HomeMy WebLinkAboutPLANSSCANNED BY St. Lucie County Wayne -Dalton, a Division of Overhead Door Corporation One Door Drive, PO Box 67, Mt. Hope, Ohio 44660 4/3/2014 RE: Wayne -Dalton Model 8700 Windload Option Code 1002 and Low Head Room Track Wayne -Dalton Quote 1795349,'Hibiscus Condominium Building #1' To Whom It May Concern: This letter concerns the Florida Building Code (FBC) Windload Approvals that Wayne -Dalton, A Division of Overhead Door Corporation, has for the Model 8700 residential garage door (FL-12099). The FBC Approvals for Wayne -Dalton residential garage doors can be viewed at: www.floridabuildina.oro. The Model 8700 is approved per FL-12099. The garage door sections are made with PVC exterior substrates and interior substrates with polyurethane foamed -in -place insulation, for a unitized body construction and superior corrosion resistance. The Wayne -Dalton FBC approval (FL-12099) for our Model 8700 door includes 'Standard Lift' garage door track. This windload certification does not list'Low Head Room' track since the 8700 windload door testing was not conducted with 'Low Head Room' track. Low Head Room track is a standard option for the 8700 door, and is listed with several other Wayne -Dalton Models per FBC approvals FL-8248, FL-9166, and FL-9174, including Wayne -Dalton Models 8000, 8024, and 9100. The Model 8700 door uses the same construction of Low Head Room track as these other Wayne -Dalton Models, and it is my judgment that Model 8700 Windload Doors per Option Code 1002 will meet the same windload performance with Low Head Room track, as it does with Standard Lift track, to withstand Design Pressures of+41.0 /-46.3, per Wayne -Dalton Quote 1795349. Respectfully, 1Sway.,u. 9CmronieR. Dwayne Kornish Professional Engineer, State of Ohio License Number 74013 Engineering Manager Wayne -Dalton, a Division of Overhead Door Corp. One Door Drive, Mt. Hope, OH 44660 407-856-0073 Orlando fax 407-468-4332 Cell Wayne -Dalton Website Genie Website CONFIDENTIALITY NOTICE: This e-mail (including any attachments) is for the sole use of the intended recipient (a), and It may contain private, confidential or privileged Information. If you have received this e-mail in error, you are not authorized to copy, disclose or use it, so please delete it from your system and notify the sender by reply e-mail. VOTES. 1. GLAZNG OPRON - .125' MINIMUM SSE GLAZING IN MMDEO FRAMES SCREWED TOGETHER WITH A MINIMUM OF (12) 1] GA HOME ANGLE /'Ba]/4' SCREWS INSTALLED IN TOP OR INTERMEDIATE SECTION (MM OR WITHOUT DECORATIVE INSERTS) MEETS UNIFORM 13 CA FLAG ANGLE STATIC WIND PRESSURES SHOWN ON THIS DRAWING. GLAZING SHALL HAVE A MAXIMUM 16 GA AN HERTZ HEIGHT OF 14' AND A MAXIMUM LENGTH OF MAN 17'. MA G IS NOT IMPACT RESISTANT AND DOES NOT MEET ME REQUIREMENTS 5/I6al-5/8' FOR MO -BORNE DEBRIS REGIONS LAG SCREWS (MIN 4 AS SHOWN) 2. MY- OR WOOD DOOR STOP NAILED A MAXIMUM OF 6' O.C. MUST OVERLAP TOP (4) 1/4-20a9/16' AND BOTH ENDS OF PANELS MINIMUM TRACK BOLTS 4: 7/I6' TO MEET NEGATIVE PRESSURES. 1/4-20 HEX NUTS 3. KEY LOCK, SLIDE LOCK, OR OPERATOR 1/4-204/16' TRACK REQUIRED. BOLT AND 1/4-20 HEX NUT AT EACH v8-US 4. SECTIONS SHALL BE CONSTRUCTED WIN JAYS BRACKET LOCATION .052' MINIMUM MY. FACER AND .032' MINIMUM MNYL BACKER WITH A 15 CA MIN VERT POLYURETHANE CORE. TRACK 5. SECTIONS SHALL HAYS 1-1/4' a 1-1/2' 22 GA CONTINUOUS INTERNAL RAILS AT THE TOP AND BOTTOM OF EACH SECRON. LAC LAG 5/IfiA-5/8' THE ENDS OF EACH RAIL IN ME TOP OF SCREW AT ACH EACH SECTION SHALL BE REINFORCED MTH JAMB BRACKET A 15 6A REINFORCING BRACKET. S. SECTIONS SHALL HAYS 20 CA BACKUP ELATES AT ALL INTERMEDIATE HINGE 15 GA STIFFENED LOCATIONS. JAMB BRACKETS SEE SCHELOULE FOR ). ME DESIGN OF ME SUPPORTING DDANITY, TON, STRUCTURAL ELEMENTS SHALL BE ME AND TYPE AND IUTY OF THE 1 OF RECORD OR RECORD F THE BUIIIDNG OR SMUCMRE NG STRUCTURE KEY LOCK d SLIDE AND MIN PCODES FOR ME CURRENT CC CODES FOR ME LOTUS USIED d LOCK ONE ENO NOT (WITH MISDR MI5 DRAWING, REQUIRED OPERATOR -SEE U. JAMB SHALL BE MINIMUM 2.6 NOTE ]). AIDE LOCK U SIiRICTUCNRAL (BADE LUYflFR. PFFFR TO SHOWN FOR aMln. NOTE: (4) SECTION SOUR DOOR SHOWN. SEE SHEET 2 FOR U-BM LOCATIONS FOR (5) SECTION Dams AND NOTE I ON MSS SKEET FOR GLAZING OPTION. SUPERIMPOSED DESIGN PRESSURE LOADS ON SUPPORTING STRUCTURE NA% ODOR HOR D.. UNIFORM LOAD EACH JAMB (PLR) MDM B'-0' ALL +166.4/-185.2 9'-0 I ALL 1 ♦I67.2/-208.4 GA END CAP JAMB BRACKET SCHEDULE DOOR NpdT N0. 6 SECTIONS ANIJ BRACKETS (EACH JANE) l A GN ry LW JAM" BRACKETS MEASURED MOM BOTTOM OF MAN (ALL DIMENSIONS + 2') 6'-6' ♦ ) 2 JB-US. 10 M-U5. ]I-] 4 .®-U5. ]9-3 4 JB-U5. 39 JB-US). 48 JB-U5. 5)-1 4 Jd-US 29-J 4 JB-US. 92 .B-US. 52-1 2 JB-US, fi3-1 4 �@-US -6' S B 2 JB-US, 10 JB-09, 18-5 4 JB-US. 26-J 4 JB-U5 ]fi JB-US. 45 J.-U.. 54-1 4 ✓H-US 14-1 2 JB-US J - 9 NOTE. (.B-US) FOLLOWING DIMENSION DENOTES SLOTTED JANE BRACKET ATTACHED TO TRACK WITH 1/4-20a9/I6' MAN EMT AND NUT AS SHOWN ABOVE. ALL DOORS GREATER MAN S' IN HOGHT REQUIRE USE OF CONTINUOUS WALL MGLE. SEE SUPPLEMENT MAN CHART FOR DETAILS. DOOR HEIGHT TO 14'. DOOR ADDED TEXAS ICENSE NUMBER TO TILE BLOCK. 10/30/08 CRT ��J ® --+41.60/-46.30 MAX WIDTH:„u 9'-0','DATE ,aNAME YY palton +62.40/-69.45 MAX HEIGHT: 14'-0' DRAWN 7/27/07 CRT C RATED (YES/NO): NO MAX SECTION HEIGHT: 21' CHECKED 8/1/07 MNB rWIND!LOAD MODEL 8700 SHEET 1 OF 2 MARK ICR. BARROW, 7 FLORAS LICENSE N0. 57389 3395 ADDISON DRIVE DRAWING PART NO. REV. TEXAS LICENSE N0. 93119 PENSACOLA, FLORIOA 32514 (850) 474-9890 SPECIFICATION OPTION CODE 1002 329474 P1 2' STEEL ROLLERS MM 5-1/8- STEM 14 CA WDE BODY END KNGES ATTACHED WITH 14 CA BOTTOM BRACKET CTTACHED WTH f21 DETAIL C DETAIL D MARK R. BARROW. PE FLORIDA UCENSE NO. 57389 TEXAS LICENSE NM 93119 /NIERMED/AIE H/NZ AND OAC/fUP PCATE CDCARDNS 1 8' 8 9' U-BAR LOCATIONS (8) SECTU (12) 3' 20 CA ( LOCA (7) SECTION DOOR! (11) 3- 20 CA 80 KS U- LOCATED AS ; (6) SECTION DODRS WITH (9) 3' 20 GA 80 KS U-BARS LOCATED AS SHOWN (5) SECTION DOORS WTH (8) 3- 20 CA 80 KSI U-BARS LOCATED AS SHOWN (4) SECTION CODRS PATH (6) 3' 20 CA 80 KS U-BARS\ NOT - U-BARS LOCATED ON TOP OF THE SECTION SHALL BE PLALFp ON TOP OF THE BOTTOM HINGE LEAFS AS SHOWN (NOT MP CABLE TO TOP SECTION) a Balton 3395 ADDISON DRIVE HEIGHT TO 14'. TEXAS ;E NUMBER TO BLOCK. /08 CRT MODEL 8700 SHEET 2 OF 2 DRAWING PART N0. REV. WINDLOAD SPECIFICATION OPTION CODE 1002 32g474 P1 _ REVISIONS Q 13 GA MIN %P2 2 INCH TRACK -CUPS -TEXAS WAM ANGLE 12 FOOT Q CONTINUOUS / J��TRACK UPDATED WALL ANGLE �� Bpi 6/I1/03 PLICE PLATE LOCATION I P3 UPDATED FORMAT. INCREASED AVOWABLE J o SEE SCHEDULE f — — j PRESS1 .46.00 /52.RES TO -5 1 O° AM DOOR PSF FOR ALL ODOR TS 11 GA MIN . \ CHANGED 'TEXAS WALL CLIP SEE. (3) 1/4"-20 TRACK ANGLE" TO'CONTINUOUS 14 SCHEDULE \ i! OR CARRIAGE BOLT WALL BUBSTRATEEMOUNTI G MAXI �' WITH 1/4"-20 NUT DETAIL, CHANGED TO TITEN HD ANCHORS CRT 4/2/07 TYPICAL CLIP P4 CHANGED FORMAT. BOLTING DETAIL ADDED MODELS 9800 AND 8024 WITH OVERLAY 13 GA MIN — TO TRACK CLIP CONTINUOUS �' SCHEDULE. WALL ANGLE TRACK CRT 8/21/07 P5 UPDATED MODELS 12' (2) 1 /4" X / � LISTED IN CHARTS UPDATED SPUCE & ClipMAX 7/16 SEMI j \ SacouLEs. TUBULAR _ _ 1 DIP 9/06/07 P6 UPDATE MOUNTING RIVITS 1 0° DETAIL DRAWINGS. 12" SEE CLIP DETAIL CRT I DRAW7 [7.�. :(1) 1/4"-20 TRACK MAX 11 GA MIN '� / P7 UPDATED T CHARTS TO EM / CLIP SEE OR CARRIAGE BOLT ELIMINATE THE USE OF \, THE ®0 CLIP (REPLACED SCHEDULE / WITH 1/4"-20 NUT WTR g9 Acaoss THE 12" 1`� D i, TYPICAL CLIP BOARD). P 10/24/07 1 MAX RIVETING DETAIL MOUNDINGATED J-TII NRB DING DETAIL P9 EXPANDED 1-1/2- TO 1-3/8' DOOR THICKNESS 12 CLIP LOCATIONS RSW 0.28" 11 GA MIN CLIP CHART UP TO 14' HIGH. MAX SEE SCHEDULE 2 �/tTRACK SEE SCHEDULE CRT 12/11/08 i(1) 1/4"-20 TRACK MAX TRACK 13 GA MIN NOR CARRIAGE BOLTCONTINUOUSWITH1/4"-20 NUT WALL ANGLE CLIPS TO BE EITHER TYPICAL CLIP RIVETED, BOLTED, OR WELDING DETAIL WELDED. SEE DETAILS THIS PAGE. Wagner DATE NAME YY 00�� DRAWN 8/21/07 CRT CHECNEO eI OF MRB SHEET 1 OF 2ADDISON DRIVE DRAWING PART NO. REV. MARK R. BARROW, PE TRACK SUPPLEMENT CHART PENSACOLA, FLORIDA 32514 FLORIDA LICENSE NO. 57389 (850) 4]4-9890 307494 P9 DESIGN PRESSURE CHART MAX MAX PSF WIDTH 9'-0" +46.0 PSF/-52.0 PSF 16'-0" +46.0 PSF/-52.0 PSF 18'-0" +46.0 PSF/-52.0 PSF 2 3/4" t1" EDGE DIST 5/16" x 1-5/8" LAG SCREW OR EQUIVALENT INTO MIN 2 x 6 NO.2 SPF (G=0.42) OR MIN 3/16" THICK STEEL FOR MOUN E60XX MINV BETTER AT EACH `i/4-20j BOLT HOLE OR PAIR 0� TRACK BOLT AND HOLE LOCATIONS 1/4-20 HEX NUT MOUNTING TO WOOD JAMB DETAIL MOUNTING TO STEEL DETAIL 2 3/4" OPTIONAL: WALL ANGLE MAY BE MIN EDGE DIST ATTACHED TO SUPPORTING STEEL n WITH MIN. (1) 1/4-200/8" SELF DRILLING SCREW WITH 1" O.D. WASHER AT EACH HOLE OR PAIR OF HOLE LOCATIONS IN LIEU OF WELDIN( a. e 3/8" SIMPSON TITEN HD, 2-3/4" MIN EMBED INTO MIN 2000 PSI CONCRETE AT EACH HOLE OR PAIR OF HOLE LOCATIONS WALL ANGLE -1/4-2Ox9/16" TRACK BOLT AND 1/4-20 HEX NUT TRACK CLIP MARK R. BARROW. PE FLORIDA LICENSE NO. 57389 CLIP AND SPLICE PLATE SCHEDULE MODELS 8024 8124 WITH DECATRIM OVERLAY (2-1/2' THICK DOOOFR CLIP #'S FROM BOTTOM TO TOP SPLICE LATE# 7'-0" 7, 9, 9, 9, 9, 11 16 8'-0" 7, 9, 9, 9, 9, 11, 11 16 9'-O" 7, 9, 9, 9, 9, 11. 11, 11 18 10'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13 18 11'-0" 7, 9, 9, 9, 9, 11. 11. 11, 13, 13 20 12'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13, 13 20 13'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13, 13, 13 22 14'-O" 7, 9, 9, 9, 9, 11, 11. 11. 13. 13, 13. 13 22 MODELS 5200 8000 8024 8100 8124 8500 2" THICK DOOR HEIGH CLIP #'S FROM BOTTOM TO TOP SPLICE # 7'-0" 5, 6, 6, 7, 7, 9 12 8'-0" 5, 6, 6, 7, 7, 9, 9 12 9'-O" 5, 6, 6, 7, 7, 9, 9, 9 14 10'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11 14 11'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11 16 12'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11, 11 16 13'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11, 11, 13 18 14'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11, 11. 13, 13 18 MODELS 6100 8300 (1-1/2" TO 1-3/8" THICK HEIGHT CLIP #'S FROM BOTTOM TO TOP SPLICE # 7'-0" 4, 4, 4, 4, 5, 6 8 8'-0" 4, 4, 4, 4, 5, 6, 6 8 9'-0" 4, 4, 4, 4, 5, 6, 6, 7 8 10'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7 8 11'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9 10 12'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9 10 13'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9, 9 12 14'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9, 9, 9 12 MODELS 9100 9400 9600 9700 9800 1" THICK DOOR r HEIGHPATE CLIP #'S FROM BOTTOM TO TOP SPLICE # 7'-0" 4, 4, 4, 4, 4, 4 6 8'-0" 4, 4, 4, 4, 4, 4, 4 6 9'-0" 4, 4, 4, 4, 4, 4, 4, 4 6 10'-0" 4, 4, 4, 4, 4, 4, 4, 4, 4 6 ACK SUPPLEMENT CHART Gagne; Balton 6/11/03 I PSF FOR D )R 'TEXAS WALL To "CONTINUOUS TTlnuous 8/21/07 )ATED SPUCE h CLIP IEDULES. 9/06/07 UPDATE MOUNTING 'AIL DRAWNGS 110/05/07 %PANDED 1-1/2- TO 8' DOOR THICKNESS T UP TO 14' HIGH. 12/11/08 307494 I P9 A Division of Overhead Door Corporation Jamb Connection Supplement This document provides a series of connection schedules and basic detailing concepts for the connection of garage door iambs to building frames with the use of various fasteners. DASMA Technical Data Sheet TDS-161 may be used as an alternate to this document. P/N 324620 Rev. P10 SCHEDULEI 3/8" DIAMETER LAG SCREWS MAXIMUM SPACING OF LAG SCREWS PER JAMB N MAIN SUPPORT MEMBER SPECIES SYP SPECIFIC GRAVITY-0.55 DOUGLAS FIR SPECIFIC GRAVITY -OAS SPF SPECIFIC GRAVITY -0.42 LOAD PER JAMB LB/Fi"ore3 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24 24 24 240 24 24 24 260 24 24 22 280 24 23 20 Boo 24 22 19 320 23 20 18 340 21 19 16 360 20 18 16 350 19 17 15 400 18 16 14 420 17 15 13 440 16 15 13 460 18 1 14 12 480 15 13 12 600 14 13 11 520 14 12 11 640 13 12 10 560 13 11 10 580 12 11 9 600 12 11 9 620 12 10 9 640 11 10 9 660 11 10 8 680 10 9 8 700 10 9 8 720 10 9 8 740 10 8 7 760 9 8 7 780 9 8 7 800 9 8 7 1. BASED ON 3/8" DIAMETER LAG SCREWS WITH 1-1/2" O.D. WASHERS WITH A 1-9132" THREAD PENETRATION INTO SEASONED DRY WOOD SUPPORTING STRUCTURE. 2. PROVIDE QUANTITY OF LAG SCREWS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) LAG SCREWS PER JAMB. LAG SCREWS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD=30psf DOOR WIDTH =16ft LOAD PER JAMB = 30psf x 161112 = 2401b/ft 4. CHART IS BASED ON 6'-6" MINIMUM AND 24•-0" MAXIMUM DOOR HEIGHT. 5. DOOR JAMB TO BE 2x4 OR LARGER NO.2 GRADE SPF LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTNER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 1111I+'/ 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. MINIMUM EDGE DISTANCE SHALL BE 10, MINIMUM FASTENER SPACING SHALL BE 1-1/2', TO PREVENT SPLITTING. �\ �O, y%CE6j8'•,F AND ALL HOLES SHALL BE PRE -DRILLED �. B. CALCULATIONS CONFORM TO ANSVAF&PA NDS-2005. No. 51737 9. LAG SCREWS SHALL CONFORM TO ANSI / ASME STANDARD B18.2.1. '. 7y nM` STATE OF ;'Or- APOfOVed John E.Sates, P.E. u i�rl/IZ S..... G\?N 3121 Fatrgate Dr. ////�i'1� Carrollton, TX 75007 IIIE\\\\\ FL PE 51737 TX PE 56308/F2203 Revision PIC SCHEDULE3 3/8"0 A307 HEADED OR HOOKED ANCHOR BOLTS IN NORMAL WEIGHT CONCRETE MAXIMUM SPACING OF ANCHOR BOLTS PER JAMB (IN) LOAD PER JAMB L N0TES 2000 PSI CONCRETE 2500 PSI CONCRETE 3000 PSI CONCRETE 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 1 24 24 24 220 24 24 1 24 240 24 24 24 260 24 24 24 260 24 24 24 300 24 24 24 320 24 24 24 940 24 24 24 360 23 24 24 380 22 24 24 400 20 24 1 24 420 19 24 24 440 19 23 24 460 18 22 24 480 17 21 24 500 16 20 24 520 16 20 24 540 15 19 23 560 14 18 22 580 14 16 1 21 600 13 17 20 620 13 16 20 640 13 16 19 660 12 15 19 680 12 15 1B 700 11 14 17 720 11 14 17 740 11 14 i6 760 11 13 16 780 10 13 16 800 10 13 15 \\\\�uiiiiuni/ `\\\\ CNN E. Sc T �V/ ttOEpB# No. 5173 1t ' 7 = STATE OF � AENG�\�� 1. BASED ON 318"0 A307 HEADED OR HOOKED (1.69" MIN. HOOK LENGTH) ANCHOR BOLTS WITH AZ' O.D. WA ra lM WITH A MINIMUM EMBEDMENT DEPTH OF 3" AND A MINIMUM EDGE DISTANCE OF 3". 2. PROVIDE QUANTITY OF ANCHOR BOLTS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) ANCHOR BOLTS PER JAMB. ANCHOR BOLTS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD =30psf DOOR WIDTH=16ft LOAD PER JAMB = 30psf x 16fU2 = 2401b/ft 4. CHART IS BASED ON 6-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 5. DOOR JAMB TO BE 2x6 NO.2 GRADE SPF LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTNER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. CALCULATIONS CONFORM TO ANSUAF&PA NDS-2005 AND ACI 318-05, APPENDIX D. John E. Scates, P.E. 0 3121 Fairgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE 56308/F2203 Revision P10 SCHEDULE2 16d COMMON WIRE NAILS AND 16d THREADED HARDENED -STEEL NAILS MAXIMUM NAIL SPACING PER JAMB IN MAIN SUPPORT MEMBER SPECIES SYP SPECIFIC GRAVITY -0.55 DOUGLAS FIR SPECIFIC GRAVITY -0.46 SPF SPECIFIC GRAVITY -OAP LOAD PER JAMB LB/FT)�a 100 24 24 19 120 22 20 16 140 19 17 14 160 16 15 12 180 14 13 10 200 13 12 9 220 12 11 8 240 11 10 8 260 10 1 9 7 280 9 8 7 300 8 8 6 320 8 7 6 340 7 7 n/a 360 7 6 Na 380 7 6 n/a 400 6 6 n/a 420 6 nfa n/a 440 6 Na n/a 460 Na n/a n/a 480 We Na n/a Soo Na n/a n/a 520 Na n/a n/a 540 n!a n/a n/a 560 n!a n/a Na 580 We n/a n/a 600 Na n/a n/a 620 Na n/a Na m n/a n/a n/a 660 Na Na n/a 680 n!a n/a n/a 700 Na Na n/a 720 Na Na Na 740 Na n/a n/a 760 Na Na rda 780 n/a n/a n1a 800 We we Na \�\%lIilI l l//////7/ CE s�gT�s //� i NO.51737 Y srATEOF ; k:Z- O �. 1. BASED ON 16d COMMON WIRE NAILS (0.162"x3-1/2") OR 16d THREADED HARDENED -STEEL NAILS (0.148"x31/0) WITH A MINIMUM PENETRATION OF 2" INTO SIDE GRAIN OF MAIN MEMBER. 2. NAILS SHALL BE PROVIDED IN PAIRS AT A MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) PAIRS OF NAILS PER JAMB. NAILS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD=30psf DOOR WIDTH =16ft LOAD PER JAMB = 30psf x 161t12 - 2401h/ft 4. CHART IS BASED ON 6'-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 5. DOOR JAMB TO BE Zx4 OR LARGER NO.2 GRADE SPF LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTNER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. EDGE DISTANCES, END DISTANCES AND SPACINGS SHALL BE SUFFICIENT TO PREVENT SPLITTING OF THE WOOD. 8. CALCULATIONS CONFORM TO ANSI/AF&PA NDS-2005. Aonroved John E. Scates, P.E. V '('3 (Z- 3121 Falrgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE SS308IF2203 Revision PI SCHEDULE4 3/8" RJ SIMPSON TITEN HD SCREW ANCHORS MAXIMUM SPACING OF ANCHORS PER JAMB (IN) LOAD PER JAMB LB/ Nme4 2000 PSI CONCREOOTE1 4000 PSI CONCRETENOrst 2000 PSI GROUT FILLEDCMUNOTE2 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 160 24 24 24 200 24 24 24 220 24 24 24 240 24 1 24 24 260 24 24 22 280 24 24 20 Soo 24 24 19 320 24 24 18 340 24 24 16 360 24 24 16 380 24 24 15 400 24 24 14 420 24 24 13 440 24 24 13 460 24 24 12 480 23 23 12 Soo 22 22 11 520 21 21 11 540 20 20 10 560 19 19 10 580 19 19 9 600 18 18 9 620 17 17 9 640 17 17 9 660 16 16 8 680 16 16 8 700 15 i6 8 720 15 15 8 740 15 15 7 760 14 14 7 780 14 14 7 800 13 13 7 '0, N EE s FAr�s //i N0.51737 i�a ` STATE OF ;;tea` ,•• O�FS ;tOR10G\���� aloNA ` �1(�0\\ 1. BASED ON 3/8°0 SIMPSON TITEN HD SCREW ANCHOR WITH A 1-3W O.D. WASHER INTO NORMAL WEIGHT CONCRETE WITH A MINIMUM EMBEDMENT DEPTH OF 2-3/4" AND A MINIMUM EDGE DISTANCE OF 2-3/4". 2. BASED ON 3/8"0 SIMPSON TITEN HD SCREW ANCHOR WITH A 1-3W O.D. WASHER INTO GROUT FILLED CMU WITH A MINIMUM EMBEDMENT DEPTH OF 2.3W, A MINIMUM EDGE DISTANCE OF 4°, AND A MINIMUM END DISTANCE OF 4". CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND GROUT SHALL CONFORM TO ASTM C476. 3. PROVIDE QUANTITY OF SCREW ANCHORS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OFTHREE (3) SCREW ANCHORS PER JAMB. SCREW ANCHORS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 4. LOAD PER JAMB CALCULATED BYTAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY2. EXAMPLE: DESIGN LOAD =30psf DOOR WIDTH -16ft LOAD PER JAMB = 30psf x 161112 = 2401b/ft 5. CHART IS BASED ON T-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 6. DOORJAMB TO BE 2x6 NO.2 GRADE SPF LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. - IF MOUNTING OVER DRYWALL, INCREASE FASTNER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 7. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 4. 8. CALCULATIONS CONFORM TO ANSVAF&PA NDS-2005. 9. SCREW ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. John E. Sates, P.E. f� 3121 Fairgate Dr. / Carrollton,TX75007 FL PE 51737 TX PE 56308/F2203 Revision P10 Wag 3395 ADDISON DRIVE PENSACOLA, FLORIDA 3251, (850) 474-9890 too. 5l E" ice q . STATE OF u ��O••`• FLOR��p'� �_�� �$A� pey-f t(tr 3:21 FNRGATE DR. GMg1lfN. U TSGPI & PE SqA T%PE 5W03/F22O] DOOR r¢ HFAOER LOCK MINIMUM 2x6PS ¢HEADER LOCK MINIMUM 2xe }l PINE l PRAM(R 9n1mmu PiY, (�....._._ _ r¢ HEADER LOCK x-3/4' SIMPSON TITEN HD SCREW NTH A 1 1/4' WASHER AND IM EMBEDMENT DEPTH OF AND A MINIMUM EDGE OF 2-3/4'. DETAIL I MINIMUM 2000 PS CONCRETE NO L M"WUM DESIGN LOAD CAPACITY OF M85 MS. MINIMUM P MMU SI GROAT CMI NDTF, MAXIMVM DESIGN LOAD CAPAOTY OF 2400 MS. 1—i /2'J IFe HO SCREW (4) 3/B' DIX LAG SCREWS WASHER AND WTH 1-1/4' O.D. WASHERS. DEPTH OF LAO SCREWS SHALL HAVE A EDGE MINIMUM PENETRATION OF 1-9/32' INTO THE MAW SUPPORT MEMBER DETAIL 3 s RT ST2 D ILA M M 9CN 5iC E TY OF CAPACITY OF 2430 L85. D A CHECKED JAMB CONNECTION SUPPLEMENT DR, I 5/24/07 MRS MNG PART NO. I REV. 324620 Pl0 DocuSign Envelope ID: F67AF1B8-18BC-4E74-8D40-E5F158568861 Jax Apex Technology, Inc. FBPE CA NO. 7547 4745 Sutton Park Court, Suite 402 Jacksonville, FL 32224 Evaluation reports are the opinion of the engineer who prepared the report, based on the findings, and in no way constitute or imply approval by a local building authority. The engineer, in review of the data submitted, finds that, in his opinion, the product, material, system, or method of construction specifically identified in this report conforms with or is a suitable alternate to that specified in the Florida Building Code, SUBJECT TO THE LIMITATIONS IN TMS REPORT Jeffrey P. Arneson, an employee of Jax Apex Technology, Inc. (Apex Technology), is the authorized evaluating engineer of this report. Apex Technology is the prime professional, as defined in Florida Rule 61G-30.002, authorized to sell the engineering services performed by Jeffrey P. Arneson, and is in no way acting, nor attempting to act, as an approved evaluation entity. Neither Jeffrey P. Arneson, nor any other employee of Apex Technology, has performed calculations or testing for the products listed in this report. This evaluation is based solely upon the review, under the direct supervision of Jeffrey P. Arneson, of testing and/or calculations submitted by the manufacturer. The capacities listed in this report are based on the limiting capacities as determined from the substantiating data. We reviewed the substantiating data to a degree that allowed us to determine whether or not the work performed is consistent with the intended use of the product, and that the methods used are in compliance with, or meet the intent of, the Florida Building Code. All test reports were prepared by an approved testing laboratory. REPORT NO: WD04879 CATEGORY: Doors and Windows SUBMITTED BY: Wayne Dalton Corporation 3395 Addison Drive Pensacola, FL 32514 1. CERTIFICATION OF Jeffrey P. Arneson, the Florida engineer who prepared this report, and Apex Technology have no financial interest in the manufacturing, sales, or distribution of the products included in this report. Jeffrey P. Arneson and Apex Technology comply with all criteria as stated in Florida Administrative Code Chapter 9N-3.009. PA=io)1list 91I_1uIA Model 8700 garage doors. Page I of Wayne -Dalton DocuSign Envelope ID: F67AF1B8-18BC-4E74-8D40-E5F1585688B1 3. SCOPE OF EVALUATION Structural Transverse Wind Loads CM1,R1_� Model 8700 garage doors are used for residential applications with specified allowable design pressures. I.167;61a7Ii1ma k General Model 8700 garage doors listed in Table 1 of this report are sectional overhead doors and are constructed of minimum .052" vinyl facer and a minimum .032" vinyl backer. The doors have a polyurethane insulation sandwiched between the interior and exterior skins and 20 gage end caps. Each section shall have a 1-1/4" x 1-1/2" x 22 ga continuous internal rails at the top and bottom of each section. The ends of each rail in the top of each section shall be reinforced with a 15 gage reinforcing bracket. The sections shall have 20 gage backup plates at all intermediate hinge locations. The sections are 1-5/8" thick with tongue and groove joints and shall have a maximum section height of 21". Door Tracks All door assemblies listed in this report have both vertical and horizontal tracks ranging from a minimum 16 gage to minimum 15 gage, 33 ksi steel and finished with an ASTM A525 G-40 galvanized coating. The vertical tracks are attached to the supporting structure with jamb brackets as specified on the most recent manufacturer's installation instructions/drawings. Glazed Sections Unless noted otherwise, the option code assemblies listed in Table 1 of this report are available with a minimum of 0.125-inch thick standard SSB glass windows that are installed in frames and inserted in the top or intermediate section of the door. The glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. Refer to the most recent manufacturer's installation instructions/drawings for glass size limitations. Wind Load Bracing All option code assemblies listed in Table 1 of this report are braced on the inside of the doors with three inch horizontal spanning U-bars. Each U-bar is made of either 18-gage or 20-gage ASTM A653-00 steel with a minimum yield strength of 80 ksi and are finished with an ASTM A525 minimum G-40 galvanized coating. The gage and quantity of U-bar braces varies depending on the amount of windload resistance required and the height of the door. In addition to three-inch horizontal spanning U-bars, some of the option code assemblies listed in Table 1 of this report are braced with vertical aluminum posts made up of 0.125- inch thick 6063-T6 aluminum alloy. The post is a telescoping post assembly. The outer member outside diameter is 1.75" wide x 4.00" long. The inner member outside diameter is 1.47" wide x 3.72" long. Page 2 of 4 Wayne -Dalton DocuSign Envelope ID: F67AF1B8-18BC-4E74-8040-E5F1585688B1 6. INSTALLATION All option code assemblies listed in this report are to be installed in accordance with the most recent manufacturer's published installation instructions/drawings and this report. The most recent manufacturer's installation instructions/drawings shall be strictly adhered to and a copy of these instructions/drawings shall be available at all times on the job site during installation. 7. ALLOWABLE TRANSVERSE WIND LOADS Design wind load pressures for garage doors shall be determined in accordance with section 1609 of the 2010 Florida Building Code and shall not exceed the allowable transverse wind loads shown in the following tables: Table 1: Model 8700 Garage Door Allowable Transverse Wind Loads Windload Specification Option Code Maximum Size Positive Design PSF Negative Design PSF Reinforcement Glazing Available es/No Width Height 1000 T-0" 14'-0" 22.90 26.30 3", 20 gage U-bars Yes 1001 914" 14'-0" 31.20 35.80 3", 20 gage U-bars Yes 1002 9'-0" 14'-0" 41.60 46.30 3", 20 gage U-bars Yes 1020 16-0" 14'-0" 23.00 25.00 3", 18 gage U-bars Yes 1021 16'-0" 14'4' 30.00 33.50 3", 18 gage U-bars No 1022 16'4" 8'-o" 43.40 48.40 1 3", 18 gage U-bars+ (2) Aluminum Posts Yes 1040 18'-0" 12'-0" 18.50 20.70 3", 18 gage U-bars Yes 1041 18'-0" 12'-0" 25.90 28.80 3", 18 gage U-bars No 1042 18'-0" 8'-0" 39.20 43.70 3", 18 gage U-bars + (2) Aluminum Posts Yes 8. SUBSTANTIATING DATA For Premium garage doors, Test Report Number ETC-07-976-18894.0 in accordance with ANSI/DASMA 108-2002 for transverse wind load by ETC Laboratories, 297 Buell Road, Rochester, N.Y. Installation drawings and installation instructions prepared by Wayne -Dalton Corporation for each option code assembly listed in Table 1 of this report. 9. CODE REFERENCES Florida Building Code 2010 Edition Section 1609 Wind Loads Section 1715.5.3.1 ANSI/DASMA 108 10. REPORT SUMMARY Upon review of the data submitted by Wayne -Dalton, it is my opinion that the models as described in this report conform with or are a suitable alternative to the code standards and sections in the Florida Building Code 2010 edition listed in section 9 of this report. Page 3 of 4 Wayne -Dalton DocuSign Envelope ID: F67AF1B8-18BC-4E74-8D40-E5F7585688B1 11. LIMITATIONS Any reference in this report to the manufacturer's "most recent" information is a direct reference to the most recent information submitted by Wayne -Dalton to the Florida Building Commission as part of their Florida Product Approval application for the option code assemblies listed in Table 1 of this report. This evaluation report and the most recent installation instructions, when required by the building official, shall be submitted at the time of permit application. The design of the supporting structural elements shall be the responsibility of the design professional for the building structure and in accordance with current building codes for the loads listed in Table 1 of this report. The doors shall not be located in areas where the transverse wind loads exceed the allowable loads shown in Table 1 of this report. The option code assemblies with glazed panel inserts do not meet the impact requirements for the wind-borne debris regions. The garage door assemblies listed in Table 1 of this report are not approved for use in the "High Velocity Hurricane Zone" as defined in the Florida Building Code. 12. IDENTIFICATION Each Model series covered by this report shall be labeled with the manufacturer's name and/or trademark for field identification. � . P. a.".L No. 58044 OF Jax Apex Technology, Inc. Jeffrey P. Amason, P.E. P.E. No. 58544 February 20, 2012 Page 4 of 4 Wayne -Dalton