HomeMy WebLinkAboutSOIL REPORTHeadquarters 11345 U.S. Highway 1 Sebastian, FLc 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: fiias �f7 Yi ANDITEBT-III 611lu to�'vo / SOIL COMPACTION REPORT IA P ASTM D 1557 and ASTM D 2922 December 31, 2019 ROVB Inc. 5009 Paleo Pines Circle Ft. Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 200009-1d/SH/ct JAN 0 6 nN S-r. Lucle C ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. S.W. 0" - 12" 40 109.9 111.6 98.5% 2. Center 40 109.6 98.2% 3. N.E. 39 108.1 96.9% 113.0 W E I I I I I Soil Description: Brown Sand with Shell I G 112.0 I I I I I I I I I I H I In Place Moisture: T—,.1..—..� 111.0 I I I I 10.3% P Optimum Moisture: 11.0% 110.0—.._.i_ Max. Dry Density: P.C.F. F I I I I I 111.6 I I I D 109.0 y.._...t..—..1 @ Test Locations The I Density & Penetrometer R Y I I I I I I I I I I I Readings Indicate the 108.0 ••—•;—••—••—••—?•—••�••—••T••—••; Degree of Compaction Meets 8 9 10 11 12 13 14 Minimum Required for Unstaked Foundation Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990