Loading...
HomeMy WebLinkAboutNOAMIMI M DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE Ludowici Roof Tile, Inc. 4757 Tile Plant Road New Lexington, 01143764 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy SCANNED BY St. Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: `Spanish' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 12-0904.18 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 17-0719.08 Expiration Date: OW1123 Approval Date: 10/12/17 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Clay 1. SCOPE This approves a roofing system using Ludowici `Spanish' Clay Roof Tile, as manufactured Ludowici Roof Tile, Inc. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Ludowici Spanish ASTM C 1167 High profile, interlocking, one piece, `S' shaped, Roof Tile vitrified clay roof tile equipped with two nail holes. For direct deck or battened, nail -on, mortar set or adhesive set applications. Trim Pieces 1= varies ASTM C 1167 Accessory trim, clay roof pieces for use at hips, w = varies rakes, ridges and valley terminations. Manufactured varying thickness for each tile profile. 2. 1 PRODUCT DESCRIPTION 1. New Lexington, OH. 2.2 SUBMITTED EVIDENCE: Test Aeencv Test Identifier Test Name/Revort Date IBA Consultants, Inc. 2376-282 ASTM C 1167 Sept 2007 The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. 94-084 PA 101 (Adhesive Set) May 1994 (Mortar Set) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-77 PA 100 The Center for Applied 25-7200-1 Static Uplift Testing Feb. 1995 Engineering, Inc. PA 102 (Screws, Battens) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix H PA 108 (Nail -On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & 102(A) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) NOA No.: 17-0719.08 MIAMI•D;UNTY Expiration Date: 01/31/23 Approval Date: 10/12/17 Page 2 of 7 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies P0647-01 Wind Tunnel Testing Aug. 1994 PA 108 (Mortar Set) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 PA 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, hie. Calculations 25-7094 February 1996 25-7496 April 1996 Walker Engineering, hie. Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, hie. Calculations 25-7183 March 1995 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 3. LIlVIITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. MIAMI•DADE COUNTY .... p NOA No.: 17-0719.08 Expiration Date: 01/31/23 Approval Date: 10/12/17 Page 3 of 7 4. INSTALLATION 4.1 Ludowici `Spanish' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight-W (lbf) Length-1(ft) Width-w (ft) Ludowici Spanish Tile 5.00 1.10 0.81 Ludowici Spanish Tile 7.02 1.50 0.81 Table 2: Aerodynamic Multipliers - 2, (ft') Tile Profile X (ft3) Batten Application 2, (ft') Direct Deck Application Ludowici Spanish Tile 0.228 0.247 NOA No.: 17-0719.08 Expiration Date: O1/31/23 Approval Date: 10/12/17 Page 4 of 7 Table 3: Restoring Moments due to Gravity - Mg (ft-lbf) Tile Profile 3":12" 4":12" 5":12" VAX' 7":12" or greater Ludowici Spanish Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck BattensX2.5 Battens Direct Deck 1 2.51 2.73 2.48 2.70 2.42 2.63 2.36 2.90 2.50 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Ludowici Spanish Tile 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 48 Screw 20.7 20.7 18.1 2 48 Screws 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 2-10d Ring Shank Nails' 33.1 48.1 45.2 ii Installation with a 4" the headlap and fasterners are located a min. of 2'/" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Ludowici Spanish Tile Adhesive 29.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 10.7 grams. 3MTm 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams. NOA No.: 17-0719.08 Expiration Date: Ol/31/23 Approval Date: 10/12/17 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Ludowici Spanish Tile WWI 2-Component Foam Roof Tile Adhesive AH-160 66.54 3MT11 2-Component Foam Roof Tile Adhesive AH-160 38.75 4 Large paddy placement of 63 rams of AH-160 5 Medium paddy placement of 24 rams of AH-160 Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Ludowici Spanish Tile Mortar Set 24.5 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". LUDOWICI ASTM C1167 GRADE I IDENTIFICATION MARK FOR SPANISH CLAY ROOF TILE (LOCATED ON UNDERSIDE OF TILE) 6. BuILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0719.08 Expiration Date: 01/31/23 Approval Date: 10/12/17 Page 6 of 7 V_6.. 1 22' -� RIGHTSIDE 9 3l4" SECTION "A -A" LUDOWICI SPANISH TILE END OF THIS ACCEPTANCE NOA No.: 17-0719.08 Expiration Date: 01/31/23 Approval Date: 10/12/17 Page 7 of 7