HomeMy WebLinkAboutTRUSS PAPPERWORKLumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
RE: J38289 - J38289-Williams Const.-Shed MITek USA, Inc.
Site Information: SCANNED 6904 Parke East Blvd.
Customer Info: Williams Construction Project Name: Shed Model:BY Tampa, FL 336104115
Lot/Block: Subdivision: St. Lucie County
Address: 2306 N 49th St.
City: Ft. Pierce State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License M
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017[rPI2014 Design Program: MiTek 20/20 8.2
Wind Code: ASCE 7-10 [All HeighIl Wind Speed: 160 mph
Roof Load: 40.0 psf Floor Load: N/A psf
This package includes 10 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1
T17961493
A01
8/26/19
2
T17961494
A02
8/26/19
3
T17961495
A03
8/26/19
4
T17961496
A04
8/26/19
5
T17961497
A05G
8/26/19
6.
T17961498
ZCJ1
8/26/19
7
T17961499
ZCJ3
8/26/19
8
T17961500
ZCJ5
8/26/19
9
T17961501
ZEJ7
8/26/19
10
T17961502
ZHJ7
8/26/19
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
S®CC
Yee
The truss drawing(s) referenced above have been prepared by MiTek USA, Inc.
under my direct supervision based on the parameters
provided by East Coast Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2021.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MITek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and property
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
RECEIVED -
NOV 2 2 71119
Permitting Department
St. Lucie County
�.` � .• �GENS' •'9Q.''.
'9 , STATE OF Z
JSS�CNA�
Thomas A Albani PE No.39380
MITek USA, Inc. n Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August 26,2019
Albani, Thomas 1 of 1
Jab
Truss
Truss Type
Oty
Ply J38289-Williams Const-Shed
T77961493
J30289
A01
Hip
i
1
Job Reference (optional)
�1
nr Tuss, R. rierce, rc a vxiv 8,240 s Jul 14 2019 M7ek Industries, Inc. Mon Aug 2613:04:26 2019 Page 1
ID:PHC 4FwUxEoe2mzHcuyOvpyjzkq-31RM5AOFe bnBockoeSwliMhl VXSlefAnt4LCLyiZPJ
15M1i2
10.114 1 22-2A 3POL 32fb
7-1-12 08 2 ]-t-12 ]58 21F0
Oh12
scale =1:55.a
44 =
30 = ix4 ll 3x8 = 3x4 = 1x4 II 3x4 =
15at2
]98 I 10.1t4 1540 22-24 I 3080
]+48 ]-t-t2 2
LOADING (psf)
SPACING-
2-04)
CSt.
TCLL
20.0
Plate Grip DOL
1.25
TC
0.53
TCDL
10.0
Lumber DOL
1.25
BC
0.71
BCLL
0.0
Rep Stress Ina
YES
WB
0.31
BCDL
10.0
Code FBC2017/TPI2014
Matrix -AS
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. Utilsize) 2=1323/0A-0, 6=1323/0-8-0
Max Holz 2=241(LC 7)
Max Uplift 2=-740(LC 8), 6=740(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2445/1151, 34=1666/866, 4-5=1666/866, 5.6=-2445/1151
BOTCHORD 2-11=891/2192,10-11=-891/2192, 8-10=-891/2192, 6-8=89112192
WEBS 3-11-01311, 3-10=863/473, 5-10=864/473, 5-8=0/311, 4-10=348/807
DEFL. in (roc) Udell L/d PLATES GRIP
VerULL) 0.16 10 >999 240 MT20 2441190
VerUCT) -0.28 10-11 >999 ISO
Horz(CT) 0.10 6 n/a Na
Weight: 1401b FT=0%
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOTCHORD Rigid ceiling directly applied.
WEBS IRow at midpt 3-10.5-10
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=30ft; L=3Dft; eave=oft; Cat.
II; Exp C; Encl.. GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Plates Checked for a plus or minus 0 degree relation about Bs Center.
4) This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 200 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10016 uplift at joint(s) except (jt=lb)
2=740, 6=740.
7) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 112" gypsum
sheetrock be applied directly to the bottom chord.
.S1App����,,,
NO 39380
SSiONA�
im
Thamas A. Albanl PE No.39380
MTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
4YAPVINL-Wary eeag., pa.a-ar•I rlREV01e1CSON-1."11V0 rNCCJOEU MIrEK REFERENCE PAGE 6114V13-v. 10032015 BEFORE US_
Design wild for use onlyweh MRek®cmnedars. This design is based only upon paremeiam shown, and is for an Individual bugling component net
a buas system. Before use, Me bwiding designermust vedyme, apptirabirayordew, parameie a and prope t iriou,orate finis design rate Me owreA �
buiidragdesign. Bracing Measeted is to prevent bickfg of Individual Was web anNm chard members any.PdditionallemporaryaridpnneemembraWg MiTek' is afe4s required for stability and to prevent co0apse with recaltle personal In)unyand property damage. For general guldanee regarding die
fabdcogen,storage, delivery,erection and trading ofbuwas and Miss systems. see ANSI?Pll Dualcy Criteria, DSBA9 and BCSI Building Component 6904 Palle East Blvd.
Safervialb mal0n available from Trues Pieta Insixule.21H N. Lee Sireel, Suds 312 Alexandria, VA 2YJ14. Tampa R WIG
1$
August 26,2019
Job
runs2
Truss Type
pry
ply J38289-Williams ConsL-Shed
T77961494
J3B289
Hip
2
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34945
�1
Axis =
4x4 =
8.240 s Jul 14 2019 MTek Industries, Inc. Mon Aug 2613:04:28 2019
3x4 =
1x4 II 3x4 = 3x4 = 1x4 II 3.4 =
3.8 =
6&14 13-0-0 17-0-0 23.2-2 36-0-0
6-9-14 6-2-2 d-D-0 t 6-2-2 t 6.41d 1
Scale = 155.8
Plate Offsets (X,Y)—
f4:0-5.4,0.2-01
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in (lac)
Vdeg
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Verl(LL)
0.16 12
>999
240
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.62
Vert(CT)
-0.28 12-13
>999
180
BCLL 0.0 '
Rep Stress ]nor YES
WB 0.67
Horz(CT)
BAD 7
n/a
nla
BCDL 10.0
Code FBC2017rrP12014
Matrix -AS
Weight: 151 lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=132310-8.0, 7=1323/0-8-0
Max Horz 2=214(LC 6)
Max Uplift 2=740(LC 8). 7=740(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250(I1b) or less except when shown.
TOP CHORD 2-3=2503/1173, 3-4=1825/934, 4-5=1622/920, 5-6=1826/934, 6-7=-2502/1173
BOT CHORD 2-13=923/2252, 12-13=-923/2252, 11-12=-559/1621, 9-11=-923/2252, 7-9=923/2252
WEBS 3-13=01278, 3-12=744/404, 4-12=140/415, 5-11=140/415, 6.11=744/404, 6-9=0/277
NOTES.
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.OpsY h=15ft; 6=301C L=30g; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water panning.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconwmenl with any other live loads. •••
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ut=11b)
2=740, 7=740.
8) This truss design requires that a minimum of 7/16- structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
`%%% NSIA7F q4. ,..
a.
No 39380
F
4SS/ONA� ��Ca,.
Thomas A, Albert PE No.39380
MITek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August26,2019
,&.N,.\G-V—', aes:gn paranterera antl BEAO I:DrrS ON •V., AND 1: CLU,3ED M TEK REFeRc \CC PAIL W1.74r3 rev I0,03,70156EFO RE- USE
Design valid faruse onywah Mirewaconnecare This design Is baser) any upon parameters shown, and is Man Indlvidaal S AM, oomponenL not
a Was system. Before use, Me building designer must wayme appllcabilAyof design parameters and properly Ncor,mote this design into the oVeral
bugsingdesign. Bracing Indicated is to prevent buckling of Ndlddual truss web andlcr cord members will, MdGonaltemporaryandp==eMWchg
MiTek'
is always required for stability and to prevem cagapse with possible personal injury and property damage. Forgenerdiguldanceregardingthe
fabdcagon, storage, der n, creation and binding aftmsses and bass systems, see ANSg7P11 Quality creeds, DSB49 and BCSI Building Component
6904 Parke East BIM.
Saywfylnfwrmanda. analabla Wm Truss Plata lnstAule, 218 N. Lee SWH, Suneal2, Nexantlda, VA2a31A.
Tampa, FL assia
Job
Truss
Truss Type
Qry
Ply J38289-Williams Const-Shetl
T17%1495
J38289
03
Hip
2
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946
8.240 s Jul 14 2019 MiTek Industries, Inc.
ID:PHC_4FwUxEoeZmzHcuyOvpyjzkq-Ut6YBS8v L7
i 19-M 24-2-2
fl B 5-2-2
4x8 =
4x6 =
4 20 21 5
26 13:04:29 2019
3x4 = 1.4 II 3x4 = 3x4 = 1x4 II 3x4 =
3x8 =
59-14 11-0-0 19-0-0 2d-2-2 30-0-0
59-14 5-2-2 1 8-0D 52-2 5-9-14
Style = 1:55.8
I$
Plate Offsets (X Y)—
14:0-5-4D-2-0)
LOADING (pst)
SPACING-
2-0-0
CsL
DEFL.
in (Joe)
been
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.87
Ven(LL)
OA7 10-12
>999
240
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC
0.65
Vert(CT)
-0.34 10-12
>999
180
SCLL 0.0 '
Rep Stress ]nor
YES
WB
0.35
Horz(CT)
0.10 7
n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Matnx-AS
Weight: 1471le
FT=0%
LUMBER.
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1323/0-8-0, 7=1323/0-8-0
Max Horz 2=185(LC 7)
Max Uplift 2=-740(LC 8), 7=740(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
WEBS 1Row at midpt 4-10
FORCES. ile)-Max.Comp./Max. Ten. -All forces 250(lb) or less except when shown.
TOP CHORD 2-3=-2535/1184, 3-4=-2036/1019, 4-5=1841/997, 5-6=2037/1019, 6-7=-2534/1185
BOT CHORD 2-13=-941/2287, 12-13=941/2287, 10-12=-680/1840, 9-10=941/2286, 7-9=941/2286
WEBS 3-12=-547/290,4-12=-83/443, 510=83/443, 6-10=-548/290
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wine: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=30ft; L=30ft; eave=411; Cat.
II; Exp C; Encl., GCpl-0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 pal bottom chord live load nonconcument with any other live loads.
6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ile uplift at joint(s) except Qt=lb)
2=740,7=740,
8) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
`,`,OOPS1A 1111<e,,''
E Ns
i
No 39380
Iz-
3- F
�itC •.0RI0• •\��
ss�0NAI-En�
nn%0'
�la0"
Thomas A Albans PE No.39380
MTek USA, Inc. FL Carl 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August 26,2019
�'NARMNG -VeAy das:pn pa,a... erers and PE40 NOTES IN NOS AND INCLLJ.-D R I Sh' REFEFCNCE PAGS MLL)4b rev. 10032015 Bc'"ORE USE
Design valid for use ord wait MTeMsonnectors. This design is based only upon parameters shmen, and is for an individual building component nm
atmsssystem.Before use, 0e building designer ..at verify the applicability ofdevgn parameters and proper Nwmorate Nis design motbe overall
buddingdesign.BMCMgindiutedistopmvnLWWingofindiNdual Wssweband/or NoNmembemeny. Addeional temporary and permanerd bracing
MiTek'
is always required for stability and to prevent collapse with possible personal injuryand propemy damage. For general guidance regarding the
fabncetlon, uomge:detvery,erection and trading ofbusees and tries symems, see ANSgrPN Duality e@eta, DSBA9 and BCS/ Building Component
6904 parke East Blvd.
Saferyln/ormadon avatlable from Tmss Plate InsibNe, 21B N. Lee Street, aude312, Alexandra. VA 22314.
Tampa. FL 36610
Job
Truss
Truss Type
Qty
Ply J38289-WIIiams Const:Shed
T1796149fi
J38269
04
Hip
2
1
Job Reference (optional)
East Coast Truss, R. Pierce, FL 34946 8.240 s Jul 142016 MITek Industries, Inc. Mon Aug 26 13:04:30 2019 Pagel
ID:PHC_4FwUxEoe2mzHcuyQvpyjzkq-y4glxXTmhD5CdPwV1UXsBYXPE71X liV22L6yjzPF
49-14 9-0.0 15 4 21-0-0 2i2-2 300.0 32-0.0
I-0-O I 4-9-14 T2-2 + 6-0-0 6-0-0 4-2-2 48.14
Scale =1:55a
4x8 =
e— r
20
4x8 =
4x4 =
3x4 = 3x8 = 3x4 = 3x4 = 4x4 =
Plate Offsets (X Y)—
[4:0-5-4 0-2-0[ [6:0-5-0 0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/de0
- Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL)
0.21 12
>999
240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.81
Vert(CT)
-0.371G-19
>981
180
BCLL 0.0
Rep Stress Ina YES
WE 0.23
Horz(CT)
0.10 8
n/a
rda
BCDL 10.0
Code FBC2017/7P12014
Matnx-AS
Weight: 147 lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.2
BOTCHORD 2x4 SP No.2
WEBS 2x4 SP ND.3
REACTIONS. (Iblsize) 2=132310-8-0, 8=132310-8-0
Max Ho¢ 2=157(1_C 6)
Max Uplift 2=-740(LC 8), 8=740(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOTCHORD Rigid ceiling directly applied.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-2538/1230, 3-0=-2219/1076, 4-5=2396/1252, 5-6=2396/1252, 6-7=-2219/1076,
7-8=-2538/1230
BOTCHORD 2-13=-990/2315,12-13=-769/2013,10-12=-769/2013,8-10=-990/2315
WEBS 3-13=-075/243, 4.13=-45/399, 4-12=250/555, 5-12=399/291, 6-12=-250/555,
6-10=-05/399, 7-10=-376/243
NOTES.
1) Unbalanced mof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf", BCDL=3.Opsf; h=15ft; B=30ft; L=3Df: eave=4ft; Cat:
II; Exp C; Encl.. GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=740,8=740.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
J��QpS^A
g��•,��.•�'�GEN F ••'t'i
No 39380
WErz
-R� •...%%`�
111,11011111110
Thomas A Alban) PE No.39380
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August26,2019
® YYA4NItl9 4orily Qes,gn pararoe;ers antl READ NeTES 8N THu-NND INCLODED M1r/T-a n'chE4ENCE PAGE4114LV l rp¢ 19W 16153EK•Re' USE.assass
Design veld for use only with MTek® connectors. This design is based only upon parameters shown. and is for an indivdual batting component, not
MI
stress system Before use, the building designer must verify Me applicability of design parameters and properly incorporate this design Into Me overall
buidingdosgn. Bracing Indicated is to prevent buckling of individual miss web aralor NON members only. Addaionaltemporaryandpermanembraclog
MiTeW
is ateays required for slabifty and to prevent collapse won possible personal injury and pmpeny damage. Forgeneralguidareeregardingthe
fabrication. stom9e.delNery,ereUionand loading oftnssea6,Wbuss systems, see ANSVIPil Duality omens, DSB49 and SCSI Building Component
6904 Parke East BIW.
SaletylnPorestion available Man Tmss Plate Insiders, 218 N. Lee Street. Sue, 312. Alexandria, VA M14.
Tampa, FL 36610
Job
rus8
Truss Type
Dty
Ply J38289-Williams Catit: Shetl
T17961497
J38289
OSG
Hip Girder
2
1
Job Reference (optional)
East Coast Thus., FL Pierce, FL 34945
8,240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 26 13:04:33 2019 Page 1
Scale=1:55.8
6x8 =
3x4= 1x4 II 6x8 =
4 22 23 6 24 25 26 6 27 28 7
4
3
2je
:Zj>84x
i
9
1
15 29 30 14 31 32 13 33 12 34
4x8 = 3x4 = 4x4 = 48 M18SHS =
3x10 =
3x4 =
dx8 =
74}p 121-9 1]-7-7 23-0-0 3041-0
9 1 5-2-t3 5-0-9 ]-0O t
Plate Offsets (X,Y)—
12:0-D-0,0.0-01.14:0-6-4,0-2-121.17:0-G4,0-2-121.19:0-0-0,0-031
LOADING (psf)
SPACING. 2-0-0
CsL
DEFL.
in (loc)
9de0
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.74
Vert(LL)
0.44 12-14
>820
240
MT20
2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.58
Vert(CT)
-0.6812-14
1528
180
M18SHS
244/190
BCLL 0.0 '
Rep Stress Inns NO
WB 0.75
Hom(CT)
0.15 9
n1a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 1491E
FT=0%
LUMBER -
TOP CHORD
2x4 SP No.2'Excepl'
4-7: 2x4 SP 270OF 2.2E
BOT CHORD
2x4 SP 270OF 2.2E
WEBS
2x4 SP No.3
REACTIONS. (lb/size) 2=2450/0-8-0, 9=2450/D-8-0
Max Hors 2=129(LC 7)
Max Uplift 2=-1285(LC 8), 9=1285(LC 8)
BRACING.
TOP CHORD Structural wood sheathing directly applied or 2-2-8 Be puriins.
BOT CHORD Rigid ceiling directly applied or 5-0-10 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 23=-5428/2598, 3-0=-5262/2531, 4-5=6561/3227, 5-6=6559/3224, 6-7=6559/3224,
7-8=-5263/2532, 8-9=-5428/2598
BOTCHORD 2-15=-2255/4958, 14-15=2155/4867, 12-14=-2999/6561, 11-12=2156/4867,
9-11=2255/4958
WEBS 3-15=310/273, 4-15=83/662, 4-14=963/1977, 5.14=690/530, 6-12=671/529,
7-12=.960/1974, 7-11=-84/662, 8-11=-311/273
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=i 60mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=3.0psf, h=15ft; B=30f1; L=30ft; gave=41t; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water Bonding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about Its center.
6) This truss has been designed for a 10.0 self bottom chord live load nonconcument with any other live loads.
7) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001E uplift atjoint(s) except Gt=lb)
2=1285,9=1285.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 245 lb down and 317 Ito up at
7-0-0, 166 It, down and 166 Ito up at 9.0-12, 1661E down and 166 lb up at 11-0-12, 166 lb down and 166 go up at 13-0-12, 166 to
dawn and 1661b up at 15.0-0, 1661E dawn and 1661b up at 16-114,1661b down and 1661b up at 18-11-4, and 166 Ib down and
1661b up at 20-114, and 2451b down and 317 Ib up at 23-0-0 on top chord, and 3661E down and 133 Ito up at 7-0-0, 821b down at
9-0-12, 821b down at 11-0-12, 821b down at 13-0-12, 821b down at 15-0.0, 821E down at 16-114, 82 Ib down at 18-11-4, and 82
lb down at 20-114, and 3661E down and 133 lb up at 22-114 on bottom chord. The design/selection of such connection device(s)
is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
`,`,O�PS1 A�aq<B�pi
ENS$.
No 39380
= D: :crz
411
Q
pO�s�O N A" �?�
Thomas A. Pi PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August 26,2019
e
,.AQRI ING -Venly Oe-gn parmnemrs antl Rc'AO IIDTES Oh T915 AIIOI:IGLUDED MITEK REFERE JC P4Ge' hhl.-473 rev. 1OU3 2015 BEFORE USE.
Design valid for use ony with MiTeM® connectors. This design is based only upon parameters shown, and is for an individual building component, not L}
a Buss system. seem use. We building designer must venythe appfrabiny of design parameters end property incoryonste this design into the overall �r�
buildingdesign. Bracing indicated is to premed buckling ofindihdual tress web andlor chord! members any. Addenonsumpmaryandpermanentbracing MiTek
is afways required for sdabllity and to prevent collapse with possible personal injuryand propeM damage. Forgenem guidance regaroing Ne
fabncstion. storage. delivery, interim and bmddit ofimseds and truss systems, sea ANS&B711 deahyCMeda, DSB49 and SCSI Building Component 6904 Parke East Blvd.
aaferyrnformation a bble Brun Truss Plate In9dute,218N.Lee SVeet,afte312,Alexandra.VA22314. Tampa, FL 36510
Job
Truss
Truss Type
Oty
Ply 138289-Williams Const: Shed
T17961497
J38289
A05G
Hip Girder
2
1
Job Reference joptionall
buss. Ft. Pierce, FL J494G
8.240 s Jul 14 2019 MiTek Industries, Inc. Man Aug 2613:04:33 2019 Page 2
ID:PHC 4FwUxEceZmzHcuyOvpyjzkq-MfMOZZVe 7TnUtf4ic4ZPA9q_KMkA4000TGDyRyIzPC
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pip
Vert: 14=60, 4-7=-60, 7-10=60, 16-19=20
Concentrated Loads (lb)
Vert: 4=-172(F) 7=172(F) 15=327(F) 11=327(F) 22=121(F) 23=121(F) 24=121(F) 25=-121(F) 26=121(F) 27=-121(F) 28=-121(F) 29=59(F) 30=59(17)
31=-59(F) 32=59(F) 33=59(F) 34=59(F) 35=-59(F)
®/.APII:G Veiny desgn parameters antl REA111IF3 1110114NU INOLUOEOWEK111111=1r. 3E 4A,rW3rev. 10,03Q0f5 BEFORE USE
Design valid mr use only with Mdelatconnectors. This design is based ony upon parameters shown, and is for an indiNdual biding componeM, not
a moss "am. Before use, the building designer must venyihe applicability of design parameters and properly incorporate this design into the oveall � S
buildingdesign. Baling indicated is to prevent budldng of indiwdual toss web andlor Nord members miry. MdNonal tempoary and permanent broom, MITOIC
is afweys requiredfor stabilMy and to plawort Whiffs Wirt possible personal injury and property damage, Forgenealguidanceregamigthe
faineagon. storage. delivery. median and baling ofhusses and buss systems, see ANSI?%1 Quality Coll DS&89 and BOSf Building Component 6904 Parke East BNd:
Safetylnformation available horn Truss Plate toduse, 218 N. Lee Siren, Sude 312. Macaronis, VA 22314. Tampa, FL Seen
Job rugs
Truss Type
Oty
Ply J38289-Nfilliams Const.Shetl
T17961498
J38289 ZCJ1
Jed -Open
8
1
Job Reference (optional)
Last coast l russ, Ft. Plence, eL J4U4b
8.240 s Jul 14 2019 MiTek Industries, Ind. Mon Aug 26 13:04:34 2019
0-11
a-11-0-0
l
Scale: 1.5 =1'
Plate Offsets(X,Y)—
(2:0-1-2,Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Udell
Ud
PLATES GRIP
TOLL 20.0
Plate Gnp DOL 1.25
TO 0.51
Vert(LL)
0.00
5
>999
240
MT20 244/190
TOOL 10.0
Lumber DOL 1.25
BC 0.08
Vert(CT)
0.00
5
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matnx-MP
Weight: 6 lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SIG No.3
REACTIONS. (Ib/size) 3=35/Mechanical, 2=29710-8-0.4=-65/Mechanical
Max Hoe 2=91(LC 8)
Max Uplift 3=35(LC 1), 2=-363(LC 8). 4=65(LC 1)
Max Grav 3=64(LC 8), 2=297(LC 1).4=111(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 260(lb) or less except when shown.
BRACING.
TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purling.
BOT CHORD Rigid ceiling directly applied or 104)-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh BCDL=3.Opsf; h=15ft; B=30f1; L=30ft; eave=oft; Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional); Lumber DOL=1.60 plate gdp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 pat bottom chard live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will Tn between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at joint(s) 3, 4 except Ut=1b)
2=363,
PSaA7r44
No 39380
1,11111115111,
Thomas A Albanl PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August 26,2019
®rt•.r .Y. JerirY wlYwsan.IPEAONOIFS ON THIS AND INCLUDED R:ITEK REF -PEACE PAGE ASI7I 'lr/in J]iarSeECC-e.'VSE
Design valid far use onry wah MTexW connectors. This design Is based arty upon parameters shown, and Is for An IAdMEual Wilding component, not ���
a W AS rymem. Before use, Me building designer must vedWhe appgcabiliy of design parameters and properly Irompofate Nis design into Me averall
buil0ingdesign. Bracing indicated is to prevent buckWg of lndMdual truss web andlor Nord members only. Addidonaltemporayandpermanentbrasing MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
Iamcatloa Storage. delivey.eledion and AGAIN oftresses and truss sy9ems, see ANSIMP11 Quality Cdreda, DS849 and SCSI Building Component 6904Parke East BNd.
SayefylnyorrneNon avalablefmm Tmss PlWetnstAN9.218N.Let Street, do3lZAl ndO.VA22a14. Tampa. FL 36610
Job
Truss
Truss Type
0ty
Ply J38289-NNliams Const.-Shed
T17961499
J38289
ZCJ3
Jack -Open
8
1
Job Reference o tionat
ImSS, Ft. Pierce, FL 34945
8,240 s Jul 14 2019 MiTek Industries, Inc. Mon Aug 2613:04:34 2019
Scale =1:122
Plate Offsets (X,Y)-
[2:0-0-2,0-0-01
LOADING (psQ
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vdeft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(-L)
-0.01
4-7
>999
240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.11
Vert(CT)
-0.01
4-7
>999
180
SCLL 0.0 '
Rep Stress Incr YES
WB 0.00
HOM(CT)
0.00
2
n/a
came
BCDL 10.0
Code FBC20177TP12014
Matrix -MP
Weight: 1316 FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (Ib/size) 3=53/Mechanical, 2=282/0-8-0, 4=18/Mechanical
Max Ho¢ 2=134(LC 8)
Max Uplift 3=32(1-C 5), 2=-257(LC 8)
Max GOD, 3=59(LC 13), 2=282(LC 1), 4=45(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All tomes 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-114 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES.
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=30ft; L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about As center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle a 6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. -
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3 except Ot=1b)
2- 257.
E NSF
No 39380
Off.WF
rrnnm"`
Thomas A Alban! PE No.39380
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa R. 33610
Date:
August 26,2019
lev9n raravlzl aantl READ NOTES ON THI54ND INCLUVEO 0TEH REF,:RENCE?AdE b:d-)lA.ov.+.,'2 I1 j54£FORE USE
Design vsM foruse onlywim MTeM Ovnect0m.This design is based onty upon pa2mMers shovm, and is for an individual wading component, not
a bass system. Before use, me building designer David witfythe applicobily of design parameters end propeM incorporate Nis design into Ise everdll
buildingdesign. Bmhg indicated is to prevent busking 0 hdMwW bass web armor Nord members only. AcRiMcnaltemporwyarMpennanembradeg MiTek'
is always rquawl for slabilxy and to prevent collapse win possible personal injury and pmpeM damage., Forgenece guidance regaining Ole
fabdwRon,Storage. delives, erection and bradng clavicles and bassrysems. we ANSI?Plt Quality Criteria, DS"9 and SCSI Building Cmponenl 091 Parke East Blvd.
Sahylnfamagon awflable Rom Truss Plade InsxNe. 218 N. Lee server, Suite312, Alera m. VA22314. Tampa, FL 3NIO
Job
Truss
Truss Type
Oly
ply J38289-Williams Canst: Shetl
T17961500
J38289
ZCJ5
Jack -Open
e
1
Job Reference (optional)
8.240 s Jul 14 201 g MI leK industries, Inc. Mon Aug 2613:04:36 2019 Pagel
IDTHC_4FwU.EOeZmzHcuyQvpyjzkgnEIBBaXXH2sMLKNMkeGRpnP1XSuNcx QVtZmyjzP9
Scale =1:163
LOADING (Pat)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl LJd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.50
Vert(L-) -0.02
4.7 1999 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.36
Ven(CT) -0.05
4-7 >999 180
BCLL0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
3 file file
BCDL 10.0
Code FBC2017TrP12014
Mamx-AS
Weight: 191b FT=O%
LUMBER.
BRACING.
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied.
REACTIONS. (lb/size) 3=117/Mechanica1, 2=344/0-6-0, 4=52/Mechanical
Max Harz 2=179(LC 8)
Max Uplift 3=.90(LC 8). 2=-261(LC 8)
Max Grav 3=126(LC 13), 2=344(LC 1), 4=84(LC 3)
FORCES. (Ib)-Max. Comp./Max. Ten. -All forces 250(I1b) or less except when shown.
NOTES-
1) Wind: ASCE 7.10: Vul1=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCOL=3.0psf, h=15f; B=30ft; L=30f1; eave=411; Cat.
II; Exp C; Encl., GCpi=0.18; IVWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load ndnconcunenl with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) 3 except Qt=lb)
2=261.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chard and 1/2r' gypsum
sheetrock be applied directly to the bottom chord.
`,,OoPStA.T44flee
'
s .'•GENS'.9.y�i
No 39380
WF
OR
E � %N
�,�SS,�NA; L4� •,
Thomas A Alight PE No.39380
MiTek USA, Inc. FL Cert6634
6904 Parke East Bird. Tampa FL 33610
Date:
August26,2019
n rramelws and RE DAO Tea ON TtiIS A 4D INCLUDED KIrEK REFEAEbLE RA GE 4:IF 7473 rur. 10r03/2615 v"f 9— ISE
Design valid for use onywgh MRek®connectors. This design Is based any upon parameters shown, and is fdran individual building component, not
a Wss system. Before use, the building designermustwdy the applicoilyof design parameters and pmpedy NcoMorale this design lntothe swept
t
buildingdesign. Bracing ineiwted is to prevent buckling of lOMAdual puss web and/or Nord members only. MthronallempomryaMpomenentbracing MiTek'
is always required for Msbilly and to prevent cWapse with passible personal iqugmd property damage. For garland guidance regarding the
fabrication, smuts. deM , erection and breung oftrusses and buss systems. use ANSIRPII Quality CdMdd, DSBA9 andBCSl Building Component 6904 Parke Fast BiW.
Sffieylnfendshon ava able tram Tuss Plate Ins Oe, 21e N. Lea Street. Suge 312. Nexandrfe, VA22314. Tampa. FL 36610
Job
Truss
Truss Type
any
Ply J38289-Williams Const.Shetl
T17561501
J38289
ZEJ7
Jack -Open
18
1
Job Reference (optional)
Truss, I-t. fierce, cL 64a
8,240 s Jul 14 2019 MTek Industries, Inc. Mon Aug 26 13:04:37 2019 Page 1
ID:PHC_4FwUxEDeZmzHcuyOvpyjzkq-FObWPwY92M_DyUymS9VzOJThxh363BnJ4E0SCyjzP8
Scale =1:204
Plate Offsets (X Y)--
[2:0.0-14 Edge].
LOADING (psf)
SPACING. 2-0-0
CST.
DEFL.
in
floc)
Well
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.95
Vert(LL)
0.09
4-7
>891
240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
SC 0.81
Vert(CT)
-0.21
4-7
>388
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
2
Na
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -AS
Weight: 25 lb FT=0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (Ib/size) 3=181/Mechanical,2=419/0�8.0,4=79/Mechanical
Max Hom 2=225(LC 8)
Max Uplift 3=-145(LC 8). 2=-281(LC 8)
Max Grav 3=192(LC 13), 2=419(LC 1). 4=122(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
NOTES.
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=30ft; L=30ft; eavess4ft; Cat.
It; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gnp DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to amount for these factors.
3) Plates checked for a plus or minus 0 degree rotation about As center. -
4) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
will fit between the bottom chord and any other members.
6) Refer to girders) for truss to truss connections.
7) Pmvide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except 6t=1b)
3=145,2=281.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
P51A IIIFq<e���i
No 39380
0a;
SS/ONAl ��%%%.
Thomas A Albsnl PE No.39380
MTek USA, Inc. FL Cent 6634
6904 Parke East BW. Tampa FL 33610
Date:
August26,2019
�.'ANvItiG.V:rily dosiy�p:e...•f]_n4 READ bores 0.A rNb ANDM6LWED MITER PCFEREVCE PAGEfi947473 rev 1d'a}:d15BEFOG£l':-
Design valid for use Only with MmeloDconnectors. This design Is based only upon parameters shown, and is for an incMdual balding component, sea
a Was system. Before use, the building designer must verythe applicability of deep parameters and property incorporate We design into the overall
buiWingdesign. Bracing gMiwtetlis(o preuxM bucWing dfinS4dual Wssweb andlof NaMmembers any Adddi.millempearyandpermanembracing iwiTek'
is always requiretl for stabOy and to prawns collapse wi h possible personal Injuryand property damage. For general guidance regarding the
fabrication,storage. delivery,ereden and bowing dimsses and tress systems. we ANSVIPI1 Duality Canada, DSB49 and SCSI Building component stow Parke East Blvd.
asset, handmaiden available from Truss Plate lnmhute,218 N. Lee street, Sulte 312. Alexandria, VA 22314. Tampa, P. 36610
Job
Tess
Truss Type
Gty
ply J38289-Williams Const: Shed
T17%1502
J38289
ZHJ7
Diagonal Hip Girder
q
1
Jab Reference (optional)
East Coast Truss, Ft. Pierce, FL 39946
8.240 s Jul 142019 M7ek Industries, Inc. Mon Aug 26 13:04:38 2019
Scale = 123.3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
([cc) Well Ud
PLATES . GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.65
Vert(L-) -0.07
7-10 >999 240
MT20 2441190
TCDL 10.0
Lumber DOL
1.25
BC 0.49
Vert(CT) -0.08
6-7 >999 180
BCLL 0.0
Rep Stress Ina
NO
Wit 0.33
Horz(CT) 0.01
5 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 431b FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied Or 9-11-9 cc bracing.
WEBS 2x4 SP No.3
REACTIONS. fib/size) 4=136/Mechanical,2=552/G-lG-15,5=297/Mechanical
Max Hoe 2=224(LC 24)
Max Uplift 4=-111(LC 8). 2=457(LC 8), 5=-105(LC 8)
Max Grav 4=136(LC 1), 2=613(LC 28), 5=344(LC 28)
FORCES. (Ib) - Mar. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOPCHORD 23=-920/259
BOTCHORD 2-7=331/851, 6-7=331/851
WEBS 3-7=0/256, 3-6=906/353
NOTES.
1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=30ft; L=30R; eave=4ft; Cal.'
II; Exp C; Encl.. GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 loaf bottom chord live load nonconcument with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at joint(s) except (P=1b)
4=111, 2=457, 5=105.
7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 104 lb down and 46 to up at
4-2-15, 1041b down and 46 Ito up at 4-2-15, and 144 Is down and 113 Ib up at 7-0-14, and 144 lb down and 113 lb up at 7-0-14 on
top chord, and 63 Is down and 631b up at 1-4-15, 63 Is down and 63 Ito up at 1-4-15, 381b down and 31b up at 4-2-15, 38 Ib dawn
and 31b up at 4-2-15, and 46 Ito down at 7-0-14, and 46 lb down at 7-G-14 on bottom chord. The design/selection of such
connection devices) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=60, 5-8=20
Concentrated Loads (Ib)
Vert: 12=65(F=-33, B=-33) 13=75(F=38, B=38) 14=5(F=3, B=3) 15=47(F=23, B=23)
014111111111111111
A.
No 39380
* _
�9 w�
Thomas A Albans PE No.39380
MTek USA, Ina FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
August 26,2019
LVARNIN..V-1,pea9npara,nero,;:,dF''AP,;ODESO.NrW5AND,,VCLUDED.MI/EXREFERENCEFAGSNF.1:23rev. Mhi 2015eE`OREUSE.
Design said for use onywdn Wake connectors. This desgn is based miry upon parameters shown, and is for an individual building component, not
a loss Systems Before use, the building designer must swirly the appftability of design parameters and properly inooRorme Nis design into Ole overall m�
buikingdra esgn. Bdng Indicated is to present buckling of individual truss web aMlm courd members any. Addrionaltemporaryandpml eanertbracing MiTek'
Is always regubed for Stability and to present collapse with possible personal injury and pmpeny damage. For general guidance regarding Me
fabncabon,storage,delivery,madion and baring oftruseesand muss systems, see ANSVTPlf dusty Comda, DSB49 and BCS1 Building Component 6904 Parke Fast BIM.
SAey1marration andable ram Toss Plate InAROe, 218 N. Lee 6 met, B Ae 612. Alexandria, VA 22314. Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
10 3/a' Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
O'yT1 fi r
I
For 4 x 2 orientation, locale
plates 0- Nd' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
th
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI1-rPl1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
I I dimensions shown in ixteenths
(Drawings not to scale)
1 2 3
TOPCHORDS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
O 2012 MiTek® All Rights Reserved
M1W
M!Tek
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal orX-bracing, is always required. Sea SCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, Individual lateral braces themselves
may require bracing, or altemative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials an inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each lace of truss al each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/IPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSIrrPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19 % at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a nonstructural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load defiection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
In all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pudins provided at
spacing indicated on design.
14' Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling Is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
Is not sufficient.
20. Design assumes manufacture in accordance with
ANSUTPI 1 Duality Criteria.