HomeMy WebLinkAboutSUBMITTED PAPPERWORKSCANNED BY St. Lucie County PUBLIC WORKS DEPARTMENT TO: FROM: MEMORANDUM Martha Schurmann, Building Division Charles A. Cangianelli, Building & Zoning Manager SUBJECT: St. Peters Lutheran Church, 9127, DATE: August I1, 2000 Engineering has reviewed the paving and drainage as-builts for this project and are accepting them for completion at this time. A copy of the Engineer's certification is attached for your records. If I can be of further assistance to you in this matter, please let me know. CAG/sm cc: " Donald West, P.E., County Engineer Dennis Murphy, Asst. Community Development Director Jan Urso, Zoning Supervisor U AUG 112055 St. Ituoia Couniy Public VJorks Stephen Cooper, P.E. & Associates, Inc. Consultant Engineers 209 NE Sagamore Terrace Port St. Lucie, Florida 34983 (561) 879-7779 FAX (561) 878-5151 •Civil Engineering •Site Planning *Environmental Permitting .i, August 9, 2000 Mr. Donald West, P.E. St. Lucie County Engineer 2300 Virginia Avenue Ft. Pierce, Florida 34982 RE: St. Peter's Lutheran Church - Final Stormwater Certification Dear Mr. West; Please allow this letter to serve as the required certification that the above referenced project was constructed in substantial conformance with the approved site paving, grading and drainage plans completed by this firm. This certification is based on periodic site inspections conducted by this firm including inspection of the drainage system, subgrade, and concrete pavement. Any deviations from the approved plans are considered minor and are noted on the "As -Built" survey completed and certified by Ford, Armenteros and Manucy, Inc.. This certification is also based on soil test results completed by Ardaman and Associates, Inc. which were certified to be in conformance with St. Lucie County standards, as required in the plans and specifications. If you have any questions regarding this final certification letter, please contact this office at the above address. cc: Mark Brandel 07/21/?000 08:32 5614645251 GALE INSULATION„ _. _ ... _. PAGE 01 JUL 212000 St. Lucie County Public Works sale - insulation and speclaltil" e MA= Company CERTIFICATION OF INSULATION R INSULATION INSTALLED ON INMIOR WALLS R-,V— INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot Block Sub -Div PERMIT ADDRESS: ,'vc> nL. DATE OF COMPLETION: 9! ATOSTED BY Mirrors • Shelving Shower Enclosures STATE OF FLORIDA, COUNTY OF ST. LUCIEp JHE FOREGOING INURUMENT WAS ACKNOWLEDG D• EFORE ME THIS DAY OF , 2000, BY , WHO IWPER 0NALLY KNOWN TO ME. F JANICESTINNETT Ya Mr -Sr T,,V2 o3 NOT PUBLIC, STATE OF FLORIDA ' ��! NO CC 874490 {�'6s�.o�.y Yn 1104rr 1.0. 3490 er Avenue - Ft erce. Florida 34982 Ft. Pierce (561) 465-9191*Vero Beach 1 (56(561)859-15140 Stuart (561 ) 283-3151 • FAX (561) 489.6758 woeius JUL 312000 SL facie Coun-�.,,,� Public' - a0e- r-� r Insulation and speclalties a MASCO Company Mirrors - Shelving Shower Enclosures FICATION OF INSULATION R- ,30 INSULATION INSTALLED IN CEILING AREAS LEGAL:- Lot Block Sub -Div PERMIT, .jw9a DATE OF COMPLETION: 7l ATCSTED BY STATE OF FLORIDA, COUNTY OF ST. LUCIE,) HE FOREGOING INSTRUMENT WAS ACKNOWLEDGED-PEFORE ME THIS a92DAY OF DL� , 2000, BY , WHO IWPER90NALLV KNOWN TO ME. ,JANICE STINNETT � aiJ 1 fJ '�2l1Q My Comm Fi@. 91:!W2003 NOTA PUBLIC: STATE OF FLORIDA wnuc �, CC 874490 ^ O _[ //wr.m n omr I.D. 3490 Oleander Avenue - Ft. Pierce, Florida 34982 Ft. Pierce (561) 465-9191 - Vero Beach (561) 589-1514 - Stuart (561) 283-3151 0 FAX (561) 489-6758 Component Performance Method for Commercial Buildings Form 400E-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME_ST. PETERS LUTHERN CHURCH_ PERMITTING OFFICE: ADDRESS: _FT. PIERCE _Fort Pierce CLIMATE ZONE: 6 OWNER: _ST. PETERS LUTHERN CHURCH_ PERMIT NO: _99-0000 AGENT: JURISDICTION- N0:_661100 BUILDING TYPE: Assembly. CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _11900 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 17 COMPLIANCE CALCULATION: LF.1"40 oybi-'. ENVELOPE PERFORMANCE OTHER ENVELOPE REQUIREMENTS LIGHTING INTERIOR LIGHTING LIGHTING CONTROL REQUIREMENTS HVAC EQUIPMENT COOLING EQUIPMENT 1. EER IPLV HEATING EQUIPMENT 1. Et DESIGN 26.97 15000.00 AIR DISTRIBUTION SYSTEM INSULATION 1. Unconditioned Space REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT PIPING INSULATION REQUIREMENTS 9.00 7.50 1.00 REQUIREMENTS 6.00 ------------------------------------- - COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Florida Energy Efficiency Code. PREPARED BY: DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE: I hereby certify(*) that the system des Energy Efficiency Code. SYSTEM DESIGNER - ARCHITECT MECHANICAL•�wn PLUMBING ELECTRICAL: SORT cT i i irIP ci aAQAA LIGHTING NUMBER OF ZONES: 1 CRITERIA RESULT 66.22 PASSES PASSES 23800.00 PASSES PASSES 8.50 PASSES 7.50 PASSES N/A 4.20 PASSES Review of the plans and specifica- tions covered by this.calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with - Section 553.908, Florida Statutes'. BUILDING OFFICIAL: DATE: is in compliance with the Florida REGISTRATION/STATE (*) Signature is required where Florida Aiw�jrequires design to be performed by registered design professionals. Typed n es and registration numbers may be used where all relevant information is obtained on signed/sealed plans. • BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401.- ----- GLAZING --ZONE 1------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) ---------- ------------------------ ---- ---- ---- -------------- -North Commercial 1.31 .01 0 None 168 South Commercial 1.31 .01 0 None 72 East Commercial 1.31 .01 0 None 80 West Commercial 1.31 .01 0 None 96 Total Glass Area in Zone .1 = 416 Total Glass- Area_ = 416 _ 402.------WALLS--ZONE1------------------------------------------------ ---- Elevation Type U Insul R -------------------------------- ----- ------- Gross(Sgft) ----------- --------- North 5/8"Stco/8"CKU/3/4"ISO BTWN24"oc 0.149 4 1190 South 5/8"Stco/8"CM[J/3/4"ISO BTWN24"oc 0.149 4 1190 East 5/8"Stco/811CMU/3/4"ISO BTWN24"oc 0.149 4 1000 West 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4 1000 Total Wall Area in Zone 1 = 4380 Total Gross Wall Area = 4380 403.------DOORS--ZONE 1------------------------------------------------ --- Elevation Type U ----- Area(Sgft) ------- --------------------------------------------------- North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 42 Total Door Area in Zone 1 = 42 Total Door Area = 42 404.--- ROOFS --ZONE 1------------------------------------------------ --- Type Color U Insul R ------ ------------ Area(Sgft) ---------- ------------------------------------ Mtl Bldg Roof/R-19 Batt Medium .051 19 11900 Total Roof Area in Zone 1 = 11960 Total Roof Area = 11900 405.--- FLOORS -ZONE 1------------------ --- ---- ----- ------ --- --- Type Insul R ------- Area(Sgft) ---------- ---=-------------------------------------------- Slab on Grade/Uninsulated 0 11900 Total Floor Area in Zone 1 = 11900 Total Floor Area = 11900 406.--- INFILTRATION ---------- -------------------------------- -- --- Infiltration Criteria- in 406.1.ABCD have been met. ICHECR MECHANICAL SYSTEMS CHECK -------- ----- ------- ---- ----- ----------- -------------------------- ---- --- HVAC load sizing has been performed. (407:1.ABCD) 407------- COOLING SYSTEMS------------------------------------------------ --- Type No Efficiency IPLV Tons ---------------------------- ------------- ------_------------- l. Air Cooled ( >= 65,000 Btu/h 4: 5.0 0 16.67 408------- MATING SYSTEMS -------------------------------- ---------------- --- Type No Efficiency BTU/hr ------------------------------ ------------- ----- 1. Electric Resistance 4 1 62840 409'.------VENTILATION -------------------------------------- --------- --- - 1Ventilation Criteria in 409.1.ABCD have been met. CHECK 410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- --- CHECK ------------------------------------------------------------ ---- --- Duct sizing and design have been performed. (410.1.ABCD) AHU Type Duct Location R-value ---------------------------------------------------------------- 1. Packaged Constant Volume Unconditioned Space 6 CHECK ----------- ---- ---------- ----- -------------- ---------------------- --- Testing and balancing will be performed. (410.1.ABCD) 411------ PUMPS AND PIPING -ZONE ----------------------------------------- --- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE 1--------------------------------------- --- Type . R-value/in Diameter Thickness --------------- ---- - 412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons ELECTRICAL SYSTEMS CHECK 413------ ELECTRICAL POWER DISTRIBUTION -------------- =_------------- ----- --- Metering criteria in 413.1.ABCD have been met. 414.-----MOTORS --------------------------------------------------- ----- --- Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1-------------------=------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Classroom/ 1 On/Off 34 15000 11900 Total Watts for Zone 1 = 15000 Total Area for Zone 1 = 11900 Total Watts = 15000 Total Area = 11900 CHECK Lighting criteria in 415.1.ABCD have been met. ----------------------------------------------------------------- ----- --- operation/maintenance manual will be provided to owner.(102.1) ---------------------------------------------------------------------------- PROJECT TITLE ST. PETERS LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION Fort Pierce BUILDING AREA(ft2):. 11900 BUILDING ENVELOPE' WALL ORIENTATION NNE E SE S SW W WALL 1190 1000 1190 1000 GL 168- 80 7.2 96- SC 0:010 0.010 0-010 0.010 PF 0.00 0.00 0.00 0.00 VLT 0.00 0.00 0.00 0.00 Uof 1.310 1.310 1.310 1.310 W Uo 0.15 0.15 0.15 0.15 He 21.00 21..00 21.00 21.00 IP 3 3 3 3 L O A D S HEAT 0.873 0.513 0.525. 0.548 COOL 6.333 5.768 7..596-. 4.819 SUM 7.205 6.282 8.121 5.367 ******** PASSES. ******* WEIGHTED AVER. NW DESIGN.CRITERIA 0.09 0..312. WWR - WWR --- 0.01 0.500 0.00 0.00 0.00 N/A 1.31 1.150 0.15 0.371 21.00 1 3 N/A TOTAL 2.459< 4.012 24.516< 62.205 26.975< 66.216 OTHER ENVELOPE REQUIREMENTS MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN CRITERIA Percentage of Roof Area in Skylights MAXIMUM ALLOWABLE Uo: 0.000 = 0.0000 Roof 0.051 < 0.0868 u ******** PASSES ******* PROJECT TITLE ST. PETERS LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 11900 LIGHTING SYSTEM PERFORMANCE BUILDING DESIGN : Interior Lighting Power 15000 W 1.26 W/Gross7ft2: Exterior Lighting Power 0 W INTERIOR LIGHTING CRITERIA: Space No. Type Area Clg Ht Spaces AF UPD PB LPB Tatar LPB 3 11900.0 10.0 1 11 1.00 2.00. 2.00 23800' 23800 Unit Power Density Interior Lighting Power Allowance 2.00 .W/Gross ft2. 23800 W ******** PASSES ******** EXTERIOR LIGHTING CRITERIA: AREA AREA AREA OR ALLOWANCE CODE DESCRIPTION LENGTH WATTS .Exterior Lighting Power Allowance 0.00 W **** Not Applicable **** LIGHTING SYSTEM CONTROL REQUIREMENTS: TOTAL EQUIVALENT SPACE NO. CONTROLS CONTROL POINTS NO. DESCRIPTION AREA TASKS, TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA 3 Classroom/ 11900.0 1 On/Off 34 0 34 > 10 ******** PASSES ******** PROJECT TITLE ST. PETERS LUTHERN.CHURCH BUILDING TYPE Assembly BUILDING LOCATION Fort Pierce BUILDING AREA(ft2): 11900 HVAC SYSTEM REQUIREMENTS: Cooling System Type Measure #1 #2 Minim. #1 Minim. #2 System Eff.#1 System Eff.#2 Result for #1 Result for #2 Air Cooled. EER, IPLV 8.50 7.50 9.00 7.50 PASSES PASSES Heating System Measure Minimum Req. Efficiency Result Ele. Resis. Et 1.00 N/A PASSES ******** AIR DISTRIBUTION. SYSTEM INSULATION REQUIREMENTS: Zone # Duct Location Minimum R-Value Design R-Value Result 1. Unconditioned Space. 4..20 6.00 PASSES ******** PASSES.******** PROJECT TITLE. ST. PETERS'LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION :. Fort. Pierce BUILDING AREA(Et2): 11900 WATER HEATING SYSTEM REQUIREMENTS System Type Measure Minimum EF / Et Maximum SL Design EF / Et Design SL Result **** Not Applicable **** PIPING INSULATION REQUIREMENTS: Pipe Insulation Thickness(in) System Type- O.D. (in-) Minimum -Reg. - Design- Result **** Not Applicable **** PAUL WELCH I1TC. Mechanical:- Electrical • Civil - Engineering 198.4S.W. Biltmore SL #114 Port SL Lucie, FL 34984 Phone (407) 785-9888 FAX (407) 785-99M date: "JU12 ?TISIOKO ROOM: SLDc-1 AREA: 11100 SF sheet of I JOB • ST- Pt=TLe UA R E ILAr7 ZONE: N WALL.. ............. ltj0 SF X 31(z$ _ 43SO S WALL ............... 1Igo SF X. ojs� l= WALL ............... 1000 SF x 4-% = 41 to 0 WALL ............... 1000 SF x ('94 = (,, S 4 0 fJ GLASS .............. (&s SF x 44 _ -13 2 _S__GLASS .............. `j L SF x 41 = 3S2 O GLASS .............,. °o SF X l l Z 6 0 GLASS- .. ........... q 4 SF x ( _ 13'7 S 4- ROOF ................... 11 q 00 SF x 2 2 = Z& 1 n U' LIGHTSS................. 23$00 W x 3.41 PEOPLE..................... 21 ° x Soo INFIL. (62--89)........... 2oO afm x, s.+ = 22(0 a 0 D Sub Tota•1 = 5*e duct losses. — 24514 TOTAL = s 15 z ut s e C3i - 115 tom k'*J;+s 10-tay. u..a `I� S -tan Mw'lt — - Ardaman & Associates, Inc. 1017 SE Holbrook Court Port St. Lucie, Florida 34952 (561) 337-1200 DATE OF TEST: 12/21/99 PROJECT: St Peter Lutheran Church SUBMfrfED TO: Mark Brandel FIELD DENSITY DATE REPORTED: NSAXIMUM DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557/AASHTO T-180 FIELD DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-2922/AASHTO T-238 FILE NO. 98-5733 Location of Test: OMC Max. Mo'Isture Field % of Job El Church Building Pad %Max. fill material (IbJcu.fLI) of Test % (IbJcu.tt) Den. Dry 1 10' east of center of pad 11.6 113.9 9.7 112.1 98" 98 O' to -l' FS 2 same as test #1 11.6 113.9 10.3 113.1 99'• 98 -V to -2' FS 3 10' west of center of pad 11.6 113.9 10.8 112.3 99•' 98 O' to -1' FS 4 same as test #3 11.6 113.9 11.5 113.7 too** 98 -l' to -2' FS '• retest of failing tests of 12/17/99 ' Indicates density test does not meet minimum density requirement •• Indicates retest - density meets or exceeds minimum density requirement F-soil directly below footing; F3-soil under floor slab; GA -soil in general compacted area; PAV-soil below stabilized section; PSSG-stabilized subgrade; PB-pavement base; NSSG-non stabilized subgrade; RSroadway subgrade; TOP -top of pipe; BOP -bottom of pipe �Lc6;z./> Roberto E. Balbis, P.E. AS MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMrrrEO AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBUCATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM 08 REGARDING OUR REPORTS IS RESERVED PENDING OUR WRTTfEN APPROVAL — ' Ardaman & Associates, Inc. 1017 SE Holbrook Court Port St. Lucie, Florida 34952 (561) 337-1200 FIELD DENSITY TEST REPORT DATE OF TEST: 12/22/99 DATE REPORTED: 12/23/99 FILE NO. 98-5733 PROJECT: St. Peter Lutheran Church SUBMITTED TO: Mark Brandel MAXIMUM DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557/AASHTO T-160 FIELD DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-2937/AASHT0 T-204 Location of Test OMC Max. Moisture field TestChurch Building Pad %No.Natural ME[ Grade QbJcu.ft) of Test % (IbJcuft) Dry 1 Center of north wing 12.0 107.2 9.9 107.5 100+ 98 -2' to -3' FS 2 Center of west wing 12.0 107.2 11.4 104.9 98 98 -2' to -3' FS 3 Center of east wing 11.6 113.9 11.6 112.1 98 98 -2' to -3' FS 4 Center of south wing 11.6 113.9 11.0 111.9 98 98 -2' to -3' FS • Indicates density test does not meet minimum density requirement •' Indicates retest - density meets or exceeds minimum density requirement F-soil directly below footing; FSsoll under floor slab; GA -soil in general compacted area; PAV-soil below stabilized section; PSSGslabilized subgrade; P&pavement base; NSSGnon stabilized subgrade; RSroadway subgrade; TOP -top of pipe; BOP -bottom of pipe 2c Irz. /t,.; Roberto E.-Balbis, P.E. Y ii AS MUTUAL PROTECTION TO CUENTS, THE PUBUC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL V iN Ardaman & Associates, Inc. 1017 SE Holbrook Court Port St. Lucie, Florida 34952 (561) 337-1200 FIELD DENSITY TEST REPORT DATE OF TEST: 12/22/99 DATE REPORTED: 12/23/99 FILE NO. 98-5733 PROJECT. St. Peter Lutheran Church SUBMITTED TO: Mark Brandel MAXIMUM DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557/AASHTO T-180 FIELD DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-2922/AASHT0 T-238 TestChurch Location of Test Building Pad material OMC %No.fill Max. (IbJcu.ft) Moisture of Test % Feld (IbJcu.ft) Dry 9HI 1 40' north of center of pad 12.0 107.2 11.0 106.1 99 98 0' to -1' FS 2 same as test #1 12.0 107.2 10.9 106.6 99 98 -V to -2' FS 3 40' south of center of pad 12.0 107.2 11.2 106.7 100 98 O' to -l' FS 4 same as test #3 11.6 113.9 10.2 113.3 99 98 -1' to -2' FS 5 75' west of center of pad 12.0 107.2 10.5 107.5 100+ 98 O' to -1' FS 6 same as test #5 11.6 113.9 11.4 112.7 99 98 -1' to -2' FS 7 75' east of center of pad 11.6 113.9 11.2 113.6 100 98 0' to -l' FS 8 same as test #7 11.6 113.9 10.7 111.6 98 98 -l' to -2' FS 9 20' southwest of northeast corner of pad 12.0 107.2 11.3 106.0 99 98 O' to -l' FS 10 20' northeast of southwest corner of pad 12.0 107.2 11.8 105.4 98 98 0' to -1' FS • Indicates density test does not meet minimum density requirement •• Indicates retest - density meets or exceeds minimum density requirement F-soll directly below footing; FS-soil under floor slab; GA -soil in general compacted area; PAV-soil below stabilized section; PSSG-stabilized subgrade; P&pavement base; NSSGnon stabilized subgrade; RSroadway subgrade; TOP -top of pipe; BOP -bottom of pipe Roberto E. Balbis, P.E. A c AS MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMFTTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL l11 Ardaman & Associates, Inc. 1017 S.E. Holbrook Ct., I Port St. Lucie, FL34952 l�+l� COwLED (407) 337-1200 E: E. MOISTURE; ---DENSITY RELATIONSHIP $ -200J- Pu aac pu Rxs PROJECT: St- _peter Lutheran. Church FILE NO.; gg g`LlicnEcou�afly,Fi'' REPORTEDTO: Mark Brandel' DATE:`' 12/13/99-- ' • MINE , ■MmE■M■►f0®RMWEEMEM ■■■EE■■■MEN� ■OM■EN■EWEEW ■■■■■■■EKE■►\\ ME■E■E■■M■N\\\1 - - . . - . •.. - • . \. M■■EM■■■■■■■■■■\\ ■■■■■■■■■■■■■■■\\!, ■■N■■■■■■■■■■■■■■\\ ■E■E■■E■■N■■■■OMEN. MEMO ■■■■■■■■■■■■■■■\\\. M■E■■■���Nommo■■■■M\\ ■■■■■■■■■■■■■■■■■■■■■\li ■■■■■■MM■ME■■EEM■M■E■■N ■ENEM■■■■ME■N■■M■■MEMENNI ■■EME■■■■■■N■N■■■■MEM■E\No 0 NONE■M■■■■■■■NE■■E■■MONENS\ ■■MO■■■■O■MOO■■■■■■■■NEE■\.\\► ■MEMO■■MEM■NE■ME■■■■■E■O■E\14 MEMO ■M■O■�O�O■O■■■■■■■E■EEO\\. ■E■■EEME■E■■■■■■■■■■N■■■■■■■`\ 1 T - - - By- -A L�, AS I MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES. ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF R WRIT AND APPROVAL FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPppVAI ®� Ardaman & Associates, Inc. 1017 S.E. Holbrook Ct. Port St. Lucie, FL 34952 f, .,•" (407) 337-1200 ,F MOISTURE - DENSITY RELATIONSHIP PROJECT: St. Peter Lut;hern Church FILE NO.: 98-5733 REPORTEDTO: Mark Brandel DATE: 12/14/99 • • ■ SOIL DESCRIPTION: ■■■■■■■■■■■■■■■■■■■■■■�\ MEEME■■■■■■■■■■■■■■■■■MN\ ■■■■■■■■■■■■■■■■■■■■■■■�\► MEMO ■■■■■■■■■■■■■■■■■■■■■\\ ■MEMO■■■MMM■M■■■MMM■M■ME■�► \ NEON EMEME■O■■M■MMEMEME■MM■M\\. MEMO ■■■E■■EMEMM■O■■■■■E■■E■�\\ By AS A MUTUAL PROTECTION TO CLIENTS. THE PUBLIC AND OURSELVES. ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS ANC AUTHORI. ]ATION FOR PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL ® Ardaman & Associates, Inc. 1017 S.E. Holbrook Ct. Port St. Lucie, FL 34952 (407) 337-1200 MOISTURE — DENSITY RELATIONSHIP PROJECT: St. Peter Lutheran Church FILE NO.: 98-5733 — REPORTEDTO: Mark Brandel DATE: 12/14/99 • • • &-mmmmomemEE • • ■O■■■■■■■■■R� NONE■■■■■■■■��\ - ' • - ■E■■■E■■■■E■►�� ■■■E■■■E■■NE■\\\ ■■E■E■E■E■EN■���. ■ENNEE■ENEE■EN�� NEENEE■■E■■■E■►�a. . - • It'. • • • - - • • • NEW \. ■ENE■■• ■EE■■■■\\. E■E■•-NEE►NE■E■■E E;■■■■■■■■E�■■NEE\�► ■t•�■E■EE��■NEE■�� EE■E■E■■■■EEE■■■NEE:•. ■■■NEE■E■■E■■■NEE■■►\�. ■■■■■■■E■■EEO■■■■■N■E\\ ■■■E■■■■■■■E■■■■■■■■E\\. ■■■MEN ■■■■E■■■■■■E■E■■RN ■E■■E■■■■E■■E■■E■E■■EON\\ ■■NNEN■■■■■■■■■E■■■■■ ■■■NNE■■■■E■■■■E■EE■NEE■\\. ■ENE■■■■■E■■■■■E■■■■■■■MEN ■EON■■■■■■■■E■■EE■E■E■■■■\.\\► ■■■■■■E■■NE■E■■■■■■■NEE■■■\\. ■■■■E■N■■■■■■E■■■■■E■■■■■MEN ■■■■■■■■E■■■■■■■■■■■■■■■■■■■\\ 1 1 AST.TTIIIR! /171f- By. _ AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES. ALL REPORTS ARE SUBMITTED AS THE CONFIDE4IAL ifP+.OPcPTV OF CLIENTS AND AUTHOg,. ZATION FOR PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS S IS RESERVED'PEI ING OUR WRITTEN APPROVAL lding - ia ' Ardaman & Associates, Inc. 1017 SE Holbrook Court Port St. Lucie, Florida 34952 (561) 337-1200 FIELD DENSITY TEST REPORT DATE OF TEST: 12/17/99 DATE REPORTED: 12/21/99 FILE NO. 98-5733 PROJECT: SL Peter Lutheran Church SUBMITTED TO: Mark Brandel MAXIMUM DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557/AASI TO T-180 FIELD DENSITY DETERMINED IN ACCORDANCE wrTH ASTM D-2922/AASHTO T-238 Location of Test OMC Max. Moisture Fleld TestChurch Building Pad %No.fill ME[ material QbJcuft) of Test % (IbJcuft) Dry 1 10' west of center of pad 11.6 113.9 13.1 110.0 97* 98 O' to -1' FS 2 10' east of center of pad 11.6 113.9 13.3 109.4 96• 98 -V to -2' FS 3 same as test #1 11.6 113.9 12.9 110.4 97* 98 0' to -1' FS 4 same as test #2 11.6 113.9 12.8 109.8 96 98 -1' to -2' FS * Indicates density test does not meet minimum density requirement •• Indicates retest- density meets or exceeds minimum density requirement F-soil directly below footing; FS-soll under floor slab; CA soil in general compacted area; PAV-soil below stabilized section; PSSGstabilized subgrade; P&pavement base; NSSGnon stabilized subgrade; RSroadway subgrade; TOP -top of pipe; BOP -bottom of pipe 02.CaT./11." Roberto E. Balbis, P.E. AS MUTUAL PROTECTION TO CUENTS, THE PUBUC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL �r ST. LUCIE COUNTY FIRE DISTRICT ` BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Ave Telephone (561)-462-2312 Fort Pierce, Florida 34950 Fax:: (561)-462-2323 TYPE OF PERMIT ( X ) New Construction ( ) Tenant Improvement ( ) Addition ( ) Renovation/alteration ( ) Shell Only Jurisdiction: St Lucie County Occupancy: St Peters Lutheran Church Address: Jenkins Rd Contractor: —Mark W Brandel Inc Contractors address: 2525 NE 131" Arch itect/Engineer: W T Patterson Building owner: St Peters Luthern Church Occupancy type: Assembly Gross sq. ft. 17009 sq ft Occupant load: Construction type ( NFPA-220) Type: F.P.B. B-99-169 Building Dept. 99100001 Number of stories: 1 Phone # 941-763-6796 City: Okeechobee, FL Zip: 34972 Phone #: 951-436-9721 Review date: 10-20-99 Automatic sprinklers: Net sq. ft. Based on: SBCCI: Type: NOTE 1. All revisions must be in compliance before the final inspection, or so noted. 2. The Fire Marshal required 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Failed inspections requirement payment of fee prior to scheduling of any further inspections. S. Permit fees are required to be paid in full prior to any inspections. 6. A copy of the required revisions have been transmitted to the Architect ( ) Contractor ( ). REVISIONS REQUIRED 1. A separate permit is required for the fixed fire protection system. The system shall be connected to the fire alarm system. 2. Provide emergency lights in the sanctuary and the vestibule. 3. A separate permit is required for the installation of the fire sprinkler system. The sprinkler system is required to be monitored by a monitoring company approved by this jurisdiction. Fire sprinkler coverage shall be above and below the ceiling level. 4. A/C ductwork penetrating rated wall assemblies shall have fire dampers installed accordingly. 5. Draftstopping is required at 3000 square foot intervals; 9000 square foot intervals when covered by fire sprinklers. 6. A minimum of one 2A-10BC rated fire extinguisher is required every 75' of travel distance. A 40BC extinguisher is required for the kitchen. Reviewed By: Date: October 20, 1999 Tony Liento Y ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 2300 VIRGINIA AVENUE FT. PIERCE, FL. 34982.5652 661-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE Ali ha Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permit involving the construction of new residence (single or multi -family). residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shelf not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. PROJECT NAME S . /' L!J !J OFFICE USE ONLY STREET ADDRESS .2 R- I- 6O01P-- PR NUMBER BEEN 1TFi✓rce A JZ 4 PERMIT NUMBER OCCP. TYPE CST. TYPE CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES ' CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED• col a e check of camnlete the aooroorite box) 1. STANDARD BUILDING CODE 1997 EDITION ASCE 7-95 ��THER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED PARTIALLY ENCLOSED_ OPEN BUILDING_ 3. BUILDING HEIGHT: 5915 Fr a. WIND SPEED USED IN BUILDING DESIGN: /50 MPH 5. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING Coos IDENnFIED IN LINER): G 9. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: 3:5,01 PSF 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: S ,O% PSF B. IMPORTANCEAISE FACTOR (OBTAIN FROM BUILDING CODE): # 87 . 9. LOADS: FLOOR /00_ PSF ROOFMEAD: 7T PSF ROOF/LIVE: 3C7 PSF 10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (cNEcN ONE) YES NO _ If NO, why? (attach explaination) 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES NO _ If NO, why? (atach expiainalion) 12. ARE COMPONENT AND CLADDING DETAILS PROVIDED iCHECK ONE) YES NO _ If NO, why? (attach expla(natlon) 13. MINIMUM SOIL BEARING PRESSURE: 2.500 PSF AS WITNESSED BY MY SEAL,1 HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME: 60, J- rf 17A- 450.J CERTIFICATION NO: 0 ez /� ' - fSFAL N.ERE] DESIGN FIRM: Gf/,T/fl�t�n.v DATE: - PSLOGOV FORM NO woad uJ �' 0a(Jd,1 BRANDEL Project : ST. PETER LUTHERAN CHURCH "Subject : WIND LOADS File Location : FT. PIERCE. FL. Date Eng. Desian Wind Pressure o TA9LE 6 1 Y Design wind pressures and forces are determined per equations given in table 6-1 Desi n wind loadin Structure t e E nation ' Main wind -force Flexible resisting system Buildings p q'Gf Cp qz : For windward wall @ Height z qh : For Leeward wall @ mean roof ht. Gf : Obtained by rational analysis Cp : given in Figure 6-3 Velocity Pressure Calculations az and ah velocity pressure qz and qh are calculated in accordance with section 6.5 qz = Velocity pressure @ height (z) qz = Constant • Kz • Kzt • V 2.1 qz = See wind pressure calculation table qh = Velocity pressure @ height (h) qh = Constant • Kh • Kzt • V 2 I Where: Constant = Numerical constant _ Y22 • [ ( Air density Ib/ cu ft) / ( 32.2 ft/s2 )] . _ [( mi/h )( 5280 ft/mi) • (1 hr/3600 s )] 2 = 0.00256 Mean Sea Level = 0.00 ft Air Density @ MSL = 0.0765 Ib/cu ft Category = I Importance Factor = 0.87 Exposure Category = C Alpha = 9.50 Z9 = 900.00 ft Basic Wind Speed = 150.00 mph Structure Height = 39.00 ft Width = 76.00 ft Depth = 182.00 ft Natural Frequency = 0.2000 Hz Damping Ratio = 1.0000% (Open terrain) 98130 9/21/99 WTP (Eq. 6-1) (C2) (Table C6-1) (Table 1-1) (Table 6-2) (Table C6-2) (Table C6-2) (Figure 6-1) Page 1 I r •BRANDEL Project : ST. PETER LUTHERAN CHURCH File : 98130 Subject : WIND LOADS Date : 9/21199 Location : FT. PIERCE, FL. Eng. : WTP Velocity Pressure Calculations az ICont 1 Where: Kz = Velocity pressure coefficient @ height z (C3a) = 2.01 •(Z/Zg) - 4(2/Alpha) for 15 ft <= Z <= Zg (C3b) = 2.01 • (15/Zg) • ^ (2/Alpha) for Z <= 15 ft = See wind pressure calculation table Kh @ h = Velocity pressure coefficient @ height h = 1.04 Kzt = Topographic factor obtained from Fig. 6-2 =(1+K1•K2•K3)2 Kzt @ h = 1.00 Topography = None K1,K2,K3 = Multipliers from Fig. 6-2 to obtain Kzt v Lh = 100.00 ft H = 100.00 ft H/Lh = 0.50 ' K1 = 0.00 X = 100.00 ft X/Lh = 0.50 K2 = 0.00 K3 @ h = 1.00 Gust Effect Factor, Gf. Obtained by Rational Analysis The gust effect factor Gf for main wind -force resisting systems of flexible buildings and other structures shall be calculated by rational analysis, using dynamic properties of the system Values Obtained from Table C6-6 Zmin = 15.00 ft e = 0.200 1 = 500.0 ft Page 2 SRANDEL -Project : ST. PETER LUTHERAN CHURCH Subject : WIND LOADS Location : FT. PIERCE, FL. J External Pressure Coefficient, Cp, Figure 63. (Cont.) The pressure force coefficient is given in Figure 6-3 Wmil Prceei ira Rnaffirtiante Cn Surface UB CD Use With Windward All Values 0.8 qz Leeward 1.00 -0.5 qh Side walls All Values -0.7 ah Dnnf Drams. Cnaffiniante r]n fnr sea with nh Windward Leeward Angle Angle WindLDirecfion h/L de . C (dea.) C N1.00 23.00 -0.58 23.00 -0.60 to 0.00 An Normal to Ridge Horizontal distance from edge (Ang. < 10) 1.00 0 to H/2 H/2 to H H to 2H > 2H and -1.27 -0.70 -0.70 -0.70 Parallel to Ridge for all Angles Design Wind Pressure. p. (psf). TABLE 6-1 Design wind pressures and forces are detennined per equations given in table 6-1 Surface CP qh (Psf) G P (Psf) Leeward wall -0.60 52.02 0.84 -21.88 Side wall -0.70 52.02 0.84 -30.63 Windward NTR -0.58 52.02 0.84 -25.38 Windward NTR 0.00 52.02 0.84 0.00 Leeward NTR -0.60 52.02 0.84 -26.26 Parallel PTR(1) -1.27 52.02 0.84 -55.42 Parallel PTR(2) -0.70 52.02 0.84 -30.63 Parallel PTR(3) -0.70 52.02 0.84 -30.63 Parallel PTR 4 -0.70 1 52.02 0.84 -30.63 File :98130 Date :9/21/99 Eng. : WTP Page 4 •BRANDEL Project : ST. PETER LUTHERAN CHURCH Subject : WIND LOADS Location : FT. PIERCE, FL. Design Wind Forces - Design wind forces are calculated as follows Heights feet Area s r k p s Force Ibs Shear Ibs Moment Ib-ft 30.01 - 39.00 1 35.01 35 35 157 25.01 - 30.00 1 33.13 33 68 415 20.01 - 25.00 1 31.88 32 100 835 15.01 -20.00 1 30.42 30 130 1,411 0.00 - 15.00 1 28.63 29 159 3,584 Total Area Base Shear Base Moment 5 (sq. ft.) 159 (Ibs) 3,584 (lb-ft) File :98130 Date :9/21/99 Eng. : WTP Page 6 Component Performance Method for Commercial Buildings Form 40OB-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs. FLA/COM-97 Version 2.2 PROJECT NAME_ST. PETERS LUTHERN CHURCH_ PERMITTING OFFICE: ADDRESS: PIERCE _Fort Pierce _FT. CLIMATE ZONE: _6 OWNER: ST. PETERS LUTHERN CHURCH_ PERMIT NO: _99-0000 AGENT: JURISDICTION NO:_661100 BUILDING TYPE: Assembly CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: Building _Finished CONDITIONED FLOOR AREA: _11900 NUMBER OF ZONES: 1 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 17 COMPLIANCE CALCULATION: METHOD B DESIGN CRITERIA RESULT ------ - ----------------- ------ ENVELOPE PERFORMANCE 26.97 -------- 66.22 PASSES OTHER ENVELOPE REQUIREMENTS PASSES LIGHTING INTERIOR LIGHTING 15000.00 23800.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. EER 9.00 8.50 PASSES Inv 7.50 7.50 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Unconditioned Space 6.00 4.20 PASSES REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT ' PIPING INSULATION REQUIREMENTS ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifica- specifications covered by this calcu- tions covered by this.calculation lation are in compliance with the indicates compliance with the Florida Energy Efficiency Code. Florida Energy Efficiency Code. PREPARED BY: Before construction is completed, DATE: this building will be inspected for compliance in accordance with I hereby certify that this building is Section 553.908, Florida Statutes. in compliance with the Florida Energy BUILDING OFFICIAL: Efficiency Code. DATE: OWNER/AGENT: DATE: I hereby certify(*) that the system desi is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER / REGISTRATION/STATE ARCHITECT MECHANICAL: PLUMBING SUITE 114 ` ELECTRICAL ^++ LIGHTING 41`vJ (*) Signature is required where Florida AaW requires design to be performed by registered design professionals. Typed es and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE y CHECK 401.------GLAZING--ZONE 1------------------------------------------------ v- Elevation Type U SC VLT Shading --------------- ---- ---- ---- -------------- Area(Sgft) ---------- --------- North Commercial 1.31 .01 0 None 168 South' Commercial 1.31 .01 0 None 72 East Commercial 1.31 .01 0 None 80 West Commercial 1.31 .01 0 None 96 Total Glass Area in Zone 1 = 416 Total Glass Area = 416 402.------WALLS--ZONE 1------------------------------------------------ --- Elevation Type U Insul R Gross(Sgft) ----------------------------------------- ----- ------- North 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4 ----------- 1190 South 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4 1190 East 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4 1000 West 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4 1000 Total Wall Area in Zone 1 = 4380 - Total Gross Wall Area = 4380 403.------DOORS--ZONE 1------------------------------------------------ --- Elevation Type U `-------------------------------------------------- ----- Area(Sgft) ---------- North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 42 - Total Door Area in Zone 1 = 42 Total Door Area = 42 404------- ROOFS --ZONE 1------------------------------------ =----------- --- Type Color U Insul R Area(Sgft) ------------------------------------ ------ ------------ Mtl Bldg Roof/R-19 Batt Medium .051 19 ---------- 11900 Total Roof Area in Zone 1 = 11900 Total Roof Area = 11900 4aS------- FLOORS -ZONE 1------------------------------------------------ --- Type Insul R ------- Area(Sgft) ---------- ------------------------------------------------ Slab on Grade/Uninsulated 0 11900 Total Floor Area in Zone 1 = 11900 Total Floor Area = 11900 406------- INFILTRATION -------------------------------------------------- --- CHECK Infiltration Criteria in 406.1.ABCD have been met. I MECHANICAL SYSTEMS CHECK --------------------------------------------------------- -- HVAC load sizing has been performed. (407.1.ABCD) 407------- COOLING SYSTEMS----------------------------------------------- --- Type No Efficiency IPLV Tons ---------------------------- ------------- -------------------- 1. Air Cooled ( >= 65,000 Btu/h 4 9.0 0 16.67 408------- HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr -------------------------------- --------------------------- 1. Electric Resistance 4 1 62840 409------- VENTILATION --------------------------------------------------- --- I CHECK Ventilation Criteria in 409.1.ABCD have been met. 410.- ---AIR DISTRIBUTION SYSTEM---------------------------------------- --- CHECK --------------------------------------------------------- --- --- Duct sizing and design have been performed. (410.1.ABCD) AHU Type Duct Location R-value ---------------------------------------------------------------- 1. Packaged Constant Volume Unconditioned Space 6 CHECK - -------------------------------------------------------------- -- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- --- Basic prescriptive requirements in 411.1.ABCD have been met. - PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1--------------------------------------- --- -Type R-value/in Diameter Thickness 412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons ELECTRICAL.SYSTEMS CHECK 413------ ELECTRICAL POWER DISTRIBUTION---------------------------- ----- --- Metering criteria in 413.1.ABCD have been met. 414.-----MOTORS --------------------------------------------------- ----- --- Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Classroom/ 1 On/Off 34 15000 11900 Total Watts for Zone 1 = 15000 Total Area for Zone 1 = 11900 Total Watts = 15000 Total Area = 11900 CHECK Lighting criteria in 415.1.ABCD have been met. ------------------------------------------------------------------ ----- --- 16. Operation/maintenance manual will be provided to owner.(102.1) ---------------------------------------------------------------------------- PROJECT TITLE ST. PETERS LUTHERN CHURCH AUILDING TYPE Assembly BUILDING LOCATION Fort Pierce BUILDING AREA(ft2): 11900 BUILDING ENVELOPE COMPONENT PERFORMANCE WALL ORIENTATION WEIGHTED AVER. N NE E SE S SW W NW DESIGN CRITERIA WALL 1190 1000 1190 1000 0.09 0.312 GL - 168 80 72 96 WWR WWR SC 0.010 0.010 0.010 0.010 0.01 0.500 PE 0.00 0.00 0.00 0.00 0.00 0.00 VLT 0.00 0.00 0.00 0.00 0.00 N/A Uof 1.310 1.310 1.310 1.310 1.31 1.150 W Uo 0.15 0.15 0.15 0.15 0.15 0.371 HC 21.00 21.00 21.00 21.00 21.00 1 IP 3 3 3 3 3 N/A L O A D S TOT HEAT 0.873 0.513 0.525 0.548 2.459< 4.012 COOL 6.333 5.768 7.596 4.819 24.516< 62.205 SUM 7.205 6.282 8.121 5.367 26.975< 66.216 ******** PASSES ******* OTHER ENVELOPE REQUIREMENTS MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN CRITERIA Percentage of Roof Area in Skylights 0.000 = 0.0000 MAXIMUM ALLOWABLE Uo: Roof 0.051 < 0.0868 n ******** PASSES ******* PROJECT TITLE ST. PETERS LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 11900 LIGHTING SYSTEM PERFORMANCE BUILDING DESIGN : Interior Lighting Power 15000 W 1.26 W/Gross ft2 Exterior Lighting Power 0 W INTERIOR LIGHTING CRITERIA: Space No. Type Area Clg Ht Spaces AF UPD PB LPB Total LPB 3 11900.0 10.0 1 1.00 2.00 2.00 23800 23800 Unit Power Density 2.00 W/Gross ft2 Interior Lighting Power Allowance 23800 W ******** PASSES ******** EXTERIOR LIGHTING CRITERIA: AREA AREA AREA OR ALLOWANCE "CODE DESCRIPTION LENGTH WATTS Exterior Lighting Power Allowance 0.00 W **** Not Applicable **** LIGHTING SYSTEM CONTROL REQUIREMENTS: TOTAL EQUIVALENT SPACE NO. CONTROLS CONTROL POINTS NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA 3 Classroom/ 11900.0 1 On/Off 34 0 34 > 10 ******** PASSES ******** PROJECT TITLE ST. PETERS LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 11900 HVAC SYSTEM REQUIREMENTS: Cooling System Type Measure #1 #2 Minim. #1 Minim. #2 System Eff.#1 System Eff.#2 Result for #1 Result for #2 Air Cooled. EER, IPLV 8.50 7.50 9.00 7.50 PASSES PASSES Heating System Measure Minimum Req. Efficiency Result Ele. Resis. Et 1.00 N/A ******** PASSES ******** AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS: Zone # Duct Location Minimum R-Value Design R-Value Result 1. Unconditioned Space 4.20 6.00 PASSES ******** PASSES ******** PROJECT TITLE ST. PETERS LUTHERN CHURCH BUILDING TYPE Assembly BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 11900 WATER HEATING SYSTEM REQUIREMENTS System Type Measure Minimum EF / Et Maximum SL Design EF / Et Design SL Result ****.Not Applicable **** PIPING INSULATION REQUIREMENTS: Pipe Insulation Thickness(in) System Type O.D.(in) Minimum Req. Design Result **** Not Applicable **** PAUL WELCH INC. Mechanical- Electrical • Civil • Engineering 1984 S.W. BIItmOre SL #114 Pert SL Lucie, FL 34984 Phone FAX (407) 785.9933 date. JUL T ROOM: '' pG�1 AREA: I I �I C •SF JUL sheet � Of � JOB. S- 115- LtATReP-A'O ZONE: N WALL............... Ir�o SF x 3,G.$ S WALL ............... l l al0 SF x tl'3(o L WALL ............... ICOO SF x AA_'I4 0 WALL ............... )000 SF x (,.S(Q lJ GLASS .............. IC'-°o sF x 44 5 GLASS .............. qZ SF x 441 C GLASS .............. 600 Sp x Cl l GLASS............... qle SF x �( ROOF l l q 00 SF x Q. 2 LIGHTS ................. Z3Sco W x 3.41 2la Soo PEOPLE.....,............ X. INPIL (62-89).......... 2DO agm x. S4 Sub Tata•1 = St duct 108ses. _ TOTAL = _ GS4o '13I2. 3S2 0 12a0 43 7 S le % 1n0 -0d l ISO Ib5a00 �Z2(D $Oa- 4a 6 � z 245 3G l S? (A 0 LI ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 2M VIRGINIA AVENUE FT. PIERCE. FL 34 M2.W52 561462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE y�• Th. CertlSCaBan Y b ha aorrtplalad a Pit tlMlpa ItfCllibat M aI►plllaar. Thin CarNintian moat bo a i_fofbuiElnppaflNtylNplyyf0yNC01MhII�pflapgwry�T�� ubmilteCwithalleppliulionz a bultd ft penaft ww INIy Ilonplda m arlrctun. This Y1 Taldan6M sdditn. any aocessm structure requ ring wads. t aI•olllar aNaIBaI chat rtot appy b InIWw ranovaflona rovi"d that no structural IhaBuiWirgInspadlonORIatl sS53br �&shWWk"VPegs• Forfm%waaaisw".pleaseconleu i _ lla1 rt i I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCEDBY ST. LUCIE COUNTY. SO CERTIFY THAT STRUCTURAL ELEMENTS BY CURRENT CODE PROVISIONS. 1 AL DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE AL THE WIND LOADS AND FORCES SPECIFIED T23;d;i71 7T a7T1 _ ,n ��l N . FARM.LvEN Dom_ OPEN aUIIDING__ WIND SPEED USED IN BUILDING DESIGN: Ito MPH S. WINDEIIPOSURECIASSIFICITION roves TOGO*$= TAa{aa WaWAMCM CVaV4WW tNF atl: S. AVEMOt41A1 W VELOCITY PRESSURE O $WfTIR M FAC16 OF W$tUCTUAL 7. PEAK VAND VELOCITY PRESSURE ON DITERIOR FACES OF STRUCTURE a. IMPORTANCEMISEFACTOR (OaTMIIae611KUMOM a. LOADS: FLOOR / OG— PSF RODFNEAD: 3Z PSF 16. WERE SPIAR WALLS CONSIDERED POR STRUCTURE ttsedtael YES e esplainsu") C 4 PSF PSF ROOFAJVE: r PSF NO.._ N No. %ty? (Mach 11. IS A CONTINUOUS LOAD PATH PROVIOEDpcmcNel YEs-1e, No __ VNO.uw(attach sxplawtw) 1INO L ARE COMPONENT AND CtADDDETAt3 PROVWED tc ea am YES ✓ NO _ of No. why? (Sabah .apwuuea) -c fa. SaMMOLlaa SON. OwwNO rF498WJ O: esm Pap AS VVNESSEO BY MY SEAL. I HEREBN CERTIFY THAT THE INFORMATION INCLUDED WI1161 THIS%%GkTIFICATtON IS TRUE AND CORRECT. TO THE BEST OF MY KNOWLEDGE AND BELIEF. - W -!i)_ T A1TF�5a&2 CERTIFICATION NO: _ - - -MIZ -- `NAME:.. - ,q OESION FIRM: 91 "%��D-.Ti1rL��i7 DATE:'r]C'RE:4 P r. /t}�• `Cx5„iw.'orw ra owm .1 t 2400 Rhode Island Avu. St. Lucie County Fire District Tcicphone (561) 462.2312 n 10 Ft. Pierce, Florida 34950 Fee Schedule Fax No. (561) 462-2323 A Occupancy�T.Trn[ / Urice[r<1 riu.oi Date:_ Address: �TgmelNS Rcl Contractor: M�1.✓• TggL VDEZ[- Type of Perm* ( ew ( ) Addition ( ) Renovation/alteration () Tenant Improvement () Shell Only ( ) Sprinkler System ( ) Standpipe ( ) # of risers ( ) System type ( ) Fire Pump ( ) GPM ( ) Hood/duct ( ) Fixed Fire Protection ( ) Spray Booth ( ) Fire Alarm () Voice Alarm ( ) Detection System ( ) Command Station () Communications ) Aboveground tanks ( ) Underground tank/s ( ) # of tanks ( ) Containment ) Dispenser/s ( ) # of dispensers ( ) Fuel piping ) LP Storage ( ) # of tanks ( ) Removal ) Tank removal ( ) # of tanks ( ) Abandonment in place ( ) Tent installations ( ) Profit () Non-profit ( ) Firework display ( ) Public ( ) Private Dollar Value .z O D noo Type of Occupancy ( ) Hotel/motel ( ) Apartme;nticondo ( ) Room/board () ALF ( ) # of units/rooms (-Other L car?tq/ y Automatic Sprinkler System: Base Fee $ plus $1.00 per head Standpipe System: Number of risers @ $25.00 per riser Fire Pump: Gallons per minute @ $0.25 per gallon Foam System: Base Fee $ plus $ 1.00 per head Fixed Fire Protection System: Total weight @ $1.00 per pound or $50.00 minimum Fire Alarm System: Base Fee $ plus $1.00 per device Detection System: Base Fee $ plus $1.00 per device Voice Evacuation System: Number of floors @ $10.00 per floor or maximum of $150.00 Fire Department Communication System: Base Fee $50.00 in addition to the Alarm System ( ) Fire Command Station: Base Fee $50.00 in addition to the Alarm System ( ) Flammable/Combustible Storage Tanks: $60.00 for one tank plus $25.00 each additional tank ( ) Containment: Tank Removal: Dispenser/s: @ $30.00 per dispenser Tents: Firework Display: Permit Renewal: o� Total Fee Due: $ 1 1 3 6- Received Fee includes initial inspection By ) # of tanks ( ) Dormitories ( ) High Rise BRANDEL Project Subject •L' ocation ST. PETER LUTHERAN CHURCH File : 98130 WIND LOADS Date : 9/21/99 FT. PIERCE, FL. Eng. : WTP Design Wind Pressure. D. TABLE 6-1 Design wind pressures and forces are determined per equations given in table 6-1 Design wind loading Structure type Equation Main wind -force Flexible p : q•Gf•Cp resisting system Buildings qz : For windward wall @ Height z qh : For Leeward wall @ mean roof ht. Gf : Obtained by rational analysis Cp : given in Figure 6-3 Velocity Pressure Calculations, qz and gh Velocity pressure qz and qh are calculated in accordance with section 6.5 qz = Velocity pressure @ height (z) qz = Constant • Kz • Kzt • V' •1 qz = See wind pressure calculation table qh = Velocity pressure @ height (h) qh = Constant • Kh • Kzt • V' •1 Where : Constant = Numerical constant _ '/2 • [ ( Air density lb/ cu It / ( 32.2 f /s2 )] _ [( mi/h )( 5280 ft/mi) (1 hr/3600 s )]' = 0.00256 Mean Sea Level = 0.00 ft Air Density @ MSL = 0.0765 Ib/cu It Category = I Importance Factor = 0.87 Exposure Category = C Alpha = 9.50 Zg = 900.00 ft Basic Wind Speed = 120.00 mph Structure Height = 39.00 ft Width = 76.00 ft Depth = 182.00 ft Natural Frequency = 0.2000 Hz Damping Ratio = 1.0000% 1 (Open terrain) (Eq. 6-1) (C2) (Table C6-1) (Table 1-1) (Table 6-2) (Table C6-2) (Table C6-2) (Figure 6-1) ©: .�. V BRANDEL Project : ST. PETER LUTHERAN CHURCH File : 98130 13ubject : WIND LOADS Date : 9/21/99 .Location : FT. PIERCE, FL. Eng. : WTP Velocity Pressure Calculations. az (Cont.) Where: Kz = Velocity pressure coefficient @ height z (C3a) = 2.01 ( Z/Zg) • A(2/Alpha) for 15 ft <= Z <= Zg (C3b) = 2.01 (15/Zg) - A (2/Alpha) for Z <= 15 ft = See wind pressure calculation table Kh @ h = Velocity pressure coefficient @ height h = 1.04 Kzt = Topographic factor obtained from Fig. 6-2 =(1+K1•K2•K3)2 Kzt @ h = 1.00 Topography = None K1,K2,K3 = Multipliers from Fig. 6-2 to obtain Kzt Lh = 100.00 ft H = 100.00 ft H/Lh = 0.50 K1 = 0.00 X = 100.00 It X/Lh = 0.50 K2 = 0.00 K3 @ h = 1.00 Gust Effect Factor, Gf. Obtained by Rational Analysis The gust effect factor Gf for main wind -force resisting systems of flexible buildings and other structures shall be calculated by rational analysis, using dynamic properties of the system Values Obtained from Table C6-6 Zmin = 15.00 ft e = 0.200 l = 500.0 ft Page 2 BRANDEL Project : ST. PETER LUTHERAN CHURCH Subject : WIND LOADS Location : FT. PIERCE, FL. Gust Effect Factor, Gf. Obtained by Rational Analysis (Cont.) Values Obtained from Table C6-6 c = 0.200 b (-) = 0.650 Alpha (-) = 0.154 b (A) = 1.000 Alpha (A) = 0.105 Calculated Values File :98130 Date : 9/21/99 Eng. : WTP Analysis = Category II : Rigid Structure -Complete Analysis n 1 ( Frequency) = 0.000 Hz Vref (A) = 176.0 ft/s z (-) = 23.40ft Iz = c . (33/z) A (1/6) = 0.212 Lz = 1 - (z/33) Ae = 466.8 ft Q' = 1/ (1 + 0.63 - [(b+h)/Lz]A0.63 ) = 0.793 Vz (-) = b(-) • (z/33]A(a1pha(--)) • Vref = 108.51 fus N1 = n1 • Lz/Vz = 0.000 Rn = 7.465 • N1 / (1 + 10.302 • N1)A (5/3) = 0.000 RI = (1/n-1/2-n2(1-eA(-2•n))]forn>0 _ (1 ]forn=0 nh = 4.6•nl.h / Vz = 0.000 nb=4.6•nl.b/Vz) = 0.000 nd = 4.6.nl A / Vz) = 0.000 Rh = RI (n = nh) = 1.000 Rb = RI(n = nb) = 1.000 Rd = RI(n = nd) = 1.000 R' _ (1/8)•Rn-Rh-Rb(0.53+0.47•Rd) = 0.000 g ( peak factor) = 3.500 Gust Factor ( G ) _ (1+2•g-lz•Sgr(Q2+R'))/(1+7-Iz) G = 0.841 (C6-6) (C6-6) (C6-7) (C6-7) Page 3 BRANDEL Project : ST. PETER LUTHERAN CHURCH Subject : WIND LOADS "Location : FT. PIERCE, FL. File :98130 Date :9/21/99 Eng. : WTP External Pressure Coefficient, Cm Figure 6-3. (Cont.) The pressure force coefficient is given in Figure 6-3 Wall Pressure Coefficients_ Cn Surface UB CP Use With Windward All Values 0.8 qz Leeward 1.00 -0.5 qh Side walls All Values -0.7 gh Roof Pressure Coefficients. Co. for use with ah Windward Leeward Angle Angle Wind Direction h/L de C de C Normal 1.00 23.00 -0.58 23.00 -0.60 to Ridge 0.00 (An . >= 10 Normal to Ridge Horizontal distance from edge (Ang. < 10) 1.00 0 to H/2 H/2 to H H to 2H > 2H and -1.27 -0.70 -0.70 -0.70 Parallel to Ridge for all Angles Design Wind Pressure. P. (osf). TABLE 6-1 Design wind pressures and forces are determined per equations given in table 6-1 Surface Cp qh G P (psf) (psf) Leeward wall -0.50 33.29 0.84 -14.00 Side wall -0.70 33.29 0.84 -19.60 Windward NTR -0.58 33.29 0.84 -16.24 Windward NTR 0.00 33.29 0.84 0.00 Leeward NTR -0.60 33.29 0.84 -16.80 Parallel PTR(1) -1.27 33.29 0.84 -35.47 Parallel PTR(2) -0.70 33.29 0.84 -19.60 Parallel PTR(3) -0.70 33.29 0.84 -19.60 Parallel PTR(4) -0.70 33.29 0.84 -19.60 Page 4 BRANDEL Project ST. PETER LUTHERAN CHURCH Subject WIND LOADS :Location FT. PIERCE, FL. File :98130 Date :9/21/99 Eng. : WTP Design Windward Wall Wind Pressures. p, TABLE 6-1 Design wind pressures and forces are determined per equations given in table 6-1 Heights feet Kz K3 Kzt qz s Cp P s 30.01 - 39.00 1.04 1.00 1.00 33.29 0.80 22.40 25.01 - 30.00 0.98 1.00 1.00 31.50 0.80 21.20 20.01 - 25.00 0.95 1.00 1.00 30.32 0.80 20.40 15.01 - 20.00 0.90 1.00 1.00 28.92 0.80 19.47 0.00 - 15.00 0.85 1.00 1.00 27.23 0.80 18.32 Page 5 BRANDEL Project : ST. PETER LUTHERAN CHURCH Subject : WIND LOADS ;Location : FT. PIERCE, FL. Design Wind Forces Design wind forces are calculated as follows Heights feet Area s r R p s Force Ibs Shear Ibs Moment Ib-ft 30.01 - 39.00 1 22.40 22 22 101 25.01 - 30.00 1 21.20 21 44 266 20.01 - 25.00 1 20.40 20 64 535 15.01 - 20.00 1 19.47 19 83 903 0.00 - 15.00 1 18.32 18 102 2,294 Total Area Base Shear Base Moment 5 (sq. ft.) 102 (Ibs) 2,294 (lb-ft) File :98130 Date :9/21/99 Eng. : WTP Page 6 NEW SERVICE ST. PETERS CHURCH POLE FOR PRIMARY RISER NOV 12 1999 St. Lucia County Public Works 1363 Ad&A= RCLLLPYRNI' (RfYR'C R1Y' ) w.D./ 504 w.o.p rUIMAM ((((41- rZW� w.o./ POD DVSTA1l (4■ • }■ W.o./ ROWFB e • FORMAT (nOr ■ • WDLFlID (90r ■ . DnL um TRANSAQSSlON (e} F DLSTRLDUT/ox - CA: COLOR sRLONDARr (so) - Ult DA_S TRANSAfLSsroN - — DLST%ROTLON - CRl. COLOR SALONDARY - AfA7CRLTNRS - E ALL OTNRRS - # q NEW SERVICE JENKINS RD (ST. PETERS) 11/10/ ev 0 Initial Release DATE REVISION /: DESCPoPnON: FT. PIERCE UTILITIES AUTHORITY 206 S. eth STREET ELECTRIC OPERATIONS FT. PIERCE. FLORIDA 34M-3191 ENERGY SERVICES CENTER ;CALE: 1 ^ = 100' JOB /: g DATE: 11 /1 G X SCANNED BY St. Lucie Couniv JPR BY: APPROVED: Ev` JPR 1ED: ✓PR > OF 1 6