Loading...
HomeMy WebLinkAboutMISC EMAILJeffrey D. McGee, P.E. Structural Engineer, FL PE #45944 PO Box 12964 Fort Pierce, FL 34979 March 17, 2014 St. Lucie County Permitting Department 2300 Virginia Ave. Fort Pierce, FL 34982 SCANNED BY St. Lucie County RE: Hibiscus I, 3870 A1A, Ft. Pierce FL Garage Door Replacement, West Garage Building To Whom It May Concern: Phone: 772-971-6435 email: engmcgee@gmail.com FILE. COPY I understand the garage doors at the above reference building are proposed to be replaced with the system listed below. The garage building structure is reinforced CMU walls with wood roof trusses. The garage door openings are 7'-0" high and less than 9'-0" wide. Garage Door: Wayne Dalton Model 8700, Code Option #1002 Florida Product Approval, FL 12099.3 Design Parameters: Wind Speed: ASCE 7-10, Risk Cat. II, Veit= 160 mph (3 sec.), Vnd= 124 mph, Exp. Cat. D, Directionality Factor Kd=0.85, Mean Roof Height: 15 feet, Kh=1.03, Edge Zone Width = 5.6 feet Garage Door Design Pressures, P4/P5= +36.5/- 45.8 psf, based on 50 sf trib area, (Note these pressures are ASD) The installation of the door system including track, clips and attachment to wood bucks and building substrate shall be in strict accordance with the reference Florida Product Approval. I have reviewed the Wayne Dalton garage door product approval and I approve their use in this structure. Please contact me if you need additional information. Sincerely: 20/9- Jeffrdyb.McGee; PE FL PE #45944 Attachments: SLC Wind Load Cert Form, SLC Product Review Affidavit, FL PA #12099.3 SAFETY 9 QUALITY 9 SERVICE