HomeMy WebLinkAboutDESIGN LOAD COMPLIANCE CERTIFICATE1
Project Name:
Project Address:
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Castle pylon sign
3525 W Midway Rd., Ft. Pierce, FI
Permit#: Occupancy Type: Construction Type:
SCANNED
By
Sr. Lucie County
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida X Code 2010 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open
3. Risk Category: X 1 _II _III —IV Exposure Category: _B X C _D
4. Design Wind Velocity 150 mph X ASD _LRFD End Zone Width: N/A ft
5. Mean Roof Height <20 ft Roof Pitch: N/A :12 Parapet: N/A it
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -71 Zone 2: -71 Zone 3: -71 Zone 4: -71 Zone 5: -71 Garage: -71
7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? N/A Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the Wlicablef§yuctural portions of the building codes currently adopted and enforced by St. Lucie
County. I a4 tpl elements depicted on these plans provide adequate resistance to the design
forces sp2ccl E N S f' •. O 4°
John J.Orlando
��°•. SIPJE O :
Signature'�g
SLCCDV Form # 020-12 Wised 3/15/12 (JS)
Print Name
John J. Orlando PE LLC
Company Name & Address
0044089
Cert # & Co. Cert Auth.