General Notes
A. CONCRETE & FOUNDATION DESIGN:
1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000
PSI MRVIMUM.
2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI
MINIMUM, 3 1/2" NOMINAL THICKNESS.
3. 3000 PSI FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING
APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED
IN LIEU OF WELDED WERE MESH
4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH.
TERMITE TREATMENT OF SOIL BENEATH SLAB IS NOT
REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME
STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT
ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE
SOIL FOR WOOD DESTROYING ORGANISMS.
5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE
60 (60 KSI MIN.) DEFORMED BARS, 93 BARS MAY BE GRADE 40
6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL
BE 3000 PSI MIN., 2" MINIMUM. THICKNESS.
7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF.
8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE r
FOLLOWING:
OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150).
AGGREGATES - #6 STONE, ASTM C 33 SIZE NO.67 LESS THAN
3/4".
AIR ENTRAINING+/- 1%- ASTM C 260.
WATER REDUCING AGENT 1 ASTM C 494.
CLEAN POTABLE WATER.
OTHER ADMIXTURES SHALL NOT BE PERMITTED.
9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185.
10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN
CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1,
2, & 3 ALONG WITH HOT WEATHER CONDITIONS
RECOMMENDATIONS.
11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION,
CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS,
VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING,
SPALLING OR OTHER DETERIORATION.
B. MASONRY:
I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD
HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON
TYPE M OR S MORTAR
2.ALL MORTAR SHALL BE OF TYPE M OR S.
3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE
MAXIMUM COARSE AGGREGATE SIZE OF 3/8".
4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING
REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-0" IN
HEIGHT.
C. ALUMINUM:
1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE
MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A
MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS.
2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF
0.024" SHALL APPLY..
3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A-
SPECIFICATIONS FOR ALUMINUM STRUCTURES -ALLOWABLE
STRESS DESIGN" OR "PART 1-13 - SPECIFICATIONS FOR
ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE
FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN
MANUAL PREPARED BY THE ALUMINUM ASSOCIATION,
INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE, 6TH
EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20
ALUMINUM).
4. WHERE ALUMN'UM COMES INTO CONTACT WITH STEEL, OR
PRESSURE TREATED LUMBER PROVIDE DIELECTRIC
SEPARATION.
5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS
THAN 410 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF
USING #12 SPACING MAY BE 24" ON CENTER
6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY
SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING
"REMOVABLE PANEL SHALL BE REMOVED WHEN WIND
SPEEDS EXCEED 75 MPH'. DECAL SHALL BE PLACID SO IT IS
VISIBLE WHEN PANEL IS INSTALLED.
D. FASTENERS:
I. ALL LAGBOLTS SHALL CONFORM TO STAINLESS STEEL TYPE
300 18-8. WITH STANDARD FLAT WASHER UNLESS
MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE
WITH ACQ PRESSURE TREATED WOOD.
2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD
FLAT WASHERS AND NUTS.
3. ALL CONCRETE SCREWS SHALL BE, SEYIPSON, HB,TL BAWL,
TAPCON,REDHEAD, DYNABOLT, OR APPROVED EQUAL.
4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE
HOT DIPPED GALVANIZED.
5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X
BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.).
6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE
PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT
GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF
THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE
INSERTED IN PILOT HOLES BY TURNING AND UNDER NO
CIRCUMSTANCES BY DRIVING WITH A HAMMER
7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN
ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S
REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY
BE APPLIED IN CONDITIONS ACCEPTABLE TO
MANUFACTURER FASTENERS SHALL BEA MINIMUM OF SAE
GRADE #5 OR BETTER ZINC PLATED.
S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR
PRESSURE TREATED LUMBERARE STAINLESS STEEL TYPE 300
18-B, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES
FOR USE WITH ACQ PRESSURE TREATED WOOD, OR
OTHERWISE NOTED ON PLANS.
9. ALL FASTENERS SHALL COMPLY WITH ASTM A153.
1o. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS
G-185.
11- FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL
BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2"
UNLESS NOTED OTHERWISE.
E. REFERENCE STANDARDS:
ASTM E 119
ASTM E 1300
ASCE 7 -10
AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B
ASTM C94
ASTM C150
ASTM C33
ASTM C260
ASTM C494
ASTMA615
ASTM A185
FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23)
6TH EDITION
CURRENTALUMINUM DESIGN MANUAL
F. ABBREVIATIONS:
THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED
TO REPRESENTALL THOSE USED ON THESE DRAWINGS, BUT
TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS.
1. TYP-TYPICAL
2. SIM -SIMILAR
3. BON - UNLESS OTHERWISE NOTED
4. CONT-- CONTINUOUS
S. VIF--VERIFY INFIELD
G. RESPONSIBILITY:
I. ALL SITE WORK SHALL BE PERFORMED BYA LICENSED
CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING
CODES, LOCAL ORDINANCES, ETC.
2. CONTRACTOR SHALL VERIFYALL DIMENSIONS AND DETAILS,
NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN
DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD
CONDITIONS.
3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE
'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE
CONTRACTOR
4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED
ON INFORMATION PROVIDED BY THE CONTRACTOR AND
MANUFACTURER.
5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A
LICENSED P.E. IN ACCORDANCE WITH STANDARD
ENGINEERING PRACTICES.
H. MISCELLANEOUS:
1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A
MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME
WITHOUT A MANUFACTURER'S HOST BEAM.
IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT
SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL
LOADING IS PLACED ON THE MANUFACTURED HOME.
2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE
ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING
BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE
R 4501.17 IN ITS ENTIRETY.
3. DOOR LOCATIONS MAYBE DETERMINED IN THE FIELD BY
CONTRACTOR
4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL
HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT,
ENSURE BONDING AGENT IS USED FIRST.
S. SCREENING MATERIAL SHALL BE 18X14X0.013 OR
EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED
OTHERWISE.
6. EMERGENCY ESCAPE& RESCUE OPENING PER FBC R310.1
SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL
7. ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT
CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280.105, (a)
THROUGH (a)(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY
OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35', AND, SO THAT
TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT
OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE. NON -HABITABLE
SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXIT
DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS
THE REQUIREMENTS OF HUD 3280.105.
RECEIVED
NOV 9 4 %019
ST. Lucie County, Permitting
CARPORT, SHED, COVERED PATIO AND CONCRETE
DESIGN DATA:
1. ULTIMATE DESIGN WIND SPEED Volt, (3 SECOND GUST): ISOMPH
NOMINAL DESIGN WIND SPEED Vasd: 120 MPH
2. RISK CATEGORY: I
3. WIND EXPOSURE: B
4. INTERNAL COEFFICIENT:
SHED (ENCLOSED STRUCTURE): +/-0.18
CARPORT, COVERED PATIO (OPEN STRUCTURE): 0.0
S. WIND LOADS:
FACTOR APPLIED TO WIND LOADS FORALLOWABLE STRESS DESIGN: 0.6
SOLID ROOF (MWFRS): 25 PSF
COMPONENT & CLADDING PRESSURES:
ROOF ZONE 1: 10.5/-25.9 PSF, ZONE 2: 10.5/-43.5 PSF, ZONE 3: 10.5/-65.4 PSF
WALLS ZONE 4: 25.9/-28.1 PSF, ZONE 5: 25.9/-34.7 PSF
6. FOUNDATIONS PER"A" OF GENERAL NOTES AND SITE SPECIFIC DETAIL
7. SOLID ROOF TYPE: 3"X12"ALUM. PANS, FL 16952 OR EQUIV.
ALUMINUM STRUCTURAL MEMBERS
HOLLOW SECTIONS
2 x 2:--------------------------------2" x 2" x 0.044"
3 x 2: -----------------------------3" x Z" x 0.050"
2 x 3:---------------------------------2"
x 3" x 0.050"
2 x 3: -----------------------------2"
x 3" x 0.070"
2 x 4:--------------------------------2"
x 4" x 0.050"
2 x 5:----------------------------------2"
x 5" x 0.050"
OPEN BACK SECTIONS
1 x 2: - ----------------------------------1" x 2" x 0.040„
1 x 3:-------------------------------1" x 3"x 0.045"
SNAP SECTIONS
2 x 2 Snap: ------------- -------------- -2" x 2" x 0.045"
2 x 3 Snap:---------------------------2" x 3" x 0.050"
2 x 4 Snap:----------------------------- 2" x 4" x 0.045"
SELF MATING (SMB
2 x 4 SMB:------ ------------- 2" x 4" x 0.044" x 0.100"
2 x 5 SMB----------------------- 2" x 5" x 0.050" x 0.118"
2 x 6 SMB:-------- -------------
2" x 6" x 0.050" x 0.120"
2 x 7 SMB:--------------------
2" x 7" x 0.057" x 0.120"
2 x 8 SMB:------------------
2" x B"x 0.072" x 0.224"
2 x 9 SMB:--------------
2" x 9"x 0.072" x 0.224"
2 x 10 SMB:---------------- -
2" x 10" x 0.092" x 0.374"
:SCANNEiU
BY
St. Lucie ,W1�
Y20 201
FIL
RE WED FOR
CODE OMPLIANCE
ST. LUCIE COUNTY
i
I HEREBY CERTIFYTHAT INAVE REVIEWED
THIS PLAN AND FOUND ITT BE IN
COMPLIANCE WITH ASCE 7-1k AND FBC 6TH
EDITION RESIDENTIAL AND EXISTING
BUILDING
rpJ`GLT V
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Myron Max Neal
FLORIDA LICENSE NUMBER: 86663
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, 0.33542
Phone: (813)788-5314
Fax:1-(866)-824-7894
Email: erb@fbcplans.com
Website:v .tbcplans.com
C.O.A.- #29054
DATE: 09/29/2019 1
DRAWN BY: DENNIS W. DUNN
REVISION: DATE:
RO 1
RO 2
RO 3
RO 4
JOB # 19_0925_309
IOB NAME & ADDRESS:
TALL PINES: LOT 125
125 NORTH ERIE DRIVE
FORT PIERCE, FL 34946
CONTRACTOR:
B.A.C.H. LAND DEVELOPMENT
ENGINEERS
NOTES
h
,,f
PROPOSED
N X 4" CONCRETE
SIDEWALK
PROPOSED
4" CONCRETE SLAB
FOR DRIVEWAY
FACTORY
PORCH
PROPOSED
4" CONCRETE SLAB W/ FOOTER
FOR CARPORT (SEE DETAIL)
m �
8"
(1) 95 REBAR CONTINUOUS,
25" MIN. OVERLAP ALL JOINTS,
ON 3" HIGH CHAIRS
44'
MANUFACTURED HOME
PROPOSED
LINEOFSHED PROPOSED
4" CONCRETE SLAB W/ FOOTER
FOR SHED (SEE DETAIL)
FOUNDATION PLAN
CARPORT / COVERED PATIO FOOTER
GRADE
CONCRETE
BELOW GRADE
(2) 95 REBAR CONTINUOUS,
25" MN. OVERLAP ALL JOINTS,
ON 3" HIGH CHAIRS
SHED FOOTER
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITjl WCE¢ DFBC6TH
EDITION RE ''��ffAAq
BUILDINM-1 eI_T
® vOV° `� I •O �G
• O
o SIAT OF%
FNOV
ECEIVED ����1'��;�e`'��
��®1_CiBs/OW.t�' SN
0 4� 019 `��+' 411t0l"T
e County, Permitting PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
4, Myron Max Neal
FLORIDA LICENSE NUMBER: 86663
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
4" CONCRETE SLAB W/ FOOTER
FOR COVERED PATIO (SEE DETAIL)
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, B. 33542
Phone: (813)788-5314
Fax: 1-(866)-824-7894
Email: erb@fbcpbms.mm
Website:w Jbcplans.com
C.OA-#29054
I DATE: 09/29/2019 1
I DRAWN BY: DENNIS W. DUNN
I REVISION: I DATE: I
RO 1
RO 2
RO 3
RO 4
JOB # 19_0925_309
i0B NAME & ADDRESS:
TALL PINES: LOT 125
125 NORTH ERIE DRIVE
FORT PIERCE, FL 34946
CONTRACTOR:
B.A.C.H. LAND DEVELOPMENT
PLANS AND ELEVATIONS
1 OF 2
i
MFD.
HOME
3" X.030" ALUM. RISER PAN
ROOF FL 16952 OR EQUIV.
7 2X5 SMB
4" CONCRETE SLAB
W/FOOTER
0
FRONT ELEVATION
CARPORT
W/ SHED AND STEPS SHOWN BEYOND
3"X.030"ALUM. RISER PAN PLAN VIEW 2X4 WOOD FRAME
ROOF FL 16952 OR EQUIV. SHED W/ VINYL SIDING
0
QI[K6P *)UZIp ]:iRAATITAY&I-9I_1:1
20'
B'
PROPOSED
CARPORT
8'
PROPOSED PROPOSED
2X4 WOOD FRAME /('3" X .030" ALUM. RISER PAN
SHED W/ VINYL SIDING 1 ROOF FL 16952 OR EQUIV.
8'
SIDE ELEVATION
PROPOSED
OPOSED COVERED
SHED PATIO
4' CONC. SLAB
ONCRETE SLAB I W/FOOTER
W/FOOTER
10,
b
PROPOSED
3" X .030" ALUM. RISER PAN
ROOF FL 16952 OR EQUIV.
2X5 SMB �
4" CONCRETE SLAB
W/FOOTER
I HEREBY CERTIFY THAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10 AND FBC 6TH
EDITION RE$I®ENt1t44 1?FY TING
BUILD�IN%B 1.T ®ftJ ®�®
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Myron Max Neal
FLORIDA LICENSE NUMBER: 86663
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, 0. 33542
Phone:(813)788-5314
Fax: 1-(866)-824-7894
Email: erb@tbcplans.com
Website:w Jbcplans.com
C.OA.-#29054
DATE: 09/29/2019
DRAWN BY: DENNIS W. DUNN
REVISION: DATE:
RO 1
RO 2
RO 3
RO 4
MFD.
HOME JOB # 190925309
JOB NAME & ADDRESS:
TALL PINES: LOT 125
125 NORTH ERIE DRIVE
FORT PIERCE, FL 34946
CONTRACTOR:
B.A.C.H. LAND DEVELOPMENT
REAR ELEVATION
COVERED PATIO PLANS AND ELEVATIONS
W/ SHED AND STEPS SHOWN BEYOND 2 OF 2
EXISTING ROOF _
FASTEN 3" X 0.062" MIN. HEADER CHANNEL
TO MFG. HOST BEAM WITH 1/4"0 X 2-1/2" LAG
SCREW AT 24" O.C., 2 ROWS STAGGERED.
STRIP SEALANT BETWEEN FASCIAAND
HEADER CHANNEL
APPROX
ALUM. RISER PAN ROOF
2X END BEAM PER PLAN
RECOMMEND ALUMINUM FLASHING
INSTALLED UNDER DRIP EDGE
ALUMINUM FLASHING ATTACHED
W/ #8 X 3/4" TEK SCREW AND 1 "0
NEOPRENE WASHER AT EACH RIB
I LATTACH ALUM. RISER PAN ROOF TO 3" X 0.062"
FASTEN 1.112" X 2-1/8" X 1-1/2" X 0.062" I MIN. HEADER CHANNEL W/ (4) #12 X 3/4" TEK
RECEIVING CHANNEL TO MFG. HOST BEAM OR SCREW PER PAN (BOTTOM OR BACK OF PAN)
STRUCTURAL WALL MEMBER (2 STUDS MIN.) I o w
WITH 1/4"0 X 2" LAG SCREW LL p FASTEN END BEAM TO RECEIVING
(1 SCREW / 2 INCHES OF BEAM HEIGHT) I CHANNEL W/#10 X 3/4" TEK SCREW
I (1 SCREW / INCH OF BEAM HEIGHT)
MFG. HOST BEAM STAGGERED BOTH SIDES
ALUM. RISER PAN ROOF AND END BEAM
CONNECTION TO MFG. HOSI
FASTEN ALUMINUM PAN
ROOF W/ #12 TEK SCREW AND
1-1/4"0 NEOPRENE WASHER
4 PER PAN AT EDGE BEAM
AND 8" O.C. AT END BEAM
ALUMINUM RISER
PAN ROOF
2X4 END BEAM
1-1/2" X 2-1/8" X 1-1/2" X 0.062"J J�b �2X5 SMB
RECEIVING CHANNEL W/ (4) #10 X 3/4" pEDGEBEAM
TEKSCREWINTO EACH SIDEOF END a
BEAM AND (2) 318"0 BOLT, WASHER
AND NUT THRU POST AND EDGE BEAM
POST CONNECTIONS AT ALUMINUM PAN ROOF
FASTEN RECEIVING CHANNEL
TO SMB W/ #10 X 3/4" TEK SCREW
(1 SCREW / INCH OF BEAM HEIGHT)
STAGGERED, BOTH SIDES
2X SMB PER PLAN
FASTEN INTERNAL OR EXTERNAL
RECEIVING CHANNEL TO STRUCTURAL
WALL MEMBER WITH 1/4"0 X 2" LAG SCREW
(1 SCREW / 2 INCHES OF BEAM HEIGHT)
1-1/2" X 2-118" X 1-1/2" X 0.062"
INTERNAL OR EXTERNAL
RECEIVING CHANNEL
BEAM TO WOOD WALL CONNECTION
S.M.B.FDEPTHI S.M`B. B I TUBEALL�WALL I ^^'" CORROSION REESISTANT
UPLIFT
CAPACITY
I HEREBY CERTIFYTHAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE WITH ASCE 7-10 AND C6TF
EDITION RESIDFF��61��1I1�LII
��S BUILDING ��d`* V-To J0�
OGOp000.O
N, G� \L.I-N C % /
a �b J o° a ,
'Ir:
e
� • \ G YO
,720 LBS
,550 B
,500 LEIS®
.600 LBS
.500 Les
.500 LBS
,0O LBS
LB
IV
INOTE: OTHER BOLT SIZES AND Y BE USED PER
SITE SPECIFIC PLANS AND CALCULATED UPTIESLIFT CAPACITY REQUIRED \ I
# 12 X 3/4" TEK SCREW AND
1-1/4"0 NEOPRENE WASHER
4 PER PAN AT ALL BEAMS
AND B" O.C. AT RAKE
ALUMINUM RISER
PAN ROOF
2X SMB PER PLAN
(N) 3/8" THRU BOLTS, WASHERS,
AND NUTS, CORROSION RESISTANT,
TYPICAL (SEE CHART)
POST/COLUMN PER PLAN
ALUMINUM PAN ROOF, POST AND BEAM CONNECTION
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Myron Max Neal
FLORIDA LICENSE NUMBER: 86663
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER 77605
FBC Plans & Engineering
Services, Inc.
6272 Abbott Station Drive Unit 101
Zephyrhills, U. 33542
Phone:(813]788-S314
Fax: 1-(866]-824-7894
Email: erb@ibcplans.com
Website:w .f6cplans.com
C.OA.-#29054
TOP VIEW
DATE: 09/29/2019
(1) 112"0 LDT CONCRETE SCREW
NOTE:
DRAWN BY: DENNIS W. DUNN
WITH 2-3/4" EMBEDMENT
MINIMUM EMBEDMENT OF ANCHORS INTO
(MIN. EDGE DISTANCE 3")
CONCRETE FOOTING SHALL BE 2-3/4" AT ALL
REVISION:
DATE:
PER OUTER FLANGE
n'p
POST LOCATIONS. ALL SCREW LENGTHS AT
POST CONNECTIONS SHALL BE OF SUFFICIENT
RO 1
LENGTH FOR REQUIRED EMBEDMENT INTO
CONCRETE WHEN A PAVER DECK IS PRESENT.
RO 2
ALUM. SQUARE COLUMN /POST
RO 3
(2) 3/8"0 THRU BOLT, WASHER
AND NUT OR (4) #14 X 3/4" TEK
2" X 2" X 0.125" EXTERNAL (OPTION #1) OR
RO 4
SCREW EACH SIDE
I
INTERNAL (OPTION #2) EXTRUDED POST BASE
(1) 1/2"0 LDT CONCRETE SCREW
I
OPTION #2:
JOB # 19_0925_309
WITH 2-3/4" EMBEDMENT
FOR INTERNAL FASTENING (4) 318"0
JOB NAME & ADDRESS:
(MIN. EDGE DISTANCE 3")
CONCRETE SCREW WITH 2-3/4" EMBEDMENT
PER OUTER FLANGE
(MIN. EDGE DISTANCE 3" AND MIN. SPACING 2")
TALL PINES: LOT 125
125 NORTH ERIE DRIVE
.. _ _
. , _�_"•_ :. _ _ , _. _- _
FORT PIERCE, FL 34946
CONTRACTOR:
B.A.C.H. LAND DEVELOPMENT
ALUMINUM CARPORT
COVERED PATIO DETAILS
SIMPSON H2.5T OR EQUIV.
FASTENED PER MFGR'S SPE6S.
SIMPSON (2) H2.5T OR EQUIV.
FASTENED PER MFGR'S SPECS.
2X CRIPPLE STUD
A 16" O.C.
(N) 2X JACK STUD
PER TABLE
SIMPSON LSTA STRAP
OR EQUIV. FASTENED
APPROX. 4" ABOVE
AND BELOW HEADER
PER MFGR'S SPECS.
2X CONTINUOUS STUD
2X SILL PLATE
ATTACH JACK STUD
TO CONTINUOUS STUD
W/ 16d NAILS AT 24" O.C.
STAGGERED
2X CRIPPLE STUD
AT 16" O.C.
2X WALL STUD
AT 16" O.C.
2X P.T. BASE PLATE
INSTALL WINDOWS AND DOORS
IN OPENINGS PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
WINDOW
OPENING
TABLE
HEADER
SIZE
SPAN
JACK
STUDS
(2) 2"x4„
4'4"
1
(2) 2"x6"
6'4-
1
(2) 2"X8"
8,-0"
2
(2) 2"xl0"
R-6"
2
(2) 2"x12"
11'-6"
2
DBL. HEADERS WITH 112" PLYWOOD SPACER,
GLUED AND NAILED W/ 16d NAILS AT 24" O.C.
(2 ROWS STAGGERED)
DBL 2X
TOP PLATE
DBL. 2X HEADER WITH
112" PLYWOOD SPACER
PER TABLE
1/2"0 WEDGE ANCHOR WITH
STANDARD WASHER, 12" FROM
CORNERS, 6" FROM OPENINGS AND
24" O.C. WITH 4" MIN. EMBEDMENT AND
1-3/4" MIN. EDGE DISTANCE TYPICAL
PRODUCTAPPROVAL CODECHART�
STRUCTURAL COMPONENTS
1 SIMPSON DSP/SSP FL10456 1
ALL CONNECTORS AND FASTENERS IN
CONTACT W/ TREATED WOOD SHALL BE
ZINC COATED GALVANIZED STEEL OR
SIMPSON'ZMAX'
SIMPSON H4 OR EQUIV.
FASTENED PER MFGR'S SPECS.
rrDBL. 2X HEADER WITH ((('''
1112" PLYWOOD SPACER
I PER TABLE
DOOR
OPENING
SIMPSON DSP, SSP, SPH OR EQUIV.
FASTENED PER MFGR'S SPECS.
ILL'WILCel7i7Zi77�►11Re��l�wrr:r:L : �
SIMPSON SP2 OR H2.5T
OR EQUIV. FASTENED
PER MFGR'S SPECS.
ALL WOOD STUDS
AND BLOCKING FOR
WALLS SHALL BE 2X4
FASTEN ALUMINUM RISER PAN ROOF
TO TOP PLATE WITH #12 X 1-1/2" TEK
SCREW WITH 3/4"0 NEOPRENE WASHER,
4 PER PAN AT ENDS AND 8" O.C. AT RAKE
WITH 1-112" EMBEDMENT MIN.
DBL 2X TOP PLATE (ONLY NON -TREATED —
WOOD IN CONTACT W/ ALUMINUM ROOF OR
PROVIDE IMPERVIOUS MOISTURE BARRIER) -
DBL 2X HEADER WITH 1/2" PLYWOOD
SPACER OVER WINDOWS AND DOORS.
SEE HEADER TABLE
INSTALL WINDOWS PER MFGR'S—
INSTALLATION INSTRUCTIONS
1/2" PLYWOOD OR OSB SHEATHING SHALL
OVERLAP BOTTOM AND TOP PLATES. COVER
WITH APPROVED WEATHER RESISTANT
BARRIER SUCH AS A POLYETHLYLENE
HOUSE WRAP PER MFG'S SPECS.
VINYL SIDING OF CHOICE APPLIED
PER MFGR'S SPECIFICATIONS
2X WOOD STUDS AT 16" O.C.
2X P.T. BASE PLATE
112"0 WEDGE ANCHOR WITH STANDARD
WASHER, 12" FROM CORNERS, 6" FROM
OPENINGS AND 24" O.C. WITH 4" MIN.
EMBEDMENT AND 1-3/4" MIN. EDGE
DISTANCE TYPICAL
PER R318.7
CONCRETE BELOW
GRADE PER R403.1
[�7 iiF]Fil
NOTE:
VINYL SIDING MUST BE INSTALLED OVER
A MINMUM 7116" WOOD STRUCTURAL
PANEL SHEATHING (PLYWOOD OR OSB)
WITH AN APPROVED WEATHER RESISTIVE
BARRIER PLACED UNDER SIDING
2X BLOCKING FOR PANEL SPLICE WHERE
WALL HEIGHT EXCEEDS PANEL LENGTH
WALL PANELS (PLYWOOD) NAILING NOTE:
NAL Bd NAILS 6" O.C. AT EDGES AND 12" O.C. IN
FIELD. ROWS OF NAILS SHALL BE 1/2" MIN. FROM
PANEL EDGES. PLYWOOD SHEATHING SHALL
OVERLAP BOTH TOP AND BOTTOM PLATES. ALL
FASTENERS NAILED PER MANUFACTURERS
SPECIFICATIONS.
WHEN SHEATHING PANELS ARE CONTINUOUS FROM
TOP TO BOTTOM PLATE (8' OR LESS) SIMPSON STUD
PLATE TIES ARE REQUIRED ONLY AT THE CORNERS
AND EACH SIDE OF OPENINGS AND SHEATHING IS
NAILED PER PANEL NAILING NOTE.
WHEN SHEATHING PANELS ARE NOT CONTINUOUS,
SIMPSON STUD PLATE TIES ARE REQUIRED AT
ALL STUDS.
OR H4
4"2500 PSI CONCRETE SLAB WITH
- -fI'''`•"''6%`"ter ti.•: 6"X6"#10 WWM(OR FIBERMESH)
GRADE
�i. • •, �. r OVER 6 MIL. POLY VAPOR BARRIER
:F`•: ; �' ' W/ EDGES LAPPED 6" AND SEAMS
TAPED, OVER CLEAN, COMPACTED,
.. TERMITE TREATED SOIL.
SIMPSON SP1 OR H4 c'
OR EQUIV. FASTENED 2 95 REBAR CONTINUOUS,
PER MFGR'S SPECS. 25" MIN. OVERLAP ALL JOINTS,
ON 3" HIGH CHAIRS 12"
FOOTING WIDTH AND DEPTH SIZE AS PER R403.1 AND B1809.4
WALL SECTION / DETAILS
I HEREBY CERTIFYTHAT I HAVE REVIEWED
THIS PLAN AND FOUND IT TO BE IN
COMPLIANCE W{'1 *$Cff'i-Q AND FBC 6TH
BU
LG9P969TOpp
p .o
PROFESSIONAL ENGINEER SEAL
ENGINEER OF RECORD
David W. Smith P.E.
FLORIDA LICENSE NUMBER: 53608
Thomas L. Hanson P.E.
FLORIDA LICENSE NUMBER: 38654
Myron Max Neal
FLORIDA LICENSE NUMBER: 86663
Joel Falardeau P.E.
FLORIDA LICENSE NUMBER: 70667
Erik Stuart P.E.
FLORIDA LICENSE NUMBER: 77605
FBC Plans & Engineering
Services, Inc.
6272 AbbottStation Drive Unit 101
Zephyrhills, 0. 33542
Phone:(813)788-5314
Fax: 1-(866)-824-7894
Email: erb@fbcplans.com
Website:w .fbcplansxom
C.OA - #29054
DATE: 09/29/2019 I
I DRAWN BY: DENNIS W. DUNN I
I REVISION: I DATE: -
RO 1
RO 2
RO 3
RO 4
JOB # 19_0926_309
JOB NAME &ADDRESS:
TALL PINES: LOT 125
125 NORTH ERIE DRIVE
FORT PIERCE, FL 34946
CONTRACTOR:
B.A.C.H. LAND DEVELOPMENT
WOOD FRAME SHED
DETAILS