Loading...
HomeMy WebLinkAboutGENERATOR PAPPERWORKSpecification sheet SCANNED BY St. Lucie Count, FILE COPY CM Power Generation ST.LUCIE COUNTY PLAN REVIEW BLDG: Quiet ConnectrDntA7E: EL Series DATEf� RS36 DATER' MECH: DATE: Features and benefits Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather starts at as low as -40° F. The generator is tested and certified per the latest EPA, UL and IBC Seismic standards and is capable of meeting NFPA110 requirements when equipped with the necessary accessories and properly installed. Flexible Exercise mode - The innovative, flexible exercise mode enables the generator to exercise at a time, frequency and duration that suits the customer's preference - as little as 2 minutes every 6 months - reducing unnecessary fuel consumption, emissions and noise. Weight, size and sound level Advanced Enclosure Design - The; aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint Provides the best anti- corrosion Performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads in accordance with ASCE7-10. The intelligent design has removable panels and service doors to provide easy access for service and maintenance. Self diagnostics and easy service - The generator is equipped with Cummins PowerCommand electronic control to provide industry. leading self diagnostic capabilities. In addition, critical components of the generator are designed to ensure service and preventive maintenance can be completed in a short period of time. Weight: 1294 lbs. (587 kg) Size: Length 94 in (2388 mm), width 34 in (864 mm), height 45.5 in (1156 mm) Sound: 63 d8(A) at 23 it (7 m) with sound level 2 enclosure Rated amps' I Circuit breaker RS36 I C36 N6 DeraOng guidelines: Engine power available up to 1005m (3300 g) at ambient temperatures up to 40G C (104° F). Above these elav am derate at 4% per 305m (1000 it) and 2%par 10° C above 40-C (104° F). t��t � thrlr�W' 02019 Cummins Ina I NAS-SM.EN (srte) AD52GG09 power .cummins.com roduct features Engine • Natural gas/propane 1800 rpm engine • Engine air cleaner —normal duty • Electronic governor, isochronous • Engine starter, 12 VDC motor • Shutdown — low oil pressure • Extension — oil drain • Engine oil Fuel System • Single fuel — natural gas or propane vapor, field selectable Alternator • 60 Hz, 1 phase, 4 lead, or 3 phase, 12 lead, 120 ° C temperature rise at 40° C ambient • Exciter/voltage regulator —torque match Control • PowerCommand 1.1 • Display language — English • Control mounting, right facing Electrical • Single circuit breaker, UL certified, right -side mounted • Battery charging alternator, normal duty • Battery charger-6 Amp, regulated Cooling • Generator set cooling capability — 50° C • Shutdown — low coolant level • Engine coolant — 50/50 mixture • Extension — coolant drain Enclosure • Aluminum enclosure Sound Level 1 with muffler installed, sandstone color • Wind rating —180MPH Code compliance • UL 2200 • EPA emissions, emergency, stationary, 40CFR60 • IBC Seismic • NFPA710 capable Generator set application • Coolant heater • Crank case vent heater • Large battery rack • Flexible fuel line • Literature (English) — operator's manual, installation quick guide and manual, service manual Warranty • Base warranty — 2 year standby • Extended warranties available Packaging • Shipping pallet, poly bag owrft�wd11,u tlwtwa: 02019 Cum w In°. I NAB-e771-EN (en9) A052G009 Generator set performance Governor regulation class: ISO 8528 Part 1 Class G2 Voltage regulation, no load to full load: ±1.0% Random voltage variation: ±1.0% Frequency regulation:lsochronous Random frequency variation: ± 0.75% @ 60 Hz Radio frequency emissions compliance: FCC code Title 47 part 15 Class B Engine Design: Turbo with after cooler Bore: 86.5 mm (3.4 in) Stroke: 100.0 mm (3.94 in) Displacement: 2.4liters (143.5 in3) Cylinder block: Cast iron, in -line 4 cylinder Battery capacity: 550 amps at ambient temperature of 0° F to 32 ° F (-18 ° C to 0 ° C) Battery charging alternator: 50 amps Starling voltage: 12-volt, negative ground Lube oil filter type(s): Spin -on with relief valJe Standard cooling system: 50°C (122° F) aml6ient cooling system Rated speed: 1800 rpm Fuel supply pressure Minimum fuel supply pressure, kPa (in H20): 1.5 (6.0) Maximum fuel supply pressure, kPa (in H10): 3.5 (14.0) Control system The PowerCommand® electronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, Precise frequency and voltage regulation, alarm and status message display, output metering, auto-shutddwn at fault detection and NFPA 110 Level 1 compliance. Sound attenuated enclosure The aesthetically appealing enclosure incorporlates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anti -corrosion performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads in accordance with ASCE7-10. The intelligent design has removable panels and service doors to provide easy access for service and maintenance. powencummine,com Average fuel consumption Fuel consumption — natural gas Load: 1/4 112 1314 Full FN/hr. 202.3 292.3 3ag3 472 3 M3/hr: 5.7 8.2 10; +32 Conversion factor: 8.58 ft3 =1 Ito 0.535m3 = 1 kg 36.39 113 = 1 gal Easy service and installation Removable Service Door Customer Access Door OwwI wltsftrVw. 02019 Cummum Ina I NAS-5777•EN (6119) A0520009 Fuel consumption— LP vapor Load: 1/4 1/2 314 I Full Ft3/hr: 79.8 114.1 148.4 1 182.7 M3/hr: 2.2 3.2 4.2 1 5.1 Gal/hr 2.2 3.2 14.1 5.1 Display Circuit Breaker Natural Gas/Liquid Propane Fuel Connection Air Cleaner Coolant Fill power.cummins.com Y i Basic dimensions till — all :w A UEr VE]r ra VM ICCr$S )COA FOR U:R O( EAPYCR OPiu UACJII ]A(IM1i R.xg0.[ ' I O Stint[ i1R(t uR I El"iOR E]ii IC1 PN(l --- 1., — ]91 19O i .� 1111� IL O A;t«ts Ir � LEFT SEE MEW\, Wilt PUR so 1]. r! 5[RY1C( Poll Note: This outline drawing is provided for general reference only and is not intended for use in design or installation. For more Information, see Operators and Installation manuals or contact your distributor or dealer for assistance. Automatic transfer panel configurations Typical service entrance ATS model Installation (100/200A) Typical non -service entrance ATS model Installation (100/200A) Dedicated emergency slandby service system (100/200A) OWUN awwYurtQ~ 02019 Cummins Ino. I NAS5777-EN 161191 A052G009 poxier.cummins.com I OOA RA Series Automatic Transfer Switch (ATS) Non -service entrance 200A RA Series Automatic Transfer Switch (ATS) Non -service entrance I OOA and 200A RA Series Automatic Transfer Switch (ATS) Service entrance QWWMWWWftMf4r~ 02019 GUMM Inc I NAS-BM-EN (NISI ADBROGag Power.cummIns.com Accessories • HMI21IRS in -home display, including Pre -configured 12-inch harness • HMI211 remote display, including pre -configured 12-inch harness • HM1220 remote display • Auxiliary output relays (2) • Auxiliary configurable signal inputs (8) and relay outputs (8) • Annunciator —RS485 • Internet monitoring device — PowerCommand 500 • Battery chargers —stand-alone, 12V • Enclosure Sound Level 1 to Sound Level 2 upgrade kit • Enclosure paint touch up kit • Base barrier— elevated generator set • Alternator heater • Maintenance and service kit • Engine lift kit Transfer switch (sold separately) • Automatic Transfer Switches available in various amperages. • Service Entrance models are also available, which helps reduce the installation cost. • All models UL listed to UL 1008 standard. • Available for both Indoor and Outdoor applications. • Compatibility with Cummins generator set helps reduce the installation time for the complete application. Warranty policy The Cummins RS and RX liquid cooled generator set models come with a 2-year base warranty when used in EPA -Stationary Emergency application. The RA series Automatic Transfer Switches come with a 2-year base warranty. Extended warranty options are available. Please contact Cummins dealers/distributors for details. After sale support e® Largest distributor/dealer support network Cummins Power Generation generator sets are supported . L by the largest and best trained worldwide certified distributor/dealer network in the industry. The network of knowledgeable and highly trained dealers will help you select the right generator for your application and advise you on associated accessories for your generator. The dealer f . 19 • network can also help answer any questions yo'lu may have regarding operation and maintenances requirements of the s�r.•W e.sef oc Maoubrers wwnvws.•esa.r•••.bu. a.wrm a^•�.•-�Fr.«sa.u� a..r.,am.wmr..wanrv,uv. tl.memen+wrmawnam4e.m „mew, • generators. This same network offers a compleFe of commonly used generator set maintenance selection mwbMnp•bwrybmRrN,bMb .aml.nWM+MrtmNtlG,pD>,wln mac+a•PPw.adww>.nws,aa,. m•N krvYvb•pn� parts, manuals and specification sheets. meatsnq a>mm•Mmer.s.,em. Manuals: Operation p Aeration and installation manuals ski with the generator set. To obtain additional copies or other manuals for this model, see your distributor/dealer. To easily locate the nearest certified distributor/dealer for Cummins generators in your area, or for more information, contact us at 1-800-344-0039 or visit power.cummins.comi Contact your distributor/dealer for more information. North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 OWN UNWA trgW � P"er 02019 Cummins Inc. All rights reserved. on Cumnuns Is a registered trademark of Cumrmrrs Ine 'Our energy woreng for You.' is a trademark of Cummins Power Generaean. Other company, product, or service names MY be trademarks or service marks of others. Specifications are subject to Mange Mthout notice. NAS-57rr-EN (e119) A052GO09 Specification sheet FILE COPY RA series Transfee� gaches SCANNED BY Lucie County BLDG: DATE: ELE - DATE; 22,/q PLUMB: DATE: MECH: DATE: The RA automatic transfer switch is integrated with the IRS series generator set. These products are listed to UL 1008, the Standard for Transfer Switch Safety. The switch and generator set combination is specifically designed for a simplified, quicker installation. These UL 1008 switches are suitable for Standby power systems in residential and light commercial applications. These RA products adhere to National Electrical Code (NEC) and National Fire Protection Association (NFPA) requirements. The RA transfer switch monitors utility power 24 hours a day and 7 days a week. When utility power becomes unsatisfactory or fails; the generator set is signalled to start, then automatically transfers the load. When stable utility voltage returns, the transfer switch will automatically switch the electrical load from the generator to the utility. The homeowner requires no action. The RA switch is also available in service entrance models. A service entrance version is also UL 1008 listed and makes use of a UL 489 listed circuit breaker. 1 o0A and 200A service entrance switch is certified under CSA 22.2. Our energy working for you: C2018 Cummi. 1. 1 NAS5 1FN (MIS) Features GvF Mechanically interlocked contactor • Long -life, high pressure, silver alloy contact resists burning and pitting • A powerful and economical solenoid drives the mechanism UL 489 Listed circuit breaker Solid bus bar connection • Between circuit breaker and transfer switch Neutral and ground bar • Fully rated • Bonding jumper on neutral and ground • Silver plated copper ground and neutral bus Ease of connection • Solderless screw type terminals for external power connections power.cummins.com 1 Transfer switch mechanism • A powerful and economical solenoid powers RA Transfer Switches. • Independent break -before -make action is common for 2- pole. • Mechanical interlock prevents simultaneous closing of normal and emergency contacts. • Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. • Long -life, high pressure, silver alloy contacts resist burning and pitting. Contacts are mechanically held in both normal and emergency positions for reliable, quiet operation. Specifications Voltage rating Transfer switches up to 240 VAC, 50 Hz or 60 Hz. Amperage rating Transfer switches rated for 100, 200 and 400 A Continuous amperes. Arc interruption Multiple leaf arc chutes cool and quench the arcs. Barriers prevent interphase flashover. Neutral bar A full current -rated neutral bar is standard on enclosed 2-pole transfer switches. Auxiliary contacts Two contacts rated at 5 A Continuous at 100 VAC or 2.5 A Continuous at 200 VAC (one for each source) are provided for customer use. Wired to terminal block for easy access. Storage temperature -25 °C (-13 °F) to 55 °C (131 °F) Humidity Up to 90% @ 20 °C Altitude Up to 2,000 m (6,561 ft) without derating. Total transfer time (source -to -source) Will not exceed 100 m/secs with normal voltage applied to the actuator. Manual operation handles Transfer switches are equipped with a removable operating handle which allows operation during servicing in order to facilitate troubleshooting with sources of power disconnected. Our energy working for you. power.mmmins.mm 02018 C..i. Ix 1 NAS3WD EN (W18) UL 1008 withstand and closing ratings Transfer switch ampere Coordinated molded case breakers 100A 22,000 200A 22,000 100ASE 10,000 200 A SE 10,000 400A 35,000 400 A SE 35,000 Enclosures Wire bend space complies with 2013 NEC. Dimensions -transfer switch in UL type 3R enclosure Model and Height Width Depth Weight Amp rating in. mm in. mm in. mm lb kg Outline drawing 100 A 24.0 619 17.0 433 7.4 187 33 15 A04411213 200 A 27.1 688 18.2 463 7.4 187 46 21 A04411213 100 A SE 23.3 591 19.8 503 7.2 182 58 26 A04411213 200ASE 23.3 591 19.8 503 7.2 182 58 26 A04411213 400 A 36.9 937 24.9 633 11.1 282 64.5 29.3 A049Z141 400 A SE 47.9 1217 23.4 594 11.3 287 95.6 43.4 1 A049ZI41 Transfer switch lug capacities Model and Amp rating Size 100 A #14 AWG to 2/0 CU/AL 200 A #6 AWG to 300 MCM CU/AL 400 A 310 to 600 MCM and #4 to 250 MCM Service entrance transfer switch lug capacities Model and Amp rating Size utility Load, neutral and generator Ground 100 A SE #4 AWG to 300 MCM CU/AL #14 AWG - 2/0 CU/AL #14 AWG -1/0 CU/AL 200 A SE #4 AWG to 300 MCM CU/AL #6 AWG - 300 MCM CU/AL (transfer switch and neutral only) #14 AWG - 2/0 CU/AL (generator) #14 AWG -1/0 CU/AL * 400 A SE #2 to 250 MCM 310 to 600 MCM #6 to 310 2 Submittal details Description Part Rating Voltage Enclosure RA112N3 A045P692 100 A 1201240 V 1 phase 311 RA212N3 A045P694 200 A 1201240 V 1 phase 3R RA112S3 A045P696 100 A SE 120/240 V 1 phase 3R RA212S3 A045P697 200 A SE 120/240 V 1 phase 3R RA412N3 A050W633 400 A 120/240 V 1 phase 3R (Aluminum) ( RA412S3 A05OW853 400 A SE 120/240 V 1 phase 3R (Aluminum) Our energy working for you.- power.cummins.mm 02018 CmmIm I NASWIMN(0418) Certifications Ue All switches are UL 1008 Listed with UL Type Rated cabinets and UL Listed CU-AL terminals. All switches comply with NEMA ICS 10. noAll switches comply with NFPA 70. NFPX Ae All switches are CSA 22.2 certified. For more information contact your local Cummins distributor IdNEWSM or visit power.cummins.com Our energy working for you.' rM. W018 Cummins Ina M rigtr5 reserved. Cummins is a 2gjSt nxi trademadr d Qonmins Inc PwrerCammanQ AmpSedry, In r ond'W eneWv orking for you' ere trademadu of Cummins Ina Otho,. .product, or service rames may lie trademarks or"Mce mans dd,m. Spedficafions are m jed to tl ngevriN notm NAS5810EN (MIS)