Re: Carport Ready Attachment (Host Beam) Verification: RECEIVED
LOT 125—TALL P I N ES, 314 S ERI E DR, FORT PI ERCE, FL 34946 NOV 04 -019
SERIAL— WHCO25463GAAB ST. Lucie County, Permitting
To Whom It May Concern;
The above listed Clayton manufactured home has been constructed with a structural
attachment beam, or "host beam". The hose beam design and the home plans are both
approved in accordance with the requirements of the Federal Manufactured Home Construction
and Safety Standards commonly referred to as the "H UD Code% The design of this host beam
allows an attachment (typically sheds, carports, screen rooms, etc...) to be made directly to the
included structural member in lieu of the typically required "fourth wall construction". Please
refer to the serialized floor plan provided by Clayton Homes to verify the location of the host
beam.
The attached manufactured home plan is required to be set-up or installed, on -site, in
accordance with the Clayton Homes "Set -Up Manual' and its "Addendum". Please refer to SU-S-
93.0, SU-S-93A.0 AND SU-S-9313.0, which includes site requirements that must be followed in
order to attach a structure to the host beam provided. These pages also has the maximum sizes
allowed for any attached structure along with the requirements for perimeter blocking along the
entire sidewall area where the host beam is installed.
All site installed structures shall be designed by a Professional Engineer (PE) registered in the
State of Florida or as allowed by the Local Authority Having Jurisdiction (LAHJ). The design shall
comply with all applicable sections of the Florida Building Code that is in effect during the time
of the construction of the addition. All attachment designs and construction are by others, not
Clayton Homes. Any site installed structures shall be subject to permitting, plan review and
inspection(s) by the LAHJ.
If I can be of further assistance, please feel free to call me at 877-509-9299 extension 120.
Sincerely,
Terrell Spaulding a^�
Market Development Manager,91
o 2
Clayton Homes— Waycross Home Building Facility Q
vo c
3350 INDUSTRIAL BLVD. WAYCROSS, GEORGIA 31503 (912) 283-6400 (912) 283-4036
LOT 125—TALL PINES, 314 S ERIE DR, FORT PIERCE, FL 34946 SERIAL— WHCO25463GAAB
CARPORT
FOR MAXTIE-0OWN ANCHOR
SPACING, WFERTO SU_SS3A
VERTICAL TIE -DOWN STRAPS
TYP. GROUND ANCHOR PER
T . Sidewall App.
ATTACH CARPORT TO SIDEWALL PER
MANUFACTURERS INSTALLATION
INSTRUCTIONS AND THE LOCAL —
AUTHORRY HAVING JURISDICTION.
(SEE DETAIL 'Al
PERIMETER BLOCKING REQUIRED AT
B'�os. MIN. FOOTING SIZE IS 21 Sg1rL
FOOTING DEPTH PER TABLE 8 & IDA .
IN INSTALLATION MANUAL
FOR MAX PIER
HEIGHT REFERTO
DETAIL SUSSM
FOR STRAP ANGLE REFER
TO DETAIL SU.0.935
(TYP) PIER
REFER TO TABLES 6b & 60 IN
INSTALLATION MANUAL FOR
SPACING REQUIREMENTS
ATTACH CARPORTTO ENDWALL PER
MANUFACTURERS INSTALLATION
INSTRUCTIONS AND THE LOCAL
AUTHORTYHAVINGJURISDICTION,
CARPORT ATTACH CARPORT DIRECTLY TO
ENDWALL FRAMING PRIOR TO
INSTALLING SIDING ON ENDWALL
ISEE DETAIL'S')
VERTICALTIE•DOWN STRAPS
THIRD PARTY LISTED
ROOFTRUSS —
SITE INSTALLED
CARPORT —
FACTORY
INSTALLED RAIL
MAY BE COVERED
WITH EXTERIOR
ATTACH CARPORT T02x6/
PAINTED MATERIAL
OR 2X6 AS REQUIRED BY
CARPORT INSTALLATION
VINYL SIDING
INSTRUCTIONSAND
LOCAL AUTHORITY
n Typ. Sidewall App.
~ SCALE
THIRD PARTY LISTED
ROOF TRUSS SITE INSTALLED
CARPORT �
-- _j—� FACTORY
--- INSTALLED RAIL
MAY BE COVERED
WITH EXTERIOR
ATTACH CARPORTTO 2[10 AS PAINTED MATERIAL
REQUIRED BY CARPORT
INSTALLATION INSTRUCTIONS VINYL SIDING
AND LOCAL AUTHORITY
B T . Endwall A
SCALE: 3(B =1'
TYR GROUNDANCHOR PER
�— gyp) PIER
_��
INSTALLATION MANUAL
REFERTOTABLE56b&6c
ININSTALLATIONMANUAL
WINOZONEAPPROVAL
FORSPACING
Typ. Endwall App.
REQUIREMENTS
WIND ZONE BI
SCALE: 3/16b1
ONLY
GENERAL NOTES:
1. APPLICABLETO ALL DOUBLE WIDE UNITS FOR
WIND ZONE ILL 20 PSF MAX. S-0 MAX
SIDEWALL HEIGHT. CARPORT ROOF TO HAVE
A 1 PSF MAX. DEAD LOAD,
2. IN LOCATIONS WHERE ROOF LIVE LOADS IN
EXCESS OF 10 PSF ARE EXPECTED. THE
CARPORT SHALL BE INSTALLED COMPLETELY
FREE STANDING.
3. PIERS AND FOOTINGS REQUIRED UNDER MAN
MSEAMS PER INSTALLATION MANUAL
4. 1000 PSF MIN. SOIL BEARING CAPACITY
REQUIRED.
S. TIEDOWN STRAPS AND GROUND ANCHORS
RATED FOR A MINIMUM WORKING LOAD OF
31501".
B. THIS DETAIL IS APPLICABLE FOR 4.3W12 ROOF
PITCH MAX
]. SUPPORT, DESIGN AND CONNECTIONS FOR
CARPORT SHALL MEET REQUIREMENTS PER
MANUFACTURER'S INSTALLATION
INSTRUCTIONS AND L LAUTHORITY
HAVING JURISDICTIO
r
Q.
n
mr
,-<z
Ref. Ca1c. # 1,2&6 8/11/9
SD-SU # 1 8/11/9
1AAl _A:/
o
OCT 23 2009
o�
o
a
'- Fedua MmufKW d m
QHUI=COUSDMCGOR v
And SBfUy Swdu*
Site Installed Carport Installation I HaTx
r