Loading...
HomeMy WebLinkAboutREVISIONSOFFICE USE ONLY: DATE FILED: ` G ;. d REVISION FEE: �- PERMIT # 1911-0448 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300VIRGINIAAVENUE SCANNED FORT PIERCE, FL 34982-5652 I BY (772) 462.1553 St. Lucie County LOCATION/SITE. ADDRESS: 13410 NW WAX MYRTLE TRAIL APPLICATION FOR BUILDING PERMIT PROJECT INFORMATION -DETAILED DESCRIPTION OF PROJECT REVISIONS: ADD SKYLIGHT NOBS 17-1031.02 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCCO29554 BUSINESS NAME: ROOFING SYSTEMS OF FLORIDA, INC. QUALIFIERS NAME: ARTHUR FRANK" ADDRESS: 583 105TH AVE N SUITE 9 CITY: ROYAL PALM BEACH STATE: FL PHONE (DAYTIME): 561-795-5588 OWNER/BUILDER INFORMATION: JAN 0 6 20?0 Lucie County, Pertr ST. LUCIE CO CERT. #: ZIP: 33411 FAX: NAME: POLLY & STEPHEN CARTA ADDRESS:13410 WAX MYRTLE TRAIL CITY: PALM CITY STATE: FL ZIP: 34990 PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: N/A ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 STATE: Ii�1r:E ZIP: d MIAMI•DADE m DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION OF d.b.a. Guy E. Bird Enterprises LTD 201 Longhorn Road JAN 0 6 2920 Fort Worth, TX 76179 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION I1805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 Scope: I ST. Lucie County, Permitting This NOA is being issued under the applicable rides and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)- This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areasother than Miami Dade County) reserve the right to urposes. If this product or material fails to perform in have this product or material tested for quality assurance p the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meat the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Aluminum Framed Polycarbonate Domed Skylight. APPROVAL DOCUMENT: Drawing No. DADE617.1, model "68F-DADE", sheet 1 of 1, prepared by Birdview Skylights dated 08/22/17, signed and sealed by Vipin N. Tolat P.E., on 10/06/17, and Drawing 4 BVS- X10947-A, sheet I of 1, signed & sealed by Vipin N. Tolat P.B., on 03/28/15, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large & Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein and the dome shall be properly marked by GE Plastics. RENEWAL. of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall LU be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA #15-0413.06 and it consists of this page 1, evidence submitted pages E• 1, E-2, & E-3 as well as approval document mentioned above, The submitted documentation was reviewed by /Heee-lmyy A. Makar, P.E., M.S. MINDADECOUNTY (%� , NOA No. 17-1031.02 Expiration Date: 07/02/2023 oZlO8l2oj$ Approval Date: 02108/2018 Page I Birdview Swishts d.b.a. Guy E. Bird Enterprises LTD NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #03-0303.11 A. DRAWINGS 1. Drawing No. EB696, sheets I & 1, model "6SFD-DADS", prepared by Birdview Skylights, dated 07126100, with no revisions, signed and sealed by V. N. Tolat, P.E. B. TESTS 1. Test report on Large Missile Impact Test per PA 201, Cyclic Load Test per PA 203 and Uniform Static air Pressure Test per PA 202, on "Series 69FD-DADS Se f Flashing Aluminum/Polycarbonate Skylight", prepared by.Miami Testing Laboratory, report No. K-49362 issued on 09110196, signed and sealed by D. G. Ober, P.E. C. CALCULATIONS 1. Anchor Calculation, sheets 2 through 5, dated 08121196 and signed by D. A. Terwilleger, PE D. MATERIAL CERTIFICATIONS 1. Notibe ofAcceptance No. 00-0718.02 issued to General Electric Company on 0910812000, expiring on 0710212003. 2. Extrusion drawings No. BVS X10947-A & BVS 8554 by Tel Tower Extrusions, LTD for Birdview Skylights. E. STATEMENTS 1. No change letter issued by Birdview Skylights, on 0811012000 and signed by E. Bird. 2. No change letter issued by Birdview Skylights on 02111103 and signed by G. E. Bird. 2. EVIDENCE SUBMITTED UNDER. PREVIOUS APPROVAL # 08-0611.09 A. DRAWINGS 1. Drawing No. DADE608.1, model "6SF--DADS " sheets 1 & 2 of 2, prepared by Birdview Skylights dated February 05, 2008, signed and sealed by Vipin N. Tolat, P.E., on July 08, 2008. B. TESTS 1. Test report on Large Missile Impact Test per TAS 201, Cyclic Load Test per TAS 203 and Uniform Static air Pressure Test per TAS 202, on "Series 69F-DADS Self Flashing AluminumlPolycarbonate Skylight", prepared by American Test Lab of South Florida, report No. 0331.01-08, dated 0512312008, signed and sealed by William R Mehner, P.E. and Henry Hattem, P.E. C. CALCULATIONS 1. Anchor Calculation, sheets 1 through 3 of 3, dated 0610912008, signed and sealed by Vipin N. Tolat, P.E. elmy A. Makar, P.E., M.S. Product control section Supervisor NOA No.17-1031.62 Expiration Date: 07/02/2023 E-1 Approval Date: 02/082018 Birdyiew Skylights d.b.a. Guy E. Bird Enterprises LTD NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE I. By Miami -Dade County Building Code Compliance Office, E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 011-0811.08 A. DRAWINGS 1. Drawing No. DADE608.1, model "&F--DADS ", sheets 1 & 2 of 2, prepared by Birdview Skylights dated February 05, 2008, 'revised on February 22, 2012, signed and sealed by Vipin N. Tolat, P.E., on February 22, 2012. B. TESTS 1. None. C. CALCULATIONS 1. None. D. -QUALITY ASSURANCE I. By Miami -Dade County Department of Permiffing, Environment and Regulatory Affairs (PERA). E• MATERIAL CERTIFICATIONS 1. None. 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 13-0311.10 A. DRAWINGS ' 1. Drawing No. DADE608.1, model "68F-DADE", sheets I & 2 of 2, prepared by Birdview Skylights dated February 05, 2008, revised on February 22, 2012 signed and sealed by Vipin N Tolat, P.E., on February 22, 2012. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department ofRegulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. 11 a( / elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No.17-1031.02 Expiration Date: 07/02t2023 E-2 Approval Date: 02/08/2018 Birdview Skylights d.b.a. Guy E. Bird Enterprises LTD NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 15-0413.06 A. DRAWINGS 1. Drawing No. 6DADE14, model "6SF-DrIDE", sheets I & 2 of 2, prepared by Birdview Skylights dated March 19, 2015, signed and sealed by Pipin N. Tolat, P.E., on March 28, 2015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department ofRegulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None, 6. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. DADE617.1, model "6SF-DARE"; sheet I of 1, prepared by Birdview Skylights dated 08122117, signed and sealed by Vipin N. Tolat, P.E., on 10106117, and Drawing # BVS X10947 A, sheet 1 of 1, signed & sealed by Vipin N. Talat, P.E., on 03128115. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department afRegulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. , F. STATEMENTS 1. FBC, 2017 Edition compliance letterprepared by Vipin N. Tolat, P.E, dated 10106117, signed and sealed by lrpin N. Tolat, P.E. C,;Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No.17-1031.02 Expiration Date:, 07/0=023 E-3 Approval Date: 02108t2018 T ( OUTERPOLYCARBONATEDOME(GELEXANXLIOORSHEF.7nLDMAKROLONSL) iB"THICK 2373" INNERPOLYCARBONATE DOME (GE LEXAN 9034 OR SHEFI•TELD MAKROLON GP) .100• TTBCK 11 I O Mill HWHSD WITH NEOPRENE WASHER LOCATED 37/8" 1.50° --1 B FROM EACH CURNERAND 7 I2' ON CEN3'ERTHERFAFIER II 10% OV SPAN, 4MIN. .125" EXC ALUMUgUMANGLE(6D63-TS) G.E. SILICONE ADHESIVE SEAL (SCS 1000 ) CONTINUOUS 10164 SANTOPRENB RUBBER GASKET 41409 CONDENSATE OUTIERWITH0.25" WEEP IIOLE LOCATED AT EACH CORNET[ 010 X LE" SS HWHSMS LOCATED 3 7/8° FROM EACII CORNER AND 7 t2' MAX ON CENTER THEREAFTER I I NOTE: This design can also be used for olper smaller skyligbts as long as the longside does exceed lOS U 'and the short aide .090" FXT. ALUM040M CURB FRAMING 6063-TS ) don not exceed SO 1/4' and mazimwn pnmes do na<zoeed NO ' 4"h1MU3i17M SEE GENERAL positive6D/negative 80 psf. and toW roo�opeaing does a dimrusian ALL ALUMINUMTO BE 6063-TS ALLOY FULLY MITERED AND WELDED ATCORNE N(lI'I;S $2 °m ezceM 50.875 square too[ 6.0" ROOFDECK AND SUPPORT (DESIGNED BY OTHERS) SEE GENERAL NOTES $1 ` f 014 X 1° PAN HEAD LAO SCREW 3 7/8' FROM EAQi CORNER, MAX ON CENTER 712°. W1TH MIN. ROOF DECK 3.0• PENETRATION OF 7/8" i O MAXIUM ROOF OPINING DIMEN f ON 74" X 99" ROOF' MASTIC ALL UNITS EQUAL TO OR LESS T 50$75 Sq. Fit. 3 7/g(Typ-) 114S <9712' ROOF DECK (BY OTHERS) T 14 SCERWSI.S DESIGN PRF„SSURF, RATING I .` 371V(7YP.) TOTALSOSCREWS POSITNE+60psf NEGATIVE-8 sf OP FASTENER LAYOUT SDI/4° AT LOCATIONS V1PINN. TOLAT I0Q7 V4 =7212" A.B&CPOR THIS SKYLIGHT. � PL. EEO.q 12897 LARGE MISSILE IMPACl'RESTS'1'ANT LS=LONG SIDE SS =SHORT SIDE ) t 11 SCREWS SS FOR OTHER SMALLERSIZFS 15123LANTERNCREEKLANF PROVIDE FASTENERS O 7 12" HOUSTON, TX.77068 f ON CENTER EACIISIDE monucrR6sdsen BIRDVIi;W SKYLIGHTS G@IERAL NOTES - u THE CLEAR CWFiOICE 201 LONGHORNRD,FT, �. THIS DESING COMPLIES WITH FBC 61h EDITION ( mmns'N,.>antxmw,u asosasmcad ORTHTX.76179 66 N X•81 -232-B S 2.4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFAC ORBLRWITHOUTINSULATION FOR INSULATION AND ROOFTB-ES ADD TEE TILE HIEGHT ( INSUTATiONTMCKNESSTOTHE4'IMDMAUMHEIGHT. r IS }TIRSHLVGI.E � ° u emu• I t >AT&6-22-2017 MODEL: 65F-UAOH lollL:817-439- Ian r---------EXPOSED— / l taa+ I I S.ODO YFODUCi FEVSED ' tttttSu y,,,• ,.`` �\ N • i0 '•. bldlLitg Cc7e Ampeuue:.o f5- o s o 6 \GEN19 .12847 ° °ocno nc OF Z n STATE • _�L' 1�O,, ...OR��PC�x "Z6 �� 'o,•S�ONA� �,.•` .3j2,$ sEty�L7Hy .575 vau EXCEPT M10DUCT6L06m H mPyirpauLWeFtav+ Acme a WTI�%�- O3 �-OZ �p 1ea�Za23 � A .,tagry cro TOWER B RUSIOW,, LTD.