HomeMy WebLinkAboutPLANSfinger pier
Boat Lift
1
P.E.
1402
Fort
PROPOSED
Pro osed <
'Spinner'
Jet Ski Lift
M a VEZE 0, 11
8'
E'V V
t�
O4-
'rd,
a
Permit Number
o r
Lot 636
00
"' SCANNEI�°e
o �e BY��ne
St. Lucie County
56-0191038-002-EE I IV ju
Southeast District
� azvIS
Langone Residence
10701 S. Ocean Dr., Lot 636
Jensen Beach, FL 34957
V" Vk -03�
FO
CO R
E COMPLIANCE
ST. LUCIE COUNTY
BOCC
Proposed Langone Proposed Finger Pier Wilco Construction, Inc. Date: 8125/19
Plan View & Boat Lift on Lots 636 (772)460-6928;FAX(772)460-6929
i
Pilings:
N
TYPICAL DOCK AND ACCESSWAY CROSS SECTION
Dock min. 8"0,
(N.T.S.)
Boat lift min.10"0
c
2.5 CCA
�z
PT wood,
o F E N
r
max.12' OC
O
The work specified herein
has been designed and all
work shall be in
�1,I
O
' +
accordance
4 VA
W
with the 2017 Florida
4
J
Building Code (6th Edn.).Aq
Permit Number
_
All codes reference herein
are the latest adopted
q
Width; 4 r
�I MST
per
edition.
56-0191038-002-EE
b
�1�
p Southeast District AV
bo ld
pG
VLS
3 a
2" p�A Q#1 Tropical De ' �tiy
ON
"p
board need a 112"
fastened w i el screws
STRINGERS:
2l d
2"x8" 0.4 ACQ
spaced at max. 24" with
min. 1/2" SS
lag bolts on each piling (lap
spliced)
/
/
•
2 16d Toe
Nails Typical
Tie Down Blacks:
2"x6"xl2" 0.4 ACQ strap
Joist:
blocks @mid stringers
2"x8" 0.4 ACQ on
(fastened whin. 3 ea.
each side of piling.
min. 3" SS screws/nails)
Bolted wl 5/8"
SS cut rods.
Min. 6'
solid penetl
M.L.
RIVER BOTTOM
L�J
Cross View
Langone Residence-
Wilco Construction,
a
Dock Structural
Inc.
€
p F E N Vl�O,Y
a a
v Permit Number y
� r
56-0191038-002-EE
z
p Southeast District
r
O
'Y o
�.tvzs'
LOT 636
0
'Y
Jet Ski Lift
Existing Marginal
Dock 8'x20'
4 piling Boat Lift
finger Pier
Pilings to be @
higher elev. per
Proposed 4'x17' client
/ Finger Pier
MHW (-0.43' per Labins PT954)
e a=
MLW (-1.40' per Labins PT954)
Dist. from MHW (ft): 10 ' ?
Depth as measured at 4,21± 8' 50'
Mean Low (ft): 4 5'+ N 6.8'±
25'
ources
o g
iel Pa
#724
0. 2 y O _
artman Road �O'
, FL 30 7
Cross b
Langone Proposed Finger Pier 8� wilco cons tiDate: 8/25/19
View Boat Lift on Lots 636 (772)460-6928;FAX(77 460-6929
FILE COPY
Project Name:
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553
Certification for Design Load Compliance
LANGONE
Proi.ectAddress: 10701 S OCEAN DRIVE LOT 636
Permit It: occupancy Type: Construction Type:
This certification must be completed, signed, and sealed by the design professional of record.
o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
0 Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for Interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as'(check one): _Enclosed _Partially Enclosed X Open
3. Risk Category:_I X 11 _III_IV Exposure Category:_BC X D
4. Design Wind Velocity 165 mphASD X LRFD End Zone Width: 1 ft
S. Mean Roof Height 5'+/- DECK HEIGHT ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4:+60.6/-64.1 Zone 5:+70.11-74.5 Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
B. Were Shear Walls Considered For Structure? X Yes _NotApplicabie Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
DANIEL PAUL RETHERFORD 72451
Print Name Cert # & Co. Cert Auth.
1402 HARTMAN ROAD, FORT PIERCE, FL 34947
Company Name & Address
a
O
U
W
J_
LL
M
N
0
z
ENGINEERING REVIEW:
BOAT LIFT TOP CARRIER BEAMS AND
MOUNTING BRACKETS COMPLY WITH WIND
LOAD REQUIREMENTS OF THE 67H EDITION
(2017) FLORIDA BUILDING CODE, PER ASCE
7, AND PER DESIGN LOAD REQUIREMENTS
OF THE 2015 EDITION ALUMINUM
ASSOCIATIONSS ALUMINUM DESIGN Mf
BEAMS AND MOUNTING BRAC,
INSTALLED PER HI —TIDE INSTRUCTION
EXCEED ULTIMATE DESIGN WIND SPEI
180 MPH (EXPOSURE CATEGORY C
BOATS ARE TO BE REMOVED FROM E
LIFTS PRIOR TO A MAJOR WIND EVE
PILINGS.•
PILING PENETRATION TO BE 10'
INTO THE SAND BOTTOM OR 5'
INTO ROCK STRATA,
SUB —SURFACE CONDITIONS CAN
VARY GREATLY, THE CONTRACTOR
SHALL VERIFY ALL PILE
CAPACITIES TO COMPLY WITH
FBC 2017. ALL PILINGS TO BE
8" MINIMUM DIAMETER
2.5 C.C.A PRESSURE TREATED
WOOD, PRE -STRESSED CONCRETE
OR COMPARABLE EQUIVALENT.
ELECTRICAL CAAL RFVIFW..
1/2 HP ELECTRIC MOTOR
8.8 AMPS 0 115V EACH
4.4 AMPS ® 230V EACH
QUAN77TY' 2
70TAL WATTS: 2024
X2-i
1 HF
12.8
6.4 AMPS M Z3UV LAUH
QUANTITY.* 2
TOTAL WATTS: 2944
9,000 LB. GEAR DRIVE &
GEAR DRIVE X2 BOAT LIFT (2017 FBC)
R. HYDE SCALE.• NT5 DATE'' 1/2/18 REV! 1
NOTE TO EXAMINER:
THIS CER77FIED ENGINEERED
DRAWING HAS BEEN PREPARED
SPECIFICALLY FOR USE ONLY BY.•
oe0°oop0p 186.001o°°00°Oo
c° N M
O 0 E At
O v F F °
N0.43866 9 '
w1
OVr� 2 8 0
o
eRs�EORIOr
000 N Ao 00u°"e o�OOo
ROGER SABER
P.E. NO. 43855
CR PROFESSIONAL ENGINEERING
C.A. NO. 26967
1014 NE PINELAKE DR.
STUART, FT. 34994
ING MOUNTING TABS
'MUM (2) 3/8" DIA. SS LAG
TS FOR WOOD PILING OR
CONCRETE ANCHORS FOR
'CRETE PILINGS PER PILING
OUIR£D.MINIMUM (2) 3/8"
SS CARRIAGE BOLT FOR
'ACHING MOUNTING TAB TO
LIFT REQUIRED PER PILING.
MOUNTING TAB CONSTRUCTED
FROM 1/4" X 2" ALUMINUM
6061-T6 FLAT BAR.
BOA TLIFTS AND MARINE PRODUCTS
4050 SEL N7Z ROAD
FORT PIERCE, FL 34981
1-800-544-0735 www.hi-fide.com
ENGINEERING RENEW.•
BOAT LIFT MOUNTING BRACKET AND
SPECIFIED MOUNTING HARDWARE COMPLY
WITH WIND LOAD REQUIREMENTS OF THE
6TH EDITION (2017) FLORIDA BUILDING
CODE, PER ASC£ 7-10, AND PER DESIGN
LOAD REQUIREMENTS OF THE 2015
EDITION ALUMINUM ASSOCIATION'S
ALUMINUM DESIGN MANUAL.
MOUNTING BRACKET INSTALLED AS PER
HI -TIDE INSTRUCTIONS, WILL EXCEED
ULTIMATE DESIGN WINDS SPEED OF 180
MPH (EXPOSURE CATEGORY C OR D)
BOATS ARE TO BE REMOVED FROM BOAT
LIFTS PRIOR TO A MAJOR WIND EVENT
PIL/NGS'
PILING PENETRATION TO BE 10'
INTO THE SAND BOTTOM OR 5'
INTO ROCK STRATA,
SUB -SURFACE CONDITIONS CAN
VARY GREATLY, THE CONTRACTOR
SHALL VERIFY ALL PILE
CAPACITIES TO COMPLY WITH
FBC 2017. ALL PILINGS TO BE
8" MINIMUM DIAMETER
2.5 C.C.A PRESSURE TREATED
WOOD, PRE -STRESSED CONCRETE
OR COMPARABLE EQUIVALENT.
ELECTRICAL REVIEW.•
1 HP ELECTRIC MOTOR
12.8 AMPS ® 115V EACH
6.4 AMPS ® 230V EACH
QUANTITY.• 1
TOTAL WATTS 1472
NOTE TO EXAMINER:
THIS CER77RED ENGINEERED
DRAW/NG HAS BEEN PREPARED
SPEORCALLY FOR USE ONLY BY.•
CENB 'o °Oo
4• N0.4310
P R�JEB OtT
A Q'
'p STATE OF W e
°o Fe LORI OI'p2o°°
O N A o
ROGER BABER
P.E. NO. 43855
MCR PROFESSIONAL ENGINEERING
CA. NO. 26967
1014 NW PINELAKE DR.
STUART, FL 34994
PILING MOUNTING
MINIMUM (4) 3/4- DIA. BOLTS
FOR THROUGH BOLTING
BRACKET TO PILING.
PILING MUST BE TIED BACK TO
SEAWALL OR DOCK STRUCTURE.
ALTERNATE SEAWALL
M O U N T I N G
MINIMUM (6) 3/4- DIA. SS
ANCHORS REQUIRED IN
CONCRETE BASE FOR MOUNTING.
FILE C®Py
1,500 LB. ALUMINUM SPINNER M� O BOATLIFTS AND MARINE PRODUCTS
(2017 FBC) l n t��4050 S£L NTZ ROAD
®VE, FORT PIERCE, FL 34981
.hi—t
R. H1DE SCALE. N75 DATE.• 1/2/18 REV.1 1-800-544-0735 www.hl—Hde.com