Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
I i FORM R405-2017 ,,i`fLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HAYES RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: TREETOPTRAIL SCANNE® Permit Office: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, 34951 BY Permit Number. Owner. ANN MARIE HAYES StLucie County Jurisdiction: ST LUCIE COUNTY . Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2090.7 sgft.) Insulation Area 2. Single family or multiple family Single family a. Concrete Block- Ext Insul, Exterior R=4.1 1717.30 ft- b. Frame - Wood, Adjacent R=11.0 373.33 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= fla 10. Ceiling Types (1842.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1842.00 ft' 6. Condtioned floor area above grade (W) 1842 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= fl' 11. Ducts R ft- 7. Windows(248.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U-Factor. Sgl, U=0.58 168.001`? SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.60 80.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 35.2 SEER:16.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.261 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: SO gallons 8. Floor Types (1842.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1842.00 ft' b. Conservation features b. N/A R= ft' None c. NIA R= ft' 15. Credits None Total Proposed Modified Loads: 65.48 Glass/Floor Area: 0.135 PASS Total Baseline Loads: 65.95 1 hereby certify that the plans and specifications covered by Review of the plans and QTfiE STAT this calculation are in compliance with the Florida Energy specifications covered by this _IV Code. calculation indicates compliance with the Florida Energy Code. rift„ PREPAR Y• DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 rj -4 A • ° o- I hereby certify that this buildin s designed, is in compliance with the Florida Energy Code. Florida Statutes. It yS COD WE OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). PILE COPY 12/5/2019 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HAYES RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1842 Lot # Owner Name: ANN MARIE HAYES Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBoolc Builder Name: DAVE GOLDEN HOMES Rotate Angle: 0 Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1842 17155.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 CLST 2 24 247.7 No 0 1 Yes Yes Yes 2 BEDROOM 2 149 1395.7 No 0 1 1 Yes Yes Yes 3 BATH 2 51 474.3 No 0 1 Yes Yes Yes 4 CLST 3 24 223.2 No 0 1 Yes Yes Yes 5 BEDROOM 3 149 1385.7 No 0 1 1 Yes Yes Yes 6 HALL 20 186 No 0 1 No Yes Yes 7 LIVING/FOYER AR 464 4315.2 No 0 1 Yes Yes Yes 8 LAUNDRYRM 105 1004.4 No 0 1 Yes Yes Yes 9 KITCHEN 180 1674 Yes 0 1 No Yes Yes 10 DINING RM 169 1571.7 No 0 1 Yes Yes Yes 11 STORAGE 16 148.8 No 0 1 No Yes Yes 12 M WIC 56 520.8 No 0 1 No Yes Yes 13 M BATH 80 744 No 0 1 Yes Yes Yes 14 MASTER BEDROO 336 3124.8 No 0 1 1 Yes Yes Yes 15 M HALL 16 148.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge insulation CLST 2 14 ft 0 24 ft- — 1 0 0 2SIab-On-Grade Edge Insulation BEDROOM 2 13 ft 0 149 ft- — 1 0 0 3SIab-On-Grade Edge Insulation BATH 2 5 ft 0 51 ft' — 1 0 0 12/5/2019 2:25 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 4SIab-On-Grade Edge Insulation CLST 3 14 ft 0 24 ft2 — 1 0 0 58Iab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 149 ft2 — 1 0 0 6Siab-On-Grade Edge Insulation HALL 1 ft 0 20 ft2 — 1 0 0 7SIab-On-Grade Edge Insulation LIVING/FOYER A 34 ft 0 464 ft2 — 1 0 0 8SIab-On-Grade Edge Insulation LAUNDRY RM 12 ft 0 108 ft- — 1 0 0 9SIab-On-Grade Edge Insulation KITCHEN 1ft 0 180 ft2 1 0 0 10SIab-On-Grade Edge Insulation DINING RM 27ft 0 169 ft- -- 1 0 0 11Slab-On-Grade Edge Insulation STORAGE t ft 0 16 R2 _— 1 0 0 12SIab-On-Grade Edge Insulation M WIC 1 ft 0 56 ft2 -- 1 0 0 13SIab-On-Grade Edge Insulation M BATH aft 0 80 ft2 — 1 0 0 1431ab-On-Grade Edge Insulation MASTER BEDRO 44 ft 0 336 ft2 — 1 0 0 1:SIab-On-Grade Edge Insulation M HALL 1 ft 0 16 ft2 __ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2050 ft2 0 ft2 Light N 0.4 No 0.9 No 20 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1842 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) CLST 2 0 Bloom 24 ft- 0.1 Wood 2 Under Attic (Unvented) BEDROOM 0 Blown 149W 0.1 Wood 3 Under Attic (Unvented) BATH 2 0 Blown 51 ft- 0.1 Wood _ 4 Under Attic(Unvented) CLST3 0 Blown 24 ft- 0.1 Wood 5 Under Attic (Unvented) BEDROOM 0 Blown 149 ft2 0.1 Wood _ 6 Under Attic (Unvented) HALL 0 Blown 20 ft- 0.1 Wood 7 Under Attic (Unvented) LIVING/FOYERA 0 Blown 464 ft- 0.1 Wood 8 Under Attic (Unvented) LAUNDRYRM 0 Blown 108 ft� 0.1 Wood _ 9 Under Attic (Unvented) KITCHEN 0 Blown 180 ft- 0.1 Wood 10 Under Attic (Unvented) DINING RM 0 Blown 169 ft- 0.1 Wood _ 11 Under Attic (Unvented) STORAGE 0 Blown 16 ft- 0.1 Wood 12 Under Attic (Unvented) MWIC 0 - Blown 56 ft2 0.1 Wood 13 Under Attic(Unvented) MBATH 0 Blown 80 ftz 0.1 Wood _ 14 Under Attic (Unvented) MASTERBEDRO 0 Blown 336ft2 0.1 Wood 115 Under Attic (Unvented) M HALL 0 Blown 16 ft2 0.1 Wood I 12/5/2019 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 S Exterior Concrete Block- Ext Insul CLST 2 4.1 12 0 9 4 112.0 W 0 0 0.4 0 _ 2 E Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.4 0 3 E Exterior Concrete Block- Ext Insd3EDROOM 2 4.1 13 0 9 4 121.3 ft2 0 0 0.4 0 4 S Exterior Concrete Block- Ext Insul BATH 2 4.1 5 0 9 4 46.7 ft2 0 0 0.4 0 _ 5 S Exterior Concrete Block- Ext Insul CLST 3 4.1 12 0 9 4 112.0 ft2 0 0 0.4 0 6 W Exterior Concrete Block- Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.4 0 _ 7 W Exterior Concrete Block- Ext InsiBEDROOM 3 4.1 13 C 9 4 121.3 ft2 0 0 0.4 0 _ 8 E Exterior Concrete Block- Ext InsLIVING/FOYE 4.1 13 0 9 4 121.3 ft' 0 0 0.4 0 9 N Exterior Concrete Block- Ed InstaVING/FOYE 4.1 5 0 9 4 46.7 ft2 0 0 0.4 0 _ 10 W Exterior Concrete Block - Ext Ins4IVING/FOYE 4.1 16 0 9 4 149.3 R2 0 0 0.4 0 _ 11 W Exterior Concrete Block- Ext InsdIAUN DRY R 4.1 12 0 9 4 112.0 ft2 0 0 0.4 0 12 N Garage Frame - Wood LAUNDRYR 11 9 0 9 4 84.0 ft2 0 0.25 0.4 0 13 N Garage Frame -Wood KITCHEN 11 10 0 9 4 93.3 ft2 0 0.25 0.4 0 _ 14 S Exterior Concrete Block- Ext InsuDINING RM 4.1 12 0 9 4 112.0 ft2 0 0 0.4 0 15 E Exterior Concrete Block -Ext lnsuDINING RM 4.1 15 0 9 4 140.0 ft2 0 0 0.4 0 16 W Garage Frame -Wood STORAGE 11 4 0 9 4 37.3 ft2 0 0.25 0.4 0 17 W Garage Frame - Wood MWIC 11 7 0 9 4 65.3 ft2 0 0.25 0.4 0 _ 18 N Exterior Concrete Block- Ext Insul M BATH 4.1 8 0 9 4 74.7 ft- 0 0 0.4 0 _ 19 W Garage Frame - Wood M BATH 11 10 0 9 4 93.3 ft2 0 0.25 0.4 0 _ 20 S Exterior Concrete Block- Ed InsdNASTER BE 4.1 7 0 9 4 65.3 ft2 0 0 0.4 0 21 E Exterior Concrete Block- Ext InsdMASTER BE 4.1 21 0 9 4 196.0 ft2 0 0 0.4 0 22 N Exterior Concrete Block- Ext InsdM.4STER BE 4.1 16 0 9 4 149.3 ft2 0 0 0.4 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt 10 Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 E 3 Vinyl Low-E Single Yes 0.58 0.24 N 15.0 ft2 1 ft 4 in 0 ft 5 in None None 2 W 7 Vinyl Low-E Single Yes 0.58 0.24 N 15.0 ft2 7 ft 4 in 0 ft 5 in None None 3 E 8 Vinyl Low-E Single Yes 0.6 0.24 N 40.0 ft2 16 ft 4 in 0 ft 5 in None None 4 W 10 Vinyl Low-E Single Yes 0.58 0.24 N 15.0 ft2 7 ft 4 in 0 ft5 in None None 5 W 10 Vinyl Low-E Single Yes 0.6 0.24 N 40.0 fN 7ft41n 0ft5in None None 6 W 11 Vinyl Low-E Single Yes 0.58 0.24 N 10.0 ft2 1 ft 4 In 0 It 5 in None None 7 S 14 Vinyl Low-E Single Yes 0.58 0.24 N 30.0 ft2 16 ft 4 in 0 It 5 in None None 8 E 15 Vinyl Low-E Single Yes 0.58 0.24 N 30.0 ft2 1 ft 4 in 0 ft 51n None None _ 9 E 21 Vinyl Low-E Single Yes 0.58 0.24 N 30.0 ft2 1 ft 4 in 0 It 5 in None None _ 10 N 22 Vinyl Low-E Single Yes 0.58 0.24 N 15.0 ft2 1 R 41n 0 ft 5 in None None _ 11 N 18 Vinyl Low-E Single Yes 0.58 0.24 N 4.0 ft2 1 It 4 In 0 ft5 in None None 12 S 4 Vinyl Low-E Single Yes 0.58 0.24 N 4.0 ft2 1 ft4 in 0 ft 5 in None None 12/5/2019 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft- 483 W 40 It 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2001.4 109.88 206.64 .1525 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Single SEER: 16 35.2 kBtu(hr 1056 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume REF None None ft' DUCTS # —Supply--- Location R-Value Area — Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 150 ft- Attic 15 ft' Default Leakage Attic (Default) c(Default) c 1 1 12J512019 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Coollng an� [rX,] Venting Jan Feb Mar[ Mar Apr rI May May JuntrXr Jun Jul Jul [[ ]] [TX]�Sep f r[X'] r[X�]Dec Decec [ ] [ [ ] lXl Aug [ ] Sep Oct [X] Nov [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 so 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 so 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thiclmess Furniture Fraction Space Default(8 lbs/sq.ft. Off 0 ft 0.3 CLST 2 Defau@(8lbs/sq.ft. IF ft 0.3 BEDROOM 2 Defauft(81bs/sq.ft. fR ft 0.3 BATH 2 Default(8 lbs/sq.ft. fF ft 0.3 CLST 3 Defauft(S Its/sq.ft. ft' ft 0.3 BEDROOM 3 Defauft(S lbs/sq.ft. ft- ft 0.3 HALL Defauft(8 lbs/sq.ft. fF ft 0.3 LIVING/FOYER AR Defaut](8 lbs/sq.ft. ft' ft 0.3 LAUNDRYRM Defauft(S lbs/sq.ft. ft. ft 0.3 KITCHEN Defauft(S Ibs/sq.ft. ft- ft 0.3 DINING RM Defauh(8 lbs/sq.ft. ft' ft 0.3 STORAGE Default(8 lbs/sq.ft. fP It 0.3 M WIC Defauft(8lbs/sq.ft. ft= ft 0.3 M BATH Defauft(8lbs/sq.ft. ft' ft 0.3 MASTER BEDROO Default 8lbs/s .ft. ft. ft 0.3 M HALL 12/5/2019 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HAYES RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: TREETOPTRAIL Permit Office: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Y Owner. r. ANN MARIE HAYES Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the botto to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures Installed in the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor a drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1215/20192:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lowerthe Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1842 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.586 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 c) Area 7c. 248.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 0.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be ins led (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be complete sed onjnstallecj code compliant features. Builder Date: /z Xi Address of New Home: TREE TOP TRAIL City/FL Zip: FORT PIERCE, FL 34951 12/512019 2:25:52 PM EnergyGaugeg) USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft° Project Summary Enure House QUICK CALCS, INC. 317 ST LUCIE LAPS, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fez 772-4666796 Emil: QUCKCALCS@AOLCOM Prouect Information Job: Date: DEC. 5, 2019 By: For: TREETRTPEREL49RESIDENCE TRAI,FbICCF351 SCANNED Notes: BY St. Lucie Courlt4 Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22959 Btuh Structure 18308 Btuh Ducts 5678 Btuh Ducts 8138 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humiidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28637 Btuh Use manufacturer's data n Rate/swing multiplier Equipmerlf load 0.95 25124 Infiltration sensible Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3885 Btuh Ducts 2200 Btuh Central vent (0 cfm) 0 Btuh Heat' Cool ingg (none) Area (ft') 1842 1842 Equipment latent load 6086 Btuh Volume (ft3) 17131 17131 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 31209 Btuh Equiv. AVF (cfm) 108 57 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6036J1 AHRI ref Coil TEM4AOC37S31++TDR AHRI ref 201763705 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.8 kW Sensible cooling 24640 Btuh Heating output 26765 Btuh Latent cooling 10560 Stuh Temperature rise 21 OF Total cooling 35200 Btuh Actual airflow 1173 cfm Actual airflow 1173 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 FILE COPY Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w= IL It 4 ft 2019-Dec-05 14:13:42 ••^�^�+ Right-Sulte® Unlvemal 2019 19.0.08 RSU06101 Page 1 ...s\Wnghtsoit WACUWYES RES-TREETOP TRAIL mp Calc=M.B FmntDoorlaces: W wrightsofi• Right-J® Worksheet Entire House QUICK CALCS, INC. ,: , 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-468-6796 Email: QUICKCALCS@AOL.COM Job: Date: DEC. 5, 2019 By: 1 Room reme Entire House CLST 2 2 Exposed wall 182.0 0 14.0 ft 3 Room height 9.3 R 9.3 It heaticod 4 5 Room dimensions Room creel 1842.0 ftz 2.0 x 12.0 it 24.0 fF Ty Construction Ll-value Or Hint Area OF) Lead Area ft Lcad number (BtuMfWF) (FlLddft2) or perimeter (ft) (&uh) or pedrtleter (ft) (Duh) Heat Ccol Gross WP/S Heat Cool Gross WP/S Heat Cool 6 1RJ �C 13A4ocs 2 glazing, cir Iovv-s 13AA. 0.143 0.580 0.143 n n a 4.W 16.24 4.00 2.19 13.73 2.19 270 15 586 255 0 470 1020 244 1882 557 205 1029 0 0 19 0 0 19 0 0 74 0 0 41 W 11 2 glazirg, cir lower 2 glazing, cir love 0.580 0.600 a a 16.24 16.80 29.31 30.26 75 41 10 4 1218 685 2199 1235 0 0 0 0 0 0 0 0 IM T-G 13A4ocs 2 glazing, dr love 13A-0acs 0.143 0.580 0.143 s s w 4.00 16.24 4.00 2.19 13,73 2.19 446 30 391 416 30 310 1657 417 1240 911 412 678 112 0 0 112 0 0 447 0 0 244 0 0 W 2 glazing, dr low-e 2 glazing, clr low-e 0.580 0.580 w w la24 16.24 25.64 29.31 10 30 3 4 162 487 256 879 0 0 0 0 0 0 0 0 C 2 clazim. dr lwre 16X19&rxI 0.600 0.403 w - 16.80 1.59 3026 1.37 41 1842 4 1842 685 2921 1235 2520 0 24 0 24 0 38 0 33 F 22A4ph 1.358 - 38.02 0.00 1842 182 6920 0 24 14 Son 0 6 c)AEDexcursion 0 -13 Envelope loss/gain 19620 12116 1092 304 12 a) Infiltration 3339 941 267 72 b) Ronmventilation 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 0 0 AppItanceslother 5250 0 Subtotal (tines 6 to 13) 22959 18308 1349 377 Less extend load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -1349 -377 14 Subtotal 22959 18308 0 0 16 Duct loads 25% 449/. %78 8138 250/6 44% 0 0 Trial room load I I 2SM7 26446 0 0 Air required (rim) 1173 1173 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,c -F}F wri9hivoT!- 2019-Dec-0514:13:42 Right-SUHe® Univemal 2019 19.0.08 RSLJO8101 Page 1 ...slWrightsoft WAC%HAYES RES-TREETOP TRA I-rup Calc = MJ8 Front Door faces: W wrightsoft' RighWO Worksheet Entire House QUICK CALCS, INC. :, 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: DEC. 5, 2019 By: 1 Room name BEDROOM 2 BATH 2 2 rhgx5ed wall 12.0 ft 5.0 it 3 Room height 9.3 R heat/cod 9.3 R hint/cool 4 5 Room dimensions Room area 12.0 x 12.0 ft 144.0 ft2 10.0 x 5.0 ft 50.0 ft2 Ty Construction number U-value (Btuh/fIMF) Or HTM (BtuWft2) Area or perinneter (ft) two (Bluh) Aw or perit�er (ft) Load (Bluh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 1rt! �G 13A4ocs 2 glazing, cir love 13A4acs 0.143 0.580 0.143 n n a 4.00 16.24 4.00 2.19 13.73 2.19 0 0 112 0 0 97 0 0 397 0 0 211 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, dr Iowe 2 glazing, dr love 0.580 0.600 a a 16.24 16.80 29.31 30.26 15 0 2 0 244 0 440 0 0 0 0 0 0 0 0 0 Y-f' 13A4ocs 2 glazing; dr love 13A-4xs 0.143 0.580 0.580 s s w 4.00 16.24 2.19 13.73 2.19 0 0 0 0 - 0 0 -0 0 0 0 0 0 47 0 0 47 0 0 186 0 0 102 0 0 lTl 2 glazing, dr Io 2 glazing, dr lowe 0.580 0.580 w w 6.24 16.24 16.24 29.31 29.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 2 glazing, dr Iw 16X190nd- - 0.600 0.408 w - 16.80 1.59 3.0.26 1.37 0 144 0 144 0 228 0 197 0 50 0 50 0 79 0 68 F 22A4ph 1.358 - 38,02 0.00 144 12 456 0 50 5 19D 0 6 o)AED excursion .5 -7 Envelope losslgain 1315 813 456 164 12 a) Infiltration 220 62 92 26 b) Rmmvenntilation 0 0 0 0 13 Internet gains: Occupants @ 230 0 0 0 0 Appliances/other 325 0 Subtotal (lines 6 to 13) 1535 1200 547 189 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redislributon 1163 329 394 115 14 Subtotal 2698 1529 941 3W 15 Duct lceds 26% 44% 667 660 25% 44% 233 135 Total room load 1 1 3311 2219 1174 440 Air required (drn) 138 98 48 20 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlghisoR- 2019-Dec-0514:13:42 AZIN RightSuite@ Universal 2019 19.0.08 RSU08101 Page 2 ...s\Wrightsoft M/AC\HAYES RES- TREETOP TRAIL.rup Calc=MJB Front Doorfaces: W wrightsoft Right-J® Worksheet Job: Entire House Date: DEC. 5, 2019 QUICK CALCS, INC. By: ;1 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772-466-6796 Email: OUICKCALOSQAOL.00M 1 Room name, CLST 3 BEDROOM 3 2 Expmed wall 14.0 It 12.0 0 3 Room height 9.3 ft heat/cod 9.3 ft heal/cool 4 Room dimensions 2.0 x 12.0 It 12.0 x 12.0 ft 5 Room area 24.0 fF 144.0 W Ty Construction LLvalue Or HTM Area number (Btul✓fWF) (Btuwft2) or perimeter(ft) (Eluh) or peder (ft) (Btuh) Heat Cool Gross WP/S Heal Cool Gross WP/S Heat Cool 6 W, 13A4ocs 0.143 It 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr lc a 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 W 13A4ccs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.680 a 16.24 29.31 0 0 0 0 0 0 0 0 11 2 glazing, dr lcwe 0.600 a 16.80 30.26 0 0 0 0 0 0 0 0 l4! 1344ccs 0.143 a 4.00 2.19 112 112 447 244 0 0 0 0 I-G 2 glazing, cir lc a 0.580 s 16.24 , 13.73 0 0 0 0 0 0 0 0 IN 13A4ocs 0.143 w 4.00 2.19 19 19 74 41 112 97 387 211 2 glazing, cir lave 0.580 w 16.24 25.64 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.580 w 16.24 29.31 0 0 0 0 15 2 244 440 III--GGG 2 alaziml cir to v-e 0.600 w 16.80 30.26 0 0 0 0 0 0 0 0 C 16X1941oed- - 0.408 - 1.59 1.37 24 24 38 33 144 144 223 197 F 22A4ph 1.358 - 38.02 0.00 24 14 Sm 0 144 12 455 0 61 a)AED excursion 1 1 -13 179 Envelope losstgain 1092 304 1315 1027 12 a) Infiltration 257 72 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 125 Subtotal (tines 6 to 13) 1349 377 1535 1214 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1349 -377 1163 329 14 Subtotal 0 0 2W8 1543 15 Dud loads 25% 449/6 0 0 25% 44% 667 686 Tdd rcom load 0 0 3365 2229 Air required (dm) 0 0 138 99 Calculations approved by ACCA to meet all requirements of Manual J Bth Ed. c -Fw wrlghtsof't- 2019-Dec-0514A3:42 RightSuile® Universal 2019 19.0.08 RSU08101 Page 3 ...s\Wrightsoft FMAC\HAYES RES- TREE TOP TRAIL.rup Cale =MJB Front Door faces: W wrightsofi° Right-J@ Worksheet Entire House QUICK CALCS, INC. 1 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUCKCALCS@AOL.COM Job: Date: DEC. 5, 2019 By: 1 Room nacre HALL LMNG/FOYERAREA 2 Exposed wall 0 ft 34.0 ft 3 Room height 9.3 0 heal/cod 9.3 it heat/cod 4 Room dine r ions 4.0 x 5.0 it 16.0 x 29.0 ft 5 Room area 20.0 fF 464.0 it - Ty Constnction U-value Or FITIA Area OF) Load Area (w) Load number (BtulUfY-°F) (BIUWft2) or pedneter qt) (Btuh) or perimeter (it) (Btuh) Heat I Cool Gross WINS Heat Ccol G. WP/S Heat Cool 6 1fN 13A-4d:s 0.143 n 4.00 2.19 0 0 0 0 47 47 186 102 t-C 2 glazing, dr lav-e 0.580 n: 16.24 13.73 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 121 80 321 175 2 glazing, dr Iowa 0.580 a 16.24 29.31 0 0 0 0 0 0 0 0 11 2 glazing, dr low-e 0.600 a 16.80 30.26 0 0 0 0 41 4 685 1235 l4V 134-4ocs 0.143 s 400 2.19 0 0 0 0 0 0 0 0 L-G 2 glazing, dr lows, 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 W 13A4acs 0.143 w 4.00 2.19 0 0 0 0 149 93 372 203 I--G 2glazing, dr love 0.58D w 16.24 25.64 0 0 0 0 0 0 0 0 2 glazing, dr loa-e 0.58D w 16.24 29.31 0 0 0 0 15 2 244 440 2 olazina. dr lave 0.600 w 16.80 30.26 0 0 0 0 41 4 685 1235 C 16X194)rrd 0.408 - 1.59 1.37 20 20 32 27 464 464 736 635 F 22A4ph 1.358 - 38.02 0.00 20 0 0 0 464 34 1293 0 6 c)AED excursion -1 81 Envelope loss/gain 32 26 4522 4106 12 a) Infiltration 0 0 624 176 b) Roomvedilation 0 0 0 0 13 Inlemal gains: Occupants @ 230 0 0 a 0 Appliancestother 0 500 Subtotal (tines 6 to 13) 1 32 26 5146 4781 Less edennal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution S2 -26 9 7 14 Subtotal 0 0 5155 4789 15 Duct loads 2594. 44% 0 0 25% 449% 1275 2129 Trial mom load 0 0 6430 6918 Air required (dm) 0 0 263 307 Calculations approved by AC CA to meet all requirements of Manual J 8th Ed. ,C -§JA- wr19F+boit- 2019-Dec-0514:13:42 '-' RlghtSufte® Universal 2019 19.0.08 RSLID8101 Page 4 ...s\Wrghtsoft HJAMRAYES RES- TREETOP TRAILrup Catc=MJ8 Front Doorfaces: W wrightsoft* Right-M Worksheet Job: Entire House Date: DEC. 5, zo,s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name LAUNDRYRM IOTCHEN 2 Exposed wall in 0 0 0 3 Room height 9.3 0 heat/cool 9.3 ft heat/cool 4 Room dimensions 12.0 x 9.0 0 12.0 x 15.0 ft 5 Room ales, 108.0 fP 180.0 fP Ty Construction U-value or HTM Area (111) Load Area (IF) Load number (Btuh/ft? °F) or pedmeter of) (Btuh) or perimeter (0) (Btuh) Heal Cool Gross WPM Heat Cool Gross WP/S Heat Cool 6 ,W 1344acs 0.143 in400 - 2.19 0 0 0 0 0 0- 0 0 2 gluing, cir Iwwe 0.5W n 16.24 13.73 0 0 0 0 0 0 0 0 13A-0acs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, dr Iovr-e 0.680 a 16.24 29.31 0 0 0 0 0 0 0 0 11 2 glazing, cir love 0.600 a Vx80 30.26 0 0 0 0 0 0 0 0 lM 134-4acs 0.143 s 4.00 2.19 0 0 _ 0 0 0 0 0 0 l---G 2 glazing, cir Iwr-e 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 NN,,11 13A4ccs 0.143 w 4.00 2.19 112 102 407 222 0 0 0 0 F---G 2 glazing, cir lave 0.580 w 16.24 25.64 10 3 162 256 0 0 0 0 2 glazing, cir Iw✓-e 0.580 w 1624 29.31 0 0 0 0 0 0 0 0 I�-GG 2 glazinn, cir lovv-e O.600 w 16.80 30.26 0 0 0 0 0 0 0 0 C 16X190rtd - 0.408 - 1.59 - 1.37 108 108 171 148 180 180 285 246 F 22A4ph 1.358 - 3302 0.00 108 12 455 0 180 0 0 0 6 c)AED excursion 135 -80 Envelope loss/gain 1197 762 285 167 12 a) Infiltration 220 62 0 0 b) Roomvemilation 0 0 0 0 13 Internal gains: Occupants (a1 230 0 0 0 0 Appliancestother 0 2100 Subtotal(Ones 6to 13) 1417 824 285 2257 Less eldennal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 2 1 14 Subtotal 1417 824 287 2268 15 Dud leads 25% 44% 350 366 25% 44% 71 1008 Tole] room load 1767 1190 358 3276 Air required (don) 72 53 15 145 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr19F+tzsotFe- 2019-Dec-0514:13:42 A�k"' '^^ Right -Suite® Universal 2019 19.0.08 RS1A610f Page 5 ...s\Wnghtsoft FNA0HAYES RES- TREE TOP TRAILmp Cale =MJB Front Door faces: W wrightsofC Right-J® Worksheet Job: Entire House Date: DEC. 5, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUCKCALCS(o)AOL.COM 1 Room name DINING RM STORAGE 2 3 Egxsedwall Room height 27.0 It 9.3 ft healfcool 0 e 9.3 It heatfcod 4 5 Room dimensions Room area 15.0 x 12.0 It 180.0 (t2 4.0 x 4.0 R 16.0 ft2 Ty construction U-value Or HTM Area M Load Area (fl2) Load number (Btuh/Wp) (&uh/ft) or perimeter (it) Multi) or perimeter (ft) (Muh) Heat Cool Gross WP/S Heat Cool Gross WPfS Heat Cool 6 IN LG 13A-0ccs 2 glazing, dr trove 1ap, a. 0.143 0.580 0.143 n n a 4.00 16.24 4.00 2.19 13.73 2.19 0 0 140 a 0 110 0 0. 438 0 0 - 240 0 0 0 0 0 0 0 0 0 0 0 0 - W 11 2 glazing, clr lcxe 2glazing, drlowe 0.580 0.600 a a 16.24 16.80 29.31 30.26 30 0 4 0 4a7 0 879 0 0 0 0 0 0 0 0 0 VN I G 13A-4ws 2glazing, dr lcve 13A-4ws 0.143 0.5805 0.143 s w 4.00 16.24 4.00 2.19 13,73 2.19 112 30 0 82 30 0 327 487 0 179 412 a 0 00 0 0 0 0 _ 0 0 0 0 0 t(V �L�--GGG 2 glazing, drlow-e 2 glazing, cir trn 0.580 0.580 w w 16.24 1R24 25.64 29.31 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 C F 2 olazirra dr lowe 16X19-0md 22A4ph 0.6W _ 0.408 1.358 w - - 16.80 1.59 38.02 30.26 1.37 0.00 0 180 180 0 180 27 0 285 1027 0 246 0 0 16 16 0 16 0 0 25 0 0 22 0 6 c)AED excursion -81 -1 Envelope loss/gain 3052 1875 25 21 12 a) Infiltration 495 140 0 0 b) Rmmvemilation 0 0 0 0 13 Internal gains: Occupants (dy 230 0 0 0 0 App6ances/other 300 0 Subtotal (lines 6 to 13) 3547 2314 25 21 Less codemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 4 6 5 14 Subtotal 3552 2318 32 26 15 Duct loads 2591. 44% 878 1030 26% M% 8 12 Trial room load 4430 3349 40 38 Air required (cfm) 181 149 2 2 Calculations approved byACCA to meet all requirements of Manual J eth Ed. wrl9htsolR- 2019-Dec-0514:13:42 ,ZUA RlghtSulte® Univemal2019 19.0.08 RSLID8101 Page 6 ...s\WrightsoR M/ACIH4VES RES- TREETOP TRAIL.mp Calc=MJe Front Dooncces: W wrightsoft' Right-J® Worksheet Job: Entire House Date: DEC. 5, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax T72-466-6796 Email: ONCKCALCWOLCOM 1 Room reme M WIC M BATH 2 Egmsed wan 0 ft 8.0 0 3 Room height 9.3 it heal/cool 9.3 ft heat/cool 4 5 Room dimensions Room area 7.0 x 8.0 ft 56.0 fP 10.0 x 8.0 ft 80.0 fF Ty Construction number U-value (Btuh/fWF) Or HTM (Bluwft) Area (02) or perimeter qt) Load (Bluh) Area (82) or perimeter qt) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gros WP/S Heat C001 6 VN �C 13A400s 2 glazing, clr lov" 13AAccs 0.143 0.580 0.143 n n. a 4.00 16.24 4.00 2.19 13.73 2.19 0 0 0 0 0 0 0 0 0 0 (1 0 74 0 0 74 0 0 298 0 0 163 0 0 w 11 2 glazirg, or Iowa 2 glazing, cir Iowa 0.680 0.600 a a 16.24 16.80 29.31 30.26 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V1J T-C 1344ccs 2 glazing, dr lowe 13A-0ws 0.143 0.580 0.143 s s w 4.00 16.24 4.00 2.19 13.73 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Ti 2 glazing, dr lave 2 glazing, drlowe 0.580 0.580 w w 16.24 16.24 2. 29.31 31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 2 di cIr lcw a 1SX190nd 0.600 0.408 w - 16.80 1.59 30.26 1.37 0 56 0 56 0 89 0 77 0 80 0 80 0 127 0 109 F 22A4ph 1.358 - 38.02 0.00 56 0 0 0 80 8 304 0 61 c)AED excursion 1 -20 1 1 -28 Envelope bsstgain 89 57 729 245 12 a) Infiltration 0 0 147 41 b) Room ventilatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appnameslother 500 500 Subtotal (tines 6 to 13) 89 557 876 7 66 Les external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 5 0 0 14 Subtotal 95 562 876 786 15 Duct loads 25% 44% 24 250 25% 44% 217 349 Total room Icatl 119 812 1092 1135 Air required(dm) 5 36 45 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -"*- wrl9F+tsoTi- 2019-Dec-0514:13:42 �A Right-9ulteO Unlverse12019 19.0,08 RSU08101 Page 7 ...slWrightsoft HUACIHAYES RES- TREE 70P TRAIL. rup Calo=MJB Front Doorfeces: W wrightsoft• Right-M Worksheet Job: Entire House Date: DEC. 5, 2019 BY: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34945 Phone: 772466-6799 Fax 772466-6796 Email: OUCKCALCS@AOL.COM 1 Room name MASTER BEDROOM M HALL 2 5gmsed wall 44.0 it 0 it 3 Room height 9.3 0 heat/coU 9.3 it heaVocd 4 5 Room dimensions Room area 21.0 x 16.0 ft 336.0 ft' 4.0 x 4.0 ft 16.0 fF Ty Construction U-value Or HTM Area (t Lead Area(02) Load number (BtuhfftMF) (Bluh/ftT) or pedneter (0) (Ruh) or perimeter (it) (Stuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 %t13A-4acs 2 glazing, dr love 13A4ccs 0.143 0.580 0.143 n in a 4.00 16.24 4.00 2.19 13.73 2.19 149 15 195 134 0 165 536 244 662 293 206 362 0 0 0 0 0 0 0 0 0 0 0 0 -C w 11 2 glazing, dr lore 2glazing, cir Io 0.5W 0.600 a a 16.24 16.80 29.31 30.26 30 0 4 0 487 0 879 0 0 0 0 0 0 0 0 0 1p/ I-C W .13AAces, 2 glazirg, cIr 1. 13A-0acs 0.143 0.580 0.5w s s w 4.00 16,24 4.00 2.19 13,73 65 0 0 65 0 0 261 0 0 142 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ILL-GCG 2 glazing, dr lowe 2 glazing, Ur Iorv� 0.580 0.580 w w tfi24 16.24 5.19 29.31 29.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 2 alazin9. clr love 16X19-0md 0.600 0.408 w - 16.80 -1.59 30.26 1.37 0 336 0 336 0 533 0 46D 0 16 0 16 0 25 0 22 F M41ph 1.358 - 38.02 0.00 336 44 1673 0 16 0 0 0 6 c)AfD excursion -118 -1 Envelope Ioss(gain 4395 2224 25 21 12 a) Infiltration 807 228 0 0 b) Rcomventilalion 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appflanceslother 900 0 Subtotal (lines 6 to 13) 5202 3352 25 21 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 5 -25 -21 14 Subtotal 5208 3357 0 0 15 Duct loads 25% 4486 12BB 1492 25% 44% 0 0 Trial room load 6496 4" 0 0 Air required(dm) 2665 215 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FWwrnglilsoftt- 2019-Deo-0514:13:42 Aam. =A """' RightSufte® Universal 2019 19.0.08 RSLID8101 Page 8 ...s\Wrightsoft FMAC\HAVES RES-TREETOP TRAIL.rop Celc = MJS Front Door faces: W -�+ wrightsoft= Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM Project• • For. HAYES RESIDENCE, DAVE GOLDEN HOMES TREE TOP TRAIL, FORT PIERCE, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm Job: Date: DEC. 6, 2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm 182 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1174 48 20 1.000 5.0 Ox0 VIFx 42.6 135.0 st3 BEDROOM h 3365 138 98 1.000 7.0 Ox0 VIFx 42.7 135.0 st3 BEDROOM h 3365 138 99 1.000 7.0 Ox0 VIFx 46.2 135.0 st3 DINING RM h 4430 181 149 1.000 8.0 0x0 VIFx 20.3 115.0 st2 KITCHEN c 3276 15 145 1.000 8.0 Ox0 VIFx 13.6 115.0 st2 LAUNDRY RM h 1767 72 53 1.000 6.0 Ox0 VIFx 17.5 115.0 st2 LIVING/FOYER AREA c 3459 132 153 1.000 8.0 Ox0 VIFx 44.0 135.0 st3 LIVING/FOYER AREA -A c 3459 132 153 1.000 8.0 Ox0 VIFx 47.4 135.0 st3 M BATH c 1135 45 50 1.000 6.0 Ox0 VIFx 11.7 115.0 st1 MwIC c 812 5 36 1.000 5.0 Ox0 VIFx 11.7 115.0 st1 MASTER BEDROOM h 3248 133 108 1.000 7.0 Ox0 VIFx 14.8 115.0 st1 MASTER BEDROOM -A h 3248 133 108 1.000 7.0 Ox0 VIFx 14.0 115.0 st1 STORAGE c 38 2 2 1.000 4.0 Ox0 VIFx 17.1 115.0 st1 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 Peak AVF 317 303 1.000 718 9.0 0 x 0 VinlFlx st2 Peak AVF 856 870 1.000 814 14.0 0 x 0 VinlFlx st3 Peak AVF 587 523 1.000 748 12.0 0 x 0 VinlFlx st2 t wrightsoft- 2019-Dec-0514:13:43 •••••• » �•.-+ Right-Sultet Universal 2019 19.0.08 RSU08101 Page i ..' Wrightsoft HVAC%H4YES RES- TREETOP TRAIL.rup Calc = MJB Front Door faces: W Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO 1173 1173 0 0 0 0 Ox 0 VIFx wrlghtsoft• 2019-Dec-0514:13:43 C •—.-. RlghtSuite® UnWersal 2019 19.. 008 RSUD8101 ". Page 2 ,,,a\WrightsghtaoR HVACIHAYE3 Res. TREE TOP TRAILrvp Dole =MJB Front Door faces: W APPLICANT'S NAME: IVIAOT Giy-/� 7 GU ITO/c�r-ir LEGAL DESCRIPTION: Parez y�/ 141 -•214 - �`!�� en,9© ^ I certify that there are no potable private wells within 75 feet of the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated building foundation, that there ace no public wells that serve less than 25 people or less than 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the water meter or well to the structure is at least 10 feet from the available area for the proposed septic system unless the plans show the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right-of-way that abuts the property, that there are no lakes, streams, wetlands, or, surface water within 75 feet of the available area for the proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest from surface water, that all private wells, septic systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot.. The natural grade elevation in the area of the proposed septic system and the benchmark must be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGn9EER. dots forms:'septis S,,plic,%pppPag,:207 CERTIFIEDBY: ` /'/GS FLORIDA P OFE IONAL NO.: DATE: JOB NO.: