Loading...
HomeMy WebLinkAboutTRUSS PAPPERWORK4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 0- FX: 772-409-1015 0 www.AlTruss.com LU SCANNED BY St. Lucie County TRUSS ENGINEERING BUILDER: RENAR PROJECT. MORNINGSIDE COUNTY: ST LUCIE LOT/BLK/MODEL: LORIo(o/ MODEL:CAYMAN 1560 / ELEV.B1/ GAR JOB#: 78346 MASTER#: WRMSCM1560BlL OPTIONS: 16X9 PORCH. NO VALLEYS. Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. J = TRUSSES A FLORIDACORPORAmON RE: Job WRMSCM156OBl L A-1 Roof Trusses 4451 St Lucie Blvd Sltb Information: Fort Pierce, FL 34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: Model: CAYMAN 1560 Address: Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20120 0.0 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 43 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No.. Seal # Truss Name Date 1 A0280547 A01 8/22/19 13 A0280559 A13 8/22/19 25 A0280571 CJ5 8/22/19 2 A0280548 A02 8/22/19 14 A0280560 A14G 8/22/19 26 A0280572 CJ5A 8/22119 3 A0280549 A03 8/22119 15 A0280561 1301G 8/22/19 27 A0280573 UK 8/22119 4 A0280550 A04 8/22119 16 A0280562 B02 8/22/19 28 A0280574 UK 8122119 5 A0280551 A05 8/22119 17 A0280563 B03 8/22/19 29 A0280575 CJ6 8/22119 6 A0280552 A06 8/22/19 18 A0280564 B04G 8/22/19 30 A0280576 GE01 8/22119 7 A0280553 A07 8/22/19 19 IA0280565 B05 8/22/19 31 IA0280577 I HJ7 8122119 8 A0280554 A08 8/22119 20 A0280566 B06 8/22/19 32 A0280578 HJ7A 8122119 9 A0280555 A09 8122/19 21 A0280567 CA 8/22/19 33 A0280579 HJ7L 8122119 10 A0280556 A10 8/22/19 22 A0280568 CJ3 8122/19 34 A0280580 J7 8122119 11 A0280557 All 8122/19 23 A0280569 CJ3B 8122119 35 A0280581 J7L 8122119 12 IA0280558 I Al2 8/22/19 24 A0280570 I CJ3L 8122/19 36 A0280582 HT 8/2219 The truss drawirg(s)referenced havebeenpreparedbyWhole House Er ineedrig,Inc.undermydirectsupovisimbasedwtheparametersprovidedbyA-1 RoofTrusses,Lid. NUM -The seal on these drawings indicate acceptance of professlonalengineering responsibWtysolelyforthetrus components shown. The sultabSdyand use of wmponentsforanypadicularbu8ding lathe responsibiritycfthebuilding desgner,perANSUPI.1 Seel The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to attunes as'Structural Engineering Documental provided bythe Building Designermdicating the nature and charecterofthe work The design aiteda therein have been transferred totheTruss Design Engineerby [AI RoofTmsses or specificlocation]. These TDDs (also referred to att'ories as'Stmctural Delegated Engineering Documental are specialtystiuctural component designs and maybe partof the pioject's defemA orphaned submtiaLs As aims Desigri Engineer(Le, Specialty Engineer),theseal here and on tthe TDD mpiFsents an acoeptanbeof professional engineering respons3StyforthedesgnotihesingieTumdepic"d ontreTDD only. The Building Designer's responsibleforandshallcootdinateand mtswttieTljlDsfor- cornpabbrdywth the'nwrittenengineering mquirwrient6. Please rcvrew all TDDs and all related notes. l�trl Page 1 of 2 �G 7361— .�`�11-1 g I,p i No;62809 STATE OF 16'.43.42:4Y ' 117vSlrlK#Al `����• Tmss Design Engineers License renewal dateyr/11I i I i 1111\\ forthe state of Florida is Febmwy28,2021 SERIAL# 5f054982f500e8feb 19a64ef 4451 St. Lucie Blvd. Fort Pierce, FL 34946 Job Truss Truss Type Oty Ply R0280547 WRMSCM1560B1L A01 Roof Special 1 1 Job Reference(optional) A-1 K= I MSSaa, rOR r1eT a, rL J va . uesign(Oraleuss.Com Hun: b.zlu s May la zu1b Punt n.Llu s May 16 zuld Ml lex Industnes, inc. ID:ld_OOXyyT61Bi TXoljwHHzefvK-2JdTv1OZMpJdPjC IX1 11-2 73-8-015-6-Q77-4-119-1- 24 1 30-10-12 38-0-0 Y-4-0 7-0-0 47-2 -8-1 1-1 7-1 1-9-5� 5.2-10 6{}12 7-1-4 7x10 MT20H8r 316 = 2x4 II 8.0012 5x67x10 MT20HS-- 2x4 II 7 8 22 21 18 17 "' 15 3.6 = 4.6 = 2x4 II 2x4 II 4x8 = 3.6 = 7.Sx4 11 Us LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl LJd TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(L-) 0.53 18 >854 360 TCDL 10.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -1.01 19-20 >452 240 BCLL 0.0 ' Rep Stress Incr YES WB 1.00 Horz(CT) 0.58 13 n/a We BCDL 7.0 Code FBC2017/rP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2'Except' T3: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 *Except' B2,B4: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except- W3: 2x4 SP No.2, W6: 2x4 SP M 30 BRACING- TOPCHORD Structural wood sheathing directly applied or 24-14 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 cc bracing. WEBS 1 Row at midpt 10-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erector, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 13 = 1490/0-7-10 (min. 0-1-12) Max Horz 2 =-138(LC 10) Max Uplift 2 = .377(LC 12) 13 = 430(LC 13) Max Grav 2 = 1490(LC 1) 13 = 1490(LC 1) r FORCES. (Ib) Max. Comp./Max: Ten. - All forces 250 (lb) or less except when shown. Tno runan 3-22=1339/845, 20-22=-1523/2709, WEBS 3-22=1339/845, 20-22=-152312709, 6-19=-1278/2608, 17-19=113412387, 10-17=1262/578,12-17=-619/549, 6-20=-335/499, 3-20=559/1368, 10-19=2209/4464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp S; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 377 lb uplift at joint 2 and 430 lb uplift at joint 13. 8) Graphical puriin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. LOAD CASE(S) Standard 13:41:UJZU19 Page UFg8FdMZX4ZVgy117 Dead Load Deff. =1r2 in PLATES GRIP MT20 244/190 MT20HS 187/143 Weighl:224lb FT=10% 1 Job Truss Truss Type Oty Ply a A0280548 WRMSCM1560B1L A02 Hip i 1 Job Reference(ootionalt A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek 6.00 12 5x6 = 2X4 11 6x8 = ' A II Inc. Thu Aire 22 13:41:04 2019 20 19 16 15 — 13 316 = 4x6 = 2x4 11 2x4 II 5x8 = 3z6 = 3x6 1.5z4 II 11-1122 0 I 1-16 ) 220 29-4 1 38-M 4-7 �4 9-6 b-41 78$2 Dead Load Deff. = 7/16 in Plate Offsets (X,Y)— f6:0-3-0,0-2-01.(8:0-6-0,0-2-81.(15:0-2-8,0-2-01.(17:0-2-4,0-3-81 f18:0-3-8,0-2-121 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.99 Vert(L-) -0.41 17-18 >999 360' MT20 - 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.89 Vert(CT) -0.81 17-18 >562 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.80 Horz(CT) 0.48 11 n/a n/a BCDL 7.0 Code FBC2017/7P12014 Matrix -MS Weight: 221 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 "Except` B2,B4: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W3,W7,W6:2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 4-7-15 oc bracing. WEBS 1 Row at midpt 8-15, 10-15 MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min.0-1-12) 11 = 1490/0-7-10 (min.0-1-12) Max Horz 2 = -139(LC 10) Max Uplift 2 = -378(LC 12) 11 = -378(LC 13) Max Grav 2 = 1490(LC 1) 11 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2664/1664, 3-4=-4164/2474, 4-5=-4062/2489, 5-6=-4171/2629, 6-7=4081/2370, 7$=4045/2360, 8-9=-1836/1336, 9-10=1948/1312, 10-11=2612/1629 BOT CHORD 2-20=-1301/2307, 5-18=-224/270, 17-18=1455/3218, 14-15=1266/2250, 13-14=1266/2250, 11-13=-1266/2250 WEBS 3-20=-13361841, 18-20=-1516/2704, 6-18=-746/926, 6-17=-561/1302, 15-1 7=1 309/2960, 8-15=-2068/846, WEBS 3-20=-1336/841, 18-20=-1516/2704, 6-18=-746/926, 6-17=-561/1302, 15-1 7=1 30912960, 8-15=-2068/846, 10-1 5=718/630,10-13=0/300, 3-18=-564/1371, 8-17=-1604/3565 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf, h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 378 lb uplift at joint 2 and 378 lb uplift at joint 11. LOAD CASE(S) Standard Job Truss Truss Type OtY Ply AWT10549 WRMSCM1560BiL A03 Hip 1 1 Job Reference o 6onal A-1 Roof Trusses, Fort Pierce, FL 34946, designaaltruss.com Run: 8.210 s May 182018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 2213:41:052019 Pagel Old _OOXyyT61Bi_TXoljwHHzefvK- ilEKRRquOZLelaCRPmH5y7dGlyuc9YfOsm4YY117C 20- 1-4-0 11-11-2 1J$9 19-1 2a/042 38-0e '1 4]-2 54F14 8612 1.2.10 6.00 12 5x10 = 5x6 = 20 19 t5 14 — 12 = 3x6 = 46 = 2x4 11 3x4 II 3.6 — 3x6 6x6 = Dead Load Dail. = 5/16 in 20d 0 ]-0-0 11-11-2 1]43-0 19-14 2a-10-12 3880 T7-2 SA14 �I-S6 8St2 9-1A 1.2-10 Plate Offsets (X,Y)-- r4:0-3-0,Edgel, 17:0-3-0,0-1-81, rl2:0-3-0,0-2-01, r16:0-2-8,OJ-01, f18:0-5-4Eclml LOADING(pst) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP ' -- TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) -0.33 15 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -0.60 17-18 >765 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.97 Horz(CT) 0.40 10 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MS Weight:221Ib FT=10% LUMBER - TOP CHORD 2x4 SP 240OF 2.0E `Except* T3: 2x4 SP No.2 BOT CHORD 2x4 SP No.2'Except` B2: 2x4 SP No.3 WEBS 2x4 SP No.3'ExcepY W3: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purins. BOT CHORD Rigid ceiling directly applied or 4-2-6 oc bracing. Except. 10-0-0 oc bracing: 14-16 WEBS 1 Row at midpt 12-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149710-7-10 (min. 0-1-12) 10 = 1498/0-7-10 (min. 0-1-12) Max Hom 2 = -156(LC 10) Max Uplift 2 = -387(LC 12) 10 = -387(LC 13) Max Grav 2 = 1497(LC 1) 10 = 1498(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2674/1670, 3-4=4231/2526, 4-5=-4123/2541, 5-6=3329/1912, 6-7=-3331/1979, 7-8=3683/2093, &9=3815/2464,_930�61ZLt630 BOTCHORD 2-20=-1306/2317,5-18=-206/367, 17-18=-1998/3877,16-17=-1221/2990, 10-12=1266/2256, 7-16=642/1337 WEBS 3-20=-13541854,18-20=-1524/2714, WEBS 3-20=-1354/854,18-20=-1524/2714, 5-17=-891/794, 6-17=363/566, 6-16=-341/795, 9-16=-103/1041, 9-12=-1088/759,12-16=1453/2556, 3-18=-613/1427 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 387 lb uplift at joint 2 and 387 lb uplift at joint 10. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply � A0280550 WRMSCM1560B1I- A04 ROOF SPECIAL 3 1 Job Reference (optional) ,A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu 6.00 12 516 = 5 5x6 G 5x6 1 4 6 1.5x4 0 W 3 a 3 7 12 1 6x8= 1 B 14 13 111 0 1 v Q12 3x8 MT20HS� 3x8 MT20 79 [qo 3x4 3.0012 3.4- 1.5*04 II 1.5x4 II 1.5x4 II Sxe c 4x8 0 1.5x4 II 5x8 30-9-15 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Ve I(CL) 0.55 12-14 >826 360 TCDL 10.0 Lumber DOL 1.25 SC 0.84 Vert(CT) -1.04 12-14 >437 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.91 Horz(CT) 0.65 8 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matnx-MSH LUMBER - TOP CHORD 2x4 SP N0.2'Except' T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* W6,W5: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purins. BOTCHORD Rigid ceiling directly applied or 4-6-12 oc bracing. Except: 4-7-0 oc bracing: 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1490/0-7-10 (min. 0-1-11) 8 = 149010-7-10 (min. 0-1-11) Max Horz 2 = 166(LC 11) Max Uplift 2 = -399(LC 12) 8 = -399(LC 13) Max Grav 2 = 1490(LC 1) 8 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4697/2907, 3-0=-4307/2635, 4-5=-3134/1852, 5-6=-3134/1852, 6-7=-4321 /2660, 7-8=4676/2926 BOT CHORD 2-14=2490/4232, 13-14=-190613619, 12-13=1902/3644, 11-12=1905/3647, 10-11=1916/3622, 8-10=-2507/4245 WEBS 5-12=-133812394, 6-12=-864/801, WEBS 5-12=1338/2394, 6-12=-864/801, 6-10=285/576, 7-10=-352/445, 4-12=-8611796, 4-14=-280/568, 3-14=356/464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 399 lb uplift at joint 2 and 399 lb uplift at joint 8. LOAD CASE(S) Standard PLATES MT20 MT20HS Dead Load Defl. = 9/16 in GRIP 2441190 1871143 Weight:2001b FT=10% Job Toss Truss Type Oty Ply A02SO551 WRMSCM1560BIL A05 SCISSORS 4 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:06 2019 Page 1 ID:Id_OOXyyT61Bi_TXoliwHHzefvK-SUJcYnSSfkhCGA9076HWe9gpOiKTLdhpFW W4vl7B -0-7 I 2522-11 I 2 3800 6-2 6712-9 3 7 21 2-06614 64 4I- 6.00 F12 5.6 = 5x8 G 5x8 6 1.5x4 c w 3 1.5x 24 3 7 i w 6x8 = B 14 13 11 10 1 7 2 3x8 MT20HS� rb 8 3.00 12 3x8 MT20HS-- y 3x4 4.8 94i14 19-0-0 1 3-2 38-0-0 9-8-14 9-3-2 932 94L74 4x8 Dead Load Defl. = 9/16 in Plate Offsets (X,Y)— 12:0-1-14,Edge1. t4:0-3-12,0-3-01, 16:0-3-12,0-3-01, f8:0-1-14,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Waft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.58 12-14 >789 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -1.08 12-14 >420 240 MT20HS 1871143 BCLL 0.0 Rep Stress lncr YES WB 0.92 Horz(CT) 0.69 8 n/a n/a BCDL 7.0 .Code FBC2017/TPI2014 Matrix -MS Weight: 180lb FT = 10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purins. BOT CHORD Rigid ceiling directly applied or4-5-14 oc bracing. MiTek recommends that Stabilizers and required crass bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min.0-1-11) 8 = 1490/0-7-10 (min. 0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -399(LC 12) 8 = -399(LC 13) Max Gmv 2 = 1490(LC 1) 8 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD WEBS 5-12=-1350/2406, 6-12=-867/806, 6-10=-239/565,7-10=-386/506, 4-12=-867/807,4-14=-241/565, 3-14=-386/508 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 399 lb uplift at joint 2 and 399 lb uplift at joint 8. 2-3=-4730/2950,3-4=-4291/2612, 4-5=-3137/1854, 5-6=-3137/1854, 6-7=-4291/2626, 7-8=-4730/2972 LOAD CASE(S) BOT CHORD Standard 2-14=-2537/4265,13-14=-1916/3626, 12-13=1912/3651. 11-12=1917/3651. 10-11 =1 92113626, 8-10=-2560/4265 WEBS 5-12=-1350/2406, 6-12=-8671806, 6-10=-239/565, 7-10=386/506, 4-12=-867/807,4-14=241/565, 3-14=-3861508 Job Truss Truss Type Oty Ply '4 A0280552 WRMSCM1560BIL A06 ROOF SPECIAL 1 1 Job Reference o tional A-1 Hoot I msses, FOR vierce, rL J4a4o, aeslgn(dalauaa.com nun: o.nu s may io 4ula rnnc a, lu a may io eu 6.00 12 5x6 = 6 3x6 G T 5x6 4 5x6 C 5 7 4 W4 6 3x4 i 1.5x4 i 3 8 13 V42 6x8 = 8 m1 2 i6 3.6 = 6x6 = 15 2x4 II 12 11 3.00 72 3x8MT20HS,' 3.4 7-6 11-1n-19 . IA-r1A 28-1-9 38-M Inc. Thu Aug 22 13:41:U/ 2019 Page 1 13uNa$29poollBBN D_E5dE45lyUAFAeRy117A 5-4-0 Dead L.d Deft. = 7116 in N 1,- 0; 4x8 7-6-4 44-8 7-1-4 9-1-9 9-10-7 Plate Offsets (X Y) - 17:0-3-00-3-07 19:0-1-14 Edeel 114:0-5-8 0-4-81 LOADING(psf) SPACING- 2-M CSI. DEFL. in (too) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.49 11-13 >924 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.96 11-13 >474 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.89 Horz(CT) 0.57 9 n/a n/a BCDL 7.0 Code FBC2017JTPI2014 Matrix-MSH Weight. 193 lb FT=10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 *Except- B1,B3: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 244 oc puriins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 9 = 149010-7-10 (min.0-1-11) Max Horz 2 = 166(LC 11) Max Uplift 2 = -400(LC 12) 9 = 400(LC 13) Max Grav 2 = 1490(LC 1) 9 = 1490(LC 1) FORCES. (lb) .Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORO 2-3=-2649/1686, 3-4=4340/2667, 4-5=-3153/1816, 5-6=-305211841, 6-7=-3136/1856, 7-8=4315/2672, 8-9=-4678/2898 BOT CHORD 2-16=-1316/2291, 4-14=-233/447, 13-14=2135/3999, 12-13=-189713634, 11-12=190113609, 9-11=-2479/4215 WEBS 3-16=1451 /920, 4-13=-1175/1004, WEBS 3-16=1451/920, 4-13=-1175/1004, 6-13=-1286/2346,7-13=-8531776, 7-11=-315/579, 8-11=-337/439, 14-16=156612749, 3-14=720/1562 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Ecp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) 9 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 400 lb uplift at joint 2 and 400 lb uplift at joint 9. LOAD CASE(S) Standard Job Truss Truss Type Cry Ply A0280553 WRMSCM1560BIL A07 ROOF SPECIAL 1 1 Job Reference o fional A-1 Roof Trusses, Fort Pierce, FL 34946, design@altrumcom Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:08 2019 Page 1 ID:Id_OOXyyT6IBi_TXoljwHHzefvK-OHRMyTUiBL=VUlm7XJjal9_VzTpYY5igl, Aty1175 19-9-7 ,1-" 7-64 1t-10.12 18-2A 1 --�0� 2501 30-'r12 360-0 394g 141 4-0A 6313 6&ramg b2-10 SS11 7L4 1r-4� 6.00 12 �z8 Dead Load D.O. = 7A6 in 3x4 i 2 �G 3x6 5x6 4 5 4 W4 13 5x8 = 5x6 C 7 12 11 3.00 72 Us MT20HSr 3x4 1.Sx4 G 8 16 15 3x6 = 6.6 = 2x4 11 4x8; 7-6-4 11-10-12 19-0-0 28-1-9 38-0 0 4-0-8 7 1 9-1-9 510-7 Plate Offsets X Y :0-3-0,0-3-0 9:0-1-14 Ede 13:0-2-8 0-3-8 , 14:0-M 0-4-8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.49 11-13 >924 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.9611-13 >474 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.89 Horz(CT) 0.57 9 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix-MSH Weight: 193 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2X4 SP M 30'Except' B1,B3: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-4-4 oc puriins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min. 0-1-12) 9 = 1490/0-7-10 (min. 0-1-11) Max Horz 2 = 166(LC 11) Max Uplift 2 = -400(LC 12) 9 = -400(LC 13) Max Grav 2 = 1490(LC 1) 9 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-16=-1451/920,4-13=-1175/1004, 7-13=-853/776, 7-11=315/579, 8-11=-337/439, 14-16=-1566/2749, 3-14=-720/1562, 6-13=-128612346 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF, h=15ft; Cat. II;Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 400 lb uplift at joint 2 and 400 lb uplift at joint 9. TOP CHORD LOAD CASE(S) 2-3=-2649/1686, 3-4=-4340/2667, Standard 4-5=-3153/1816, 5-6=3052/1841, 6-7=-3136/1856, 7-8=-4315/2672, 8-9=-4678/2898 BOTCHORD 2-16=-1316/2291,4-14=-233/447, 13-14=-2135/3999, 12-13=1897/3634, 11-12=-1901/3609, 9-11=-2479/4215 WEBS 3-16=-1451/920, 4-13=-117511004, Job Truss Truss Type Qty Ply e. A0280554 WRMSCM1560BiL A08 ROOF SPECIAL 1 1 Job Reference optional) A-1 HOOT I russes, Yon Ylerce, rL 3494o, oesign(Na1mlSs.com Ruff: o.L 1U5 May to Lu 13:41:U8 2U19 Page 1 5x10 MT20H5- 6.00 12 Dead Load Deb. = 3/8 in 6 Us i 5x6 i 5x6 1 5 7 4 W4 3x4 6 1.5x4 i 3 8 13 W2 6x8= 8 12 5 4 2 1 3 E �8xa 71 3x8 MT20H3- 0 1 3.00 12 3x4 a - 16 15 3x6 = 6x6 = 2x4 11 3x8 7-6d I 10-12 19-0-0 28-1-9 _ 38-0-0 7-64 - 4�-8 7-1-4 9-1-9 9.10-7 Plate Offsets (X Y)— 17:0-3-0 0-3-01 19:0-0-10 Edgel 114:0-5-8 0-4-81 LOADING(psf) SPACING- 2-M CSI. DEFL. in (Joe) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) 0.46 11-13 >994 360 MT20 244/190 TOOL 10.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.88 11-13 >516 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horc(CT) 0.51 9 n/a nits BCDL 7.0 Code FBC2017/TP12014 Matrix-MSH Weight: 191 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP 240OF 2.OE `Except` B7: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 `Except* W3: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-13 oc pudins. BOTCHORD Rigid ceiling directly applied or 4-9-14 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min. 0-1-12) 9 = 149010-7-10 (min. 0-1-8) Max Horz 2 = -165(LC 10) Max Uplift 2 = -400(LC 12) 9 = -400(LC 13) Max Grav 2 = 1490(LC 1) 9 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2650/1686, 3d=433812666, 4-5=-3190/1839, 5-6=3086/1861, 6-7=-3169/1875, 7-8=-4314/2671, 8-9=-4679/2899 BOTCHORD 2-16=-131712292, 4-14=-235/447, 13-14=-213013992, 12-13=-189613634, 11-12=189913609, 9-11=-2480/4214 WEBS 3-16=-1451/921, 4-13=-1132/971, 7-13=-817/745, 7-11=-315/578, 8-11=-340/441, 14-16=-1567/2749, WEBS 3-16=1451/921, 4-13=-1132/971, 7-13=817(745, 7-11=3151578, 8-11=340/441, 14-16=-1567/2749, 3-14=-718/1558,6-13=-1270/2322 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 5) `This truss has been designed for a live lead of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 400 lb uplift at joint 2 and 400 lb uplift at joint 9. LOAD CASE(S) Standard Job Truss Truss Type pry Ply A0280555 WRMSCM1560BlL A09 ROOF SPECIAL 1 1 Job Reference o 0ona1 A-7 RooT Trusses, Fort Pierce, FL 34 b, oesignLaluuss.mnn Run: 8.210 s May 182018 Print: 8210 s May 182018 Mi fek Industries, Inc. Thu Aug 22 13:41:10 2019 Page I D:Id_OOXyyT61Bi_TXo ljwHHzetvK-7NBVyjzBeloS9EyLSo?rTMJh7HRgOABUgFmyll7 1 ]-6.4 11-00.12 14-0-1 1fiA1 19-0-0 21-&15 23-7-15 -0. 30-512 38-0-0 94 1 78d 4-0-8 2S5 2d-0 2 15 2315 - 2-0-0 14 5d11 74 1-4 6.00 12 5x6 1.5x4 II Dead Load Defl. = 7/161n 85x6 6 ] 2zd II 3x6 O 1.5x4 If 4 9 3x8 MT20HSc - 4 5 V 3 5 3x4 i d 10 3x4 3 11 17 Y W2 5x8= W9 0 r 1615 5 b 2 3 MA = 3x8 MT20HS� 14 'qi 1 3.00 12 3x8 1.5x4 II 12Lm 20 19 3x6 = 6x6 = 2x4 11 3x8 19-1-12 7: 11-00.12 18-1P4 19A-0 25-0 1 2&1-9 30512 38be 7-6-4 d-4-8 6-11.8 04142 5Ir 1p5 b1A 2d3 7.6i 0-1-12 Plate Offsets X,Y 6:0-3-0 0-2-0, 12:0-0-10,Ed a f 8:0-240-3-0 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.45 15-17 >999 360 MT20 244/190 TCDL 16.0 Lumber DOL 1.25 BC 0.79 Vert(CT)-0.8217-18 >555 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.92 Horz(CT) 0.51 12 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix-MSH 'Weight:2041b FT=10% LUMBER - TOP CHORD 2x4 SP No.2'Except' T5: 2x4 SP M 30 BOT CHORD 2x4 SP 2400F 2.OE'Except' B1: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except- W3: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 4-10-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1490/0-7-10 (min. 0-1-12) 12 = 149010-7-10 (min. 0-1-8) Max Horz 2 = -147(LC 10) Max Uplift 2 = -385(LC 12) 12 = -385(LC 13) Max Grav 2 = 1490(LC 1) 12 = - 1490(LC 1) WEBS 3-20=13911874, 6-17=-369/956, 8-17=.393/974, 8-15=-789/936, 18-20=-1531/2723, 3-18=-591/1396, 6-18=-876/1043, 9-15=-306/346, 11-15=575/572 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psQ h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-M tall by 2-0-0 wide will fit between the FORCES. (lb) bottom chord and any other members. Max. Comp./Max. Ten. -All forces 250 (lb) or less except 7) Bearing at joint(s) 12 considers parallel to grain when shown. value using ANSI/rPI 1 angle to grain formula. TOP CHORD Building designer should verify capacity of bearing 2-3=-2654/1667, 34=-4164/2502, surface. 4-5=-4068/2516, 5-6=-4195/2687, 8) Provide mechanical connection (by others) of truss 8-9=-4018/2571, 9-10=-3952/2402, to bearing plate capable of withstanding 385 lb uplift at 10-11=4023/2384 11-12=4652/2817. joint 2 and 385 lb uplift at joint 12. 6-7=-3504/2089, 7-8=3504/2089 BOTCHORD 2-20=1300/2296, 5-18=-253/307, LOAD CASE(S) 17-18=-1364/3106, 16-17=-1344/3097, -Standard- 15-16=-1351/3078, 14-15=-2410/4200, 12-14=-2404/4184 WEBS 3-20=1391/874, 6-17=-369/956, 8-17=-393/974, 8-15=789/936, 4 Flr.>a s.�gFy,.k.n. �ao0rtiawsfsc�n`Ave*eEQe�,FAus.+a GamRmxccllsmtlEx. 4NarYu xrvm.��uemmmv �a�,p..�,�«..ia rem,,,�mvem�amlw �+�¢e tiam.ndw r smeMe*c��.¢+� m. inrrm.,,nca ma ivnaHnmm��..cw.d�+�Y. a 7.mm4ln E,a�+m ,se.*me.Tweeede x•> mrywmErsaa•- ;api,.arY elewg�dma iaaa m.ieom w.7f61,iM arts e�.....,�eazar.a,¢.d``aib�r 7r"'� c•eW..,.mroo,2we«®m om,P.e0ailsbEaie9O%IW i'° We9msrn AAve+ed Mvtc.`Oa+e4b� lPl I4,��5"�w3'-"P�?'�. 9wn pi4BAiMzWmW"aMbtlM �4➢ea, dMSa'm},'�i.ativyrm'S^3+,N2e.n5Y'IeMa2bcl,6�Ltl�'�*,.m'NMI .V,�namoiwas¢zme 1MtleNWSa r/pN�InGG91816 . Y1Mppm2NL.e1W�l3pYW tlLi 5a¢Jr�B'MGCo1WAr FA fOiNm eiaRMMWR4y.ID�YS�aaa'^ad�&Aigih'gm'MSIMNmm�:w 1B6L09?�s14]%TR9tl6BLA�t4 relaeecGa]sSr�!a9MCmg SMMPmtAnres�.91�ieimK MSt 91�Ce aP4 FL P'a,u.R91Nfi 4WrYMTOTMPti%�a�5A�M9eNr�' <TRm W�u�a=vef.abe„cp,!@eaeSM14➢I Coaxal ep(Jv�nq MN64trPd�enud. e3 ThYfilaRW FMv� lNTA BWS>-0�?�.`,�mTrm?)i� ?i¢R[M a mNN+`3M fL. omc oarzYtols i>ptlMIIeafrom:swaaer.,:dntalC'CmmeYSCiOasAl Pamimve-'Araadaia.•mmamaviritAunrmn.hYFloblsa.ewrv».ec�i' m NM I'mxTmns, ' Job Truss Truss Type Oty Ply n A0280556 WRMSCM1560BIL A10 Hip 1 1 Job Reference o 6onal A-1 Roof Trusses, Fort Pierce, FL 34946, design@altiuss.mm, Run: 8.210 s May 18 2018 Pnnt: 8.210 s May 18 2018 Mi rek Industries, Inc. Thu Aug 22 13:41:11 2019 Page 1 D:Id_0OXyyT61Bi_TXoliwHHzefvK-ps6VbU WaTGJVMyt LofthLDNfJj2fOxCYPoDOnCv1176 1431 F4 773399 11-1042 1O8-732417--25 I d 279 947.2 W424-0 5 38-0-0 9d-0 5.6 11 - 6.00 12 1.5x4 II 5x6 6 7 8 4z6 6 4x6 i 3x4 4 4 6 3 16 W2 17 6x8= 15 14 3x4 4x6 2 3 x8 : 3z4 0 1 3.00 12 1.5x4 II 10 13 3x4 c Dead Load Defl. = 7116 in 20 19 3x6 = 4x6= 2x411 Us 739 11-10-12 1431 19-0-0 23-3-15 25-8-0 31-7-1 38-M 7-3-9 4-7-2 2-95 43.15 4315 T 5-11-2 6-415 Plate Offsets (X Y)- 14:0-3-0 Edgel 19:0-3-0 0-3-01 T11:0-0-10 Edml 118:0-5-4 Edbel LOADING (Pat) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(L-) 0.49 16 >940 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.88 16 >516 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.71 HOrz(CT) 0.56 11 We We BCDL 7.0 Code FBC2017ITP12014 Matrix -MS Weight: 2021b FT =10°/ LUMBER - TOP CHORD 2x4 SP M 30'Except' T2,T1: 2x4 SP No.2 BOTCHORD 2x4 SP 240OF 2.OE'Except' B1: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W3: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 24-14 oc pudins. BOTCHORD Rigid ceiling directly applied or4-10-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1490/0-7-10 (min.0-1-12) 11 = 149010-7-10 (min.0-1-8) Max Horz 2 = -131(LC 10) Max Uplift 2 = -371 (LC 12) 11 = -371 (LC 13) Max Grav 2 = 1490(LC 1) 11 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2665/1655, 3-4=-4180/2468, 45=-4099/2483, 5-6=3712/2217, 6-7=-4761/2730, 7-8=4761/2730, 8-9=-3782/2189, 9-10=-4541/2886, 10-11=4651/2765 BOTCHORD 2-20=1294/2309, 5-18=-252/353, 17-18>1907/3788, 16-17=-1544/3375, 15-16=1547/3396, 14-15=-1555/3382, 13-14=2203/4032, 11-13=-2365/4179 WEBS 3-20=-13361842, 18-20=-1512/2693, 7-16=-269/219, 3-18=-565/1382, WEBS 3-20=-13361842, 18-20=-1512/2693, 7-16=269/219, 3-18=565/1382, 6-17=-343/474, 8-14=261/455, 6-16=-858/1772, 8-16=-846/1745, 9-14=-614/629, 9-13=253/304, 5-17=520/466 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPl 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 Ib uplift at joint 2 and 371 lb uplift at joint 11. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply A0290557 WRMSCM1560B1L All Hip 1 1 Job Reference o tional A-1 Koo1 I mSses, FOR vierce, rL J4 b, aesigngal Vuss.com 6.6 = Kun: mziu s May iu zuio enni: o2lu 5 May 1 o zulo mi i 4x4 = 5 Sx8 = 2x4 II 4x4 = 6x6 = 6 7 8 9 22 -' 20 -- '- 19 18 3.6 = 1.5x4 II 3.6 3x8 = 6x8 = 2x4 II 4x8 c LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) -0.41 18 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.31 Vert(CT) -0.76• 18 >598 240 BCLL 0.0 Rep Stress Incr YES WB 0.75 Hom(CT) 0.45 12 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP 2400F 2.0E `Except* T2: 2x6 SP 2400F 2.OE BOT CHORD 2x4 SP 2400F 2.0E *Except* B4,B5: 2x6 SP 2400F 2.0E WEBS 2x4 SP M 30 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-6-8 oc pudins. BOT CHORD Rigid ceiling directly applied or 641-0 oc bracing. WEBS 1 Row at midpt 6-19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min.0-1-8) 12 = 149010-7-10 (min.0-1-8) Max Horz 2 =- -114(LC 10) Max Uplift 2 = -354(LC 12) 12 = -354(LC 13) Max Grav 2 = 1490(LC 1) 12 = 1490(LC 1) FORCES. (Ib) Max. Comp -/Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2704/1665, 3-4=2179/1418, 4-5=-1888/1354, 5-6=2071/1463, 6-7=-5615/3204, 7-8=5649I3220, 8-9=-3715/2225, 9-10=-4103/2393, 10-11=4749/2981, 11-12=-4790/2830 BOT CHORD 2-22=1318/2354, 21-22=-1318/2354, 20-21=-131812354, 20-29=-1025/2077, 29-30=-1025/2077, 19-30=1025/2077, 16-17=-2319/4733, 15-16=-2146/4089, 14-15=215114070, 12-14=-242814338 WEBS 3-20=-555/495, 4-20=-4151734, WEBS 3-20=555/495, 4-20=-4157734, 9-16=-955/1705, 11-14=-236/311, 6-19=-379511935, 5-20=-5311268, 8-16=-17131913, 8-17=-788/1576, 17-19=-2124/4332, 6-17=2531/5150, 10-14=-407/418,10-16=-364/388 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 6) Bearing at joint(s) 12 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 364lb uplift at joint 2 and 354 lb uplift at joint 12. LOAD CASE(S) Inc. i nu Aug zz 13:91:11 zu Ia rage VMyl LofthLONmbj9nOxZYPoDOrCyll7 go-0 �9d-0 i6-15 11 Dead Load Defl. = 318 in M 9' - M� of 72 131q i8-0-0 i-6-15 PLATES GRIP MT20 244/190 Weight:246lb FT=10% Job Truss Truss Type Ory Ply n A0280558 WRMSCM1560B1L Al2 Hip 1 1 Job Reference (notional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@attmss.00m 5x8 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek 4x4 = 5x12 = 5x6 = 5x6 = 5x8 // Inc. Thu Aug 2213:41:122019 Dead Load Dell. = 7/16 In 2IY n ra ra v 3x6 = 3x4 = 3x6 = 5x8 = 3x4 II 4x8 3x4 = 77-0-0 77-0-0 I 134-I 112-9 12-003 2331 83-2�1131 38-0-0 5-8-15 Plate Offsets (X Y)— r4:0-2-0 0-3-01 16:0-3-8 0-2-121 rl l:0-2-11 0-0-101 f14:0-2-8 0-4-121 116:0-3-15 Edoel f18:0-1-12 0-1-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. .in (loc) Well Uri PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.53 16 >853 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.98 16 >466 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.80 Horz(CT) 0.51 11 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MS Weight: 249lb FT= 10% LUMBER - TOP CHORD 2x4 SP N0.2 •Except• T2: 2x6 SP 240OF 2.0E T3: 2x4 SP 240OF 2.0E BOT CHORD 2x6 SP 240OF 2.0E *Except* B1,B2: 2x4 SP 240OF 2.0E WEBS 2x4 SP 240OF 2.0E BRACING- TOPCHORD Structural wood sheathing directly applied or 3-2-6 oc pudins. BOTCHORD Rigid ceiling directly applied or 5-10-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148910-7-10 (min.0-1-8) 11 = 148910-7-10 (min.0-1-8) Max Horz 2 = -101(LC 10) Max Uplift 2 = -340(LC 12) 11 = -340(LC 13) Max Grav 2 = 1489(LC 1) 11 = 1489(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2679/1701, 3-4=2317/1457, 4-5=-2313/1576, 5-6=2441/1644, 6-7=-8194/4589, 7-8=-8739/4865, 8-9=-5950/3417, 9-1 0=-4394/251 9, 10-11=4821/2858 BOT CHORD 2-21 =-1 364/2361, 20-21=978/20091 19-20=978/2009, 18-19=-1181/2310, 7-16=-1 12/324,15-16=-3099/6097i 14-15=1994/3989, 13-14=2490/4410, 11-13=-2470/4374 WEBS 3-21=408/447, 4-21=127/439, WEBS 3-21=-408/447, 4-21=-127/439, 6-16=-3226/6301, 6-18=-3066/1648, 16-18=-185913630,8-15--1856/1014, 9-15=1346/2562, 9-14=-154/304, 10-14=-033/470, 8-16=-1630/3138, 5-19=519/301, 5-18=1321308, 4-19=368/637 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf, h=15ft; Cat. Il; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4)AR plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chord live load nonooncurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 340lb uplift at joint 2 and 34016 uplift at joint 11. LOAD CASE(S) Standard Job Truss Truss Type city Ply A0280559 WRMSCM1560BIL A13 Hip 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com Run: 8.210 s May 18 2018 Pdnt: 8.210 s May 18 2018 Mitek Industries, Inc. Thu Aug 22 13:41:13 2019 Pagel ID:ld 0OXyyT61Bi_TXoljwHHzefvK-IEEFOAYr?uZDCFBkv4v9QeT5yWgrUsBps6il155y1174 9-0-0 1 44 5 2 7 ga44--77 13i7 1//2.6 1738 19-0-3 242'4 a53A 29-0-0 334Y0 3&0.0 agu '11L 4-0-15 338 14 4- 7 913 3 1 0 4-9.12 M l 1V12 409 I SO-0 az9 3xa _ 6x6 G 1.5x4 11 3.6 = 1.5x4 11 6x6 6.00 12 3x4 4 5 6 7 9 9 T 3x4 =.10 11 4 3x4 i i t 2 7 0 2826 25 32 31 29 48 = 3x6 = 4x4 = 1.5x4 II 5x8 =4x4 = 2x4 II 3x4 11 2x4 II 23 20 21 19 18 2x4 11 3x6 II 4x8 = 2x4 11 7x8 = 3x4 J 12 17 16 15 3.6 = 1.5x4 11 314 = 9-0 8 7 19 21E a15 7-4_ _ 7 8r2-15 13+7 17-1 . 19dA]pA,B 253-0 29-0-0 3349 38-0-0 oats 344 1 4-0-] a1-e I'IW 108 I ~34-12 4-04 s44 e-14 0-14 1-3-12 0-7-9 3x6 = Plate Offsets (X Y)- r5:0-1-12,0-1-121 rl1:0-1-12 0-1-121 r21:0-24 0-4-41 r30:0-5-12 0-2-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.06 15-38 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.07 28 >999 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.68 Horz(CT) 0.02 13 n/a n/a BCDL 7.0 Code FBC2017frP12014 Matrix -MS Weight:248lb FT=10h LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 `Except` B2: 2x6 SP No.2, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structuml wood sheathing directly applied or 5-3-14 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 734/0-7-10 (min. 0-1-8) 19 = 1771/0-7-10 (min.0-2-1) 13 = 482/0-7-10 (min. 0-1-8) Max Horz 2 = -85(LC 10) Max Uplift 2 = -202(LC 12) 19 = -710(LC 9) 13 = 307(LC 8) Max Gmv 2 = 750(LC 23) 19 = 1771(LC 1) 13 = 512(LC 24) BOTCHORD 2-32=425/1015,27-30=-176/714, 26-27=-265/913,25-26=1471790, 24-25=40/378, 22-24=40/378, 21-22=0/283, 18-19=423/370, 16-17=732/512,15-16=-732/512, 13-15=732/512 WEBS 19-21=-170911450, 11-17=483/278, 5-2,210/369, 30-32=-330/800, 12-17=394/630, 6-25=-272/233, 5-25=-261/202, 7-25=4841733, 7-21=-1130/680,10-18=-535/392, 18-21=-232/267,10-21=-858/1012, 11-18=512/546 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water FORCES. ( ) ending. Max. Comp /Max. Ten. - All forces 250 (Ib) or less except 4) This truss has been designed for a 10.0 psf bottom when shown. chord live load nonconcument with any other live TOP CHORD loads. 23=-11801643, 34=-1059/566, 5) `This truss has been designed for a live load of 4-5=-889/511, 5-6=-610/338, 20.Opsf on the bottom chord in all areas where a 6-7=-610/338, 7-8=526/809, rectangle 3-6-0 tall by 2-" wide will fit between the 8-9=-526/809, 9-10=-518/800, bottom chord and any other members. 10-11=0/251, 11-12=-261/541, 6) Provide mechanical connection (by others) of truss 12-13 -625/957 to bearing plate capable of withstanding 202 lb uplift at BOT CHORD ---joint 2�tO lb upliftatjoint-19 and 307-Ils uplift at Feint - 2-32=-425/1015,27-30=-1761714, a 26-27=-265/913,25-26=-1477790, 24-25=40/378, 22-24=401378, 21-22=0/283, 18-19=423/370, LOAD CASE(S) 16-17=-732/512, 15-16=-732/512, Standard QCnau%amylry,vre�M'k1 RO.7F185E5GENERV, i Nx..aCOi+otmxs Wsip4[w-n3uvan Auw+WrtEOGazEx„+a,n..veatAJr�w P^a^+eY+.w,ea8 a„ssTra➢evT�+*e4iD%u,udw. S+®%BgM1m,aMe+u dwlMmetw lnWeae.M�P:.aQmMNO and pTMWmcvaiJ®L1W 4+md1mNRWkta varn .laaTwaRryn &mzriaGl ,aC!oaH. �uYmev(TOO,,mi9>oR'+m JaWB Wnlq PE63CR aaapuiudYe p.ale+e6nallNxrvatl���dbbf+ONyr c(C�wgbS,mdeG lmtla]ma y.mdjNd.Thrtlwp ��mpma,hLLyuWJmm 9Wt/W uwN Op iry vp9u"iNa1 PanesywYgyaW NbY Wuw 6gMerirq CA 9,6t5 NIIw�a..�,c��e.ymr.xma,+sw ova.,mw�,.aau.l3ca.�e¢�ams�s.ee..aamy.u:aew�mm.run.,as�vmuxe.am.m��=e*�s.�o.r�.se,amma�vwoe.u,.asaa Swv- us, stww e�.a. el oevbeumai: N asemrmnwae o-abtJvmcw�+.artl�e.ea,vmaa�¢�seabA�^✓��ON�aa }'rPb+nsagwk�ne�eeiate^boWavb. 'rnzbnedenrt�v,o-isywz ttw,a,Rsww WYu-.Mtivxrs D+a44^ar,40+'as'Y P+�Ge®trWTMnMYwbdwt.'®Lai�vTg» Ae6�62l Co�M,.l+9�.eCa�m�w6E[I�OeVath®rM.iM"6M'sNb9V9sNOTMBWrN W%'P✓.wTrvRsl4mh S:31MP,NNi'�".4 EP �tl¢: OYl3R%8 caozuwfmm+eea4rn.amxaH twi�1{:ins),.,4mxvueae-Aeecbsm�aaea.a+r:-mev4Pxibm.Awc. ad.mwvrcv}me�M+�.aameA-1patr Job Truss Truss Type Oty Ply A0280560 WRMSCM1560BIL A14G Hip Girder 1 1 LbRferencei.Pti.r.13 A-1 Roof Trusses, Fort Pierce, FL 34946, design@atbuss.com 6.00 12 3x4 i 22 2 �1 9 3x6 = 44 = 1.5x4 Run: 8.210 s Mav 18 2018 Pdnt: 8.210 s Mav 18 2018 MiTek Industries. Inc. Thu Aua 22 13:41 45 46 23 47 48 22 28 26 25 4x10 = 2x4 It 3.6 5x8 = 2x4 11 3x4 II 1.5x4 II Dead Load Den. = 1181n 3 6 - 4x10 Sx6 = I7 9 1.5x4 i w 11 I 1IV 1 1 d 2 m q m 131q 1 2 49 21 18 ��.p 19 51 52 53 16 1554 55 14 3x4 II 3x6 II 5x6 = 3.8 = 3X6 = 2x4 II 8x12 = 8-0 19-&15 21. 3 4-0-0 ]-0a 8-2-14 11-11-15 13-10-710.10.1 19d7 2 12 264-2 31-0-0 38d-0 ba-0 3-00 1 2 4� 3-7-8 1-1" 1 2.11-10 2s8 a9-8 '1J-1 4-7-e. a-7-1a 0-1-8 0.10.8 Plate Offsets (X,Y)- 14:0-1-12,0-1-121,110:0-3-0,0-2-01,f16:0-0-0,0-1-121, f16:0-2-0,0-3-01 f19:0-4-4,04-0] (27:0-5-12 0-2-121 (29:0-2-00-1-81 LOADING(psf) SPACING- 2-M CSI. DEFL, in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.98 Vert(LL) 0.13 23-24 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.22 23-24 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.72 Horz(CT) 0.07 12 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MS Weight:229Ib FT= 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 `Except* B2: 2x6 SP No.2, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 `Except` W8: 2x6 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0-7 oc puriins. BOT CHORD Rigid ceiling directly applied or 5-2-13 oc bracing. WEBS 1 Row at midpt 6-19, 9-19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1304/0-7-10 (min. 0-1-9) 17 = 3893/0-7-10 (min. 0-4-9) 12 = 745/0-7-10 (min. 0-1-8) Max Horz 2 = -69(LC 6) Max Uplift 2 = -452(LC 8) 17 _ -2047(LC 5) 12 = -582(LC 4) Max Grav 2 = 1310(LC 19) 17 = 3893(LC 1) 12 = 756(LC 20) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOPCHORD 23=-2379/815, 3-4=2603/924, 4-36=2318/846, 36-37=-2318/846, 5-37=-2318/846, 5-38=-2318/846, 38-39=-2318/846, 6-39=-2318/846, 6-40=-925/2049, 40-01=-925/2049, 7-41=-925/2049, 7-8=932/2058, 8-42=-932/2058, 9-42=-932/2058, 943=-832/917, 43-04=-832/917, 10-44=-832/917. 10-11=-972/996, Continued on page 2 TOPCHORD 23=2379/815, 3-4=2603/924, 436=2318/846, 36-37=-2318/846, 537=2318/846, 5-38=-2318/846, 38-39=2318/846, 6-39=-2318/846, 6-00=925/2049, 40-41=-925/2049, 7-41=-925/2049, 73=-932/2058, 8-42=932/2058, 9-42=-932/2058, 9-43=832/917, 43-44=-832/917, 10-44=832/917, 10-11=-972/996, 11-12=1182/1050 BOT CHORD 2-29=716/2082, 28-29=-120/292, 24-27=-706/2154, 2445=-791/2353, 45-46=-791/2353, 23-46=-791/2353, 23-47=100/691, 47-48=-100/691, 22-48=100/691, 2249=-100/691, 20-49=-100/691, 20-50=-156/901, 19-50=156/901, 17-52=-1109/496, 52-53=11091496, 16-53=-11091496, 15-16=-11091496, 15-54=371/40, 54-55=371/40, 14-55=-371/40, 12-14=894/1022 WEBS 17-19=365311872, 7-19=-497/314, 27-28=33/415, 4-27=1351692, 5-23=-594/362, 6-22=0/295, 6-23=-786/1893, 6-19=-3163/1277, 9-15=-220/319, 15-19=-853/1137, 9-19=-2382/1577, 3-29=-374/165, 27-29=610/1832, 3-27=-263/355, 9-14=-567/1025 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf, h-15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 452lb uplift at joint 2, 2047 lb uplift at joint 17 and 582 Ib uplift at joint 12. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 239 Ib down and 249 Ib up at 7-0-0, 106 Ib down and 116 Ib up at 9-0-12, 106 Ib down and 116 Ib up at 11-0-12 ,106 Ib down and 116 Ib up at 13-0-12, 106lb down and 116 lb up at 15-0-12, 106 Ito down and 116 Ib up at 17-0-12, 106 lb down and 116 lb up at 19-0-12, 118 Ib down and 129 Ib up at 21-0-12, 44 Ib down and 71 Ib up at 22-11-4, 44 Ib down and 71 Ib up at 24-11-4, 44 Ib down and 71 Ib up at 26-11-4, and 44 Ib down and 71 Ib up at 28-11-4, and 152 Ib down and 194 Ib up at 31-0-0 on top chord, and 311 Ib down and 69 Ib up at 7-1-12, 84 It, down and 21 Ib up at 9-0-12, 84 Ib down and 21 Ib up at 11-0-12, 84 Ib down and 21 Ib up at 13-0-12, 84 Ib down and 21 Ib up at 15-0-12, 84 Ib down and 21 Ib up at 17-0-12, 84 Ib dawn and 21 Ib up at 19-0-12, 77 Ib down at 21-0-12, 145 Ib dawn and 139 Ib up at 22-11-4, 145 Ib down and 139 lb up at 24-11-4, 145 Ib down and 139 Ib up at 26-11-4, and 145 Ib down and 139 lb up at 28-11-4, and 399 Ib down and 393 Ib up at 30-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=60, 4-10=-60, 10-13=-60, 26-30=-14, 25-26=14, 20-24=-14, 18-21=14, 18-33=14 Concentrated Loads (Ib) Job Truss Truss Type Qty Ply A0280560 WRMSCM1560BlL A14G Hip Girder 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.cem Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:14 2019 Page 2 Odd _0OXyyT61Bi_TXoliwHHzetvK-DQceD W VTmBh4DPmwToQOzR6Dw5zDHL5mS2QXy1173 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-192(B) 8=-31(B) 10=-105(B) 28=311(B) 14=399(B) 22=-73(B) 6=-106(B) 36=106(B) 37=-106(B)38=-106(B)39=106(B)40=-106(B) 41=l18(B) 42=-31(B) 43=31(B) 44=31(B) 45=-73(B) 46=73(B) 47=-73(B) 48=-73(B) 49=-73(B) 50=-56(B) 52=145(B) 53=-145(B) 54=145(13) 55=-145(B) Job Truss Truss Type Qry ply' T. A0280561 WRMSCM15601311- B01G Hip Girder 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com IN Run:6.2105 May is 2U16 Prim: a21u 5 May 162016 MIlex In0UMes, inc. InUAUg2Z1J:41:1b2U1U 4xa = 3x4 = 1.5x4 II e. - 3x4 = 46 _ LOADING (psf) SPACING- 2-M CSI. DEFL. in (too) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) -0.11 6-8 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.20 6-8 >999 240 BCLL 0.0 ' Rep Stress lncr NO WB 0.23 Horz(CT) 0.07 5 n/a We BCDL 7.0 Code FBC20171TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 -Except' T3: 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-9-1 oc puriins. BOTCHORD Rigid ceiling directly applied or 6-7-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 1389/0-3-6 (min. 0-1-10) 2 = 1454/0-7-10 (min.0-1-11) Max Horz 2 = 80(LC 8) Max Uplift 5 = -475(LC 9) 2 = -502(LC 8) Max Grav 5 = 1389(LC 1) 2 = 1454(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2594/887, 3-15=-2196/826, 15-16=2196/826, 4-16=-2196/826, 4-5=-2535/868 BOTCHORD 2-8=-763/2244, 8-17=763/2264, 17-18=-763/2264, 7-18=-763/2264, 6-7=-763/2264, 5-6=7022177 WEBS 3-8=-7/601, 4-6=-7/578 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-secondgust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 475 lb uplift at joint 5 and 502 lb uplift at joint 2. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 239 lb down and 249 lb up at 7-0-0, 118 lb down and 129 lb up at 9-0-12, and 118lb down and 129 lb up at 10-3-4, and 239 lb down and 249 lb up at 124-0 on top chord, and 311 lb down and 69 lb up at 7-M, 77 It, down at 9-0-12, and 77 lb down at 10-34, and 311 Ib down and 69 Ib up at 12-34 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 4-5=-60, 9-12=14 Concentrated Loads (lb) Vert: 3=-192(B) 4=-192(B) 8=311(B) 6=311(B) 15=-118(B) 16=-118(B) 17=-56(B) 18>56(B) Load Defi.=1/1a in 5 R PLATES GRIP MT20 2441190 Weight: 81 lb FT=10% . gesao.wply <I>mo�•••misEEsrseuski.:. T6ausi,ecm+wrxa��JsT(aMmneamx:Eur-veer.a,,,.vdya�wa^re'�«area�.�c,>!..Trvmw.g, Q yp.e.q Fmw Mm elr9wmanuw lalbauwn.beg•$efd p TD4/�0^v teaer.IttnlMaeA 4amPaMTW kae X.e N'eTuwgeepaaDr.«p4.eagm.lrrEny,eyw..alweoYTovrs,eaaxi. ,we1BPnW VEauos [vpWeaab+e[w9vFmv9.q'urs&�ly OauAr, byM tla1DDmYtnCu T<Y.ThO �evgbem,lealnOYm<Fe+n wladYY+X��W Tmcbgpau¢Ly PYavp.,wYq/d9w. p.1iv�0e'uNia�eOe➢94 XYYR�T D�'�+.i�b N�PiMIR �vtlrlYR Fb IPJ�i TN �`K�'bv(1NSW mYtild.�dtlwTt��°�W�"^i�VA �J4mw],bW '�94'^-�YY NTob XCuu E,ginmNq GR91815 NS SI Wti�91M. .Uel94 tPLa6NW OnV�dmN,OiIn4P R04�=%'W w46Im0'RIn WMe PKA 9VG'+6�`+4beB NnArM4Ye'/�4HI�4maMn.IBSCPW�YYhiPIW PHCTie44rtzNA6eW2?�NW>^CZ Y�YANm'4 G RPlerce,R319N �eM��WX�?.. minllrm TavaRe9�"R,6pmTY e�BewSi4.iNaM4�iZM,rt.n�Bt^"Ja<+b�W 4itt�wWaGW1610R wv?^B bf�V�+aMAellly4F/BMCiWTM BmTN➢De?Pa(utnw SJFI^?Eei^Q�. &4 $�. Dale: O92VLi1B ['NMvmii4YmNmTiL1.'Cey�0al16ATRgttTrvssse-ANrvTaeondAF/. dmmnl.Na.tUnniPMa�nNSECeMleen Tm nM PMTwva _ Truss Type Qty Ply �bMS� A0280562 Hip 1 1 Job Reference o tional A-1 ROOT I mSSea, YOn rlerca, FL J4 b. deslgn(OlaltmsS.com 6.00 FIT 4x4 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:16 2019 030 4x6 =1.5a4 11 46 x 5.6 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (Joe) I/de0 Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(L-) -0.25 7-13 >929 360 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.43 7-13 >525 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 -Horz(CT) 0.02 6 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 'Except- T2:2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-3-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-11-6 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 699/0-M (min. 0-1-8) 2 = 789/0-7-10 (min. 0-1-8) Max Horz 2 = 95(LC 12) Max Uplift 6 = -176(LC 13) 2 = -215(LC 12) Max Grav 6 = 699(LC 1) 2 = 789(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1012/619, 3-4=-806/675, 4-5=-806/675, 5-6=-1017/622 BOTCHORD 2-7=-394/806, 6-7=394/806 WEBS 4-7=-8/372 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed: end vertical left exposed;C-C for members and forces 8. MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 176 lb uplift at joint 6 and 215 lb uplift at joint 2. LOAD CASE(S) Standard 0 4 4x6 = Dead Load per. = 3/16 in PLATES GRIP MT20 244/190 Weight: 69 lb FT=10% Job Truss Truss Type City Ply I" A0280563 WRMSCM1560BIL B03 Common 2 1 Job Reference (ootionaD A-1 K00T Imsses, rgn Viefna, r-L 39 . oeslgnigantnlss.com '4 Kun:n.zius rmayiazutuvnnr.a.[Tusmayluzulumnex 44 = 4 3x4 = 5x8 = 4x4 = LOADING(psf) SPACING- 2-M CSI. DEFL, in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Ve it 1( -0.14 7-13 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.27 7-13 >848 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.19 Horz(CT) 0.03 6 n/a nla BCDL 7.0 Code FBC2017/TPI2014 Matdx-MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-1-3 oc pudins. BOT CHORD Rigid ceiling directly applied or 7-4-3 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 699/0-3-6 (min. 0-1-8) 2 = 789/0-7-10 (min. 0-1-8) Max Horz 2 = 100(LC 12) Max Uplift 6 - _ -180(LC 13) 2 = -219(LC 12) Max Grav 6 = 699(LC 1) 2 = 789(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1175/797, 3-4=-866/597, 4-5=-863/595, 5-6=1159//82 BOTCHORD 2-7=-631/1022, 6-7=-610198.3 WEBS 4-7=-286/491, 5-7=328/363, 3-7=-364/386 NOTES- 1) Unbalanced roof live loads have been considered for this design. -2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcur ent with any other live loads. 4) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tallby2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 180 lb uplift at joint 6 and 219 lb uplift at joint 2. LOAD CASE(S) Standard 13:41 Dead Load Der. =118 in fiR PLATES GRIP MT20 2441190 Weight: 84 lb FT=10% i6cvT^aWN pARWF.T�$6E6 r69LIFry1GEa8Apt TEPM6M4Aie2�t6LY15tCYElt I:V&^JA�OWIELGkEM'Mm. Va )!�,]�� wbreaE gRLTrt�e a�sbm0.Wq{TOpYeMw R MER^�.mNnru lra� VMwemcMa!�W tMTRD. vgbkmNnws� �u4 TaevTW..M r0 Kalav �9weM1gfi46PF+MFnO'Y2P�N?an JamtB WnW FE6RW3 4t+P ptT00 ANeaman s?a'>tl%uP�+��butwesn�Wl�v�3bi s(aeypA il'+inr A6WlmuwYW ud¢Wolp-Llxad �ptlRanSdm. w�Wd+.f bdawN T b�ryB lab W-^gp"b'W dAre Vheb Mwa Wmee�N Ndf815 �mn e+'Y m.a..r...��•y+.N`h+a^.9»^^u�rtw mu.owbfawa+e.L<u,6curu�uaro�..aief.T na.�wmamm. m➢ Mr aw .rraw6+�^o pmbs. w�.es®.am.c�wm.my W#+lb dV....y.....yd�J Fk 2¢aIDPia6*MfieRW atlL�N+�w AMadbmOPmY®f SWM'fi�++��Ae6'�40oWslc]%TPtm kmaMbrpip�ID �I6liz ha sk us stuue ena 6'%'� NN®db/T.w MSS+✓.BR'+n4E9^P'NAiMmY}M+mmf.vJas,ut,BWn>M�+v3h'B CPMntIM�YPAn Mm3 tt1�Na8 �xGR11MSy0.+LLfErypa® NpT Pn 9xVNG 0e=Tn' ima 6Ys�T 6GS� mYM a-ra one�moirzms� tadlM-Mb�n+»w4uiMdiP�1.WpPn6`SN91BM1PatTrvuw�-MV+�a+N[b6i'm�tkm+^}Imrt:�PMUC4C�iTvlO9.nm�n vd,Nh�ReRTmw. Job Truss Truss Type OtY Ply A0280564 WRMSCM1560BlL B04G Half Hip Girder 1 1 Job Reference(optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210a May 182018 3x4 _ 1.0. II 414 LOADING(psf) SPACING- 2-041 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Ver 0.09 6-9 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.13 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.76 Horz(CT) 0.02 5 n/a n/a BCDL 7.0 Code FBC2017/iP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-1-0 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-2-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 802/0-7-10 (min. 0-1-8) 5 = 1059/0-3-6 (min. 0-1-8) Max Horz 2 = 166(LC 8) Max Uplift 2 = -264(LC 8) 5 = -384(LC 5) Max Grav 2 = 802(LC 1) 5 = 1059(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-1157/360, 4-5=-294/188 BOTCHORD 2-6=-377/959, 6-12=-377/980, 12-13=-377/980, 5-13=-377/980 WEBS 3-6=-8/626, 3-5=1170/453 NOTES- 1) Unbalanced roof live loads have been considered for phis design 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 lb uplift at joint 2 and 384 lb uplift at joint 5. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated loads) 260 lb down and 270 lb up at 7-0-0, and 118 lb down and 129 lb up at 9-0-12, and 120 lb down and 129 lb up at 10-10-12 on top chord, and 338lb down and 72 lb up at 7-0-0, and 77 lb down at 9-0-12, and 78 lb down at 10-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=60, 3-4=60, 5-7=14 Concentrated Loads (lb) Vert: 6=-338(F)3=-213(F) 10=-118(F) 11=-120(F) 12=-56(F)13=-57(F) Inc. Thu Aug 2213:41:172019 Dead Load Defl. =1/16 in PLATES GRIP MT20 244/190 Weight: 57 lb FT=10% Job Truss Truss Type Oly Ply Jt A02865 05 WRMSCM156OBlL B05 Half Hip 1 1 Job Reference (optional) s ..y 5x3 � 1.5x4 II 3 4 4x4 = 1.5x4 II 4y,4 = Inc. Inu Aug eG 10:4I:10 Nle Dead Load Deft. = 3116 In a LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.25 6-9 >566 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.33 6-9 >425 240 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(CT) 0.01 2 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MS Weight: 60 It, FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 •Except• T2: 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puritns, except end verticals. BOTCHORD Rigid ceiling directly applied or 7-5-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 527/0-7-10 (min. 0-1-8) 5 = 433/0-3-6 (min. 0-1-8) Max Horz 2 = 207(LC 12) Max Uplift 2 = -137(LC 12) 5 = -137(LC 12) Max Grav 2 = 527(LC 1) 5 = 433(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-434/146 BOTCHORD 2-6=-267/290, 5-6=-269/296 WEBS 3-6=49/323, 3-5=-572/520 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 Ib uplift at joint 2 and 137 lb uplift at joint 5. LOAD CASE(S) Standard Qwm.aome�smema •J., umsTNzses S�uaM caxrJw.Sve.,s.,ecwort,a+scisTovEPrsurvaTxwmw�aoBweJT•+s,a.v.rya.�p..�m[.[.dwa mmmavT,� o..� o-aav0�u�eee �'QY Fi^JbsarNw[M tlwILNn[.m.MM@M[(.eatq W100. m<!nL[n mmtlwmp@my 4[®1#Ba TSJbbVBW HeTun0.a[B�T^G^^^WM1a:SGF[HBN�'r). On tW m�npTW ,R+?TA'-f'BB JMIBDAhPFE VBN rsarMm dYmpm.[a.m+•P�-m^n m.m�'�b »s[gnJa+[m�[T.m 0.p'[<a rzro�..a.Tw-1.T,.1�„aw�bxf.�B,.a.e�...W,uerwre.aa.r Iv nT8�1^v=wmr[w[e"gme. vde wJw EnemeeMae[s, a15 w.s.no...i[wsww.aas�m,xew+•aoe'g.r ay.maedw.u4o.,aCbu,o-utrbem. TNT. acme'mme.mB.�amvrmiu»mv�['hw.eeMwlm��^ti��^w[.[amvm.m.emdna.wbw .m»+Bu�np4[Pefmia CaWpbt N�eeaafM T�r<ao G�mm[NP^mmm[m Pa SvStASHn�M.rm-s (ASW W4JMhTNs.aSBGt o"nM[xMN �� ! u5tS4W &+!. PEiKalO4T e[[4mi.6pckSY r+9T/�TM[4Mafue.NJ[p eTmSnbYTl ylCant+6 R^Mm Wbvw l4FfblFm PegmwpXr9 cN RPmm.Rd19,8 �[WmLimlbnymbmleel TGL 1.Cmpm¢CSf6 1POY T,u[o[-R[p,mm4m Wq[ •ByCjWnw•MM CIM�G[NaNMwt iM 6peNY E,9muen{IDT Om Bw7fiV Dedmu/m Trve ByM EepMrpfmp4eN;lb pay; yy/yp1B �Wjnmyfav[I[ptiv NueBy[.v,eipmnp[ggA1 PaRT,maa� Job Truss Truss Type Qry Ply A0280566 WRMSCM1560B1L B06 Monopitch 2 1 �J.bRefreroelmtl.nal) A-1 Hoof TNSSeS,roa vieroe, hL d U46, mslgn(galtrumcgm mum a.ziu s May ld ZUld Vnm: 6.21U S May Id ZUld Wax 1.Sx4 11 4 3x4 = 1.5x4 11 44 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(L-) 0.06 6-9 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.07 6-9 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.42 Horz(CT) 0.01 5 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-1-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 527/0-7-10 (min. 0-1-8) 5 = 43310-3-6 (min. 0-1-8) Max Horz 2 = 264(LC 12) Max Uplift 2 = -117(LC 12) 5 = -200(LC 12) Max Grav 2 = 527(LC 1) 5 = 433(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 23=-605/196 BOT CHORD 2-6=-4811483, 5-6=-4811483 WEBS 3-5=-549/547 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B: Encl., GCpi=0.18; MWFRS (envelope) _ and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117lb uplift at joint 2 and 200 lb uplift atjoint 5. LOAD CASE(S) Standard inc. nu Auq Z4id:41:id4Ulu PLATES GRIP MT20 2441190 Weight: 62lb FT = 10% Job Truss Type :17 ],Job A0280567 WRMSCM156081L CA CJi ComerJack Reterence(ootionah A-1 MWI rUeSes, ron rlerce, rL J4 O, aeslgnLa 1wss.MM KUn.0.em5 May W<U10Vnn1:0.L1U5May fomlDMuexmausme5,mc. 1nu NUg�-LZAJAU<Um LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.00 7 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 7 >999 240 BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 0-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -5/Mechanical 2 = 181/0-7-10 (min. 0-1-8) 4 = -21/Mechanical Max Hom 2 = 42(LC 12) Max Uplift 3 = -5(LC 1) 2 = -71(LC 12) 4 _ -21(LC 1) Max Grav 3 = 12(LC 8) 2 = 181(LC 1) 4 = 20(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 3, 71 lb uplift at joint 2 and 21 lb uplift atjoint 4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 6lb FT=10% w®u.awn,=,®e,.-saxmsEs^sEucm}cEHEwr_rEwrs.wconmrm+s wsmuEata�+vucxorr-cDsarvm m�vmvanw wm=+N.ra,e.,emwmwlmrJm�, nww ilmirmdce. r SA�wR'EN�^z-�mmrva eM ce�w.wwl.T�wvwb+#al'�m MIDD,�A'�Ne w^�' rJT uw mmM1oD(ab vNa, HeimvPsP'EW^mhG64�VE^G^WJbuY MtOD .elTmn.§n.. Jere18 D�mIaGPEBtBro a+a%anma#�OGMsscvaaln9s++��•e'w4'7�JMli P6Cmignd4�vgl�Sru bPtil.mMSW mM"mtla T9-Y.lf»Me� uD��baSv9cmA3un. Nrt)MwnglM �ss b..rBaa'Nrsb,mrLnatlMde+. Wlu�e Xcuss EM6 WnG G91615. -o.=s acwm'�bum&bgen b>•nBwirY IDwmaaim.wGueJe43ti1 taiemw ma mJn inem*ovu mump '. vmamam.xwamdis*min.?'°: J' �.m.mnmvam.en.w,wvv�eIDarx wsl aumeaw, MAe6YTPbm9+batl Hx¢iss1MiDDYdNSR+[de59tl6ubetiE9d�i+e&9Grt8LM1Pmm1;tlM'A�mRmla5Ca W61Ei�/T%sWEBLRwnkrercK3vX^dd9bE+•�5 '4PKMAeeWe�rntlGibeymd. n.Ruw.R318N u:,nwda.r,�mD±+i•�isvUomvwr.�aNmrt+m.r.we+.�maeaeae�mdb[c.;•a,+neeeae.wam�smhdwd+imacTh4aeawFietillni v. a�vYwoewdwararNnar�.nS, �.eaa.agw.q M Dm: aszvmin .vedlaSxN,nriaml6bfe�EmiPL1.�IXpYN�=QSMbIHAw[ry✓.-4�-RWr�i[fmNPv'[CWnw,h.nmYrm9.iPt�2hda'MM46 w-av� moalKf NtgSwR` Job Truss Truss Type Qty Ply A0286568 WRMSCM1560BlL CJ3 Comer Jack 7 1 Job Reference o tlonal A-i Koor i russes, ron rierce, rL :wsao, cesignLmanruss.com Ken:b.Llus Mayiuzuiuvnnt:b.2lus Mayima ula MlleK 2x4 = Inc. I nu A00 22 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl Ltd PLATES GRIP - TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 4-7 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.08 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB, 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/1-P12014 Matrix -MP Weight: 12 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 64/Mechanical 2 = 212/0-7-10 (min. 0-1-8) 4 = 23/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = -43(LC 12) 2 = -63(LC 12) Max Grav 3 = 64(LC 1) 2 = 212(LC 1) 4 = 43(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp 8; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left ezposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 Ib uplift at joint 3 and 63 lb uplift at joint 2. LOAD CASE(S) Standard 1 Job Truss Truss Type Qty Ply A A0280569 WRMSCM1560BIL CJ3B Comer Jack 1 1 Job Reference(optional) A-1 Roof Trusses, Fort Pierce, FL 3494ti, eeslgn(gal Wss.com p Kun:a.Zlus Mayla2ula Pnnt:a.ZIUSMay Ia ZUIa MIleK 3x4 = ' LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Udell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 3-6 >999 360 TCDL 10.0 Lumber DOL 1.25 SC 0.10 Vert(CT) -0.00 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-7 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 9510-3-6 (min. 0-1-8) 2 = 67/Mechanical 3 = 27/1VIechanical Max Horz 1 = 52(LC 12) Max Uplift 1 = -13(LC 12) 2 = -07(LC 12) 3 = -1 (LC 12) Max Grav 1 = 95(LC 1) 2 = 67(LC 1) 3 = 41(1-C 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13 lb uplift at joint 1, 47 lb uplift at joint 2 and 1 lb uplift at joint 3. LOAD CASE(S) Standard InG InUAU0221J:41:ZU2U19 PLATES GRIP MT20 2"1190 Weight: 8lb FT=10% Job Truss Truss Type Oty Ply A0288570 WRMSCM1560BIL CJ31- Comer Jack 2 1 Job Reference (optional) A-1 ROot Irusses, ron Fierce, FL 34946, deslgn(fDaltruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MMek Industries, Inc. Thu Aug 22 13:41:21 2019 LOADING(pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Val 0.01 4-7 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FSC2017/iP12014 Matdx-MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 64/Mechanical 2 = 212/0-7-10 (min. 0-1-8) 4 = 23/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = -43(LC 12) 2 = -74(LC 8) 4 = -29(LC 9) Max Grav 3 = 64(LC 1) 2 = 212(LC 1) 4 = 43(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber OOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to tmss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 3, 741b uplift at joint 2 and 29lb uplift at joint 4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 12 to FT = 10 NooVRb.wev N-A-I ROLFIt>ffd5E5 P6�11F f6EHFAAi iENASNGW®fCXS C.rSTONEAf9N$Y{FCItbBIMEBGV�iP'Mm.Ymi3�[P®aTd°^�'Ra1.w�ou OA Traa:Oe9^SYa�m9R69}'vMW. QAea9e f Sa"`%EMhw,Wmu dgyuPlm�ys uweMrAf?+>pn M%bB. w.rYA�.lv'm mwpyOkln eiW eeamb9+rzgya.2aY� NeTMs�%9^�C��Gka:eq�ryErPv,®rJ MmalonarRTOO �y�?ep1ln •�b+sa WlCNc[wnaYp'H'n+'iV���a[�blv`f3deiq,NUa�^9k ium �rP�m T06cdvmim}WY tMtivO,m^Iu9dvEM[TGAcn.maaMR%adir.WLL¢Tw t!n'IBudWvll�mp'M3�.gAe. JawBBunIIDPEfi3W3 NInk X[Y£e EnBMeM4 CA 91615 .duv. C+to�4Na:Jlu+maa3[aul+[BW NE'p9"•!�➢Y�w+dam[R4N+IBO.tra(mQ`W m4KiTPJF 1N iq`en'YlBtra'1Lp sN RYhb w.ed3n11�m.:��MMnq.[%Iv.�.mWM+FIm'vl.aY•uYAva[[am9PwY' uSl Slui[BM. a>b�✓-['9TbryM[wBLanY�t AlnmeeSCMn(me TBIIe�Mw�?bmxGa�HCPmeB�Gm3Fl5[ovm[StlNY1^IvmYmIaSWP4RWNM'1Ptud S6CAYt+ebre tllwp^i'I1P[dTk TPMhM1 Stlwreryv�W[4;ud M1OTW B[#NiO�ttTNv.SNIS e'%ieWafMIA [YJAn�[[R d�[uC6vgimwiRTs)fwne Fl. Rau.R31918 U9e 0624i➢tb Ewa'9[M�Ybi,e[m`m�1Ab(M)�<rNBAt kvcl�T clNutRtl[6bEP�a°WThTSN���M'F[9RRSA pneownaM1l RwtTrsps„ Truss Truss Type Oty Ply sob A0280571 WRMSCM1560BlL CJ5 Comer Jack fi 1 Job Reference (optional) A-1 rcoor 1 cusses, ron rierce, ru .warn, cesign0a iuuss.com nun: o.zru s may to zu ie rnm: o.znu s may is zuin mueK mpusmes, ma i nu Aug zz nsarn zuia ID:Id_0OXyyT61Bi TXoliwHHzetvK-WnjHhves7La4zUoGNm2llKoT0laKMdjOiMei YMC 4-11-11 LOADING(psf) s SPACING- 2-M CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 We me BCDL 7.0 Code FBC2017fFPI2014 Matrix -MP Weight: 18 Ib FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 122/Mechanical 2 = 27810-7-10 (min. 0-1-8) 4 = 48/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = -73(LC 12) Max Grav 3 = 1221LC 1) 2 = 278(LC 1) 4 = 77(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 Ib uplift at joint 3 and 73 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type OtY Ply A0280572 WRMSCM1560B1L CJSA Comer Jack 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:22 2019 Page 1 ID:Id_OOXyyT61 Bi_TXo 1jwHHzefvK-_zHfuFfUuf[xBeNTxTZGIXKgw8xJ54z9xOOTf3yl I6) -1-4-0 4-2-0 1-" 4-2-0 I 2x4 = 42-0 LOADING(psf) SPACING- 2-0-0 CS1. DEFL in (loc) I/deft L/d PLATES GRIP - TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.02 4-7 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.18 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MP Weight: 16 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-2-0 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 99/Mechanical 2 = � 250/0-7-10 (min. 0-1-8) 4 = 39/Mechanical Max Horz 2 = 106(LC 12) Max Uplift 3 = -66(LC 12) 2 = -68(LC 12) Max Gmv 3 = 99(LC 1) 2 = 250(LC 1) 4 = 63(LC 3) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding fib lb uplift at joint 3 and 68lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply A0280573 WRMSCM1560BIL CJSC Comer Jack 1 1 Job Reference(optional) -A-1 Roof Trusses, Fort Pierce, FL 34946, design@aft uss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:22 2019 Page 1 ¢ ID:Id_OOXyyT61B=TXo1jwHHzefvK-_zHfuFfUufixBeNTxTZGIXKeW8uw54z9x0OTf3Al6x 477 4-7-7 314 = 4-7-7 4-7-7 ' LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(-L) 0.04 3-6 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.04 3-6 >999 240 BCLL 0.0 ' Rep Stress Iner YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MP Weight: 15 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-7-7 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 169/0-M (min. 0-1-8) 2 = 121/Mechanical 3 = 48/Mechanical Max Horz 1 = 93(LC 12) Max Uplift 1 = -27(LC 12) 2 = -83(LC 12) Max Grav 1 = 169(LC 1) 2 = 121(LC 1) 3 = 74(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27,I1b uplift at joint 1 and 83 lb uplift at joint 2. LOAD CASE(S) Standard r any w-s�aarr�rtases rsaiF��,rsueuu.5w+s.xuwmrmnscusmueatem'arin�vivM. iu,ae-m-+�..v ti�wv�+^�u+••i�e manr�D�o...-wrtDDl �+^e t =�¢Y 6�➢F+� ro..el ta+knyee.IMWIXMMetl¢elmMiDD.m�-.A�atw'vfm g�pacL (a 9fTWb vAY OaM6A^^a�N SA0.R�.+�'J9^P)Pwvel mr1DD�,(rteMeaA JareIBOwJWPE6$6N h nW� a.�y^viq,�WZLfMb�ibn�d¢r�reMi,u�>dMimMTn.n3nrh17<rvNc^+'%+aveC��S^A ��'D�^�a'+�Yfaku�wW rvn,v vpB�tisg.w+mt/��+�bW.aYer.. NMIONause F^4MuiW G3mm,5 o.rse. 1 awYv+�weuwaRaw�+bv. m.webusuD,ee�a6adA�ga�e.vamlc �rueu.mD+@mrwd�o.auvDm•uimM�e'cad�w na.uwenram?e+a.we.m.+.+wnvA�r� un gwoe abe. .mseax+.q o�mwmem�o-wm rseaHwaaswtDDwa.w.��+trae�*neecmae�¢en,,,omuennYa+n��XDs�"aka¢Mrwa�nssenw.r.,..emYo.�z�.�+ewrxt' rv�rn.r n. �auiz..aa. x�,m.awsw �¢...no ir+aaDelprN�4tia59 eg1MrMUm u.,�nm..,,mrunn.mwax+ast<cow.dwAea."Pm"..n°^aM.6o.Y...ane.n.Tatw'®q,'ss���xore�ac*rm orYa!mw96�=E^ma9�.r�ti� Dae oasv¢m¢ 'Ga'+3a�®1MmA®Ntn+3alTai,: R'pyapt0'L'I6AYRv¢Tn¢yn-� ptrtlA¢Nvm�MMapY»m:pdEpWwpyfpg w'�Hn`OmnSvmnalN pa➢fT Job Truss Truss Type Oty Ply A028o574 WRMSCM156OBlL CJSL Comer Jack 2 FJbRefre,, o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@altiuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41 3x4 = LOADING(psf) SPACING- 2-M CSL DEFL. in (loc) I/deft Ud PLATES GRIP ' TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) 0.10 4-7 >563 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.09 4-7 >648 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and require tl cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 122IMechanical 2 = 27810-7-10 (min. 0-1-8) 4 = 48/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = -102(LC 9) 4 = -51(LC 9) Max Grsv 3 = 122(LC 1) 2 = 278(LC 1) 4 = 77(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when -shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 It, uplift at joint 3, 102 lb upliftatjoint 2 and 51 lb uplift atjoint 4. LOAD CASE(S) Standard 'm'n` w.t�p�w�w.+f.�nae:se=.^rE+a�.at !Q 4xaMFvi�r�a...a.ai,e(rum.�unrw+-,a.ewmp.roo.uqr^a,�ar«,�rc,ama.v,e..em.sarw»s.vaq 9�.ww,.,,6roo wfrr#.�•a+.n��a.ewem�v�aaYoeo�du.ara.x,e.>w�+?m,m.mo�5v..wn�maz�w �n��r>^�. �^sromam. mNywwaw+rw w+^r�a^sRa. .ora.: @IA b. ,w�meamdavE6mm wwi.wus. [*amxnne usi6�s (!v„bImnEYP^,4NBui�n3 Ca+a�M.b➢4lmeLd WLai.PaVb. ivlyn#r9W[Ma �.�t6�bIDO YM1vadMTi..aC-wtiW?+�9 Nd4.MY�MnNb.-?AM6M6'�rs6baAu #IDim: `a+pLeb�.nvPHrs6eammM.eae No'aaerey�e vtlmam.,aaAceuicm0=�u.Hanm+denYmR%3 e^mwmu/fPlm9�`:fl rabnectafmC�.'.!sWa�w 'iawRtlNilme Rse+dTamC N6�[N6n Trvn6N�.§�br+9m�tlA TNb Menfa9v�6MRl1`uf�muC, A6eG6p{Ce,6aclgwG.vP"/�n..9e`SKaP�V�b6�'.%�M"UReaY x+pN(RRlhi P1�B!M'W De%iFmi,�6YaM, Eh0�Pf6IN�0'.�Pi fA S1SLWe Bhtl. R�Svm.Raaere OflR4RMB uap19iW 1acsvRic6ha1njP41.�1gftDYf6A14m�irvEsn-jlpyrW¢tlntpp(A[miW.b"¢.j( .YAGi2iWMPaJ4ya+Wn`J.npamnMAY{ Trmc' Die: Job Truss Truss Type Oty Ply A0280575 WRMSCM1560BlL CJ6 Comer Jack i 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:23 2019 Page 1 ID:Id_OOXyyT61Bi_TXolMHHzefvKS9rI6bf6fyg000yfVA4VgltnlYD5gXCJ9g70B Wy116w -1-4-0 5-8-0 1-0-0 ~ 5-8-0 2x4 = LOADING(psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 TCDL 10.0 Lumber DOL 1.25 BC 0.40 BCLL 0.0 Rep Stress Incr YES WE 0.00 BCDL 7.0 Code FBC2017/7P12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-8-0 oc purins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 141/Mechanical 2 = 302/0-7-10 (min. 0-1-8) 4 = 56/Mechaniml Max Horz 2 = 137(LC 12) Max Uplift 3 = -94(LC 12) 2 = -77(LC 12) Max Grav 3 = 141(LC 1) 2 = 302(LC 1) 4 = 89(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. DEFL. in (loc) I/defl L/d Vert(LL) 0.07 4-7 >897 360 Vert(CT) -0.08 4-7 >803 240 Horz(CT) -0.00 3 n/a n/a 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint 3 and 77 lb uplift at joint 2. LOAD CASES) Standard PLATES GRIP MT20 2441190 Weight: 20 lb FT=10% Qw�a.a,u. wry,amF:rwssES Ys9rl Jta �a,Ex>.rub.9«ewe.rc,suisrouea:{s,rws.c6wma„-a.<�ai�w�^+�%.m�e �.,abr,�nmm..m9cr9w.ada. a�meyne�Aw.a,..,xa.rm.we v��e�e,P :;.*�6�0.1saa4�'w�. �.w�s,:eee maws.,9owm,.c+, .w.n•w�va�rex,+.e�wm�e..�n..l m.ew.,aor�m ...,,. aanneoeaw vEcxeos o�ae�"umewvM•x�mwawv"v9�pv �l+)b amg eaglarurap'.4! T000�ryT1a1 TM �.m,vram..ae wines .*w�aax.a�an. r.... k..vaup m.✓�aw.. vwie xwe.eeeme.neows�6,s °W.uu..eaae.mietib,a Anmaaa6rw4.P^�94t M1:aA�w m. eeTA¢T{:�pproaer»Tun 'mT bar��sro�vw.awy...w.a�ia�c%sv6teas•.mnsAuy: s 61tv�6 BlA. mi."e„u*eo=.cesaw cmwb. ramz,x�� moyaa. c�mnup. +cma�n'u;usunr^�rmi%sscDewm Mhiiia�esecz..atre�ai�sx�+a�w� iv.cm�vana�o,wn�waaa. n.rwc..Ra,s16 GirwvusrerruAueyrar.spr®'r+9�Ybfivd.Mv,ulsuv[.nn�aW evfi.iMtlGp,mvn MvgYT^}.'kLeYM vVN6�ebwdC69iKbiRWFr9nw 11R>ivo BwTM Cew9✓.vTnvabl�^.^�a'vwwd�a wpuy b Une: 092VA19 ,[iWYz6f bwNr.QSUJnrv4f.'GgagH OSf6A6 Pmf rryssea-Agpalx¢e.p1p¢qim,gAptlFjb,AipIXYRbI.@nl6@,Mtu:y�vsmGM Fv✓Tww. Job Truss Truss Type Qty Ply _ A0280576 WRMSCM1560BlL GE01 Monopitch Supported Gable 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@alhuss.com Run: 8.210 s May 18 2018 Print: 8.210 a May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:24 2019 Page 1 ID:xhtbvZpZyEOpo7r8?qWl ScymLmm MPQJxgkQGy4QyXr3ubkNyQ2oyf4Z SSOKtakyyll6v 2x4 i 1.5.3 II LOADING(psf) SPACING- 2-0-0 CS'. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.08 Vert(LL) We - We 999 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 • BC 0.03 Vert(CT) We - We 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a We BCDL 7.0 Code FBC2017/TP12014 Matdx-P Weight: 9 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-8-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 7112-8-0 (min. 0-1-8) 3 = 7112-8-0 (min. 0-1-8) Max Horz 1 = 39(LC 12) Max Uplift 1 = -13(LC 12) 3 = -33(LC 12) Max Grav 1 = 71(LC 1) 3 = 71(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13 lb uplift at joint 1 and 33 lb uplift at joint 3. LOAD CASE(S) Standard ww.amowsY,..wwae naza+BssBst-sExa.='ry,:.Ereca± TEu+s.aco.mmowswsrmaviivamneaserenri� v✓h<arme: .uw„m=.mxnmrmynu+.aa (m�w,r. BmasyErgvsewrnmeMelkekn'we uM-s case.sem�wa�exoo,<M'.N'm..^vubNea ewausJtren iffimb..ee.u.tms:map,E*xwm�efie.£mX�'E.c��X Neewmmn TB�nP.%sM1+m Jan Boun�eE6mOs :.mmv.,..emew�uaw«a*..m•a�roo,<9�*vma.a.dam...�6+zrmxvm+�,mmoe"4.w..mr,Tr®a.�+»,..vamen*mewm�vw�ar«a,naam. x.,.,r«wa�aWmm.re�manymu. wnwroum r+ammm� casaes'.. mm.e.o-..ow..h�magw.eo-r.. a�nsac w�nm�maac.ce-e.es.wrr+ruma�..•en4e.>ww++mm.xmw.na�n,�..awx.+..:mm>•.eaa..�•wn.=m�am,wao-..ncwar.. a,..,w�.+au .uism�. mre, �arw®.++,via++ebm mm....xma..e»moma+Rssx•ams.b.�+,Aa,.asw s�^e�9* .n+�+�..w.�.asmewcm+evmuasacn wx �..�atrem�•ucw�ne. rrr.e.amme.,.,�xrt•,nwr e.ei.rce. rtxwe ,LLiYdvs.mong•..q: s�tlwrfi+w+�®4THmu���+7^m wn�a.,.va+.,mN:o:.�Fw•mdw�.•�+abeam•anl�wkiM�arE�q.Ta+xrre.e.Tede.�!.�emmmx.wsrmm[,pq...ve�yma:- ea tPK�=a 4TzanmLs624bTh13%pM�+19Mi8Ft kuYTuiim-^�.epm'uimC4m4cumm4M,TTi6RIDiud�K.uLCeT2+mM�aN60.iRM ie.emY, c Dd®: 0&Z3"A18 '.. Job Truss Truss Type Qty Ply A0280577 WRMSCM1560BIL HJ7 Diagonal Hip Girder 3 1 Job Reference (optional) I A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1tmss.cem Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:25 2019 3x4 = 1.5x4 11 3x4 =- LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (100) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vart(LL) � -0.05 6-7 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.53 Vert(CT) -0.10 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.40 Horz(CT) 0.01 5 - n/a n/a BCDL 7.0 Code FBC20171TP120i4 Matrix -MS LUMBER - TOP CHORD 2x4 SP Nc.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 I BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 159/1vlechanical 2 = 442/0-10-6 (min. 0-1-8) 5 = 274/Mechanical Max Hoe 2 — 182(LC 4) Max Uplift 4 = -107(LC 4) 2 = -180(LC 4) 5 = -64(1-C 8) Max Grav 4 = 159(LC 1) 2 = 442(LC 1) 5 = 274(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-1 1=734/174,11-12=-684/191, 3-12=-683/181 BOT CHORD 2-14=266/679,14-15=-266/679, 7-15=266/679, 7-16=-266/679, 6-16=266/679 WEBS 3-6=-717/281 NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL--1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-fi-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 107lb uplift at joint 4, 180 lb uplift at joint 2 and 64 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 Ito down and 90 It, up at 14-9, 77 lb down and 90 lb up at 1-4-9, 36 lb down and 41 lb up at 4-2-8, 36 lb down and 41 lb up at 4-2-8, and 66 Ito down and88 lb up at 7-0-7, and 66 lb down and 88 lb up at 7-0-7 on top chord, and 12lb down and 40 lb up at 14-9, 12 lb down and 40 lb up at 1-4-9, 161b down at 4-2-8, 161b down at 4-2-8, and 30 lb down at 7-0-7, and 30 lb down at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-8=-14 Concentrated Loads (Ib) Vert: 11=57(F=29, B=29) 13=74(F=-37, B=37) 14=46(F=23, B=23) 15=9(F=-4, B=-4)16=-56(F=-28 , B=-28) PLATES GRIP MT20 2441190 Weight: 43 lb FT=10% Q n.,,.ewaS.Y•c.-cins.WrsstsP�ic�w.TB.aus.,eu+xonmYsakraacafsv+cxnrexmw�Brae�-ram.. v.,ge�w F����«w reae es Tr�mo+=a�n...mehmlmeae G Ra+*f EZG�,e�Yeaxvl2am.w w�wcu.�..�n.essawa.Tm.e rw�mn mcb.+c.c�%aue �a.a.am T6obu svaY.ws�w�+m✓�^Bkasw�zn'eze^e^I t+•?dan ^iimreBnev�nart Ja�meowmveszeoG mo�.�QiYy pek,Wutayvwvyivpaer/b MaLayndPa myYTrvgypiJ 1pp Tia.l iMOOHrt�iet bebyem9ifinewla R�ud,md bu ,min �yHuyp 9u.,myiMLtlP{WB� V.Nb WY%E,pmrennG1..�91615 wuead� #^a B�as*GBaW^e m.�aam. xt�iac.amn+4�e`T°Tma'ml���rowumiumoeep r�um.dm.+t�«.eaa�re}Icm ..i,u.xnNY..,a tirv+�+�lnr uslsmae aiw. dAa&ALeG'kz9M'/9tl LmLUINe.M4vRzeHN4 'NB WpeeO{xt Bm'>ra&44n 9viMiB W^% .? Yk�riw�IBG%JBa `+ITA A® ]mGere.tl OWMSz iWile@d N �^,Hvf�4d D.R NN'NNMTrva1M4M.F%'3Mr`-'9✓+®MTNMYM�%7twtsdea9tfisMa�Cad�N hR(:; 1nneYNOy'%T H'al.4MMPIIP°ax�AAO�MiilY 6f� 4Ee➢��aFO'fMB'r16N �T0.'9,'mTrvb SYM1!^6gM�{IMYF�9e �'G 09e: 0fl2Ve01.1B canna[nabmamahrmOnRH.f AxE4'.iPAl6Aiam9vw.-Rzwae=emmemtla.wxin+�Ytrmnm�titimi.sswma:.�r�ww matAz amlivxzc ' Job Truss - Truss Type Oty Ply A0286578 WRMSCM158OBlL HJ7A Diagonal Hip Girder 1 1 J h Reference (ootionan A-i Hoot I russes, Forteterce, FL 34946, design(gaibuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 1341:25 2019 3x4 = 1.5x4 II 3.4 =' LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) -0.05 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.11 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WE 0.42 Horz(CT) 0.01 5 n/a n/a - BCDL 7.0 Code FBC2017/TPI2014 Matrix -MS Weight: 43 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 180/Mechanical 2 = 45310-10-7 (min. 0-1-8) 5 = 301/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -125(LC 4) 2 = -185(LC 4) 5 = -67(LC 9) Max Gmv 4 = 180(LC 1) 2 = 453(LC 1) 5 = 301(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOP CHORD 2-11=-777/214, 11-12=-727/231, 3-12=-7261221 BOTCHORD 2-16=-2881720, 16-17=-2887720, 7-17=-2881720, 7-18=28SU20, 18-19=-2887720, 19-20=-2887720, 6-20=-2887720 WEBS NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=151t; Cat. 11; Ecp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 lost bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 He uplift at joint 4, 185 Ib uplift at joint 2 and 67 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 90 lb up at 1-4-9, 77lb down and 90 He up at 1-4-9, 36 lb down and 41 lb up at 4-2-8, 36 He down and 41 lb up at 4-2-8, 54 lb down and 69 lb up at 5-10-11, and 661b down and 88lb up at 7-0-7, and 76 lb down and 103 lb up at 8-0-2 on top chord, and 12 He down and 40 lb up at 1-4-9, 12 lb down and 40 lb up at 1-4-9, 16 lb down at 4-2-8, 16 lb down at 4-2-8, 24 Ib down at 5-10-11, and 30 lb down at 7-0-7 , and 40 lb down at 8-0-2 on bottom chord. The designiselection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 141==60_54=-14 Concentrated Loads (lb) Veit: 11=57(F=29, B=29) 13=14(F) 14=37(13) 15=-56(F) 16=46(F=23, B=23) 17=9(F=4, B=-4) 18=19(F) 19=-28(B) 20=36(F) Q,4evd�o+s5n�.,e.a.-l.,nw�•tpias�s{-s[ivrn�.�rtw. Taaes.nwimrz,oxbcusmuea�av+en cc rr-EaG�m+mavrym®„pu..�.,.,.wrem.ww«e®i,�0eynrnaWme nog.eno-c r PM�QY®9�+R.rcY"AVMq tdam.uclMewaVaM1M¢Wf Wi➢�.vAA�PM�N ffiul Mv�btMlOpba YLY laeiNPOafR�frG^wIPVGi4"�a'ry£9°�I CwvYoni^Y t➢O tieA JVMa MnW FEB]Po9 pxxcue.aa,.sa.+.w�KAy>.«+rne��bkvP'o d'r�dwsrsm'x•,®mph.e«, Tva ie fain. �m..,o�^'�.�r^s��tiw,.,w6�+r.a,e..pwrrv..a..geaeno®mrawn'n.�UeVMe.. vmaexouwenem�eeYs�su Mns UgOvMamipm:epeg®IUMP.NNscmeddWWOWe,BGG.14N➢dM,peA�eod`nh0.VF'B WSSA mYbNuasdVe'f e�^+x�9M�99.��d+av,LNb�nsdgy�gsFWhMha,Yim.IMY' MS, S, LuiB BIN. NA+59�hMCC�V�aWt=tr1rM�Nm�35M RR vfA6iW W0eP�MdP° g1Y0:iS^iiP=iY�N SMl4t�i.LmNBS=.)➢�tlnlNhLNr9 �Aee,elnewl}abp�'^�84��TPHdHheYbGrty�M4tiq fi.Fvp.ft9�910 �lnw¢NPrtTnin owe�Nswy`��eer.®airv>ed'm�davuwl.wMdaTcm+K4kwwee,,at��e'min.n,mWNdAw!•aMm�.blw4: bGsmm4r�ibB�wBfiF sAbm[T caOIW.iN In,®wYMas6im]Gy.l Ybp,ytCA16AlRa TNas+�-Reim'k�fmnJPwm9msnCTwYAnRiPafiAbC WEPe'HW. PomnhnHIM PN.Tim¢. ¢Tmn q�,tl&Tbd�i:Jl BE4 �2420f9 Job Truss Truss Type Qty Ply r7 A0280579 WRMSCM1560B1L HJ7L Diagonal Hip Girder 1 1 �J.bRiafrence(optionaft A-1 Roof Trusses, Fort Pierce, FL 34946. design@attruss.com T Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Thu Aug 22 13:41:26 2019 Page 1 2x4 = 1AX4 11 JX4 =- LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.11 6-7 >999 36 MMT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.53 Vert(CT) -0.10 6-7 >999 240 BCLL ,0.0 Rep Stress Incr NO WB 0.40 Horz(CT) 0.01 5 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MS Weight: 43 lb FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-M oc pudins. BOTCHORD Rigid ceiling directly applied or 7-6-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 4 = 159/Mechanical 2 = 442/0-10-6 (min. 0-1-8) 5 = 274/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -110(LC 4) 2 = -271(LC 4) 5 = -229(LC 5) Max Grav 4 = 159(LC 1) 2 = 442(LC 1) 5 = 274(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-11=734/451, 11-12=-684/468, 3-12=-683/462 BOT CHORD 2-14=-523/679,14-15=-523/679, 7-15=-523/679, 7-16=523/679, 6-16=-523/679 WEBS 3-6=-717/553 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110lb uplift at joint 4, 271 lb uplift at joint 2 and 229 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 90 lb up at 1-4-9, 77 lb down and 90 lb up at 1-4-9, 36 lb down and 41 lb up at 4-2-8, 36 lb down and 41 lb up at 4-2-8, and 66 It, down and 88 lb up at 7-0-7, and 66 lb down and 88 lb up at 7-0-7 on top chord, and 51 lb down and 40 Ib up at 1-4-9, 51 lb down and 40 to up at 1-4-9, 10 lb down and 40 lb up at 4-2-8, 10 lb down and 40 lb up at 4-2-8, and 29lb down and 71 lb up at 7-0-7, and 29 lb down and 71 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-8=-14 Concentrated Loads (lb) Vert: 11=57(F=29, B=29)13=-74(F=-37, B=37) 14=46(F=23, B=23) 15=-9(F=-4, B=4) 16=-56(F=-28 , B=28) Job Truss Truss Type Oty Ply A028E560 WRMSCM1560B1L J7 Jack -Open 9 1 Job Reference o tional 0.4JUb IVIdy JO ZU Jo VIJFIL. 0.4 AU b IWay 104 U4= I i nu mug L m:rtizi zulu Dead Load DeB. = 118 in LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP ' TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vart(LL) 0.17 4-7 >478 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.64 Vert(CT) -0.20 4-7 >413 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 We n/a BCDL 7.0 Code FBC2017TFP12014 Matrix -MP Weight: 24 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 178/Mechanical 2 = 34910-7-10 (min. 0-1-8) 4 = 70/Mechanical Max Hom 2 = 164(LC 12) Max Uplift 3 = -118(LC 12) 2 = -85(LC 12) Max Grav 3 = 178(LC 1) 2 = 349(LC 1) 4 = 111(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (Ib) or less except when shown. - NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3 is cuss has befo—r-a] a load of-- 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 118 Ib uplift at joint 3 and 85 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type Ory Ply 1� A0280581 WRMSCM1560B1L J7L Jack -Open 5 1. Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, designLcOaltrussAom b Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industnes, Inc. Thu Aug 22 13:41:27 2019 4x4 = 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) 0.18 6-9 >460 360 TCDL 10.0 Lumber DOL 1.25 BC 0.54 Vert(CT) 0.15 6-9 >542 240 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(CT) -0.00 6 n/a n/a BCDL 7.0 Code FBC20171TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-1-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 91/Mechanical 2 = 34910-7-10 (min. 0-1-8) 6 = 159/Mechanical Max Hoa 2 = 164(LC 12) Max Uplift 4 = -69(1-C 12) 2 = -134(LC 9) 6 = -125(LC 9) Max Grav 4 = 91(LC 1) 2 = 349(LC 1) i 6 = 165(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-323/338 BOTCHORD 2-6=-582/283 WEBS 3-6=-307/633 NOTES- 1) Wind: ASCE 7-10;.Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60. plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 69 lb uplift at joint 4,134 lb uplift at joint 2 and 125 lb uplift at joint 6. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 30 lb FT = 10% QPbmAm6VXmk� RpSYaU60EB T'S1.ItsY1 SRN.lEAY4ap{be151'01AEli{6IiYES.A.fI:NNdM.EOGf/sli-im2Vy lc+p Pea'n1^^eMT� rteapa+,g4uTQ{lppiuE4a 6W�14� 6�+d6�lY!!�M°! 9Pa0m P�TOD.p fPmnMnf>ti+wtlOe weEbClTWbbvW0. Nalns QY+bnFM��^�=V F�vR%=d'YBT.F'"m)PrW mr�TOO,iar9iMdan: dvG�Wsame�lwB�w�eG�uRiBn��dPs,MbTwa4ptlymtl+YOQadv"udv (a®9T>�'^^0. JaMB6udID i'E6t809 'A1nk Xouss En9lnttf�MCP91615 aepG�� JW.%.ThaOs"s++®e'PBm4 �3WMtinn *WaNifWw.l Ra '��0'd44 -0w.WMaJaylhS°gCom vSb9✓MN 4TMFinaWtllb6t48aV4TVIbyl"6 Nb sAlPlF bn4W^ti NMI➢SYbTrffitla4mW'R N,iYe�WO e�Y ".u.rNM11C'W abYbA.mf�plh Y510WIa 6 .^'vi A=9�6TGRaQN/OWCW'PParF➢Pana rNoWaMBT00IDMY.epeLiWmdpuCtiv9,A baBudbniiaNlr�,r£J^N4,bn�mABG69G��MaWT%YW 68CPN`,eMenEtlfw'peM!m9mWWTGK2ERel6i2`{m[i1`AT^!?m: AVAe(LZT,w64GiM.6A�➢`�S^iPOM.T!4yafMN'�nf:4WeY'cT.B�vlsdO&W.OY6 CON�6 MPbC���^�Th!ST�St4yb RPerw.RNBK WaaC.vCmnM?W W"mhvnMTM 6u9SN�4nHwirv4 Mr.?`-TN�A�9r FI��'.M fll ytlYaa]VrmmSah6TbiT.R4f�gaY.iQ(A161r WNT,m�,-ALO�+hlmYbmitivlVlN:Fr: �APN.ONSwwi0wwr 9.HMOmpxuY,mYlfigRTNua' 10 Om: 062Y2010 Job Truss Truss Type Cry Ply A0286582 WRMSCM1560BlL JE T Jack -Open 6 1 Job Reference (optional) ,I KocT I russes, ron rlercc, rL Sg , oesigntgallmss.com i 3x4 = muma2lus MayldzUld Pnnt:d.ziusmayld2Uld MIIeK 1.p4n 4 Inc. I nU m A I� 13:41:262U19 Pagel oaf2xDVoS2Jxontjyll6r Dead Load Defl. =1/a in LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Ve 1(LL) 0.22 6 >384 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.23 6 >359 240 BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) 0.07 5 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MR Weight: 27 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP 2400F 2.0E BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 166IMechanical 2 = 36010-7-10 (min. 0-1-8) 5 = 87/Mechanical Max Horz 2 = 164(LC 12) Max Uplift 4 = -105(LC 12) 2 = -78(LC 12) 5 = -7(LC 12) Max Grav 4 = 166(LC 1) 2 = 360(LC 1) 5 = 118(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 —2)Thistruss has be�esigned fora 10A psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105lb uplift at joint 4, 78 lb uplift at joint 2 and 7 lb uplift at joint 5. LOAD CASE(5) Standard Job Truss Truss Type Qty Ply 1; A0280583 WRMSCM1560BlL TO6 Common 4 1 Job Reference(optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1 Wss.com Run: 8.210 s May 18 2018 Print: 8.210 s p - ID:ld_0OXyyT61B 4.8 = 6.00 F12 2018 MiTek Industries, Inc. Thu Aug 22 13:41:29 2019 i.Sx4 II 3x8 = 1.5x4 II 3x8 = 1.24 9-0 M1-08 7-9-12 ]-774 H 6-74 P 12 � LOADING(psf) SPACING- 2-M CSI. DEFL. in (too) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.24 Vert(LL) 0.09 9-10 >915 360 MT20 244I190 TCDL 10.0 Lumber DOL 1.25 BC 0.38 Vert(CT) 0.07 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 9 Na n/a BCDL 7.0 Code FBC20171FP12014 Matrix -MS Weight: 69 lb FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 41510-3-8 (min. 0-1-8) 9 = 415/0-3-8 (min. 0-1-8) Max Hom 10 = 147(LC 11) Max Uplift 10 = -194(LC 8) 9 = -129(LC 13) Max Grav 10 = 415(LC 1) 9 = 415(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-951251, 4-5=-951251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 194lb uplift at joint 10 and 129 lb uplift at joint 9. LOAD CASE(S) Standard Job Tmss Truss Type Oty Ply A028a584 WRMSCM1560BlL TO6A Common 1 1 LbRefere.m (optional) ..-� ..wi uwaca, n �.=�uc, r� waw, uvayn ,Lain uuv.ww 4x, nun: o.<m s may 4x8 = 6.00 12 3 o.ziusmayro<uiumuexmausmes,mc. fnu Hugz<1s:ai:[uzuiv h 1.5x4 II 3x8 = 1.5x4 II Us = 1-24 9da 1 M 1-08 11 7-&12 8 8-7.8 NA-2 0. 12 U -08 Plate Offsets (X Y)-- 14:0-0-00-0-01 t5:0-0-00-0-01 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) 0.09 7-8 >900 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.37 Vert(CT) 0.07 7-8 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 7 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MS Weight: 65 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlms, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MTek recommends that Stabilizers and required cross. bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = 322/0-3-8 (min. 0-1-8) 7 = 32210-3-8 (min. 0-1-8) Max Horz 8 = 135(LC 11) Max Uplift 8 = -98(LC 9) 7 = -155(LC 9) Max Gmv 8 = 322(LC 1) 7 = 322(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-129/283, 3-4=-129/283 WEBS 2-8=-208/305,4-7=-208/304 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp, B; EncL, GCpi=0.18; MWFRS (envelope) and-C-LF enor(2 zone; can " evle—r left a-ndrig1t-- exposed ; end vertical left and right exposed; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 8 and 155 lb uplift at joint 7. LOAD CASE(S) Standard gnnap�;q ara, aos ttuwsss i"ssltEal EsrY�wremas.emf nuwsarsrdasw�cau+ea•�nciaxmuocaz-tt�'+s....v+^yaa:w e��«e.m „m�ea7,"® &sraYi'r �"q'.,a4naoemeuim4 WensaaNNxxww wTm.o.a7n9,mm�nW h-+WawaeW4m'�fo�w�,ase4amo�^e+e��`afasga>aYr�^v^�leT^a.im ^Yt� .ieretaouumvE smos ¢�r�m n.ma�esb.xmgmmvp �Pa^a'aYYKeehvTd e*sLr aq,..m}.wm.ryne^4amJfe-LrnadFs� �*m.nuE•ee^1��+�a'+a<x.a.....a W>�.h<M'� �av�.v O^v mne'eve.maag�mfmm'eWi.Q ougme,AWwm<W MAC&si96 eale mAl%.}.A�NG.vNN11'e RNaNfeYaWvsmna9.a*: 4 M+.uT ^e'aeRiN.are WTub Xouu EMtrseMOG916t5 NBn rvAW3♦>eVndarl Cuarme F9mnssl m.�.�As Nwme;6^eesd i'9A8a&. 6nYCwa=NSM1VM�'.an%BSGO Ce��M'IPiNaEBeAe�>a�9da5ensd MiTMie^Y to ee4w'SW MS1 S1I,tle Blutl. wmrdear.wnwyn.6ps�-.Y Enpeivm4ina mMee�eq mYaic6MpCaaeGwab3.^.,o-wanwreea..mTn�aNdomm+ard..elwSwME^cbo.m�Ht ai BWAV�a �sy A2a� kalvsbl'»gMtl. aF,u.Rs1me 'tmaa-sa+u�...:mr..anmr.�e�,pas:msnaR+manss:.-nitro.ao®.mvaw^axnu:w.n.a+waw..,mm a.eQ•®.mwsrma�un:` PY 5""e'w FA " ose. aerzsrzols Job Truss Truss Type City Ply '! A0280585 WRMSCM1560BIL T06SGE Common Structural Gable 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.cem fs LOADING(psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 7.0 Code FBC2017/fP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pur ins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 41510-3-8 (min. 0-1-8) 9 = 415/0-3-8 (min. 0-1-8) Max Horz 10 = 147(LC 11) Max Uplift 10 = -194(LC 8) 9 = -129(LC 13) Max Grav 10 = 415(LC 1) 9 = 415(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 3-0=-95/251, 4-5=-95/251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=i 60mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MTek 4x8 = 6.00 1-2 3.8 = 3x8 = 2< 9-0e 108 1-e-12 1-11-8 1-0a H sl-s a 1z� CSI. DEFL in (loc) Well Ud TC 0.24 Vert(LL) 0.09 9-10 >915 360 BC 0.38 Vert(CT) 0.07 9-10 >999 240 WB 0.09 Horz(CT) 0.00 9 n/a n/a Matrix -MS 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/fPl 1. 4)All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 194 lb uplift at joint 10 and 129 lb uplift at joint 9. LOAD CASE(S) Standard Inc. Thu Auq 2213:41:30 2019 PLATES GRIP MT20 244/190 Weight: 84 lb FT=10% Job Truss Truss Type Oty Ply A0286586 WRMSCM1560BIL VM08 Valley 1 i Job Reference o tional 1. rtoot 1 tosses, ton ne w, rL 09 , ee51gnLwaleYss.com KUn: a.41U S May 10 ZUla rnnl: 0.21U s May la 2Ulb M11 eK MOUSmeS, Inc. I nU AUg ZZ 1J:41:JU ZU19 3x4 = 9 3x4 = 3 4 2x4 1.5x4 II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deg Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) We - n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.22 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 4 n/a n/a BCDL 7.0 Code FBC2017frP12014 Matdx-R Weight: 20 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-OA oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. fib/size) 1 = 193/5-11-8 (min. 0-1-8) 4 = 19315-11-8 (min. 0-1-8) Max Horz 1 = 70(LC 12) Max Uplift 1 = -46(LC 12) 4 = -58(LC 9) Max Grev 1 = 193(LC 1) 4 = 193(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. - 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)-Provide adequate drainage to prevent water pon ing. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-U wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 461b uplift at joint 1 and 58lb uplift at joint 4. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A0280587 WRMSCM156081L VM10 Valley 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:31 2019 Pagel rxID:Id_00XyyT61Bi_TXoliwHHzefvK-DiK3nKl7mQqfmO2BzsEN9RCCin1Vi8FU7v3RU2y1I6o 8-0-0 8-0-0 4 P O 2x4 i 1.5x4 II 1.5x4 II 4 1.5%4 II " LOADING(psf) SPACING- 2-2 CSI. DEFL. in (loc) I/defi Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) n/a - n/a 999 TCDL 10.0 Lumber DOL 1.25 BC 0.11 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep SVess Incr YES WS 0.12 Horz(CT) 0.00 n/a n/a BCDL 7.0 Code FBC20171TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 89/7-11-8 (min. 0-1-8) 4 = 111/7-11-8 (min. 0-1-8) 5 = 33577-11-8 (min. 0-1-8) Max Horz 1 = 147(LC 12) Max Uplift 4 = -51(1-C 12) 5 = -155(LC 12) Max Grav 1 = 89(LC 1) 4 = 111(LC 1) 5 = 335(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 1-2=-275/117 WEBS 2-5=-272/418 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF, h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 4 and 155 lb uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 31 lb FT=10% Truss Type Oty PlyA028(1588 ��M—S—CM1560BiL VM12 Valley 1 1 Job Referenceo tiona0 A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1buss.com 2x4 i Run: 8.210 s May 18 2018 Pnnt: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:31 2019 Page 1 ID:Id_OOXyyT61Bi_TXoljvHHzefvK-DiK3nK17mOgfmOZBz EN9RCBJnOZi7?U?v3RU2yll6o 5 1.5x4 II 1.5x4 II 3 4 1.5x4 II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 V t(LL) n/a - n/a 999 TCDL 10.0 Lumber DOL 1.25 BC 0.17 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 Horz(CT) 0.00 4 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 MatnxS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0.oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 12419-11-8 (min. 0-1-8) 4 = 14519-11-8 (min. 0-1-8) 5 = 414/9-11-8 (min. 0-1-8) Max Hom 1 = 188(LC 12) Max Uplift 4 = -67(LC 12) 5 = -190(LC 12) Max Grav 1 = 124(LC 1) 4 = 145(LC 1) 5 = 414(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-314/128 WEBS 25=-330/474 NOTES- 1) Wind: ASCE 7-10; Vasd=124mph; TCDI h=1 and C G Extenor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load noncancurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 67 lb uplift at joint 4 and 190 lb uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 40 lb FT=10% Job Truss Truss Type Ory Ply T A0280589 WRMSCM1560BlL VM14 Valley 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.com It Run: 8.210 s May 18 2018 Prim: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Aug 22 13:41:32 2019 Page 1 ID:ld OOXyyT61Bi_TXoljwHHzefvK-hutR?gmlXjzWOA8OXZIcheIK4AKnRZvdEZp?OUyll6n 12-0-0 12-M 1.5x4 II 3 3x4 i 5 6 4 1.5x4 II 1.5x4 II LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC OA4 Vert(LL) n/a - Na 999 TCDL 10.0 Lumber DOL 1.25 BC 0.30 Vert(CT) n/a. - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.16 Horz(CT) 0.00 4 We n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix-S LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 1 = 153/11-11-8 (min. 0-1-8) 4 = 174/11-11-8 (min.0-1-8) 5 = 503111-11-8 (min. 0-1-8) Max Horz 1 = 229(LC 12) Max Uplift 4 = -81(LC 12) 5 = -232(LC 12) Max Grav 1 = 153(LC 1) 4 = 230(LC 19) 5 = 503(LC 1) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=-363/149 WEBS 2-5=-402/545 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 Ib uplift at joint 4 and 232 lb uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 48111 FT=10% JUNE 20, 2019 1 TYPICAL HIP / KING JACK CONNECTION I STDTL01 t A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. Attach King Jack w/ (3) 16d Toe ,Nails @ TC & BC Attach End Jack's I Attach Corner Jack's w/ (4) 16d Toe Nails @ TC w/ (2) 16d Toe Nails @ TC & & (3) 16d Toe Nails @ BC N- (Typ) 0 ttach Corne / (2) 16d T @ TC & BC J.rc�9Mt�PE 9M� tMde XWse BpYnfrLq W 91815 ft9 RUN. 19,0 .. Yu 012YAt9 FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 3494 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD I' - 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 24' O.C. 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING V/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. 19:I1`1.3" CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE.TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRACE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WINO SPEEDS 120 MPH (ASCE 7-98, 02, 05), 159 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (J31' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEOS•GREATER 120 MPH (ASCE 7-99, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (13l'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUST MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED / STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE TRUSS / ---I—ORAL TRUSS _�U AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. DULY 17, 2017 STANDARD PIGGYBACK TRUSS ,l6 ,LILIl ..TI. &I -All 1 STDTL04 THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VALID FOR ONE PLYTRUSSES SPACED 24.O.C. OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' OZJ A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTIUSE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5- X 0.099-) NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. .ramaani.ncevms WMN XWYEipNHNp W 91616 MSINLuge B'W. p.PWa.R91NB am BYtY1010 JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED 1 STDTL05 u A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A P 12 SEE DETAIL'A' BELOW (TYP.) GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X0.131'=10d 2. WOOD SCREW= 4.5'WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NOS -01. 7. VALLEY STUD SPACING NOT TO EXCEED 48'O.C. BASETRUSSES VALLEY TRUSS (TYPICAL) ATTACH 2X4 CONTINUOUS k2 SYP TO THE ROOF W/ TWO USP WS45 (1/4' X 4.5) WOOD SCREWS INTO EACH BASE TRUSS. TRUSS CRITERIA: GABLE END, COMMON TRUSS, OR GIRDER TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. Jua19MI�PE YNJB wxb xous. xymren�a w 31615 FL Pbm, GL.49,8 OM: p42yM19 FEBRUARY 5, 2018 TRUSSED VALLEY SET DETAIL (`�11911111*I6 A-1 ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-0091010 SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS ATTACH 2X4 CONTINUOUS 42 SYP TO THE ROOF W/TWO USP WS3 (1/4- X 3-) WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A (NO SHEATHING) N.T.S. GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10d 2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM)AND SECURE PER DETAIL 'A'. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS: 5. BASE TRUSS SHALL BE DESIGNED WITH A PURMN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NOS -01. 7. VALLEY STUD SPACING NOT TO EXCEED 48'O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24- O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. J.B B. PE 62CW K1nb Neuu FryMMnO � MIS �A51 fi Wtle BM. D.: RJIMe on.:omarsme JULY 17, 2017 1 I\LJJJLL.' Vl1LL_L 1 VlL I LJL_ 1n1L (HIGH WIND VELOCITY) STDTL07 u A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7 WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24' O.C. (BASE AND VP SUPPORTING TRUSSES DIRECTLY UNL�.. ., DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF Z -10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPFS SPECIES LUMBER NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6/12 PITCH NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) e.irawu��ssms vnoa �E•eme.noo usims ws+s wo. are, n.a�r.,as.su M[ 6VtNOt9 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 3494 772-409.1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/Uld NAILS, 6' D.C. VER' STU[ SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUDVBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED G' OZ. (2) IDd NAILS INTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF 42L HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - IDd NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS ** (4) Ed NAILS MINIMUM, 3X4= PLYWOOD SHEATHING TO 2X4 STO SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER va REFER TO SECTION A -A TO SECTION B-B 24' MAX.►I NOTE: / 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. / 2- CONNECTION BETWEEN BOTTOM CHORD OF GABLE ENO TRUSS AND WALL TO 12' MAX: BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF lOd NAILS SPACED S' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4' - 0' D.C. S. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 15d NAILS SPACED -S' O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) IDd NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7. GABLE STUD DEFLECTION MEETS OR EXCEEEOS L/240. B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE BRACE AT 1/3 S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPEPOINTS TRUSSES. IF NEEDED 10. IDd AND 16d NAILS ARE 0.13l'X3.0- AND 0131'X35' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING VITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP#31STUD 12'0.C. 3-&10 5&ll 6&11 11.1-13 2X4SP#31STUD 16'0.C. 3-3-10 4-9-12 6&11 9.10.15 2X4SP931STUD 24'0.C. 2-8-6 3.11-3 5-4-12 8-1-2 2X4 SP #2 12'0.C. 3-10.15 5&l1 6&ll 11.8-14 2X4 SP#2 16'0.C. 3&11 4.9-12 6&ll 10-8-0 2X4 SP#2 24'O.C. 3-14 3-11.3 6.2-9 9.3-13 DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH IDd NAILS 6. O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. ROOF SHEATHING (2) - SOd NAILS 'TRUSSES 0 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' D.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - IOd NAILS. HORIZONTAL BRACE (SEE SECTION A -A) ENO WALL MEAN ROOF HEIGHT= 30 FEET )SURE B OR C :7.10 190MPH ITION OF LOAD INCREASE: 1.60 FEBRUARY 17, 2017 I WITH 2X BRACE ONLY - I STDTL09 NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6- O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T—BRACE / ]—BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2XB 2XB T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 1—BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2XB 1—BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB NAILS WEB I -BRACE T-BRACE SECTION OETAILS Klnb X W y 6NNeeMi CA 51815 451611�u5e BIW. R PWu.F�919N D6d O42YA18 FEBRUARY17,2017 1 LATERAL BRACING RECOMMENDATIONS I STDTL10 r TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. ILI C, NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY X1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772-09-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d TO TOP CHORD NAILS (0131' X 3') C\NAILS (0131' X 3'). ATTACH TO VERTICAL \ r NAILS WITH (3) - NAILS (0131' X 3') BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORE] NAILS (0131' X 30 ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0131' X 3') IN EACH CHORD , ATTACH TO VERTICAL SCAB WITH f3) - IDd NAILS (0131' X 3') TRUSS 2X6 4' - 0' WALL STRONGBACK r (TYPICAL SPLICE) � (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA1 INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - D' AND FASTEN WITH (12) - 10d NAILS (0131' X 39 STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) NM4 Hn�iva�E+PE e ft1 'F 96W, Pmu. R 91910 DM W51R919 FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTL11 A-1 ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NOTES: 1. TDE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 450 WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 z .135 93.5 85.6 74.2 72.6 63.4 0 J in .162 108.8 99.6 86.4 84.5 73.8 ri .128 74.2 67.9 5B.9 57.6 50.3 z p .131 75.9 69.5 60.3 59.0 51.1 N .148 81.4 74.5 64.6 63.2 52.5 1 Mi VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 845 (LB/NAIL) X LAS (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30' TO 60' THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW ... (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.000 FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDR12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP DF HF SPF SPF-S LD .131 59 46 32 30 20 Z O J .135 60 48 33 30 20 .162 72 58 39 37 25 J F (, .128 54 42 26 27 19 0Z Z .131 55 43 29 28 19 LU .148 62 48 34 31 21 J in J N Q M Z .120 51 39 27 26 17 0 Z .128 49 38 26 25 17 0 .131 51 39 27 26 17 0 .148 57 44 31 28 20 M NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 133: 3 (NAILS) X 37 (LB/NAIL) X 133 COOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO FOR WIND DOL OF 1.60. 3 (NAILS) X 37 (LB/NAIL) X 1.GD IDOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. *as USE (3) TOE -NAILS ON 2X4 BEARING WALL *of USE (4) TOE -NAILS ON 2X5 BEARING WALL NEAR SIDE FAR S1 IE TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I STDTL13 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 1.0 A 14 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d TRUSS 2411 o.c. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES (4) 12d MAX 30" (21-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 Jw BL m mm N1We Hwv Bg rlryL/.]1815 uStflLu@W RGun,RN91] Db: OZtaTI] FEBRUARY 17, ZOi7 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 iY TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 3D' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 Q. 3657 5485 3346 5019 2829 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2XG) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C Ilk • lOd NAILS NEAR SIDE + IOd NAILS FAR SIDE THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT DO NOT USE REPAIR FOR JOINT SPLICES NOTES: L THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR ODES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. -9 TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34945 772-409.1010 TRUSS CRITERIA: LOADING: 40-1D-D-10 DURATION FACTOR: 115 SPACING: 24' D.C. TOP CHORD: 2X4 OR 2XG PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X_SCAS (MINIMUM S2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (148' DIA. X 3') SPACED S' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS. DETAIL TO BE. USED ONLY WITK-TRUSSES-(SPANS-LESS THAN -4D9-SPACED 24' D.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. 11 Lumber design values are in accordance with ANSI7TPI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job WRMSCM1560B1L ,No. Seal # Truss Name Date 37 A0280583 T06 8/22/19 38 A0280584 T06A 8/22119 39 A0280585 T06SGE 8122119 40 A0280586 VM08 8/22119 41 A0280587 VM10 8/22119 42 A0280588 VM12 8/22/19 43 A0280589 VM14 8122/19 44 STDL01 STD. DETAIL 8122/19 45 STDL02 STD. DETAIL 8122119 46 STDL03 STD. DETAIL 8/22119 47 STDL04 STD. DETAIL 8122119 48 STDL05 STD. DETAIL 8/22/19 49 STDL06 STD. DETAIL 8/22/19 50 STDL07 STD. DETAIL 8/22119 51 STDL08 STD. DETAIL 8/22/19 52 STDL09 STD. DETAIL 8/22119 53 STDL10 STD. DETAIL 8/22/19 54 STDL11 STD. DETAIL 8/22/19 55 STDL12 STD. DETAIL 8/22/19 56 STDL13 STD. DETAIL 8122/19 57 STDL14 STD. DETAIL 8/22119 58 STDL15 STD. DETAIL 8122119 59 STDL16 STD. DETAIL 8/22/19 moie�u»awui.�ewsiav Page 2 of 2 0. Rsm.R9°9°B Oal¢ M/IIRM9