Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE\°k \,�_ _ 03gr7 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance' Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE STERLING - Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCE, FL, Owner: `Q 1z Permit Number: Jurisdiction: st. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types.(1442.0 sgft.) Insulation .Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft- b. Frame -Wood, Adjacent. R=11.0 192.00 ft' 3.Number of units, if multiple family 1 c. N/A R= f , 4. Number of Bedrooms 2 d, N/A R= ft° 5. Is this a worst case? Yes 10. Ceiling Types (1504.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (ft� 1474 b. Knee Wall (Vented) R=19.0 30.00 ft' Conditioned floor area below grade ff) 0 c. N/A R= ft' 11. Ducts , R W Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor. - SgI,.U=1.04 101.25 ft. _ SHGC: SHGC=0.29 b. U-Factor: SgI, U=1.11 40.00 ftz 12. Cooling systems kBtulhr Efficiency .SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15:00 c. U-Factor: N/A SHGC: 13. Heating systems kBtulhr - Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14.. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473:50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= it, 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.97 PASS Total Baseline Loads: 48.55 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans andi1 by S)p �'8p specifications covered this Code. calculation indicates compliance with the Florida Energy Code. fir um r t0 PREPARED BY[ Before construction is completed tL9�`'1/ DATE: 1-! this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 4 with the Florida Energy Code.Gp� OWNER/ BUILDING OFFICIAL: DATE: \ DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enc7os'iire�4tQ1Ree as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.-1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R4Rp4 EWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ia1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) ComplantSrofttwae� Compliant _ Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No. - Yes Yes 3 M. BATH 56 448 No 0 1. Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360- No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREATIDINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 — 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 _ 0 .. 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 it 0 203.5 ft2 — 0 1 .0 78Iab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 — 0 1 0 1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY E ft 0 42 ft' s 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light N 0.6 No 0.9 No A 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood- _ 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood " 3 Under Attic (Vented) M.BATH 30 - Blown 56 IF 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft- 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft- 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.'1 Wood 9 Under Attic (Vented) GREATIDINING 30 Blown 488 ft' 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below ri In Aran tia 1 NE=>SW Exterior Concrete Block - Int InstBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 NW=>SE Exterior Concrete Block- Int lnsuBEDROOM 4.1 14 0 8 0 112.0 fl= 0 0 0.4 0 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 ft' 0 - 0 0.4 0 5 NE=>SW Exterior Concrete Block - Int Insul - BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block- Int lnsG EDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- Int InsEEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsHIEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 SW=>NE Exterior Concrete Block- Int InsBEDROOM 2 -4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 _ 11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int InsddREAT/DIN[ 4.1 26 - 0 8 0 208.0 ft' 0 0 0.4- 0 _14 NW=>SE Exterior Concrete Block- Int lnstOREATIDINI 4.1 20 0 8 0 166.0 ft- - 0 0 0.4 0 1/812020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent it n�t To Wall lyps_r:cting Space Cavity Width Height Sheathing FramSolar Below _15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.Oft2 0.23 0.4 0 DOORS # Ornt Door Type Space Stones U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered.orientation => changed to Worst Case. Wall V # Onnt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-ESingle Yes 1.04 0.29 N 32.9 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Yes 1.04 0.29 N 6.9 ft2 1 It 0 in 1 ft 5 in None Yes 1.04 0.29 N 24.0 ft2 6 It 0 in 1 ft 5 in None Yes 1.04 0.29 N 37.5 ft2 1 ft 0 in 1 ft 5 in None Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wali Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl. HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM #. System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg - None 1/8/2020 4:48 PM EnergyGaugeO USA 6.0.02 (Rev. t) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft? Attic 65 ft2 . Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre Thermosta��t:]]Y Crreiling Fans: Heating pU Jan [X) Feb r[�'] Mar ANov [X] Jey un t ]Jul �X [ Aug [X] [ ]Sep [ ] r[X'l OctL.l i Dec Venting [ ]Jan [[ 11. Feb tX] Mar Lxl pr [ May l l Jun [) Jul [ Aug (]Sep l X[ ]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 - 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) - AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 65 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68' 68 68 68 66 66 - MASS Mass Type Area Thickness Furniture Fraction Space. - Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. 112 ft 0.3 WIC Default(81bs/sq.ft. - ft2 ft 0.3 M. BATH Default(8 lbslsq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbslsq.ft. _ ft2 ft 0.3 ENTRY Default(81bs/sq.fL ft2 ft 0.3 LAUNDRY - Default 81bs/s .ft. ft2. ft 0.3 GREATIDINING -. 1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FtaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier In any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottomto the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor insulation, Insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind ninina and wirino Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers, shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I dd't' a. n a I ion, mspectlon of log walls shall be m accordance with the provisions of ]CC-400. 1/8/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location Attic 4. Number of bedrooms 4. 2 5. Is this a worst case? (yes/no) 5. Yes 6. Conditioned floor area (sq. ft.) 6. 1474 7. Windows, type and area a) U-fador:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 c) Area 7c. 141.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a)Slab-on-grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight Walls d) Radiant barrier installed 10A1. 10A2. 4.1 10131. 11.0 10132. 13. Cooling system: Capacity 34.8 a) Split system . SEER ' 15.0 b) Single package SEER c) Groundiwater source SEERICOP d) Room unitIPTAC EER e) Other 14. Heating system: Capacity ' 34.8 a) Split system heat pump HSPF . 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tankEF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a 30.0 b)Crossventilation No 11 b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL display card will be completed based on instabd code compliant features. Builder Signature: Date: -Address of New Home: THE STERLING\Q� City/FL Zip: FT. PIERCE. FL 1/812020 4:49:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY SL' City, State, Zip: FT. PIER FL , Permit Number: AIV, A� Owner: `� �� Design Location: FL, Fort Pierce Jurisdiction:Q} ay County: St. Lucie (Florida Climate Y6'k&%e C 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned Floor area below grade (R2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Coaling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.03 PASS Total Baseline Loads: 48.47 1 hereby certify that the plans and specifications covered by Review of the plans and S7a?A this calculation are in compliance with the Florida Energy specifications covered by this �FgBE Code. calculation indicates compliance with the Florida Energy Code. i=•';. PREPAREDLY: !t heedilG �0 D. -tZ j� Before construction is completed this building will be inspected for r compliance with Section 553.908 t e I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. �'Op WEgfb� OWNER/A ENT' BUILDING OFFICIAL: DATE: `� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this prolect requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2IjE FILE E2). D r-O" CODE ��PIDJANCE ST. L� COUN Be-)OC 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC t ft 0 63 ft' 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' __ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 9/11/2019 12:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft' _- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 fN 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft- 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block - Ext Ins@EDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Ext InsiSEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Ext Ind3EDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext Ind3ffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext IndBEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext Insd1AUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Ext InaGREAT/DINT 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Ext In98REAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. _ / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Law-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 N 32.9 ft2 1 It 0 in 1 ft 5 in 1.04 0.29 N 6.9 ft' 1 It 0 in 1 ft 5 in 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 It 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS _ / — Supply -- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft- Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: ,Y Heating Jan [)() Feb Mar [ [ Apr May (X r Jun [ ] [X] Jul �X [ Aug [ ] IX] Sep � Oct Nov[rX,]Nov[X�] Dec Venting [ 1 Jan [ ] Feb l l X Mar IX l [ [ Jun I) Jul I Aug [ 1 Sep [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. W ft 0.3 M. BATH Default(8 lbs/sq.ft. fts ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner: Jurisdiction: U w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dro ed ceiling/soffit Y dropped 9 the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Kneewalls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors I skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall behind piping and wiring Showerltub The air barrier installed at exterior walls adjacent to showers and _Qxtend Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/11/2019 12:29 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit l ld. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �-- Date: Address of New Home: THE STERLING `U \ A_zcity/FL Zip: FT. PIERCE, FL 3 '-\ r'S 1 9/11/2019 12:29:36 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 - wrightsoft° Project Summary Entire House QUICK CALCS, INC. For. WYNNE DEVELOPMENT THE STERL G, FT. PIERCE, FL Notes: \ Nz� ���� Design Information Weather. Fort Pierce, FL, US Winter Design Conditions SCANNED '0': : Y Summer Design Conditions Outside db 42 OF Outside db Inside db 70 OF Inside db DesignTD 28 OF DesignTD Daily range Relative humidity Moisture difference Heating Summary Structure 18188 Btuh Ducts 5664 Btuh Central vent (0 dm) 0 Btuh (none) Humidification 0 Btuh Egpupmentload 23842 BBtuh Infiltration 90 OF 75 OF 1L °F- •50 % 61 gr4b Sensible Cooling Equipment`Load Sizing Structure . 17877 Btuh . �30 Central:vent(0cfrn) Btuh (none) Blower 0 Btuh Use manufacturers data n RaW, inggmultipplier 0.95 Equipmenisensitile.load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Bluth Duds 2319. Btuh Central vent (O din) 0 Btuh Area(ft� Heatingg Co I' (none)' 1474 1474 Equipment latent load 5277 Bluh Volume(fe) 12227 12227 Airchangeslhour 0.45 0.23 Equipment Total Load (Sen+Lat) 30370 Btuh Equiv.AVF (cim) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC636MO30 AHRI ref 7914585 Efficiency 8.5 HSPF Heating input Heating output 34600. Btuh@47eF Temperature rise 27 OF Actual air flow 1160 din Airflowfactor 0.049 cfn/Bhrh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 33 OF Badcup: Input=7kW, Output= 23009 Btuh, 100 AFUE meetall -►I& W etcoft" w....w•.r.r RIg14SIIIeaPldtiversa1201979.0.07 RSWS101 ...e r4S%WdghtoftWAMWYNNE-TESTERLWGnp Calc=MJS FrortDoortacesN Cooling Equipment Summary Carrier CARRIERAIR CONDITIONING 26HBC536MO30 FX4DN((B,F)037 ref 7914585' .ncy 12.0 EER,15 SEER 24360 Btuh 10440 Btuh 34800 Btuh 1160 cfm 0.044 cfinlBfuh 0.50 in H2O 0.83 of Manual J 8th Ed. 2019Sep-17 00:31:10 Pagel wrightsoW Right -A) Worksheet Job: Entire House Data: QUICK CALGS, INC. By. 317ST.WCIELN.,FT.PIERCE,FL34946Phme:772-0e6-6799F=7724668796 Emil; OUICKCALCS@}WLCOM 1 Room name Entna House MASTER BEDROOM 2 h 1562 ft 520 ft 3 Room ight 83 ft d 8.0 ft heatlmol 4. Room dimensions 1.0 x. 329.0 ft 5 Roomapaa 14735 1F 329.0 tl Ty Construction U-value Or HTM Area (M Load Area (W) Load number (BWhIRz°F). WtVtt (B) or perimeter (I(BWh) or pedme�r (19 (BLh) Heat Cool Gross N/PIS Heat Cool Gmss NIPS Heat Cool 6 Wi 13PA06s '0.143 ne ..400 2.55 479 442 '-'1766 �.. 1124 80 ... 80 L—G1Aciomw,, ,. ,: 1270 "0.143 na"_"'3556 ;70:43 38 -:::. 0 `1344 _: °j2662 •0'.:, - 0'- 0.3i W 13A4as 4.00 255 128 83 331 210 0 0 0 1Actom 1270 se 3556 34.77 24 24 648 829 0 0 0 11 11D0 0.390 se 10.92 1121 n » Zan ven n - - 0.143 `si ..,=400 _max. " :..,. .84 ,. 34 •. '.. �136 ' 86' 0, 0 `='- 0 W L—G 13A4as 1Aclom 0.143 SW 400 255 360 353 1414 - -899 , 224 MAI " 897 .570 1270 sv 35-% 4291 7 5 247 298 0 0 0 0 134400s 0.143 W ' '4A0 ; 2.58 290 s867 551 112 �' 79 318 ' 202 ' ' 1Ac1om ;4AS2om 1270 rrv✓,.4524: i 33 .. 0 '-1162 ,,1478 33 0 `: 1162 ,, °1478 ,,. J„ v ;A.770 ., nw- ....i21.56 ..27.54 _ 41 - 0 .. "_.: 880 v s `-1124 '0 -. -z 0 •r 10 P 12C-0sM 0.091 128 162 192 489 246 0 ,0..,; 0 0 0 0.032 -255 .0.90 ,",2.32 ': '1474 1474. ;A320 ; • :•3419 329 =z:' 329 :_: • 295 : 163 F -, 22A-ml 0.989 _- 2749 0.00 1474 1% 0 329 52 1440 . 0 6 o)AEDe=urson ice nnn 12 a) Infillraton 1 2822 773 909 249 b) Roomven47atton 0 0 1 1 0 0 13 Internal9aim Omupants@ 230 5 1150 2 460 APp6anoeslolher 2000 0 SubWal Qines6trr13) 18188 17877 5341 4606 Le edemalload 0 0 0 0 Lesstranster 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Ductloads 31% 48% 5654 8536 31% 48PA 16601 2199 Total room load 23B42 26413 7001 6805 Alrrequired(rtrn) 1160 1160 341 299 Calculations approved bvACCAto meetall requirements of Manual J Sth Ed c ' �=:T�. $..~,.�° _ 2019-Sep-17 W31:11 RE,TFE STERUNGAPversal Calc9.0.07 FrontD o Page _oomeNs\Wdgf/soRFivAC1WYNnE-TFiE STERLINGnp CaIc=MJB Frortpoorfa�xN wrightsoft Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LK. Fr. PIERCE, FL 34946 Phom: 772-466-6799 F=772466-6796 Emil: QUICKCALCS@AOLCOM I Roomn WC PA BATH 2 EVcwdvvall Oft 8.0 It 3 Roomheight 8.0 ft hmVcxl 810 ft heaV=l 4 Roomdnlensicm 7.0 x 9.0 ft 7.0 x 8.0 It 5 Rwm,m 63.0 fF 56.0 ft' Ty Con&ucfon LI-value or HTM Area (IF) Load Area(ft.) Load number(BtuhAtLF) (SWIM or pefimew ('11) (Shuh) � penmeter (ft) (Bbh) Heat Cod G= M/P/S Heat . Cool Giva MAS Heat Cwj 6 V�I '. 13AAa 0.143,-m -,400 *' 2.55 b "0 6 o -o 0 T 0 .1270 �-rd, �,jjj� �. , _,70.43 _0 0 0 1 0 0-- :� 7 laA-4=' 0.143 w 4.00 2.55 0 0 0 0 a' 0 0 0 1AcIom 1270 w 35.55 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 w 10.92 11.31 0 0 0 a 0 01 0 0 w . -': .134�. ; - , - , , 0.143 "S'. .:4.00Z55 0 0- 01, o '0 ;wl' -o w lak-4= Q143 w 4.00 255 0 0 0 0 64 — 228 145 L - 1AcIom 1.270 sN 35.56 4291 0 0 0 0 7 5 247 298 0.143 my 4.00 '7Z55 0 -0 -0 o o -0, 1270 fiw A-'4524 .0 -,0 0 "'.10 - ., or 0 0 0 z� AA5�2 OM-' 0.770 'nW 121M, 0 0 0 10 �—.-'O 0 �':Q' ­0 P 12C-Ow 0.091 U5 8 0 0 0 0 0 c 0 0 9.02 —2.32 "63 3 66 _146 M 10 F 0.989 — - 27.69 0.00 63 0 0 0 222 11-130 0 z' 6 C) AED e=sM -2 225 EnvelopeloWigain 56 145 747 798 12 a) ll 0 0 140 38 b) Roomwinlilafion 0 0 0 0 13 Inbamilgaim O=P-fS@ 230 0 0 0 0 ce Applims(offler 0 0 1 SLbb3b10irm6t713) 56 145 au 836 Lmexemalload 0 0 0 0 Lewransw 0 0 0 0 Red&bulon 0 0 0 0 14 Subblal- 56 145 897 838 15, Ductioads 1 31%1 481/61 IS 691 31% 48o/. 276 399 ToW room load 4 74 214 11 62 12 M Air reqdred (cfrn) 9[ 571 54 CalculaUclns approved WACCAto meet all requirements of Manual J 8th Ed -Pk- wrilaftt�ft- 2019-Sep-1709:31:11 Aftk• Mgt&StiteOLkiwm[201919.0.07RSUGBIOI Page 2 ��rbkwdgNWRHVAC�WYNKrE-THESTERLINOYLP Calc=MJB FrortDaorfaces:N wrightsoft Right4g) Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LIM, Fr. PIERCE, FL 34946 PhDm:772-466-6799 F=772-466-6798 Emil: QUICKCALCS@AOL.COM 1 Roorrinam, KITCHEN BATH 2 EVosecivell 0 ft 5.0 ft 3 Room height 8.0 It heaV=1 8.0 ft heavo:01 4 Roomd1mendons 1.0 x 1920 ft 9.0 x 5.0 It 5 Roornapea 192.0 Iti 45.0 IF Ty Consirudon U-value Or HTM Area (W) Load Area (R) Load number (Btulllft9 (fth" or Perimeter (11) (Bbill) or perimeter (IQ (Bbih) Heat �C-d Gross NPIS Heat cool Gross I WNS Heat cool 6 N G 0.143 ne A00 .255, 0 0 a .o ;40, 40- '160 102 "1270:'ne- nm '70AS :,o 0 0, 0 0 o 'o - o w 13A-as 0.143 so 4.00 Z55 0 0 0 0 a 0 o 0 E2IA.clom 1270 w 35-% 34.77 0 0 0 0 a 0 0 0 I; 11130 w 10.92 11.31 0 0 0 0 0 0 0 0 w iaAAocs-1:17 - .0.390 0.143 -•S - - - A.00 -2-55 -- -,0 0'-- - 0 0 0-- iz"ws 0.143 w 4.00 2.55 0 a 0 0 0 0 0 0 1Aclom 12M w 35.% 4291 0 0 0 0 0 0 0 0 0.143 '�?IW 400 -- 2M 0 a 0 .0 1270 rTW :3� o" 0 ;'0 0 0". '0 0 �i- 4 0 -M VA54 4, . , 0 0 0, 1 0 �,.:o P 12c-uw 0.091 255 1.28 64 64 163 82 0 0 0 0 c �0.63 0.90 192 192 --::172 -"445 45 �4 4q 164 F 22�,-tpl 0.989 t 27.69 0.00 192 0 0 a 45 5 138 0 F I ILI I Envelopelossbaln 3351 5011 1 1 3391 2041 12 a) Infiltration 0 01 1 1 .0 0 871 214 0 b) Room%enlifidon 0 01 1 0 13 Internalgairs O=pants@ 230 1 01 1 1 01 01 1 0 Le'oe"am"'oe' Lemransfer Redistribution 14 Subblal 16 Ducticeds 2501 Calculatons approved byACCA to meet all requirements of Manual J 8th Ed A%-rk- wr o201"ep-1709:31:11 k —L— mn'tre — Rglt-SufteO Uiveml 2019 1 9b.07 R8UD81 01 -0�rMV*igtboftWACkWYNNE:-THESTERUNGjW CaIc=MJS FwrtDoorfa= N Page3 wrightsoft- Right. -A) Worksheet Job: Entire House Date: QUICK CALM, INC. By. -.1 1=11:WlMlnYUiO'(IPAUL.UUM I Room name BEDROOM2 ENTRY 2 =Tflt 322 ft 7.0 ft 3 1, 8.0 9 hwV=l 8.0 It heaV=l 4 Roomcrimmuom 1.0 x 203.5 ft 1.0 x 55.0 ft 5 Rooma 2035 ft' 55D fF Ty Conshdon U-Value Or HTM rWm(" Load Arm (fl?) Load number (l3UVTt1-*F) eter (Btah) or Wmet2r (fo (BLh) Het Cod G. NIPS Heat Cool Gross NIPS Heat Coal 6 W, �1344om '0:143 m 4.00 255 128 12.8 513 :! .1325 ­0 to 0 0 LG Ofii - :1270 �7 ne MW J7 O�i 70 .,0 �-,o '.0 t1a 0 - " 6 w 0.143 m 4.00 255 30 66- 143 48 26 -166 _0 67 G E:D IA-dom 1270 m 3556 34.77 24 24 848 829 0 0 0 0 1 11D0 0.390 m 1092 11.31 0 0 0 0 22 22 236 244 W " '-13A ,0.143-s, A.00 Z55 '34 34 136, M 0 U- �.o _o W" 1—G 13A4= IA-dom '0.143 w 4.00 255 16 1 , 6 64 41 8 1 8 32 1 20 1270 w 35.55 4Z91 0 a 0 0 0 a 0 0 '0.143 nw 400 255 0 0 0 0'.'- O 1-0 tAclom270 2556 49.24 0 0 --o t�, 0 10 . "0 yo :O 10 .'.',0.770 �,:--21.56 �V,54 ;6 �b-- - '-o i 0 0 0 6 p 12c-ow 0.091 255 128 0 a 0 0 72 '0 72 183 92 C:—t .14Aoftid", '0.032 -ASO '132 `204= ,. 204 - 182 A72 55 46 F 2244p1 0A89. 27.69- - - 0.00 32 891 0 55 194 0 7. 6 c)AEDexalr lm -8 En%,EROpelOW9n 2859 1873 ano 545 131 Intemalgaim 0—panls@ 230 1 230 01 01 Apprimmsbft 1 0 1 0r SubblaloinwStD13) 3422 2257 9m 579 Le adamal low 0 0 0 0 Lmtansfer 0 0 0 0 Redistribution 0 0 0 0 14 SLftfal 3422 2257 m 679 15 Ductloads 31% 48% 1064 1078 31% 48% 287 276 Told mom load 4486 3335 1209 m ArreqLdmd(cfm) 218 146 59 91 38 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. A&k Rlglt-SLjte4DUNwml 201919.0.07 RSL)08101 201"ep-1709.21:11 -.0�rdslWdghtwftWAMWYNNE-THE Calc=MJB Fmr1DoorfbmT. N Page4 wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. y: 317 ST. LUCIE M, Fr. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: CIUICKCALCSMAOL.COM I Room name LAUNDRY GREAVDINING 2 EVosedwall 6.0 It 46.0 It 3 Room height 8.0 R heat1cool 8.9 ft hwVmol 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 It 5 Roornanea 420 IF 488.0 ft' Ty Construction U-value Or HTM Area (IF) Load Area (" Load number (Btjftfitz°F) or Perimeter (fo (Bhih) or perimeter (to (Bbih) Heat Caol Gross NMS Heat Cool Gross N)FIS Heat Cool 13A4cas 0.143 4.06 ss a 0 -0 -0 '231 ;1 776 493 Ak .1270:,:n6-. Aw 7OA3 '0 0 0 0 38 'o A344 VL 13A-4= 0.143 se 4.00 2Z5 0 0 0 0 0 0 0 0 ___a 1A-clorn 1270 se 35M 34.77 0 0 0 0 0 0 0 0 1 11DO 0.390 se 10.92 1131 a 0 a 0 0 0 0 0 W I 3A4ocis'- 0143 -ST 4.00 -2.55 0 0 0 o o 0- �'o w L--G V 1Ac1om 0.143 w 4.00 255 48 48 192 122 0 0 0 "o 0 1270 w 35.56 4Z91 0 0 0 0 0 0 0 0 A3A-4ock.m— 2.1 55 0 0 0 0- 178 137 549 �349 1, A, om M, 35.56 �4 24 ��-c 0, a wo 0 , -0 .0. 0 4A5-tom -21.56 .54 0 0 Z'-10 0., 41 - !0 P 12C-Ow 0.091 2.55 1.28 58 58 143 72 0 0 0 -1124 0 Q632 0,90 �2.32 :42 42 38 97 488 ,488 3 Z ��jj U F 22A-ipl 0.989 'X 27.69 0.00 42 6 166 0 488 46 1 '4 1274 0 f 6 c) AED e=gzlon -3. -56 Envelope loWgaln 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Roomvenulatton 0 0 0 0 13 Interval gains: OOMT-fb@ 230 0 0 2 460 Appliancesbtw 0 0 Subblal (Iines 6 to 13) 644 317 6154 6409 Less e)demal load 0 0 01 0 Lessinnslar 0 0 0 0 Redisbibullon 0 0 0 0 14 Subtotal 644 317 6154 6409 16 Ductloads 31%1 48% 200 1511 31% 480A 1913 3060 Total room load 844 468 1 8067 Mg Air required (drn) 41 21 393 416 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Ar 201"ep-1709:31:11 FJq1&SLAe4D Universal 201919.0.07 RSU08I 01 Page 5 ,a+neTb\WdgttsoRWAMWYNNE-THESTERLINGAp Calc=MJB Fror(DoorfacemN Duct System Summary Job: wrightSOft° Date: Entire House 9y. QUICK CALCSi INC. 317 ST. LUCIE I.N. Fr. PIERCE, FL 34946 PIMM:77236"790P=77246878798 Email:OUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT . THE STERLING, FT. PIERCE, FL SQemal static pressure Pressure losses Available: static pressure Supply / retum available pressure Lowestfdction rate Actual airflow Total etfecHve length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0284 in/100ft 1160 &n 176 _ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/10011 1160 cfln Name Design (Btuh) Hq (cfln) Clg' (cfm) Design FR Diam (In) H x W (In) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA7H h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREATMINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22A 135.0 ' st2 GREAT/DINNGB c 4735 196 208 0.307 7.0 Ox0 VIFx 28.1 135.0 st2 KITCFEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 stl LAUNDRY h 844 41 21 0.366 6.0 Ox0 VIFx 21.6 115.0 stl M. BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 115.0 stl MASTERBEDROOMA - h 3501 170 149 0.297 6.01 OxO VIFx 33.1 135.0 st2.' MASTERBEDROO" h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 `MC o ' 214 4 9 0.310 4.0 Ox 0 VIFx 26.3 135.0 st2 Trunk Hq Clg Design Veloc Diam H x W Duct Name Type (cfm) (drn) FR (fpm) (In) (In) Material Trunk sa PeakAVF 737 724 0.284 938 12.0 0 x 0 VInIFIX st1 911 PeakAVF 1101 1122 0284 1050 14.0 0 x 0 VinlFlx y -Fli- Wrightson' 2019-Sep-1709a1:11 . xr�,� RigM-StiL&Lkimrsal201819.0A7RSU08101 �Page ^�� �a rdAWdgWzftWACIWYNNE•THESTERLiNGny Calc=M18 FmdDoorfamxN Name Grille Size (in) Htg (Cfm) Cig (cfm) TEL (it) Design FR Veloc (ipm) �Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mad Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 1 MFx WVrlgi7tSOfL 2019-Sep-1709:31:11 C per+: ,.rw..r Ri9n-SusGLhwrsa1201919.0.07 RSW8101 Paget .-oa &%WAgrsoBWAMWYNNE-TFESTERUNGjW Calc=MJB Frort Doortaws:N