Loading...
HomeMy WebLinkAboutMISC EMAILW �' ■ ■, SCANNED BY homes St. Lucie County Re: Carport Ready Attachment (Host Beam) Verification: RECEIVED LOT 125—TALL P I N ES, 314 S ERI E DR, FORT PI ERCE, FL 34946 NOV 04 -019 SERIAL— WHCO25463GAAB ST. Lucie County, Permitting To Whom It May Concern; The above listed Clayton manufactured home has been constructed with a structural attachment beam, or "host beam". The hose beam design and the home plans are both approved in accordance with the requirements of the Federal Manufactured Home Construction and Safety Standards commonly referred to as the "H UD Code% The design of this host beam allows an attachment (typically sheds, carports, screen rooms, etc...) to be made directly to the included structural member in lieu of the typically required "fourth wall construction". Please refer to the serialized floor plan provided by Clayton Homes to verify the location of the host beam. The attached manufactured home plan is required to be set-up or installed, on -site, in accordance with the Clayton Homes "Set -Up Manual' and its "Addendum". Please refer to SU-S- 93.0, SU-S-93A.0 AND SU-S-9313.0, which includes site requirements that must be followed in order to attach a structure to the host beam provided. These pages also has the maximum sizes allowed for any attached structure along with the requirements for perimeter blocking along the entire sidewall area where the host beam is installed. All site installed structures shall be designed by a Professional Engineer (PE) registered in the State of Florida or as allowed by the Local Authority Having Jurisdiction (LAHJ). The design shall comply with all applicable sections of the Florida Building Code that is in effect during the time of the construction of the addition. All attachment designs and construction are by others, not Clayton Homes. Any site installed structures shall be subject to permitting, plan review and inspection(s) by the LAHJ. If I can be of further assistance, please feel free to call me at 877-509-9299 extension 120. Sincerely, Terrell Spaulding a^� Market Development Manager,91 o 2 Clayton Homes— Waycross Home Building Facility Q vo c 3350 INDUSTRIAL BLVD. WAYCROSS, GEORGIA 31503 (912) 283-6400 (912) 283-4036 LOT 125—TALL PINES, 314 S ERIE DR, FORT PIERCE, FL 34946 SERIAL— WHCO25463GAAB CARPORT FOR MAXTIE-0OWN ANCHOR SPACING, WFERTO SU_SS3A VERTICAL TIE -DOWN STRAPS TYP. GROUND ANCHOR PER T . Sidewall App. ATTACH CARPORT TO SIDEWALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND THE LOCAL — AUTHORRY HAVING JURISDICTION. (SEE DETAIL 'Al PERIMETER BLOCKING REQUIRED AT B'�os. MIN. FOOTING SIZE IS 21 Sg1rL FOOTING DEPTH PER TABLE 8 & IDA . IN INSTALLATION MANUAL FOR MAX PIER HEIGHT REFERTO DETAIL SUSSM FOR STRAP ANGLE REFER TO DETAIL SU.0.935 (TYP) PIER REFER TO TABLES 6b & 60 IN INSTALLATION MANUAL FOR SPACING REQUIREMENTS ATTACH CARPORTTO ENDWALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND THE LOCAL AUTHORTYHAVINGJURISDICTION, CARPORT ATTACH CARPORT DIRECTLY TO ENDWALL FRAMING PRIOR TO INSTALLING SIDING ON ENDWALL ISEE DETAIL'S') VERTICALTIE•DOWN STRAPS THIRD PARTY LISTED ROOFTRUSS — SITE INSTALLED CARPORT — FACTORY INSTALLED RAIL MAY BE COVERED WITH EXTERIOR ATTACH CARPORT T02x6/ PAINTED MATERIAL OR 2X6 AS REQUIRED BY CARPORT INSTALLATION VINYL SIDING INSTRUCTIONSAND LOCAL AUTHORITY n Typ. Sidewall App. ~ SCALE THIRD PARTY LISTED ROOF TRUSS SITE INSTALLED CARPORT � -- _j—� FACTORY --- INSTALLED RAIL MAY BE COVERED WITH EXTERIOR ATTACH CARPORTTO 2[10 AS PAINTED MATERIAL REQUIRED BY CARPORT INSTALLATION INSTRUCTIONS VINYL SIDING AND LOCAL AUTHORITY B T . Endwall A SCALE: 3(B =1' TYR GROUNDANCHOR PER �— gyp) PIER _�� INSTALLATION MANUAL REFERTOTABLE56b&6c ININSTALLATIONMANUAL WINOZONEAPPROVAL FORSPACING Typ. Endwall App. REQUIREMENTS WIND ZONE BI SCALE: 3/16b1 ONLY GENERAL NOTES: 1. APPLICABLETO ALL DOUBLE WIDE UNITS FOR WIND ZONE ILL 20 PSF MAX. S-0 MAX SIDEWALL HEIGHT. CARPORT ROOF TO HAVE A 1 PSF MAX. DEAD LOAD, 2. IN LOCATIONS WHERE ROOF LIVE LOADS IN EXCESS OF 10 PSF ARE EXPECTED. THE CARPORT SHALL BE INSTALLED COMPLETELY FREE STANDING. 3. PIERS AND FOOTINGS REQUIRED UNDER MAN MSEAMS PER INSTALLATION MANUAL 4. 1000 PSF MIN. SOIL BEARING CAPACITY REQUIRED. S. TIEDOWN STRAPS AND GROUND ANCHORS RATED FOR A MINIMUM WORKING LOAD OF 31501". B. THIS DETAIL IS APPLICABLE FOR 4.3W12 ROOF PITCH MAX ]. SUPPORT, DESIGN AND CONNECTIONS FOR CARPORT SHALL MEET REQUIREMENTS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND L LAUTHORITY HAVING JURISDICTIO r Q. n mr ,-<z Ref. Ca1c. # 1,2&6 8/11/9 SD-SU # 1 8/11/9 1AAl _A:/ o OCT 23 2009 o� o a '- Fedua MmufKW d m QHUI=COUSDMCGOR v And SBfUy Swdu* Site Installed Carport Installation I HaTx r