARI
ACCORDANCE WITH THE REQUIREMENTS-0FSECT
THE FLORIDA BUILDING CODE, SIXTH EDITION (2017
ARE VALID UNTIL THE NEXT REVISION OF THE FLOF
BECHTOL
6D5 WEST NE
,nw,ea r.e.
F7wWe i*�
CAROLI, P
GENERIC PLANS FOR
NOV 0 4 2019
HE
fMlucie County, Permltting
euPLMc SCANNED
BY
St. Lucie County
��l�W� •.�V•
IIMg \TATE OF FLORIDA
BECHTOL EA/G/NEERlNG RR NTS
AND T151=14%I'm
BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF
TYPICAL SIDE ELEVATION
NOTTOSCALE
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF
C
TYPICAL SIDE ELEVATION
NOTTOSCALE
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN_ CARPORT - VERTICAL ROOF
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOTTOSCALE
TYPICAL BOW RAFTER GABLE END ELEVATION
NOT TO SCALE
BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF
FLOOD VENT W eo W.i
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOTTOSCALE
BOX SAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF
BOW FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOTTOSCALE
FRAME RAFTER UTILITY BLDG -
ROLLi1P
(As epp
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION I TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOTTOSCALE' - - NOT TO SCALE NOTMS'CALE NOTTOSCALE
RAFTER ENCLOSED BLDG -
TYPICAL SIDE ELEVATION
NOTTOSCALE
File CoP
TYPICAL BOX EAVE RAFTER GABLE END ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOTTOSCALE
CODE COMPLIANCE
ST. LUC 9,QQUNTY
BOX EAVE FRAME RAFTER UTILITY BLDG -
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL BOX EAVE RAFTER GABLE END ELEVATION
NOT TO SCALE
FlmMA
ROOF
TYPICAL.END E1110N 111,
�
NOT TO SCALE. �"l NBEy�—
R • ..
CAROLINA CARPO
dog ..NC.
.•'
%
LWL1
i
pSEOF
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
J BECNTOL ENGINEERING
AND TE9NNG, Inc
mYLL10O4IDRti-•'.. G•/�ENl.4-011V6WdrtfIW 4u9tflO
hmI IANLbpmW.
RR
-26 GA GALVAN® METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
12 2
'24' iS GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) 412-14 x 3/4' SDP§ AT
EACH END H PER BRACE)
TYPICAL
INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME
NOT TO SCALE
SEE
L 24'-l" TO 30' T
RAFTER
A. GALVANIZED METAL ROOF PANELS 26 GA GALVANIZED METAL ROOF WWI
'EKED TO RAFTERS PER MANUFACTURERS FASTENED TO PURUNS PER MANUFAC
ALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS
12 142' 18 GAUGE FURRING
24' 16 GA U-CHANNEL BRACE
FASTENEDTO RAFTER WITH
(2) 812-14 x 314' SDF8AT
EACH END (4 PER BRACE)
TYPICAL INTERIOR RAFTER/POST
FRAME SECTION - BOX EAVE - HORIZONTAL ROOF
NOTTOSCALE
END WALL OPENINGS
NOT TO SCALE
24' 16 GA UCHANNEL BRACE
FASTENED TO RAFTER WITH
(2) 912-14 x 3/4' SDPaAT
EACH END (4 PER BRACE)
TYPICAL INTERIOR
RAFTER/POST.FRAME SECTION - VERTICAL ROOF
NOT TO SCALE
7-IW 18 GAUGE FURRING CHANNEL FASTENED
-TO EACH RAFTER WITH (2) a12-14 x 34' SELF-DRBLNG
MV bPAUW NOT MORE
THAN 48. O.C.
O
4
SEE
TABLE 1
SHEET
IOF6
LENG VARIES DEPENDING ON NUMBER
AND SPACING OF RAFTERS
TYPICAL
POST/RAFTER
FRAMING PLAN -VERTICAL ROOF
ILL l�l'hl✓'.la
TYPICAL BOW RAFTER GABLE END. FRAMING PLAN
NOT TO SCALE
TYPICAL BOX EAVE RAFTER GABLE ENDFRAMING PLAN
NOT TO SCALE
1
REVIEWED FOR s
CODE COMPLIANCE
I LUCIE T. y_ 5
BOCC 24.1EGA TO
BRACE 2
FASTENED TO RAFTER Wfi1). 4
(2)412-14 x 3M' SELF-DRILUNG
,A SCREWS AT EACH END
(4 PER BRACE)
He
L
OPTIONAL 24'-1"TO 30' TRUSSED RAFTER - BOX EAVE
NOTTOSCALE ..
ROOF DcrENSION OPTION MAINSTRUCTURE STANDARD
TYPICAL LEAN-TO OPTIONS FRAMING PLAN BOTH OPTIONS SH W \%
NOTTO SCALE (BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS APPLICABLE TO BOW _ �•C".7%O ////
VMNEL BRACE IT TO 7'POST) _ l 9E •••� i
BECHTOL ENGINEER] T NO, INC.
BRACE ANGLE SHALL BE MIN.ST) E 6
BRACE ANGLE SHALL BE MIN-3M EAMND. O A uE O: - 3553 •••
TO MAIL 45' FROM HORIZONTAL CeRfirEOB W tio" H _' O' y -
li Lw :
2
4 \ `
Flarltla Llrorisa'P.E i� S(p• Q,: ��
CAROLINA CARPORT CL7.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
BECHTOL ENGINEERING RR _ - NTB
AND TESMa b,c
mmaw®rto.rxrx..wca.,r.v..w..mwamweue.rFu °ma' RR 1°°"m G166OI .
�'a�'a� - ETA 'CYGR 9l1Ca
/ \THROUGH BASE RAIL WITHIN 6'OF EACH
RAFTER POSTS ALONG SIDES AND EVERY END
WALL POST ALONG END WALL SECTIONS
—4• MINIMUM r MINIMUM
MINIMUM 2.10 EMBEDMENT
e
12•
MOOLITHIC CONC. FOOTING (2800 PSI MIN.)
REINNFORCED WTIH 2 #Se CONTINUOUS
NCR
1A ETE BAS
Not TO
DRILL 5V HOLE THROUGH THE �rWAQumc
ANCHOR EYE WITH
J-
TS CONTINUOUS
BASE RAIL
(SEE GROUND ANCHOR
SCHEDULE, SHEET I OF 6,
FOR REWIRED ANCHOR)
CONTINUOUS 4-
CONCRETE PAVEMENT
EYEANCHOR-- '
CONCRETE BASE RAIL ANCHORAGE
�� NW Ta Sgle (OPEN CN7PORTS WHERE STAB EDGE DISTANCEDOFS NO7
Ir1EETMININUM EDGE DISTANCE SHOWN IN DETAR 1B)
TS TRUSSED RAFTER CHORD, /
3R NONSTRUCNRAL HEADER J
TS END POST OR DOOR/
WINDOW FRAME POST - ri2•xr16GAANGLE CLIP
SECURE TO POST (EACH SIDE)
A
TSBASEAYINDOWRAILORAND RAFTER CHORD/RNL WITH
NONSTRUCTURAL HEADER(4)#12-14x 314'SDFs,(2) ON
2 GA IF ROLL -UP DOOR FRAME)TOP OR BOTTOM, (2) ON SIDE
NOTE: AT ROLL -UP DOOR
OPENINGS, POST SHOULD
BE FLUSH WITH RAIL END.
CLIP POSTTO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
TO RAIL, TRUSS CHORD, OR
4
MINIMUM 6'TAPCONREDHEADLDT
2•x MINIMUM S•12• EXPANSION ANCHOR
iE RAIL WITHIN S' OF EACH
5 ALONG SIDES AND EVERY END
.ONG END WALL SECTIONS
6•
MINIMUM4•—
NTINUOUS 4'CONCRETE PAVEMENT
,"1 CONCRETE BASE RAIL ANC
B 7 Crv�6 rnCnnuel -Mier oonoTe run vi
24' IS GA U•CHANNEL BRACT
48' 16 GA UCHANNEL BRACE
RAFTER POST
,EMBEDMENT
'OST TO NIPPLE WITH
x 314• SOPS
TZBOX EAVE RAFTER/POST DETAIL
� NMTO Scale � -
REVIL> "�> �.
CODE C PAPUk-
ST. LUCK Cai.Ni A. -
BOCm
TS RAFTER POST
Y-12• x 1-12• x r 16 GA CUP
ANGLE SECURE TO
POSiANDSASE RAIL
WITH (4) 012-14 x 3N• SDPs,
(2) ON TOP, (2) ON SIDE
CONTINUOUS BASE RAIL
END POST/BASE RAIL CONN.
Not To Scale
DRILL S18• HOLE THROUGH THE
SASE RAILANO SECURETO
ANCHOR EYE WITH 12' DIAMETER
TOP OFASPHALT F
ORSTABLEGROUND
WASHERS DRILL 518' HOLE
BASE RAILA
—TS CONTINUOUS ANCHOR EYE WITH
BASE RAIL T
EYEANCHOR
618' ROD 4r LONG
WITH r HELIX
OR
Sl8'ROO68•LONG
(SEE GROUND ANCHOR
WITH THELM
SCHEDULE, SHEET I OF 6.
AS APPLICABLE
FOR APPLICABILITY)
BASE RAIL DEEP ANCHORAGE
Not TOSONa
TS BOW RAFTER
POST.
WASHERS
EYEANCHOR U (SEEGROUNDANCHOR
SW ROD 30•LONG SCHEDULE, SHEET! OF 6,
WITH DEL 4•HELD( FOR APPLICABILITY)
-24' 16 GA UCHANNEL BRACE (S SO T POST)
46. 16 GA UCHANNELBRACE (S TO 14• POST)
BRACE ANGLE SHALL BE MINA 51
TO MAX 60' FROM HORIZONTAL NIPPLETO
BASE RAIL
BOW RAFTER/POST DETAIL
Not To Sml
POST
T a 2' x 2.16 GAANGLE CLIP
SECURE TO POSTAND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIL/GIRT WITH (4) 012.14 x 314' SDPs
(2) ON TOP OR BOTTOM, (2)ON SIDE
TS WINDOW RAIL OR GIRT
FOR VERTICAL SIDING OPTION
NON-STRUCTURAL HEADER, WINDOW
RAIL,.. OR GIRT TO POST CONN. DETAIL
Not To Scale -
BASE RAIL ANCHORAGE
tu. Nat TO S¢le
6• LONG TS NIPPLE
SECURE POSTTO NIPPLE
WITH (4) 012-14 x 314• SOPS
BASE RAIL
POST/BASE RAIL CONN. DETAIL
Not To Swe
J� ..N• BE�yT
TING, IN
y D 3g538 •
N
LII
Ill
SZptEo •
///I/sslos N
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
AVBECHWL ENGINEERING
AND TESTING, Ina
maamamrxamus rr+ea•.anrk.xmu.+wuamveram�w
c.saexe.xr,.x.mmm -
ZNZ` C' 16 GA ANGLE CUP
SECURE TO POST AND
RAFTER WITH (4) 912-14 x 314'
SDFB, (2) ON BOTTOM,
(2) ON SIDE
OR
2*x4' 16 GA PLATE
SECURETO EACH SIDE OF
TS END POST POSTIRAFTER CONNECTION
WITH (4) 912-14 x 314-Son.
(2) ON POST, (2) ON RAFTER
END POST/RAFTER CONN. DETAIL
1 NM To Stale
1.17 x 1-72' x 716 GA
CLIP ANGLE SECURE TO
RAFTER POSTAND GABLE
RAIL WITH (4) 912.14 x 3W Son
(2) ON TOP, (2) ON SIDE
1.112* x I-Vr x 2' 16 GA CUP
ANGLE SECURE TO RAFTER
AND CABLE RAIL WITH (4)
912-14 x 314- SOFB, (2) ON TOP,
(2) ON BOTTOM
GABLE RAIL TO RAFTER POST
.CONNECTION DETAIL
i iA Not To Sotle
BRACE SECTION
Not To Sede
NIPPLE TC
DEL MDR.
S' LONG TS NIPPLE
SECURE EACH WITH
(4) 912-14 x 314-
SELF-DRILLING FASTENERS
CA TS POST
6' LONG TS NIPPLE
SECURE WITH (4) 912-14 x 3W
SELF -DRILLING FASTENERS
DOUBLE TS HEADER
NIPPLETO
DBL MDR.
RAFTER POST/DBL. HEADER DETAIL it RAFTER POST/HEADER DETAIL
� NotToSde � -
NW To Soale
1-02'x 1-1TI x 716 CA CUP ANGLE
SECURE 70 RAFTER POSTAND
GABLE RAILWTTH (4)912.10x&4'SDFe, NIPPLETO�\\ 3N6'
TOP AND BOTTOM RAFTER / ✓I /VLONGTSNIPPLE
SECUREWITH(4)912-1`4x314'SDFB
TS RAFTER 17 LONG TS NIPPLE
SECURE POST TO NIPPLE
1-11rx1-17x2.16
SECURE TO RAF
(2) ON
'S' LONG TS NIPPLE
SECURE RAFTER AND POST TS CABLE RA
TO NIPPLE WITH (4) 912.14 x 310
SELF4)RBLING FASTENERS
TS RAFTER POST
GABLE RAIL TO RAFTER POST
R CONNECTION DETAIL
I� NWT. Scale
1.1018 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) 912.14 x 314' SOP
SPACED NOT MORE THAN 48' O.C.
28 GA METAL ROOF
PANEL
TS RAFTER
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Scale
24. 16 GA U.CHANNEL BRACE (STOT POST)
48' 18 GA U-CHANNEL BRACE (S TO 14• POST)
BRACE ANGLE SHALL BE MIN.45-
TO MAX. 68' FROM HORIZONTAL
POST
H WITH(4)912.14 x 314'
IG FASTENERS
GA TS POST
BASE RAIL
V \ BASE RAIL
RAFTER POST/BASE
BASE RAIL CONNECTION DETAIL
tv Not To Seale
OF
(2) ON RAFTER
ITS LEAN-TO RAFTER
ZW'x2' 16 GAANGLE CUP
SECURETDPOSTAND
RAFTER WITH (4) 912-14 x 3W
SDPx, (2) ON RAFTER
(2) ON POST
SIDE EXTENSION POST / LEAN-TO RAFTER CONN. DETAIL
-RAFTER/POST DETAIL Notresvle
NotTu Scale REVIEWED -FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
_ BECHTOL ENGIN ER N�Af�D 6,1 iby
TS LEG POST 'f TS LEG POST�711 BOCC 6a6WESTNEWYOi'-'.. �Y
ncl aun n relne a •nENSR --•- Tip
TS RAILS TS POSTS
CeNficate of
6
E 538
1 4
Thomas Beelrt , Pi *• '
���i
TS BASE RAIL 8'
�Qp Fb4de Llo3irse \
r
�A ' STATE OF :
�i0it�''•, FLORIOP;•'
TYPICALFLONCOPLAN
ON A\- �'? \`•
VENT
NOTTOSCALE
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
SEE GENERAL NOTE No. 12, SHEET 1 OF 6.
7116/19
MVBECHTOL
ENGINEERING RR Nis
AND TESTWG, Ne
RR G18881
rauut.aa®Rcwc,�rmaQua„m.rmw+wrutrnme.oavw
�TB SHEET60F8,
VERTICAL SIDE OPTION
GIRT
(TTPicei
TYPICAL END
WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN,
NOTTOSCALE - -'
BOX EAVE FRAME
TYPICAL SIDE ELEVATION
NOTTOSCAIE
A
TWINGING DOOR
JCTURAIL HEADER
- VERTICAL SIDES
TYPICAL END ELEVATION
NOTTO SCALE
1-1A2. 18 GAUGE FURRING CHANNEL FASTENED TO
EACH RAFTER NiTH (2) 012-14 i 3W SEX -DRILLING
r--I I— FASTENER SPACED NOT MORE THAN 46• oG
GIRTS_<
(WWI) \
OPENING FOR SWINGING DOOR
WITH NONSTRUCTURAL HEADER
Itl®I®i-I®I�I�Isil
I
TYPICAL POST/RAFTER/GIRT FRAMING PLAN -
NOTTOSCALE
BOX EAVE FRAME RAFTER UTILITY.BLDG -
ROLL -UP DC
(AS aPPfila
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOT TO SCALE
File Copy
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
22;r
c N !3 38 O`
anae E4tlrtd - -
FWdaLk-
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
un .TN5M9
SECHTOL ENGINEERINGRR� NTS
.AND TESIDN, M .
e'�" RR ""O'-" G19WI
�s.wm,r�"®m -
'""@7B SHEET6OF6 .'