HomeMy WebLinkAboutSITE PLANS. W
r
Y
L41 O�IICI4h Yb. ;
,•tiutiwlNe�
-
- �j
��
u
OF EW
Project Sig
I*J
_
Ir
s• -y
�f
i Permit Number
A.
'i
56-0380779-001-002-EE
r
_
b
j
Southeast District'
I
y°
0
fMlV 4WM 1 r '
S 14*
�cvss'
-
y
AU R
(
<f jr'
-3
laniewa
�.112 O
SCANNED }e 1-Re 724 .1 7o Led
MIN. SETBACK RE
BY v3 Zo �� 10 2
FRONT
_
St. Lucie County O� �
a�DAJot,
SIDES
_
mSIR
349
Fo Ip
ENG
130 S. Indian'Iirver Drive
David HIII
AL et 1 of 8
�—
Suite
118 Queen Christina Court
September 13, 2019
Pierce,
Fort Pierce, FL 34950
L41 nvironmental ConsWtsnts (772) 577-4141
Hutchinson Island, FL 34949
kk
is t 29 4+
•ter ' �";� yr' t ) .,
elf; .+iir " Y - i• `'r' C "` � �' I- - �
25
OVCrel 1!
1�
�+` • �4'` "•.` Existing 64LF 1 •�' `�, seawall to be 1 ; d _ LX r
replaced r—Existing •• y vi P` `j V . •V'
y a,ai boatlifttobe •� ; ,
.i • ' s .— •'O • , replaced/'•-
!
Ucr f.s't' p1r► relocated I, L
LilExisting 3845',4
C+''. dock to be. . - - %'\;��'� I• a}�
� .: replaced
11``l:+ K� 1, •�ttJ fyy'..S_) S L w,►�i�``V.i..r ,y1`S ✓� {
4. * +r�.. _ s) ._I_ll_'�APPl, , t. —AA, G'IYCP�ir�.w♦..v'"••\�s�
lMj0lyA
q •.
Existing Conditions
QP\•
118 Queen
Christina Court N
Existing Nei
ghborApock
Existing 1
1 Neighbor 1 .t ° F E N V
40-1
to +
in d
to
S LL v p4
Fp o 4 Permit Number
tto v
I r
• c o` 1' ' - i� + 56-0380779-001-002-EE
_y 1 Existing 1 b
O v 1 eoatift to9 be 1 i A7
\ W N m 1 Remo•d 1 P utheast District
y°
_ ! r es►clential Canal
W
` �0P\ one x � °�d• O�y
I
6 ani au1 R IF
\i g. 72451No. ,72451
v - TE OF
Not to scale. for
A?q-T R D EA 130 S. Indian River Drive N
David Hill NALS ofs
Suite 202 118 Queen Christina Court September 13, 2019
Environmental Consullanta, Fort Pierce, FL 34950 P
(772) 577-4141 Hutchinson Island, FL 34949
w
J
U.
118 Queen
Christina Court
'\ Proposed Work
Q\
\
A rt Pierce, R D EA Force, F RiverS. Indian 349 Orive
Env'vonmental Consull� (772) 577-4141
\
�l
a�lZ(Y^
1
r-�
PropoFed I
Boallft I
1 1
I
1
1
I Existing I
1 Neighbor I
Bootlti t I
L_ I
Mar.
seagrasses
observed
9/13/19
Residential Canal
Not to scale, for pe
David Hill
118 Queen Christina Court
Hutchinson Island, FL 34949
4
?AUL
FLORIDAF
-ShnT4of 8
September 13, 2019
Rev. 10130119
a
0
LU
J_
LL
Seawall Details
12" x 20" Concrete Cap w (4) #S,
#3 Ties, 24" O.C., 3' from
60 KSI Rebar continuous w 18"
outside edge of concrete
Overlap
)r
15'+/-
Below Cap
....... ...
CL 9900 Vinyl
"erld3" W
Sheet Piling
not
Reinforced Concrete
. . . . . .. ......
(Pre -Cast)
R IV
Concrete Cap & Deadman Poured
onsite w SOOO PSI Concrete
Concrete Cap
CL 9900 Series Shoreguard Sheet Piling
Yermit Number +
56-03P0779-001-002-EE
Wpcohsaemdfdrgaeexel
i
20"
1=1
4— 24•-
e
Desi WiQ ad Information
.6 L;
U
Cad . FB 17 6- ADD/FRC 2017/ASCE 7-10
o
U
U
. . . .
W' cis 170 MPH, 3 Second Gust
12"
Lr;
PH
p
11 nce Factor: 1.0
,
nal Pressure Coeff.: 0.00
eight: <10 Ft. Mean
#3 Stirrup
All Construction Must Meet Applicable
Portions of the 2010 FBC and/or the 2008
1 Re rd,
NEC, Whichever Is More Stringent
p. 7 51NO,
Not to scale, for permitting purposes only
;,24S
0
14
F3
s co, F goA
130 S.,Indian River Drive
Suite 202Sheet
David Hill
6 of 8
118 Queen Christina Court
Fort Pierce, FL 34950
r Environmental Consulter
(772) 577-4141
Hutchinson
Island, FL 34949
L E
C
LL
C:)
U
Dock Access Section Thru
SGL Bolts, Nut, Washers
5/8" S.S. (304) w Nut Fully
Threaded @ Bents
6 feet +/-
Will reuse existing
x"x Vuss composite decking, w/
-- r„S`,I„¢e„ minimalplank #103-SS(30. -
�R\- Fasten wN103"SS (304)
Screws, 2 per Stringer
a 2" x B" P.T. SYP, 0.40 ACQtreated
v stringers.
2" x 10" P.T. SYP, 0.40 ACQtreated
aax„x„ DBL bents
MLWL
(CCATreat�e
..................•. . . ••4lryl•rM�l}l•Barren River Bottom }7}}.;.}}.r•M1••L•1•M1•M1•1i•••r•r•r•r.r•r•r•h4L•L.L•M1.4.1Min. 9"with 6'
Not to sca
W;M— 130 S. Indian River A R D E► Suite Fort Pierce, FLrive
349 O
Environmental Condtiltori4s (772) 577-4141
C
Dock Access Plan View
spacing max.
P Southeast District
6 feet+/-
A
sR 1;
An, rs tied
12.40treat
;-4 s@ea
b
VA. D - n Windloa I
O,§ e: FBC 2017
ind Speed: 170
�O Importance Facto ]{
x�p _ Internal Pressure Co
for ermittin pni Heignt: <10 Ft. Mean
David Hill
118 Queen Christina Court
Hutchinson Island, FL 34949
x N
0 N
n
Sheet 7 of 8
September 13, 2019
91i
£NV%TER 'G,ffiY ,
BOAT LIE'T DRIVE UNITS AND SPLWMU
MOUNTING MABDWARC'COMPLY WITH
WIND•LOAD REQUIREMENTS Or THE
0rN EDITION (2017) 7LORIVA BUILDING
copL. PER ASOE 7-Ia'AND PER DEAD!
LOAD REDUIREMENTS Or WE 20I5.
EDITION ALUMINUM ASSOCIATION'S
ALUMINUM DESIGN MANUAL.
. OMbr UV ES, INSTALLED AS PER I0-TIDE
INSTRUCTIONS. WILL EXCEED ULTIMATE
DESIGN WIND SPEED Or LBO MPH
(EXPOSURE CATEGORY C OR 0)
BOATS ARE TO BE REMOVED7ROW BOAT
UrTS PRIOR TO A MMGR KNO EVENT.
ym-
MIND PENETRATION TO BE 10'
INro THE SAND DOTTOM OR'5'-
WO ROCK STRATA, SUO-SWYACC
CCNwnONS-CAN VARY GREATLY,
THE cavwcra4 SHALL VERIrr
ALL PILE CAPACITIES -TO COMPLY
WWI I= M17. All I"= TO d
100 MINIMUM DIAMETER
P.S C.C.A PRESSURE TREATED
WOW. PRE-SIRESSCO CONCRETE
OR COMPARABLE EOVIYALENr.
r u�. .
-- AMPS • IISV U01
0.1 AMPS 0 230V UPI
WAUBT! A
TOTAL WATTS- 5M
M���i/�I.JILAI`S�Y O
72,000 L8. T2 TOP[
BOAT.VFT (2017
P. N1OC SCALE MS DATE.
Drive
Suite A R D EA Fort Pierz e, FL 34950
Environmental Consuhrrnts. (7721577-4141
xDTc I!I TY.IT/flh
ARS WM HAS
BEEN FCRED
PARM
Sfr( C NAS QCA1SC CWLY
sPE�uLLr rar,Lrse nersr,
O IN At
s
IED 5EP 1
OTATEO►
RD'W a4hM
PC Na "W
MWGi nriN➢QO7��
1014 IM NWAAV Of. STUAXD 2 71591
PUINC MO.UNTM
i vt POP..lh%Vt
rgermit Number
56-0380779-001-002-EE
:r
David Hill
118 Queen Christina Court
Hutchinson Island, FL 34949
NO
Pw
L
Sheet 8 of 8
September 13, 2019
N
a
O
0
LU