HomeMy WebLinkAboutBOAT LIFT PLANENGINEERING REVIEW.•
BOAT LIFT DRIVE UNITS AND SPECIFIED
MOUNTING HARDWARE COMPLY WITH
WIND LOAD REQUIREMENTS OF THE
6TH EDITION (2017) FLORIDA BUILT" —
CODE, PER ASCE 7-10, AND PER DE.
LOAD REQUIREMENTS OF THE 2
EDITION ALUMINUM ASSOCIATIC
ALUMINUM DESIGN MANU
DRIVE UNITS, INSTALLED AS PER HI —
INSTRUCTIONS, WILL EXCEED ULTIk
DESIGN WIND SPEED OF 180 A
(EXPOSURE CATEGORY C OR
BOATS ARE TO BE REMOVED FROM E
LIFTS PRIOR TO A MAJOR WIND EV
PILINGS.
PILING PENETRATION TO BE 10'
INTO THE SAND BOTTOM OR 5'
INTO ROCK STRATA, SUB —SURFACE
CONDITIONS CAN VARY GREATLY,
THE CONTRACTOR SHALL VERIFY
ALL PILE CAPACITIES TO COMPLY
WITH FBC 2017. ALL PILINGS TO BE
10" MINIMUM DIAMETER
2.5 C.C.A PRESSURE TREATED
WOOD, PRE -STRESSED CONCRETE
OR COMPARABLE EQUIVALENT.
m
n
'O
-• 1 ELOR
.AMPS 0 115V EACH
6.4'AMPS ® 230V EACH
;QUANTITY.• 4
,yJOTAL WATTS: 5888
NOTE TO EXAMINER:
THIS CERTIFIED ENGINEERED
DRAWING HAS BEEN PREPARED
SPECIFICALLY FOR USE ONLY BY.•
- M e
iV O E N B\
v F
NO.43M _
l
R EDSEPlpy It
A
'P STATE OP W ."
O 4/ e
°0c a F8 A•L O R 1
0
°eOOe 8 °Do., 1 uoo°°
ROGER BASER
P.E. NO. 43855
MCR PROFESSIONAL ENGINEERING
C.A. NO. 26967
1014 NW PINELAK£ DR. SMART, FL 34994
PILING MOUNTING
MINIMUM (2) 3/4- DIA. SS THRU
BOLTS FOR WOOD AND CONCRETE
PILINGS REQUIRED PER PILING TO
SECURE DRIVE UNITS PER FBC 2017.
" tow
eee.oaee2 12,000 LB. T2 TOPLESS X2 0#1
BOA TLIFTS AND MARINE PRODUCTS
e i°rma.WAsven ° ) �4050 SELVITZ ROAD
' BOAT LIFT 2017 FBC
• FORT PIERCE, FL 34981
r cuvmrawev . R. HYDE SCALE: N75 DATE. 1/2/18 REV 1 1-800-544-0735 www.hi-tide.com