HomeMy WebLinkAboutPLAN VIEW",
��>'� ,' 't°'3T. " f;",..P.�C .,, YBeath $7 Ric Area '
F�F�,�
4 a L . i.x r"� i Y "w1� x §X4, a"Z a .tv § a
�� x :u5
y f` eY f xx" aid, x AA't t 4 a h t" f C
'f 11v S'•' 1 i } 'LA 't t fj. s °ry
4 e
i s ne x ti 3 .n KS?i e e r r.
A k- 1 fl 1 t
Y1-4
1' L r/f� J vyy Al Y µ V C
f � x iL � i •1. L 4 f' 1i
3� x y '� S l{ 1 x^� s} ) r rt�Pferce Shorez s
,� da x& -: x A q7 i4 .q, t 1
p. 1 m r.: Fart Pler&oxr ri n" r a . q
, eb4 r � k � i,�"�s NIEi SfeiC S 3 L � t m � �. •- �' '
# ' t
3 . t
Ce € ! x
1 0 161 X 30'
MOORING AREA
I
I 76
110+I
I><
—r
91
91
of
x
M�
m
DI
Z
2I
m�
119'
lAo�
MANGROVES �~
.1 1i
20't
UPLAND
— ^ RAMP
WILDCAT COVE
WATERBODY WIDTH
720't
COVERED PLATFORNI
rG
e—
ES
r l l
(NOT ENCLOSED)
I
PROPOSEC�
76't X 14't
BOAT LIFT
Y OTHERS)
I
I,
I
19
I�
A
I°x
I�
I�
I�
IZ
IZ
Im
I
I
I
I
I
I
I
I
I
I
I
APPROXIMATE
MEAN HIGH WATER LINE
CONSERVATION EASEMENT REVIEWED FOR
`(INCLUDES 16'UPLAND BUFFER)
I CODE COMPLIANCE
SHORELINE LENGTH
NGTH ST. LUCIE COUNTY
52t L.F. 1 //�aa 6J
T - - - - - - - - - - Aft
BOOV
'**NOTES***
Mt
UUFY
- PROPOSED WORK IS TO 796 SQ. FT. DOCK (INCLUDES UPLAND ACCESS) AND INSTALL A BOAT LIFT (BOAT LIFT BY OTHERS)
MEETCONSTRUCTAFB
-DECK DESIGN LOADS TO MEET 2017 FBC:
WIND LOAD AS PER ANSUASCE 7-10 SPEED =170 MPH
EXPOSURE = D
IMPORTANCE FACTOR =1.0
SCANNED 0'
10, 20'
'- DOCK PILES 8"0 MARINE PILES - MIN. PENETRATION 8' INTO RIVER BOTTOM AND T INTO FIRM SOIL FOR UPLANDS
'JR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
B 1
Y
-ALL MOORING PILES AND BOAT LIFT PILES 10.0 (OR GREATER) MARINE PILES —MIN. PENETRATION 8' INTO RIVER BOTTOM St.
Lucie County GRAPHIC SCALE
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
-ALL ROOF PILES 10"0 MARINE PILES —MIN. PENETRATION 10' INTO RIVER BOTTOM
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
- ROPE HANDRAIL TO BE INSTALLED ALONG 110' OF ACCESS (LOCATION OF ROPE HANDRAIL SHOWN IN SHEET 4)
I
1?s Environmental
Services, Inc.
1901 SWYellowtail Avenue
Port Saint Lucie, FL 34953
OVERALL DOCK PLAN VIEW
Robert Harper Jr.
1908 Lynx Dive
Fort Pierce, Florida
PCN# 1425-620-0028-000-4
Paul Welch, Inc.
1984 SW Biltmore Street, #114
Port St. Lucie, FL 34984
OCT 2 8 2019
Paul Welch, PE No. 29945
Phone: 772-215-3997 Fax: 772-879-4520
www.dlsenvironmentalservices.com
V=20'
OCT 2019
SHEET N OF 4
10' O.C.
(TYP.)
TYPICAL DOCK ACCESS PLAN VIEW DETAIL
SCALE 1" = 2'
0
5'
P.T CROSS -TIE
)VE DECK
PILES
P.T. DECKING
ACING BETWEEN
OARDS
STRINGERS
iS THRU BOLT
_R PILE
2' X 8' P.T. RAIL
2" X 6" P.T. TOP RAIL ATTACHED
WITH (2) #14 SS SCREWS PER PILE
36" — 38"
X 6' P.T. BOTTOM RAIL ATTACHED
WITH (2) #14 SS SCREWS PER PILE
(2) 5/8" SS THRU BOLTS
PER PILE
2" X 8" P.T. CROSS TIE
2" X 8' P.T. STRINGER
(24' O.C. MAX)
8.0 MARINE PILE
_j
(8' MIN. PENETRATION -10- O.C. TYP.) 2" X 6" P.T. DECKING
(NO SPACING REQUIREMENT
IN UPLANDS)
(2) 5/8- SS BOLT
(TYP) PER PILE
2" X 6" P.T. DECKING
1/2' SPACING BETWEEN
DECKBOARDS
2' X B" P.T. STRINGER
'—NOTES'—
'. 8'0 MARINE PILES - MIN. PENETRATION V INTO RIVER BOTTOM AND V INTO FIRM SOIL FOR UPLANDS
_ )R AS NECESSARYTO PROVIDE ADEQUATE BEARING STABILITY
< X 6' P.T. DECKING NOT ALL SHOWN FOR CLARITY
-DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3"
-ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304 (OR BETTER) SS
- ROPE HAND RAIL (MIN. I DIAMETER) ALONG BOTH SIDES OF ACCESS (LOCATIONS SHOWN IN SHEET 4)
SECURED WITH 016 SS RINGSHANK NAILS
- 2" X 2' P.T. PICKETS FOR RAMP NOT ALL SHOWN FOR CLARITY
1?s Environmental
Services, Inc-
1901 SW Yellowtail Avenue
Port Saint Lucie, FL 34953
ROPE HAND RAILS
I BOTH SIDES OF ACC
4• r_ JI (LOCATIONS
SHOWN IN SHEET 4)
7
Ti
(MAX)
54
MLW
2" X S-} -
CROSS-TIETIE
VARIES
SUBSTRATE
DOCK ACCESS CROSS SECTION VIEW
SCALE 1" = 2'
a
EXISTING GRADE
2' X 2' PICKETS
4' MAX. OPENING
REQUIRED ON ALL RAMP
AREAS> 30" ABOVE GRADE
OFBANK
/ 8'0 MARINE PILE
(3' MIN. PENETRATION -10'O.C. TYP.)) �y
RE IEWED FOR
CODE COMPLIANCE
RAMP DETAIL SCALE 1" = 3' STe LUC9E COUNTY
BOCC
RAMP DETAIL AND DOCK ACCESS DETAILS
Robert Harper Jr.
1908 Lynx Dive
Fort Pierce, Florida
PCN# 1425-620-0028-000-4
Paul Welch, Inc.
1984 SW Biltmore Street, #114
Port St. Lucie, FL 34984
OCT 2 8 2019
Paul Welch, PE No. 29945
Phone: 772-215-3997 Fax: 772-8794520
www.dlsenvironmentalservices.com
SCALE:
AS NOTED
OCT 2019
SHEET 2 OF 4
1s'
2X RIDGE BOARD
WRAPPED IN FELT
24'O.C.
(MAX)
8't
ROOF LINE
2° X 8° P.T. STRINGERS
2- X S.
P.T. DECKING
(NO SPACING REQUIREMENT
ON PLATFORM)
DOCKACCESS
(SEE SHEET 2)
— 2' X 8' P.T CROSS -TIES
10" 0 ROOF PILES
DOCK PLATFORM PLAN VIEW DETAIL
SCALE V = 3'
tz) Z- A Iu- Y.I.
(2)2' X 12' HEA
NOTCF
2' X 8' P.T. R
16'
2' X 8' P.T. FASCIA
10"0 ROOF PILE
SPEICAL TILES OR HIP AND RIDGE TERMINAL TILE
MORTAR TO FILL GAPS
` MORTAR OR OTHER WEATHERBLOCKI
_L ,HIP ROLE TILEf
2X HIP BOARD WRAPPED IN
ADHESIVE ROOFING CEMI
NAIL TO HIP BOA[
HIP STARTEm
UNDERLAYMENT
RIDGE TILE
TYPICAL RIDGE AND HIP BOARDS
N.T.S.
j
(2) 5/8" SS THRU BOLT
(TYP) PER PILE
MOTES***
_,L 10"0 MARINE PILES (ROOF) - MIN. PENETRATION 10' INTO RIVER BOTTOM OR AS NECESSARYTO PROVIDE ADEQUATE BEARING STABILITY
2' X 8° P.T. DECKING NOT ALL SHOWN FOR CLARITY
DECKING ATTACHED WITH #10 SS DECK SCREWS X 3'
RIDGE JOIST FASTENED WITH (4)16-D NAILS EACH JOIST —TOE -NAILED
SEE ROOF CROSS SECTION FOR MORE INFORMATION
ALL HARDWARE ON THE DECK AND BELOW - GRADE 304 (OR BETTER) SS
Environmental
Services, Inc.
1901 SW Yellowtail Avenue
Port Saint Lucie, FL 34953
Phone: 772-215-3997 Fax: 772-879-3520
www.disenvironmentalservices.com
PLATFORM PLAN VIEW AND ROOF DETAILS
SCALE:
Robert Harper Jr.
1908 Lynx Dive
Fort Pierce, Florida
PCN# 1425-620-0028-000-4
AS NOTED
10,
BEAM AND RAFTER PLAN
SCALE V = 3'
SC N ED
By
St. Lucie County
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Paul Welch, Inc.
1984 SW Biltmore Street, #114
Port St. Lucie, FL 34984 /
OCT 2 8 2019
Paul Welch, PE No. 29945
OCT 2019 1 SHEET 3 OF 4
16'
(2)2" X 10" P.T. RIDGE JOIST
(4) -16D NAILS EACH JOIST
SPANISH TILE ROOF (INSTALLED PER MANUFACTURER SPECS)
OVER 3/4' CDX PLYWOOD
W110D SS RINGSHANK NAILS @ 4" O.C.
PERIMETER AND 8' O.C. FIELD
2" X 8" P.T. ROOF JOIST (16" O.C.)
CONT. 2" X 8' P.T. FASCIA
WITH METAL DRIP EDGE
(2)2' X 12- P.T.
HEADER CONTINUOUS
PILE NOTCHED 3"-4" FOR HEADER
W/(2) 5/8- SS THRU BOLTS EACH PILE
MHW
2" X 6" P.T. DECKING
(NO SPACING REQUIREMENT
ON PLATFORM)
2' X 8' P.T. CROSS TIE
2' X 8" P.T. STRINGERS
10"0 MARINE PILES
WITH (2) 5/8" SS THRU BOLTS
PER PILE (TYP)
SIMPSON LSTA 18W/(14)-10D FROM
JOIST TO JOIST OVER RIDGE
5
-1 3 ROOF PITCH
10,
SUBSTRATE
ROOF/PLATFORM CROSS SECTION VIEW
SCALE 1" = 3'
(1) SIMPSON MTS16
W/(14)-iDDX1 %'
EACH ROOF TRUSS
8'
5't
MHW
MLW
3.34
_l
139' 20'
A7 LFOR DOCKACCESS UPLANDACCES
OVERALL DOCK CROSS SECTION VIEW
SCALE 1" = 20'
'**NOTES —
ALL DOCK PILES 8"0 MARINE PILES - MIN. PENETRATION V INTO RIVER BOTTOM AND 3' INTO FIRM SOIL FOR UPLANDS
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
ALL ROOF PILES 10'0 MARINE PILES - MIN. PENETRATION 1V INTO RIVER BOTTOM
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
L MOORING PILES AND BOAT LIFT PILES 10"0 (OR GREATER) MARINE PILES -MIN. PENETRATION V INTO RIVER BOTTOM
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
- DECKING WILL BE ATTACHED WITH 010 SS DECK SCREW X 3"
ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304 (OR BETTER) SS
- ROPE HANDRAIL TO BE INSTALLED ALONG 110' OF ACCESS
- ROPE HAND RAIL (MIN. VW DIAMETER) SECURED WITH #16 SS RINGSHANK NAILS
• 2" X 2" PICKETS FOR RAMP NOT ALL SHOWN FOR CLARITY
Environmental
Services, Inc.
1901 SW Yellowtail Avenue
Port Saint Lucie, FL 34953
Phone: 772-215-3997 Fax: 772-879-4520
www.disenvironmentalsemices.com
CROSS SECTION VIEWS
Robert Harper Jr.
1908 Lynx Dive
Fort Pierce, Florida
PCN# 1425-620-0028-000-4
AS NOTED
ROPE HAND RAIL
ALONG 110' OF ACCESS
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
Paul Welch, Inc.
1984 SW Biltmore Street, 0114 /
Port St. Lucie, FL 34984
OCT 2 8 2019
Paul Welch, PE No. 29945