HomeMy WebLinkAboutPLANS.DESIGN CRITERIA: 'APPLICABLE CODES REGULATIONS & STANDARDS tL 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SET 7 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY. PARAGRAPH 1609.4.3: D 3. WIND LOADS PER ABC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = D FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 51 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 40 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 14 PSF VERTICAL PRESSURES ON SOLID SURFACES = 42 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 9k8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE. REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: c. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: 1. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 N. AIR ENTRAINING +/- I %- ASTM C 260 iv. WATER REDUCING AGENT -ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: L REINFORCING BARS -ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC -ASTM AI85 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. I. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW TOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. N O ALUMINUM SPECIFICATIONS ALUMINUM MEMBERS DIMENSIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. HOLLOW SECTIONS ui 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH 2 x 2: 2x2'k0.044" a �' .r #12 SCREWS b" FROM ENDS & 24" CENTER TO CENTER. 2 x 3: 2"x3'k0.050" w N 3. ROOF BRACING SHALL BE A MINIMUM 2'X2"X.050". 2 x 4: 2"x4'k0.050" 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS 2 x 5: 2"x5'k0.050" v a (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 ` „y INCHES. OPEN BACK SECTIONS V C9 ^� 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN 1 x 2: 1'k2'k0.044" w WIND SPEEDS EXCEED 75 MPH PER FBC. 1 x 3: 1'k3"x0.045" �' UJ 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. SNAP SECTIONS 10 c 5. 1"X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED 2 x 2 SNAP: 2'k2'k0.045" INTERCHANGEABLY. 2 x 3 SNAP: 2'k3'k0.050" 2 k 4 SNAP: 2'k4'k0.045' 1 0 in FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1 /2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE 4 SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST ) A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1/2"SMS OR TEK) SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE I"X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING' REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. i MISCELLANEOUS I 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. } IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH '. WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO,,' ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK W/3000 PSI N GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. ' 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"x4"x0.044'k0.100' UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW' MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" ' FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTPIALLY SOUND. i SELF MATING (SMB) 2 x 4 SMB: 2x4"x0.044'k0. 100" 2 x 5 SMB: 7k5'k0.050'k0. 100" 2 x 6 SMB: 2'Sc6k0.050'k0. 120" 2 x 7 SMB: 2'k7'k0.057x0.120" 2 x 8 SMB: 2'k8"x0.072"4.124" 2 x 9 SMB: 2'k9"x0.082"x0.124" 2 x 10 SMB: 2'k10"x0.092"x0.398" DETAIL A SCANNED BY St. Lucie County REVIEWE CODE CONIIANCE ST. LUCIE COUNTY BOCC OEC 0 9 tots FILE COPY 8'-6" ------- 1X2 2X3 DJ 2X3 DJ (4 r N x N 1XZ T 8 00 1 I. HAND -RAILS SHALL BE DESIGNED IN ACCORDANCE WITH FBC 6TH EDITION )2017) SECTION R311.78; 2. GUARD-RAILS SHALL BE DESIGNED IN ACCORDANCE WITH FBC 6TH EDITION SECTION R312 1p 4 PER PAGE-3 VIVI RESIDENTIAL GUARD RAIL DETAIL SCALE: N.T.S. HOST 24" O/H 3" X .024" X 1LB COMPOSITE PANELS 3003-H154 1/4"-1' SLOPE (MIN.) (FL.# 7561.1-R4) W a a C c '~ m N Ti2m) 6 MATERIAL LEGEND: 0 F X 1"X.044" PICKET) 2" X3" X.050TOP RAIL 2'X 2"X.050'POST U r• N J O En IX2 INSTALLATION NOTES: J r 0 I -FASTEN PERIMETER TO ALUM EAVE RAIL W#12X 1-1/2 SMS co -2X2 SMS TOP CAP 24"O/C AND WITHIN COF INTERSECTING MEMBERS AND JOINTS. - (h 2-FASTEN PERIMETER TO MASONRY WI/4"X2-1/4"OUICKSEi 24" O/C AND WITHIN 6' OF INTERSECTING MEMBERS AND JOINTS. Z Q O 0: SO TUBE WALL PICKETT PICKER 8 POST ASSEMBLY NOTES: U U U .04C ZED TO REJECT 4" SPHERE 1-FASTEN CHAIR RAIL (INTERNAL)TO PERIMETER W/)4) #IOXI-1/2' U �" SMS INTO SCREW BOSS OF CHAIR RAIL. 2-FASTEN PERIMETER MEMBERSAT CORNERS(INTERNAL) W (2) .-I Lij O Q pp — ,OST 'OST # X OSSES. SMS INTO SCREW BOSSES. i� F EN PI 1/2"SMSTHROUGH PNGM W Q Lo •C 'OPEN INTERSECTING IMERSECTING MEMBER INTO PICKEITS MEMBER RINT PICK BACK SEE FIG I Z L.L ROM CHANNEL � W � GENERAL NOTES D SPECIINDICATED / n m ERINA STRUCTURES I AREDESIGNED T INSTALLED 1-THE STRUCTURES INDICATED _ V •� EBE FRAM WITHI N MASON RY OR WOOD FRAME HOST STRUCTURES OFTHAT 0 r STRUCTURAL THEH CAPACITY. THE CONTRACTORSHALLSUFFICIENT VIENTTRENGT HOST Q J N I GOOD PROPOSED N. OF SUFFICIENT STRENGTH TO SUMINUM HE PR ADDITION. OSED ADDITION. W 0 SI STRENGTH REQUIREMENTS INUM EXTRUSIONS < Q OF ASTM B221MIN AFTER POWDER COATING. OFAST ERGOMEET COATING. 3-ALL ALUMINUM EXTRUSIONS ARE TO BE MINIMUM 6063 T6 r1 Q 2X7SMB C.B. 0 N 1X2 2X3 DJ 2X3 DJ _ N X Tom' 1X2 " PICKETS 4" O.C. � 024 F�SHING SEALED TO WALL TYE.) �LL IT #I 4xI /Z'S.M.S. W1 INTEGRAL 3/4 OWASHER AND 0 NEOPRENE GASKET 0 12'O.C., TOP & BOTTOM. 0 IF CLEARANCE PROHIBITS INSTALLATION OF TOP FASTENERS USE #14x4'SM.S.Wl 1-114 0 FENDER WASHER AND NEOPRENE GASKET @ 12'O.C. EXTRUDED OR BRAKE -FORMED ROOF HEADER 0 0 R RECEIVING CHANNEL (0.04N' MIN. THICKNESS) WITH MIN. 1-112 BEARING LEG. HOST STRUCTURE 1/4" 0 x 2-1/2'LONG WOOD �G SCREW OR MASONRY OR WOOD 114'0 x 2-1/4'LONG MASONRY ANCHORS @ 24" O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. EX "IN 0, TRU INI PRENE GASKET BOTTOM FORMED ROOF H SECURE FASCIA TO EACH RAFTER TAIL W/ (1) 1/4" 0 X 4" LONG PAN HEAD LAG SCREWS \_.(U 1 /�'O x 2'l-AG SCREW @ 24" O.C. BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL ROOF PANEL ATTACHMENT - WOOD FRAME SCALE: N.T.S. U ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL �/(4) #10IL75 INTO GIRT OR PURLIN & (2) 414.75' (4) #10XIA/2'sms INTO INTO BEAM OR UPRIGHT 0.062 ANGLE SCREW BOSSESJ CUPS MAYBE USED PURLIN MEMBER OR DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS 1/6X2X2XANGLE (2) - 412 SMS INTO COLUMN 5032 H-32 ANGLE ANGLE - EACH SIDE COL. 11W'MASONRY ANCHOR EACH 3000 PSI CONC. SI-AB/ FTG 6X&10.10WWi� OR ABERMESH 1/4'MASONRY ANCHOR AT EACH ANGLE 2-1/4'MIN. CONC.--\ ANCHOR EMBEDMENT O.B. BASE PILATE-TYP. 1-1/4'MIN-CONC. ANCHOR EMBEDMENT SIDEVIEW (2) - 912 SMS 2'MILU INCREASE DISTANCE WHEN GREATER THAN 2X4 UPRIGHT IS USED HEAD MFG. OR EQUAL) ROOF PER PLAN # 144" SM.S. W/ 1-114'0 FENDER WASHER AND NEC-PRFNE GASKET 0 12' O.C. # 12 X 9/16!'W/ 516'NEO-WASHER (3) PER PAN FOR PANS EADER THICKNESS) COVER END OF PANEL # 14x,F'S.M.S. wl 1-1/4" 0 FENDER WASHER AND NEO-PRENE GASKET 0 12'CC. # 12 X 9/16*'W/ 5/9'NEO-WASHER (3) PER PAN MR PANS COVER END OF PANEL CARRIER BEAM (SEE PAGE-2 FOR SIZE) ALTERNATELY (4) # 10 INTO SCREW BOSS OF UPRIGHT 2 MIN. POST 'OPTIONALEXTRUDED GUTTER IS ATTACHED TO 3 INSULATED ROOF W/#I 2xl' 6'FROM ENDS 24'O.C. POST TO CARRIER BEAM CONNECTION SCALE: N.T.S. 4 1'5C'BASE PLATE ANCHORED TO CONC �/ I /,f* MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24"O.C. MAX 1-1/4' CONC. EMBEDMENT TYP. 3000 PSI CONC e NOTE SLAB/ FTE. f WHERE PAVERS ARE PRESENT USE 5116' L� TAPCON XL (RED HEAD MFG.) MASONRY 6x6- I Oxl 0 WWM FRONT VIEW ANCHORS TO PENETRATE UNDERLYING OR FIBERMESH CONCRETE FOOTING 2-114� (MIN.) DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS -ANCHORING UPRIGHT TO FOUNDATION NOTES: l.- IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-1/4" MIN. (TYP.) 2.- WHEN FASTENING TO WOOD USE 1/4" GALV. LAG SCREW IN LIEU OF CONIC. ANCHORS AND ENSURE 2-1/4" MIN. PENETRATION INTO STRUCTURAL FRAMING BENEATH (TYP.) .3, NO SECONDARY ANGLE REQUIRED FOR 2X3 UPRIGHTS OR DOOR JAMBS. 2-X2'XI/VANOLE UTTOFIT WjRN.N"f.C..G__� �Cll SIDE OF UPRIGHT TflP. SEEUPRIGHTTODECK CORRECTION DElWt_\\ 3'X Z'X.05U'MIN. (SEE PLAIN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. 0 0 CARRIER BEAM 0 PER PLAIN 0 0 0 0 CARRIER BEAM 0 PER PLAN MAY USE: (2) 3/3'DIA. MACHINE BOLTS THEO REC. CHANNEL & BEAM IN UEU OF #14 SMS BEAM TO COLUMN CONNECTION DETAIL SCALE: N.T.S. PROM DED 2'X2-XlJ8'ANGLECUTTOFff SPACING MAY BE REDUCEDTO w/N) 412,75E EACH SIDETYP. 24' FOR NONLOAD BEARING WALLS ALTERNATELY CLIPS MAYBE USED 1/4- DIA. TAPCON RE FROM ENDS DENNALLUNRIGHT 24' O.0 WX 1-114"EMBEDMENT /�PRIIAARYUIUGHTPIRPLAN /s, PER PLAN INTO UNDERLYING CONIC. ALUMINUM INTERNI OR EXETERN�L RECENING CHANNELW/N) 410N.75' INTO GIRT OR PURUN & (2) 914X75- (4) #l0x2' SKIS INTO INTO BEAR OR UPRIGHT 0.062 ARGUE SCREW 8OGSEl WPS MAYBE USED CHNR PAL PER PIOUN 'ANGLE REQUIRED ON E SIDE ON AT DONNER AND DOOR OPENINGS WHERE KICK PLATE 15 INDICATED MSTENW/#IOX9/16'SMS R)#10x2'WSINTO 1/4' DIA. TANCON RE FROM ENDS 2' FROM CORNERS S' IN FIELD SCREW BUSSES OR MAKI-V4-EMBEDMENT CLIPS WY BE USED ,,,,,.24'OC NI DERDING CONC. FOUNDATION PER PLAN SCREEN ROOM END WALL DETAIL SCALE: N.T.S. 0 0 ROOF PER PLAN # 14x4" SM.S. wl 1-I W 0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. # 12 X 9116' W/ 5/8" NEOWASHER (3) PER PAN FOR PANS END OF PANEL �-3' X 2' X A50' MIN. (SEE PLAN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. ROOF PER PLAN #14xf'S.M.S. W/ 1-1/4'0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. # 12 X 9/16' W/ 5/8' NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL CARRIER BEAM CARRIER BEAM 0 CARRIER BEAM (SEE PAGE-2 (SEE PAGE-2 (SEE PAGE-2 FOR SIZE) FOR SIZE) FOR SIZE) 3/8DIA. MACHINE (2) 3/8" DIA. MACHINE (2) 3/8' DIA. MACHINE ILTS THRU CARRIER BOLTS THRU CARRIER BOLTS THRU CARRIER 4M & POST BEAM & POST Fp BEAM & POST BEAM TO POST CONNECTION OPTION #2 SCALE: N.T.S. POST BEAM TO POST CONNECTION OPTION #2 SCALE: N.T.S. MAY USE (4) #14xl"TEK TOP VIEW IN LIEU OF THRUBOLTS (3) 1/4" DIA. MACHINE OF POST 'OPTIONALEXTRUDED GUTTER IS ATTACHED TO 3'INSULATED ROOF W/# 12 0"6" FROM ENDS 24" O.C. POST TO CARRIER BEAM CONNECTION SCALE: N.T.S. MAY USE: (4) 3/9 x5' TAPCON IN LIEU OF 1/2" DIA. BOLTS I" (2) 1/2' DIA. EXPANSION BOLTS (3) 1/4" DIA. MACHINE 1 SEE NOTE #2 THIS PAGE ® ® BOLTS W/ WASHERS 2. FOR BOLT PLACEMENT I 3-3/4' FROM EDGE--[33/4" FROM EDGE OFSLAB/FTG. OF SLAB/FTG. (3)1/4"DIA. MACHINE BOLTS w/WASHERS TOP VIEW -COLUMN PER PLAN N'x4. POST POST -I/9',qX 3-3/4" (2) 1/2'DIA. EXPANSION (2) BOLTS SEE NOTE #2 THIS PAGE FOR BOLT FOR(SEE FOR SIZE) MAY USE (4)#14x1"TEK (LENGTH) ANGLE PLACEMENT IN LIEU OF THRUBOLTS (INTERNAL) �2k4'k0.125 ANGLE 3D00 PSI CONC. ``,• �. SLAB/ RG. ' 6x6-10x10 WWM OR FIBERMESH FRONT VIEW 4X4 COLUMN ALT. BASE ATTACHMENT DETAIL SCALE: NTS 3000 PSI CONC. _ SLAB/FTG. 6x6-IOxIOWWM �• .� OR FIBERMESH FRONT VIEW 4" M" POST CONNECTION DETAIL SCALE: NTS