HomeMy WebLinkAboutENERGY EFFICIENCY CODE-\I:k\.�---- (3 cu�/
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT
SCANNED
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
B
City, State, Zip: FT. PIERCE, FL,
Permit Number:
St LUCI@
Owner: �(� V
Jurisdiction:
COUnty
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types.(1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a, Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft-
b.Frame-Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types It 504.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft2
6. Conditioned floor area above grade (ft2) 1474
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
0. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Atfic
6 175
a. U-Factor. Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
'
b. U-Factor.. Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtulhr Efficiency
,SHGC: SHGC=0.27
a. Central Unit
- 34.8 SEER:15.00
c. U-Factor: NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab-;bn-Grade Edge Insulation R=0.0 1473:50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Patel
GlasslFloorArea: 0.096 Total Proposed Modified Loads: 47.97
PASS
Total Baseline Loads: 48.55
1 hereby certify that the plans and specifications covered by
Review of the plans and
kiESj
this calculation are in compliance with the Florida Energy
specifications covered by this
Ogg
�. p
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 1-9-2D
this building will be inspected fori
-II a
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code
G'Oljy��
OWNERIAGTN
BUILDING OFFICIAL:
DATE: \\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403:3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2):
1/812020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1474
Lot#
Owner Name: Total Stories: 1
Block/SubdMsion:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ / Design Temp
V Design Location TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree. Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Healed
1 BEDROOM 329 2632 No 0
1
1 Yes
Yes -
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space, Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM - 52 It 0
329 ft2
_
0 1
0
-2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
_
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft D
56 ft2
_
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft2
_
0 1
0
5SIab-On2Grade Edge Insulatio BATH Sit 0
45 ft2
_
0 1
0
_ 6 Slab -On -Grade Edge Insulatio - BEDROOM 2 32.2 ft 0
203.5 ft2
_
0 1
0
7Siab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 112
_
0 1
0
1/812020 4:48 PM EnergyGauge® USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter PerimeterR-Value
- Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
_
0
1
0
9SIab-On-Grade Edge Insulatlo GREAT/DINING 46 ft 0
488 ft2
_
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pilch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1553 ft2
246 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 1t2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
_ 3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
_ 10 Knee Wall (Vented) BEDROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent VNII Type. Space Cavity Width
Height
Ft In
A�n
Sheathing Framing
'tj0
Solar
Below
1 NE=>SW Exterior Concrete Block- Int InsuBEDRGOM
4.1 10
0 8
0
80.6 ft2
0
0
0.4
0,
_ 2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH
4.18
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int InsHEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsEEDROOM 2
4.1 4
3 8
0
34.0 ft2
01
0
0.4
0
9 SW=>NE Exterior Concrete Block- Int InSBIEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
_ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
6.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block- Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Int InstiSREATMINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
_ 14 NW=>SE Exterior Concrete Block- Int InstfEi REATIDINI
4.1 20
0 8
0
160.0 ft2
0 -
0
0.4
0
1/8/2020 4'.48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
15 N=>S Garage Frame -Wood
KITCHEN 11 24 8 192.0 ft- 0.23 0.4
0
DOORS
# Omt
Door Type
Space Stones U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None .39 3 1 6 8
20.6 ft-
WINDOWS
Orientation shown is the entered. orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp Area _ Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
-Low-ESingle
Yes 1.04 0.29 N 32.9 ft' 1 ft 0 In 1 ft 5in Drapes/blinds
Yes 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in None
Yes 1.04 0.29 N 24.0 IF 6 ft 0 in 1 ft 5 in None
Yes 1.04 0.29 N 37.5 ft' 1 ft'0 in 1 ft 5 in None
Yes 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds
Exterior 5
None
None
None
-.Exterior 5
GARAGE
# Floor Area
,Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315W
315 ft' 24ft 8ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233 7
HEATINGSYSTEM
# System Type
Subtype Speed Efficiency Capacity .Block
Ducts
1 Electric Heat Pump/
Split Singl HSPF:8.5 34.8 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
_Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap Use SetPnt Conservation
1 Electric
None
Garage -0.97 40 gal 60.9 gal 120 deg None
1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017'FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SI IMMAPV (`W=P-I11 IRT PFPnl2T
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
-
Carl # Company Name
System
Model # Collector Model#
Area Volume
FEF
None None
ft'
DUCTS
/ -- Supply—
— Return —
Air
CFM 25 CFM25
HVAC #
V # Locallon R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT ON RLF
Heat Cool
1 Attic
6 175 ft?
Attic
65 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Crreiling Fans:
Cooling Jan Feb
Feb
Ventng
Mar
Mar
Apr
Apr
ay.
gIrXI'
�Aug
Sep Octr( �'
DecNovr0C'I
[ ]Jan.
[
May
[ Jun [ JulJul
[
Sep [ ]X
Nov
[ ]D
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
'66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
. PM
68
68
68
68
68 68
68
68
68 .68
66
66
MASS
-Mass Type
Area
Thickness Furniture: Fraction
Space.
- Default(8 lbs/sq.ft.
0 ft-
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 lbs/sq.fL
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.fL
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(B lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 Ibsjs.f,
ft',
ft"
0.3..
GREAT/DINING
1/8/2620 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
I
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Y
Owner. Jurisdiction:
w
Design Location: FL, Fort Pierce
=
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General ,
Acontinuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealin material,
g
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any droppedceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shag be sealed.
Walls
The junction of the foundation and sill plate shallbesealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulatedbycompletely filling the cavity,
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope. insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include theairbarrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any "posed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above,garage
subfloor decking, or floor framing cavity insulation -
and cantilevered
shall bepermittedto be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottomto the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where. provided instead of.floor insulation, insulation
a Class I vapor retarder with overlapping joints taped. _
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
-
-
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned Spot
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall besealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulagon that on
installation readily conforms to available space shall
Exterior walls adjacent to showers and tubs shall
Shower/tub
The.. air barrier installed at exterior walls adjacent to showers and
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated. -
Electrical/phone box or
The air barrier shall be installed behind electricalor communication
exterior walls
boxes or air -sealed boxes shag be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
-
Concealed
When required to be sealed, concealed fire sprinklersshall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
"
Caulking or other adhesive sealants shall not be used to fill voids
lailrpilinas
a. in ad ddion, inspection of ogwalls shall bean accordanceynth the propislons of ICC-400;
1/8/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
4. 2.
5. Is this a worst case? (yes/no)
5.
Yes
6. Conditioned floor area (sq. ft.)
6.
1474
7. Windows, type and area '
a).U-factor.(weightedaverage)
7a.
1.060'
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
c) Area
7c.
141.3
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a)Slab-on-grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
13. Cooling system:
Capacity 34.8
a) Split system
- SEER 15.0
b) Single package
SEER
c)Ground/water source
SEER/COP
d) Room unit/PTAC
EER
e) Other
14.,Heating system:
Capacity 34.8
a) Split system heat pump
HSPF - 8.5
b) Single package heat pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
9a.
0.0
9b.
-
15. Water heating system
9c.
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with tank EF_
10A2.
4.1
f) Heat recovery unit HeatRec°/a
g) Other
1061.
11.0
10B2.
16. HVAC.credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
- 19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating,credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features.which will be installed_ (or exceeded):in this. home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING. \ C� VC4c4Q^ City/FL Zip:. FT. PIERCE, FL
1/8/2020 4:49:01 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
IC
Project Name: WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT
BY
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY St. Lucie
City, State, Zip: FT. PIERCE FL ,
,
Owner: \Q0 � Q �
Permit Number:
Jurisdiction:
Count y
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 112
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ft2
E. Is this a worst case? Yes
10. Ceiling Types (1474.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft2
6. Conditioned floor area above grade (ft2) 1474
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.03
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
Sj -
this calculation are in compliance with the Florida Energy
specifications covered by this
O�'CS>:
y , _ OA
Code.
calculation indicates compliance
y iir, ° `'
with the Florida Energy Code.
•L y ;'`°„ O
PREPARED BY:
Before construction is completed
�•em
r lc O
DATE: -
this building will be inspected for
compliance with Section 553.908
C� R e y
* ¢
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
daith the Florida Energy Code.
G'Op WE
OWNER/A NT.
BUILDING OFFICIAL:
DATE: \K
DATE:
- Compliance requires certification by the air handler unit manufacturer th the-aichandler enclosures&,qua 1`Yifies s
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50R`I'VIEWED FOR
CODE GOMPL9ANCE
ST, LUCIE COUNTY
BO rC
9/11/2019 12:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1474
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH _MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
329 ft'
0 1
0
2Slab-On-Grade Edge Insulatio
WIC 1 ft 0
63 ft2
-_
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
-_
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft'
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 fF
__
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft'
-_
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft'
___
0 1
0
9/11/2019 12:12 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
t-UKIVI K4U0-zU1 / INVU I SUMWIAKT l+F1tL;KL15 I KLFL)K I
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft- ___ 0 1 0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' _- 0 1 0
ROOF
/
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck Pitch
V
#
Type
Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul. (deg)
1
Gable or Shed
Metal 1553 ft'
246 ft'
Light N
0.6
No 0.9
No 0 18.4
ATTIC
/
V
•
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
150
1474 ft'
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
BEDROOM
30
Blown
329 ft'
0.1
Wood
2
Under Attic (Vented)
WIC
30
Blown
63 ft'
0.1
Wood
3
Under Attic (Vented)
M. BATH
30
Blown
56 ft'
0.1
Wood
4
Under Attic (Vented)
KITCHEN
30
Blown
192 ft'
0.1
Wood
5
Under Attic (Vented)
BATH
30
Blown
45 ft'
0.1
Wood
6
Under Attic (Vented)
BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7
Under Attic (Vented)
ENTRY
30
Blown
55 ft'
0.1
Wood
8
Under Attic (Vented)
LAUNDRY
30
Blown
42 ft-
0.1
Wood
9
Under Attic (Vented)
GREAT/DINING
30
Blown
488ft'
0.1
Wood
.CIA Ili
WALLS
1 NE=>SW Exterior
Concrete Block-C-A Ins®EDROOM
4.1
2 SW=>NE Exterior
Concrete Block - Ext Ins(REDROOM
4.1
3 NW=>SE Exterior
Concrete Block - Ext Ins®EDROOM
4.1
4 SW=>NE Exterior
Concrete Block- Ext InsuM. BATH
4.1
5 NE=>SW Exterior
Concrete Block- Ext Insul BATH
4.1
6 NE=>SW Exterior
Concrete Block - Ext InREDROOM 2
4.1
7 SE=>NW Exterior
Concrete Block - Ext InREDROOM 2
4.1
8 S=>N Exterior
Concrete Block - Ext InaEDROOM 2
4.1
9 SW=>NE Exterior
Concrete Block - Ext InQIEDROOM 2
4.1
10 SE=>NW Exterior
Concrete Block - Ext Insul ENTRY
4.1
11 SW=>NE Exterior
Concrete Block - Ext Insul ENTRY
4.1
12 SW=>NE Exterior
Concrete Block - Ext InsdIAUNDRY
4.1
13 NE=>SW Exterior
Concrete Block - Ext lne REAT/DINT
4.1
14 NW=>SE Exterior
Concrete Block - Ext Ins REAT/DINT
4.1
15 N=>S Garage
Frame - Wood KITCHEN
11
10
0
8
0
80.0 ft'
28
0
8
0
224.0 ft'
14
0
8
0
112.0 ft'
8
0
8
0
64.0 ft'
5
0
8
0
40.0ft'
16
0
8
0
128.0 ft'
10
0
8
0
80.0 ft'
4
3
8
0
34.0ft'
2
0
8
0
16.0 ft'
6
0
8
0
48.0 ft'
1
0
8
0
8.0 ft'
6
0
8
0
48.0 ft'
26
0
8
0
208.0 ft'
20
0
8
0
160.0 ft'
24
8
192.0 ft'
Sheathing Framing Solar Below
o v.a..e c....a:.... Ak..... n_.. Aw 0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0
0
0.4
0
0.23
0.4
0
9/11/2019 12:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
1.04 0.29 N 32.9 ft2 1 ft 0 in 1 ft 5 in
1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 5 in
1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5 in
1.04 0.29 N 37.5 ft2 1 ft 0 in 1 ft 5 in
1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 112
315 ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Duds
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
9/11/2019 12:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECK[ IAT REPORT
DUCTS
/ —
Supply
—
—
Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6
275 ft2
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablee
Y
Ceiling Fans:
]ThermostarXt;
Heating [X] Jan
Feb
rX]j'
Mar
[ ]
[ ] Apr
]May
Jun
r[[ ]]
Jul
[[
[X� Aug
r ]]
Sep
(j
L
H
Nov[rX']NovrX't
Dec
Venting [[ 11 Jan I 1
L 1
Feb
L><l
(Rl Mar
[X]
1
lXl Jun
[ Jul
lXl
[[ Aug
[ Sep
lXl
IXl Oct
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
'Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
112
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
It
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(S lbs/sq.ft.
ft2
It
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
GREAT/DINING
9/11/2019 12:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction:
w
x
Design Location: FL, Fort Pierce
�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pin no and w rqno
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
bub&PPn fire s rink! cover plates and I !no
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/11/2019 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
1) Heat recovery unit HeafRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. 1
Builder Signature: Date: \\,` , \
Address of New Home: THE STERLING -\Lp \21 l.'��Q.NX _C� City/FL Zip: FT. PIERCE. FL -7=-'-�9'A! �
9/11/2019 12:12:47 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wrights(oftProject Summary a�1
Entire House 9y.
QUICK CALCS, INC.
317ST.LUCIEMFT.PIERCE,FL34949Phom:77246W99 Fac772499A796 Ema1:QUICKCALCS@A0L.O0M
For. ESTREPTTHEELNGF. PIERCE, FL SCANNED
\ la 0 4u BY
Notes. St. Lucie County
Weather.
Winter Design Conditions
Outside db
Inside db.
Design TD
Fort Pierce, FL, US
Summer Design Conditions
42 OF Outside db
70 OF Inside.db
28 °F Design TD -
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure
18188
Btuh
Ducts
5650
Bbuh
Central vent (0 cfim)
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipmentload
23842
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
ln
Area (n He 1474 Co 1474
Wlume
1043.
1023
Airchan(gge)slhour
Equiv.AUF (cfm) 92
47
Heating Equipment Summary
Make Cartier
Trade CARRIERAIR CONDITIONING
Model 25HBC536RO30
AHRI ref '7914585
1;M2. 3;M
34600
Btuh@47°F
27
OF
1160
0.049
,cfm
cfm/Btuh
0.50
in H2O
33 OF
Ilnutt=7WV, Output= 23009 Btuh, 100 AFUE
90 OF
75 OF
15 OF
50 %
61 gr4b
Sensible Cooling Equipment Load Sizing
Structure
17877
BtuhDucts .
8530
Central.vent (0 ctm)
BBbrh
(none)
Blower
0
Btuh
Use manufacturers data
n
Ratef,swingg multipplier
Equipmentsensible.load
0.95
25093
Btuh
Latent Cooling Equipment Load Sizing
Structure
2958
Btuh
2310..
Central vent (0 cim)
Btuh
(none) -
Equipment latent load_
5277
Btuh
Equipment Total Load (Sen+Lat) 30370 Btuh
Req. total capacity at 0.70 SHR 3.0 ton
Cooling. Equipment Summary
Carrier '
CARRIERAIR CONDITIONING
25HBC636MO30
FX4DN ;F)037
ref 791458
12.0 EER,15 SEER
24360
Btuh
10440
Btuh
34800
Btuh
1160
cfm
0.044
cfmBtuh
0.50
in H2O
ratio 0.83
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
w 2019Sep1709:31:10
Akr891tSYte&Lhwrsa1201919.0A7RSLI08101 Pagel
...DomerbXWdg�itWAQWYNNE-THt SMkLINGnq Cale=WS FrortOoorfaces N
wrightsoft- RighW@ Worksheet Job:
Entire House Date:
QUICK CALLS, INC. By.
317 ST. LUCIE LM. Fr. PIERCE, FL 34946 Phom:772-466-6799F=772-466-6798 Emaal:QUICKCALrS@AOL.COM
I
Errfim Ho
IVASrERBEDROOM
2
EVosadvall
1662 ft
520 R
3
Room Wight
8.3 Q d
8.0 ft heaftol
4
Room dimension1.0
x 329.0 111
5
RcomaIm
1473.5'ft'
329.0 IF
Ty
Con&ucfon
U-value
Or
HTIVI
Area (M
Load
Area M
Lmd
number
(ftw
or perimeter00
(Btuh)
or perimeter (f)
(Bah)
Heat
I Cod
Gross
NPIS
Heat
Cool
Gross
NAPr.
Heat
Cool
6
W 1,
13A4ods
0.143
-'ne
400
'.35.55
' 2.55
479
442,
1768
1124
--8
.18
320
- � 9m
1270
�A�70A
1344
�:2562
0
:0
1,'
�, %,,�
w
0.143
4.0)
2.55
128
83
331
21 0
0
0
0
;
1
Ei
1A-clom
1270
w
35,56
34.77
24
24
848
629
0
0
0
1
11
11DO
0.390
w
10.92
1131
22
22
236
244
0
0
0
WE
Jm4ar;1:�
,
:o 143_S
.4.0
--2.55
34
_
I 1136
'6B
0
O
)
Dw
L—G
13A4=
1A-Wom
0.143
SW
4.00
255
360
353
1414
899
224
224
897
570
1.270
w
35.56
42.91
7
5
247
298
0
0
0
0
13A46cs
0.143
400
2.55
290
�217
551
12
79
'�318
202
lXdoffi
' 1.270
rw
35.66
4524--
'33
0
1478
0
-,1162
1478
—0.770
21.56
:26.54
i,`
4- 1
.-0
--,880
t-�.
.1124
.6
.... .. 0
xv
'0
p
12C-Ow
0.091
2.55
1.28
192
192
489
248
0
0
0
0
C164
_:.0'0.32
r'.'OM
'-2.32
::'�',1474,
.1474
3419
:329 -
3f9
7M'
,7r63
F
22A,%A
ro
0.989.
27.69
0.01
156
4vz
0
M
52
144Q
0
r
2
7
12
a) Motion
28221
771
909
249
b) Ro veMlawn
0
0
1
1
0
01
13
InbNnel gaim O=pants@ 230
5
1150
21
460
ApprimardaTier
2000
0
Subbtaloines6tD13)
18188
17SR
5341
4606
Lessademadload
0
0
0
0
Lmtansfer
0
0
0
0
Redisbibulon
0
0
0
0
14
SubbW
18188
17877
5341
4606
15
Ductloads
31%
48-1
5654
85W
31%
W1.
1660l
2199
ToW mm I�d
26413
1
70011
6805
Air mcIdred(c1m)
1160341
299
Calculations approved bvACCAtc) meet all requirements of Manual J 8th Ed
-PW wr3j3ft�cwt-
I&Fp, ggft-StiteOLhwrsal2Oi9l9.0.07RSLI08101 2019-Sep-1709:31:11
�rts%WdgftsoftWACkWYNNE-THESTERLINGjW CBIG=MJS FmriDoorfacesA Page 1
wrightsoft- Right-M Worksheet job,
Entire House Date:
QUICK CALICS, INC. By:
317STLUCJE I.M. Fr. PIERCE, FL34946 Phom:772-466-6799 F=772-46"796 ErnW]:QUICKCALCS@AOL.COM
1
Roomrme
vvic
K BATH
2
EVomdmdl
oft
8.0 it
3
Roorn height
8.0 ft hWboof
8.0 It heaVC001
4
Room crimerislom
7.0 x 9.0 ft
7.0 x 8.0 It
5
Room area
63.0 W
56.0 fe
Ty
ConsWobon
U-value
Or
HTIVI
Area IT)
Load
Arect (fF)
Load
number
(BbihAPL9
(amm
or perimeter (10
(Okb)
a perimeter R
(Nah)
Heal
Cool
Gross
NIPIS
Ha
Cool
Gross
NIPIS
Heat
CMI
6
.4.00
2.55'
0
0
0
;, 0
0
0-:
1,
AXOOM m"
1270
Iris-,
35 56
;7OA3
; � �O
_0
-0
,
0
0
0
20
�,
ln� -,Q
0
w
1�
Q143
W--
4.00
255
0
0
0
0
0.
0
a
1p,dom
1270
w
35.56
3477
0
0
0
0
0
0
0
0
11
11DO
0.390
m
10.92
1131
0
0
0
0
0
0
0
0
0.143
A00
:i :255
0
, 0
0
0_
0_,
�,'O
2�0
`0
w
L1-.G
laA-4=
IA-clom
0.143
4.00
255
0
0
0
0
64
57-
228
-
145
1270
w
35.56
42.91
0
0
0
0
7
5
247
298
W-
L:ma�
13"Ac&-
JA�,clb�n
0143
�:'1�
lrii
4.00
;35.56
-�P 55
0-
0
.
0
'0
.
0
10
00
-
70
r1w
I
924'
0
0
0
. 0-
I . '0
-,0.770
rnv
21.56
-`-:27.54
:� O
O
-jo
0
0
'-0
P
12c-Ow
0.091
255
128
a
0
0
0
0
c
0
0
16AM•- rffd,'i7T-
V
090
',402
`11 '63.,
66,
146
56-
0.989
27.69
0.00
63
a
0
0
56
8
222
--130
0
7"':
4
%
j
6
c)AEDe=m§m
1
1
561
145
1
1
747
7981
121
0 frififttcin
c
0
140
38
b) Roorriverri
0
0
0
0
131
Interrid gem OmuparrtD@ 230
0
0
0
0
Apprianoeebtrier
0
0
Subtotal Cines 6 to 13)
56
145
887
836
Lessedwrialload
0
0
0
0
Lembransfer
0
0
0
0
Redisinbuft
0
0
0
0
14
Subble
56
145
887
338
15
Ductlocids
31%1
481/61
18
69
31%
48%
276
3d99
9
Tote room load
74
214
1162
235
1235
AirreqUmd(olm)
41
57
64
5
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrffoft�c�ft- 201Mep-1709:31:11
1 — RghtSufteG Lki%emml 201919.0.07 RSL1081 01 Page 2
...oa rbkWdgNmRWACXWYNNE-THESTERUNGnp Calc=MJS FrortDoorlhoe,N
+ wrightsoft- Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY.
317 ST. LUCE LK, Fr. PIERCE, FL 34946 Phom: 772-466-6799 FaX 772-466-6796 Email: QUICKCALCS@AOL.COM
I
Rcomname
KITCHEN
aATH
2
EVOW04
0 It
6.0 It
3
Room height
8.0 ft
heaticool
8.0 ft
hwVcooI
4
Room dimensions
1.0
x 1920 It
9.0 x
5.0 It
5
Roomarea
192.0 111`
45.0 IF
Ty
Construdan
U-value
Or
HTIVI
Area (fV)
Load
Am (fe)
Load
number
(Btuhffl
or pedmeter (M
(BLh)
or pedmetar (f)
(Btuh)
Heat
I C.M.
Gross
NIPIS
Heat
Cool
Gloss
N/P/S
Heat
Cool
6
-i�136A ocs
om
4.06
-'2.55
10
0
0
0'
40
• �40
-160
102
A-dom
�'J:ii6
he
35.56
1,70 A
f 1, ;:0,,
0
- 0
7 0
." 0
�o
:.
, )I
w
1:401�
O.M
w
4.00
2,55
0
0
0
0
0
0
0
0
L-G
IA-dom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
1
ITO
0.390
se
10.92
1131
0
0
0
0
0
0
0
0
W,
�I-ZA
.0.1 43
a
400
'6
2.55
'2.55
..;,0._
.0
0
0:,.
-
,
'-0
;0
- t� , ,
. --';'_'D
ILC
13AAocs
w43
w
4. 0
0
0
0
0
0-
0
0
1A-clom
1270
w
35.55
42.91
0
0
0
0
0
0
0
0
0143
4.00
'-255
... 0
--- 0
_0
0
- 0
'a
lAaclorfi��.'
1,270
35.56:
""Z24
-',0
0
7 0
"�O-
0
• yo
'0
0
E,
AAk-2oai",�--
0.770
'JW,
-21.56
:,F Z7.54
0
0".
-0:
�2
.70
0
.."':0
.0
P
12C.Ow
0.091
255
128
64
64
163
82
0
0
0
0
C'��
�.:0.032?
AGO
��2.32,-�f,,.
�.,192,
.-,,192
44s
45
A 5
40
F
22A-tPI
0.989
2759
0.00.
192
0
0
0
45.
5
138
0
...
h.
6
c)AEDc=Adm
-27
-2,
EnvelDpalossbaln
335
501
339
204
12
a) InfillraWn
0
0
.87
24
b) Rwmveraffadon
0
0
0
0
13
Intamedgains Occupants@ 230
Ol
0
0
0
Apprianaasbt-
2000
0
SuWWOines6lo13)
335
2501
426
228
Lesse)L-malload
0
0
0
0
Lesstransfer
0
0
0
RecWbuton
0
0
0
Ol
14
SubbtaT
335
2501
426
1
228
15
Ductloads
31%
48%
104
1194
311,16
481%
133
109
TOW mom load
439
3695
I
I
I
rZ91
3361
Arrecgred(clim)
21
,.,
27
1.5
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrlgl+esRJgft-Su[te&LWversal2019l9.O.O7 RSU08101
a 20lMep-170911:11
'Ift -0amerds1Wd91tsoftWAMWYNNE-TFESTERLWGnp Calc=MJB FrartDoorfacesA Page 3
wrightsoft, Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.,
317 ST LUaE UM., Fr. PIERCE, FL 34946 Phone: 772-46"799F=772-466-6796 Emil: QUICKCALCS@AOL.COM
I
I Room name,
BEDROOM2
ENTRY
2
EVomdvdl
322 It
7.0 it
3
Room height
8.0 a heat(lecol
8.0 ft heat(leocl
4
Roorriclimensions
to x 203.5 it
1.0 x 55.0 It
5
Roomerezi
203.5 IF
55D IF
Ty
Construction
U-wilue
Or
HTIVI
Area (M
Load
A� (fe)
Load
number
@WhWF)
(Btuhfi*
or Perimeter (f)
Etuh)
a Nrimetar (fo
(fth)
I Heat
Cool
Gross
NJPrS
Heat
Cod
Gross
NIPS
Het
Cool
0.143
rod
' 4.06
-,:35.56
2.55
128
�O
128
'513
�326
'0
,0
- 0
G
270
he-
w 70.43
0
0
.0
— O�-
a
-0
w
0.143
se
4.00
2,55
80
56
225
143
48
26
106
67
E�S
1A-clorn
1270
se35.56
3477
24
24
848
829
0
0
0
0
1�
11DO
0.390
se
10.92
1131
0
0
0
0
22
22
236
244
W,
.13AAocs,
I
LO.143
4.00
Z55
34
34
136
- 86
.0
-,:,! 30:.,
-.1.; '0
13., 6
laA-4cm
'0.143
4.00
255
16
16
64
41
-
8
a
ii
20
1A�Iorn
1270
w
35.56
4291
0
0
0
a
0
0
0
0
01 43
aw
AGO
Z55
0
0
0
0,
0
0
0
-=o
7A clam
1370
, . W.
, -
4524
--0
0
0
0
''
0
.0
�0
0
-0 .770
-,21.56
27.54
01'L
1 _-0
-6
!0
.0
y gi
P
0.091.
-
255.
1.28.
a
n[
n
n,
7�
-01
12
a) Irrilt-alion
5641
154
122
341
1
b) Roarrivenfilation
0
0
0
0
13
Internalgains O—pani 230
1
230
0
0
ApprianoWather
0
0
Subtotaloinw61o13)
3422
2257
922
579
I-Madernalload
0
0
0
0
Lesstransfer
0
0
0
0
Recisbibution
0
0
0
0
14
SubbDU
3422
2257
922
579
15
Ductloads
31%
48% 1
1064
1078
31%
4R-/.
91VI
WA
55
381
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
-FW �jwfv�cwft- 2019-Sep-1709:31:11
,41ft Mgtt-SUteGUriwml20l9l9.O.O7RSUDBIOI Page4
.��rblWdgWUftWACkWYNNE.TFIESTERUNGAp Cale-MiS FrontDoorfaoe&N
wrightsoft- Right-JO Worksheet Job:
Entire HousIb Date:
QUICK CALLS, INC. By.
317 ST. LUCIE UN, Fr. PIERCE, FL 34946 Phone: 772-466-6799 F=772-460-6796 Ernall:QUICKCALCS@A0L.G0M
I
Roomname
LAUNDRY
GREATIDINING
2
EVowdVell
6.0 It
46.0 It
3
Room height
8.0 It heat(cool
8.9 It heat/cool
4
Room dimensions
7.0 x 6.0 It
1.0 x 488.0 It
5
Room area
420 81
488.0 &
Ty
Constadon
U-value
Or
NTM
Area (fe)
Load
Am (fe)
Load
number
(BbuhALT)
or penmebw (to
(am)
a pecmetx (10
(fth)
Heat
Caul
Gross
N/P/S
Heat
cool
Gross
I N/P/S
Heat
Cool
6
1344400a',
0.143
ne�
. 4.06
2.55
0
0
0-
0
231
194,
775
'49:
1270
-'0.143
-� 35,56
',170A3
-'0
0
'.0
38
7%
- 0
1344
26a
w
13A-4=
se
4.00
2,55
0
0
.10
0
0
0
0
0
1
F-G
1A-dom
1270
se
35.56
34.77
0
0
0
0
a
0
0
1
11
,
11DO
0.390
m
10.82
11.31
0
0
0
0
0
0
0
W "
, -
-,13A-
w43
.4.00.,,,,,
;Z55
' Oi
0
0
'
0
:ff-
'0
T--G
la4A=
Q143
w
4.00
255
48
48
192
122
0
0
0
0
1Actom
1270
-w
35.56
42.91
a
0
0
0
0
0
0
0
...0 ' 143
4:00
�.-2,55
0
0
0
.0
:178,.�
'137'-
549
349
AA�q,16m'
- I
�1270
i,35.56
4524
'Z7.sI
0
0
0
0
0
a
4A!5-20m_��
OnO
-
21-',d
-
6
�0.
y %
0
0
10
880
-1 24
P
12r.-Ow
0.091
255
128
68
ss
143
72
0
a
6 0 1
0
Q.-
0.632:
-�090
"2.32
:
42
'42
'A8
97
.',488
'.48
F
0'989
27.69
0.00
42
6
168
0
418
4'
1 274
0
I
Envelope losYgaln
1
5391
288
1
1
5259
57041
12
a) WWon
105
29
895
245
b) Roomvenfilalon
0
0
0
0
13
Inbernal gains Occupants@ 230
0
0
2
460
Appliano5s(otiner
0
0
Subtotal 01naS6 to 13)
644
317
6154
6409
LaSSE&MI1110ad
0
0
0
0
Lemtransfier
0
0
0
0
Redi&bWon
0
0
01
0
14
SdYd2W
644
317
TIA1511
6409
15
Ductloads
3J.".1
4W".1
200 1
151
31-Al
la -Al
qrWV) 1
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-PI&7 wry~ C2!r A& 20IMep-1709:31.11 Rgft-SUte8Wvem120I919.0.07 RSU08101
�o rb\wdgNsoftWAClWYNNE-THESTERLINGnp W,=MJ8 FrontDoorfaces: N Page 5
® Duct System Summary Job:
wrightsoft Date:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN, Fr. PIERCE, FL 34946 P1om:772-46"799Fae772-069-6796 EM!I:QU1CKCALCS@AOLCOM
For. WYNNE DEVELOPMENT
THE STERLING, FT. PIERCE, FL
Heating
Cooling
External static pressure
0.50
in H2O
0.50
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0.50
in H2O
0.50
in H2O
Supply/return available pressure
0.250/0.250
in H2O
0.250/0250
in H2O
Lowest friction rate
0.284
in/100ft
0284
in/100ft
Adualair flow
1160
ch
1160
dm
Total effective length(TEL)
176 ft
Name
Design
(Bluh)
Htg
(cfm)
Clg
(ch)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 559
27
15
0.376
4.0
Ox0
VIFx
18.1
115.0
st1
BEDROOM2
h 4486
218
146
0.374
6.0
OxO
VIFx
18.6
115.0
st1
ENTRY
h 1209
59
38
0.510
4.0
OxO
VIFx
3.0
95.0
GREATIDIMNG
c 4735
196
208
0.318
7.0
Ox0
VIFx
22A
135.0
st2
GREATIDININGB
c 4735
196
208
0,307
7.0
Ox0
VIFx
28.1
135.0
st2
WrCHEN
c 3695
21
162
0.375
7.0
Ox0
VIFx
18.3
115.0
st1
LAUNDRY
h 844
41
21
0.366
6.0
OxO
VIFx
21.6,
115.0
st1
M. BATH
h 1162
57
64
0.366
4.0
Ox0
VIFx
21.6
115.0
SO
MASTERBEDR00%A "
h 3501
170
149
0.297
6.0
OxO
VIFx
33.1
135.0
st2
MASTERBEDR00%s
h 3501
170
149
0.284
6.0
OxO
VIFx
41.1
135.0
st2
WIC
C 214
4
9
0.310
4.0
Ox 0
VIFx
26.3
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Dud
Name
Type
(cfin)
(Cfm)
FR
(fpm)
(n)
(n)
Material
Trunk
st2
PeakAVF
737
724
0.284
938
12.0
0 x 0
V1nlFlx
st1
st1
PeakAVF
1101
1122
0.284
1050
14.0
0 x 0
VinIFIX
wrigh[sOR• 2019-Seµ17631:11
,«w.,v.-.Gs.n Rig"Lite®Urimwl281919.o.07RSW81o1 Paget
A �a 'ris\WA lbolfl NA WWYNKE.TFESTERUNGnp CaIc=MJ8 FrortDoorfaas N
Name
Grille
Size (in)
FIt9
(cfm)
Clg
(cfin)
TEL
(ft)
Design
FR
helot
Qpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1 1160
1160
0
1 0
0
0
Ox 0
1
MFx
� Wrlglhl'SOf . 201"ep-170931:11
AlhiR Aw jz ,n+�rw.�,..,..s Right-SLteGUiversa1201919.0.07RSW9101 Pege2
..pw rds\WdghlsoRFNACIWYNNE-THESfERLINGsw Calc=MJS FrortDoortaWs: N