Loading...
HomeMy WebLinkAboutMISC EMAILLydia Galbraith From: Planreview Sent: Wednesday, April 01, 2020 1:50 PM To: Lydia Galbraith Subject: FW: Landry Tie -In Survey Attachments: Landry Tie- In.pdf SCANNED St Lucie (;o From: Tyler Lowe [mailto:tylerpbg@gmail.comj Sent: Wednesday, April01, 20201:03 PM To: Planreview <planreview@stlucieco.org> Subject: Landry Tie -In Survey SECURITY WARNING: This email originated from outside the County systems. Please show caution when clicking links or opening attachments unless you recognize the sender and know the content is safe. Questions, call Customer Service at 772-462-2146. Permit #- 1911-0193 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection. examination and l or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal Inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. I Nutting ia Engineers of Florida Inc. i Established 1967 Your Project is Our Commitment 1310 Neptune. Drive Boynton Beach, Florida 33426 561-736-4900 1 Toll Free: 877-NUTTING (688-8464 { .Far, 561-737-9975 Broward 954-.941-8700 i St Lucie 772-408-1050 Miami-Dade305-557-3083 i www.n9ttingenylneers.com March 11, 2020 Pools by Greg 8886 South Federal Highway Port St. Lucie, Florida 34952 SCANNED Re Pool Backfill Evaluation By Landry Residence St. Lude COUnt, 5514 Spruce Drive Fort Pierce, FL Permit No.: 19110193 Gentlemen: Nutting Engineers of Florida, Inc. has performed geotechnical engineering services for the referenced project. The area between the house and the proposed pool was probed with a Static Cone Penetrometer to determine the level of compaction of the backfill material. Three probes were performed at the following locations: 1) Northeast end of pool. 2) Northwest end of pool by spa 3) South end of pool by steps. It is our opinion that the pool backfill as indicated by the above test locations has been compacted to a density of the order of 95 percent modified Proctor. o, cor c 0 v c m a this opportunity to be of service. -Should you have any questions, please- - Wet your convenience. INC.