HomeMy WebLinkAboutPLANSNOV 0 7 5T. Lucie 0 �O rM Irl 0o00 0M9 00-0 O i N= 1 0 M A � -AII construction shall comma with Florida Building Code 6th edition 2017. 1 ULTIMATE WIND SPEED: 150 Zone 1 +/-19.47 NOMINAL WIND SPEED: 116 Zone 2 +/- 29.96 WIND EXPOSURE CATEGORY: B Zone 3 +/- 41.63 RISK CATEGORY 1 NON HABITABLE WIND PRESSURE ON COMPONENTS AND CLADDING PROFESSIONAL SERVICES BY DRISCOLL ENGINEERING,INC. PO BOX 357577. GAINESVILLE, FL 32635 PH (352)331-1513 CA 8690 PLANS AND SPECIFICATIONS The plans and speclfications presented herein are applicable only forthe anticipated construction at the locations shown. If construction plans change, the Design Professional should be notified so the plans and specifications can be reevaluated. The Design Professional should be given the opportunity to review final plans and spectleaffons to see if the Intent of the plans and specifications has been followed and/or if supplemental details and recommendations are needed. The Design Professional warrants that the plans and specifications contained herein, have been prepared In accordance with generally accepted professional engineering pracdce. No otherwarentles are implied or expressed. CORPORATE PROTECTION It Is understood and agreed that the Design Professional's Basic Servloes under this Agreement do not Include project observation or review of the Contractor's performance or any other construction phase services, and that such services will be provided by the Client The Client assumes all responsibility for interpretation of the contradtorpocuments and for construction observation and supervision and walves any claims against the Design Professional that may be in anyway connected thereto. In addition, the Client agrees, to the fullest extent permitted by law. to Indemnify and hold the Design Professional harmless from any loss, claim or cost. Including reasonable attorneys fees and costs of defense, arising or resulting from the performance of such services by other person or entities and from any and all claims arising from modifications, cladficatians, Interpretations, adjustments or changes made to Contract Documents to reflect changed field or other conditions, except for claims arising from the sole negligence or willful misconduct to the Design Professional. OWNERSHIP OF INSTRUMENTS OF SERVICE AII reports, plans, specifications, computer files, field data, notes and other documents and Instmmems prepared by the Design Professional as Instruments of service shall remain the property of the Design Professional. The Design Professional shall retain all common law, statutory and other reserved rights, including the copyright thereto. DEFECTS IN SERVICE The Client shall promptly report to the Design Professional any defects or suspected defects In the Design Professionals work or services of which the Client becomes aware, so that the Design Professional may take measures to minimize the consequences of such a defect. The Client warrants that he or she will Impose a similar notification requirement on all contractors In his or her CIIenUContractor contract and shall require all subcontractors at any level to contain a like requirement Failure by the Client and the Client's contractors or subcontractors to notify the Design Professional, shall relieve the Design Pmfessional of the costs of remedying the defects above the sum such remedy would have cost had prompt notification been given. VERIFICATION OF EXISTING CONDITIONS Inasmuch as the remodeling and/or rehabilitation of anmisting building requires that certain assumptions be made regarding existing conditions, and because some of these assumptions may not bevedfiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the Client agrees, to the fullest extent parnifled by few, to indemnify and hold the Design Pmfessional harmless from any claim, liability or cost Qncluding reasonable attorneys fees and costs of defense) for Injury or economic loss arising or allegedly arising out of the professional services provided under this AgeemeA excepting only those damages, llabilifes, or costs abibutable to the sole negligence or willful misconduct of the Design Professional INTERNAL PRESSURE COEFFICIENT Gcpi= +/- 0.0 DESIGN PRESSURE PER FBC CHAPTER 16, INCLUDING ASCE 7-16 LOAD CALCULATIONS ROOF LIVE LOAD =12 PSF ROOF DEAD LOAD = 2.5 PSF MIN SOIL BEARING 2500 PSF TRUSS BEARING LOAD EACH END 1800LB TRUSS UPLIFT @ POST 1800LBS 1. Wood framing and fasteners to meet NDS-2012 requirements. 2. Fastener requirements: (1) All nails are Common galvanized; (2) all bolts are to be galvanized steel and include nuts and washersand (3) all other hardware (Simpson, etc.) is to be installed according to manufacturer's specifications and recommendations. Nailing (size and number) shall satisfy Tables 2306.2.(1), 2306.3.(1) and 2306.3.(#) FBC unless otherwise indicated. Note: fasteners exposed to the weather are to be treated for weather resistance and compatible with the type of pressure treated wood used (connectors, nails, bolts, nuts and washers). Concrete Construction Notes 1. Concrete work shall conform to "Building Code Requirements for Reinforced Concrete" (ACI-318) and "Specifications for Structural Concrete" (ACI-301), Latest Edition. 2. Concrete mix shall conform to the following specifications. All concrete mixes shall contain a water -reducing admixture conforming to ASTM C-494. Air -entraining admixture shall conform M C-260. CONCRETE MIX A \� EDWARD i Ultimate Compressive Strength @ 28 days 3,000 PSI i _ No.4Slump Range' 4" +/-1" " 3922 Maximum Aggregate Size Entrained Air None FAT oy�✓,�� Dry Weight per Cubic Foot 150 # 3. Shotcrete mix 4 All concrete shall be cured for a minimum of 28 days. If forms for vertical surtaces are re rri 19,1 e end of the curing period, spray surfaces with liquid membrane curing compound. 5. Reinforcing steel shall conform to ASTM A615, Grade 40 (Fy=40 ksi). Lap continuous bars for tension lap splice per ACI-318, unless otherwise noted. Provide corner bars of same size and, spacing as horizontal wall reinforcement. Cover for concrete reinforcing steel shall be in accordance with ACI-318, Paragraph 7.7. 6. Welded wire fabric (WWF) shall conform to ASTM A185. Lap sheets two mesh spaces and wire tie adjacent sheets together securely. Cut alternate reinforcement at control joints. 7. All slabs on grade shall have construction or control joints not to exceed 15' - 0" spacing, unless otherwise noted. 8. Electrical conduit and other pipes to be embedded in structural concrete floor slabs or walls shall be placed in accordance with the requirements of ACI-318, Paragraph 6.3. SCANNED BY St. Lucie County 36' x 36' OPEN POLE STORAGE STRUCTURE Micha19 Michael E Driscoll PE FL Reg # 43922 E 8"x 8" pt post 24" dia. x 48" deep post footing (typ) � r STEEL ROOF TRUSES IL ROOF PLAN VIEW //11110 10-11-19 Michael E Driscoll PE FL Reg # 43922 CO a a u') N W m Q0] 0 Z J OLL LLI LLww IL �(L Cn U)LOU- i �s z w n -gg w Z� u u ffN Z Z w� s uz a o Vg n 2"x 6" #2 syp purlins @ 24" Drip edge attach in accord w/ mfr 29 ga. metal roofing attach in accord'with mfr. specifications F— Galy ridge cap CI 3 0999 ADA 4 a 0- u< ma mm uvus nut & washers RIDGE CONNECTION DETAIL 29 ga. metal roofing attach in accord with mfr. specification: FL # 9555.4R4 2-1/2" dia. carriage thru bolts nut & washer to match 11'-4" 14 Ga purlin 2"x 6" #2 syp :onnectcr purlins attach to angle w/ 4 #10 lag screws Truss details (see sheet 5) PURLIN CONNECTION DETAIL purlins @ 24" max spacing FGalv ridge cap 112 t/'���t 31 29 ga. metal roofing attach in accord with mfr. specifications FL # 9555.4R4� 2"x 6" #2 syp purlins @ 24" max spacing 2-1/2" dia. carriage thm bolt: nut & washer to match See sheet 2 &3 - for post & footing sizes iss details oe sheet 5) Min 3000psi D. D concrete Q m� #5 X 12" BARS CENTERED EACH WAY FOR 18"DIA HOLES USE 12" LONG BARS FOR 24" DIA HOLES USE 18" LONG BARS (TYP) D D 4" (TYP) 80# BAG SACRETE MIN_ J OR 24" SQ X 4" THICK CONCRETE PAD POST FOOTING TO TRUSS DETAIL NTS 12 �1 1 2-1/2" dia. carriage thm bolts LTruss dta (see sheetl5) nut & washer to match 72-1/2"dia,.age thru bolt match + 0 —See sheet 2 &3 N _ for post & footing ,I sizes 10'-9" 11'-4" \O0 4' (0 \ NAL END ELEVATION Micha eU> e al 19 l Michael E Driscoll PE NTS FL Reg # 43922 a Q (e to W N W Qm l] ZJ OLL W 11' aWW �a u) U) LLLL No. ELEMENT MATERIAL (50 KSI) DESCRIPTION M1 Collar Tie ASTM 513 L1-1/2"x 1-1/2" x 3/16" 2 Collar 'e ASTM 513 "x 1-1/2" x 3/16" M3 To Chord ASTM 513 L1-1/2"x 1-1/2" x 3/16" n n n -- 5 Center , � n M6 End Vertical ASTM 513 L 1-1/2"x 1-1/2" x 3/16" M7 Bearing angle ASTM 513 L 1-1/2"x 1-1/2" x 3/16" M8 Inside vertical ASTM 513 L1-1/4"x 1-1/4" x 1/8" M9 Diagonal web 1ASTM 513 1 L1-1/4"x 1-1/4" x 1/8" STEEL TRUSS CROSS SECTION NOTES: STEEL TRUSS CROSS SECTION 1-MATERIALS SHALL CONFORM TO STEEL ASTM 513. CONNECTOR SCHEDULE 2'x5'#2 syp pudin to 5'x5' x 149a. clip 4410x1-1/4-lagscrews Truss to truss @ ddge 3- 1/7 die th,u bolts & nut Wood post to truss. 212' diet that bolts nut & washers Past to mnmte 24' diet x48' deep w/ 2 #5 bars thru post 2— 1 /2- DIA. CARRIAGE BOLTS NUT & WAS ----- 2- ALL STEEL SHALL BE 50ksi IN ACCORD WITH CURRENT AISC MANUAL. STEEL 3- WELDING ELECTRODES TYPE E70XX 4-ALL WELDING SHALL BE IN ACCORD WITH CURRENT AWWA REQUIREMENTS. 5-ALL WELDING SHALL BE DONE BY A CERTIFIED WELDER. 6-BOLTS SHALL BE ASTM A325. W/ NUTS & WASHERS. (TYP) 7- WELD STRENGTH 70 KSI MIN. 8- ALL POST SHALL BE PRESSURE TREATED GROUND CONTACT. 9- PRIMING & PAINTING SHALL BE DONE BY TRUSS MANUFACTURER. 10- MIN EDGE DISTANCE FOR BOLTS HOLES SHALL BE 3/4" MIN 11-MAX TRUSS SPACING SHALL NOT EXCEED 12'-0" 12-THE DESIGNER DISCLAMS ANY RESPONSIBILITY FOR DAMAGES AS A RESULT OF POOR WORKMANSHIP, OR IMPROPER USE, AND ACCEPTS NO RESPONSIBILTY OR EXERCISES NO CONTROL WITH REGUARD TO FABRICATION, HANDLING,AND INSTALLATION OF TRUSSES. 14 CL/pg' PURL/N TRUSS TO POST DETAIL PLAN VIEW Jolts shpost not for clary show \ll l I I Il / EDWARp • �\CEIIIS� 'Qjs�/�/ No.43922 % , OF c� I� K ON L 10-11-19 Michael E Driscoll PE FL Reg # 43922 TRUSS DETAILS