EVALUATION REPORT FLORIDA BUILDING CODE, C EDITION
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
(800) 438-7465
www.owenscoming.com
Manufacturing Location:
Brentwood, NH
SCANNED
Houston, TX
BY
Quality Assurance:
UL LLC (QUA9625)
St. Lucie County
SCOPE
Category:
Roofing
Subcategory:
Undedayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Ent!
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI.042-02-01REV2
ASTM D 1970
2015
PRI Construction Matedals Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Matedals Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970 ,
2015
PRI Construction Matedals Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296.02-02
ICC-ES AC 188'
2012
[CC -ES AC 48
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction Matedals Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Matedals Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320.02-01
ASTM G 155
2005a
PRI Construction Matedals Technologies (TST5878)
OCF-321-02-01
'ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Matedals Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and II
OCR14002.8a FL9777-R11 Pace 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing lee & Water Barriers
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underayment constructed from SBS
(Brentwood, NH) mo ' ed asphalt, a fiberglass mat reinforcement and surfaced with granules. The
produ 's supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock G is permitted to be used as prescribed in FB ection 1507.1.1 for
mechanically atta d roofing coverings. Exposure on the r eck shall be limited to a
maximum 30 days.
WeatherLock® Mat WeatherLock@ Mat is an A D 1970 self -ad ive underayment constructed from
(Brentwood, NH or SBS modified asphalt with a fibs ass mat rei rcement. The product Is supplied in 1-
Houston, 7X) sq. rolls with nominal dimensions o x 3 . -ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted t9,6e used 11Vrescribed in FBC Section 1507.1.1 for
mechanically attached roof covorrings. Exposur n the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal
WeatherLock@ Metal ' an ASTM D 1970 self-adhesive u dayment constructed from
(Brentwood, NH)
SBS modified asp t with a fiberglass mat reinforcement an astic film surface. The
product is sup ' d In 2.0 sq. rolls with nominal dimensions of 3-ft x .7-ft.
Weather ck@ Metal is permitted to be used as prescribed in FBC Sectio 1507.1.1 for
mac ically attached roof coverings. Exposure on the roof deck shall be limited to a
m mum 90 days.
WeatherLock@
WeatherLock@ Specialty Tile & Metal Is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, W
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete file roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND"" Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with day or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
Weather r�L o G (High Tear) is a self -adhered, undedm ayment used as an eatve to
Tear)
ASTM D 226Type4-c a II roofing felt and ASTM D 1970 self -a ' g polymer
(Houston, 7X)
modified bitumen underia en . nderla ment is co�pa of SBS modified
y
asphalt with a fiberglass mat internal rein o rims surfaced with granules. The
product is supplied with a nominal thickn 50 nominal
dimensions of 3-ft x 65-ft.
=prescdbed
WeatherLock@ G (High r) is permitted to ben FBC Section
1507.1.1 for mecha ' y attached roof coverings. Exposure on the roof deck shall be
limited to a maxinflum 30 days.
FL9777-R11
2 of
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All underfayments shall be installed In accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning Installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed finely
into place to ensure complete contact with the deck. The underlayment shall be Installed
with the roll length parallel to the save, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 Inches across the width
of the lap.
It is permissible to back nail the underayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Undedavment Svstem No.1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturers installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-Inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
FL9777-RlI
3of4
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The undedayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underiayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed In this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
If
2017.10.1
No 74021
09:06:29
-04'00'
9 : STATE OF : 4tJ
'�0XN .• c P : ���`
Zachary R. Priest, P.E.
Organization 21
No. A E9641
E��`%`,
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest In any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any other entity involved In the approval process of the
product.
END OF REPORT
OCR14002.8a
i nis evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.