IN -PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL
AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) - ASTM 6938
Project: PGA Sales Center
Project ID: 14-1191.01
Address: 9700 Reserve Blvd., Port Saint Lucie
Report ID: D-0012
Client: Anderson Moore Construction Corp.
Date: 2/12/2015
Permit No: Atj ( _ q�-1 Feld Tech: Ken Thomas
Test Mode: Direct Transmission
Area Tested: Retaining wall footing
Soil Descrip0on: Gray fine sand
Proctor I LBR ID: P-1 Max Density (PCF): 110.0 Opt Moisture (%): 11.6% Test Standard: D_1557__
Compaction Required (%): 95.0% Probe Elev
Wet Dry Moist. Compaction
Depth
Location
DensltyDensfty (%) % Results
(in)
(PCF) (PCF)
1
North end of area
12
0-1
118.6
107.7
10.1%
97.9%
Pass
2
South end of area
12
0-1
120.6
109.1
10.5%
99.20/6
Pass
3
4
SCANNED
o..
5
St. Lucie County
6
7
tl
a
t
0
1
1
t
z
Testing Gauge Information: Manufacturer: _ Troxler Model:
3430 SIN: 22260 _
Density Standard (DS): 1998
Moisture Standard (MS):--.-678
Remarks: Testing completed - below finished grade
J%J1111l'rrrr/
Legend for Elevation:
Res v%,t6
PR = Procfroll 1, 2, 3 =1st, 2nd, 3rd Lift
Gr`^A IiHer tional, Irf�.'
SL = Springline FL = Final Lift
F4 4d # 420675 w
SG = Subgrade BG = Below Grade
BC = Basecourse BOF = Bottom of Footing
-
OP =Top of Pipe FG = Finished Grade
fd, POFF �:
Prg�"API(]E],,nnpgineer # • �75
Test report shall not be reproduced, except in full, without the written approval of GFA International SIaCe ai�if FWp;,� �•••�\?�%
Environmental . Geolechnicai . Construction Materials Testing . Special and Threshold Inspections Qgtre pfianee
Florida's Leading Engineering Source r 1111111
www.teamgfa.com RECEIVED FEB 18 2015
305
521 NW Enterprise Drive. Port St. Lucie, Florida 34986
03;' `' p.m. 02-12-2015 1/1
ffP& (772)924-3575 . (772)924.3580 (fax)
err
V
ANA'r\DloP
IN -PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL
AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) - ASTM 6938
Project: PGA Sales Center _ Project ID: 14-1191.01
Address: 9700 Reserve Blvd., Port Saint Lucie Report ID: D-0012
Client: Anderson Moore Construction Corp. Dale: 2/12/2015
Permit No: \ S Field Tech: Ken Thomas Test Mode: Direct Transmission
Area Tested: Retaining wall footing
SoilDescriptlon: Grayfinesand
Proctor/ LBR ID: P-1 Max Density (PCF): 110.0 Opt Moisture (%): 11.6% Test Standard: D 1557
Compaction Required (%): 95.0% Probe Elev Wet Dry Moist. Compaction
Location Depth Density Density (%) % Results
(in) (PCF) (PCF)
1
North end of area
12
0-1
118.6
107.7
10.1 %
97.9%
Pass
2
South end of area
12
0-1
120.6
109.1
10.5%
99.2%
Pass
3
4
5
6
7
6
9
1
0
1
1
1
2
Testing Gauge Information: Manufacturer: Troxler Model: 3430 SIN: 22260
Density Standard (DS): 1998 Moisture Standard (MS): 678
Remarks: Testing completed - below finished grade
Legend for Elevation: Re
PR = Proofroll 1, 2, 3 = 1 st, 2nd, 3rd Lift GJiA Intitrf'�tiona[, Itt
St. = Springline FL = Final Lift Ar, F4PL-G # 4§'39 0675 ;
SG = Subgrade BG = Below Grade to l.g 10 _ o
:—
BC = Basecourse BOF =Bottom of Footing
CE
TOP =Top of Pipe FG = Finished Grade R rd WSfpJgj�E, DOFF �,(���
Pf 091 Engine #; �P°
.Z
ya,,
Test report shall not be reproduced, except in full, without the written approval of GFA International State a$�il' FWq;,,
Environmental . Geotechnical . Construction Materials Testing . Special and Threshold Inspections . PIan1fe ` %ftblEd jkGbhipliance
Florida's Leading Engineering Source rrrllrrl
w=Jeamgfa.com
Chapter 18 - Soils and Foun,?.*,*;ons
Page 1 of 2
State
[ 2010 Florida Building Code: Building (First
Printing)
■ Chapter 1.8 - Soils and Foundations
■ SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND
EMBEDDED POSTS AND POLES
■ 1807.2 Retaining walls.
SCANNED
1807.2.1 Desian. BY
180.7.2.2 Hydrostatic pressure. St. Lucie CoUntt,
1807.2.3 Reinforced masonry retaining walls.
1807.2.4 Segmental retaining walls.
Top Previous Section Next Section To view the next subsection please select the Next Section
option.
0
1807.2.3 Reinforced masonry retaining walls.
Vertical reinforcement for masonry retaining walls shall comply with Table 1806.4 or shall be
designed in accordance with ACI 530/ASCE 5/TMS 402. Masonry shall be fully grouted with a
minimum f„, of 1,500 psi (10 343 kPa). Mortar for masonry shall be Type M or S and laid in
running ring bond. The specified location of the reinforcement shall equal or exceed the effective
depth distance, d, noted in Table 1807.2.3 and shall be measured from the exposed side of the
wall to the center of the vertical reinforcement. Footings for reinforced masonry retaining walls
shall be designed in accordance with ACI 318.
TABLE 1807.2.3 REINFORCEMENT FOR MASONRY RETAINING WALLS
Nominal Wall
thickness
Wall depth, H, ft
Reinforcement size & spacing for equivalent fluid weight of soil,
pef (kN/m3), of:
30(4.7)
45(7.1)
60(9.4)
[(in.) (mm)]
(m)
4.0 (1.2)
#4 at 64 in.
#4 at 40 in.
#4 at 32 in.
4.7 (1.4)
#4 at 40 in.
#4 at 24 in.
#4 at 16 in.
8 (203)
5.3 (1.6)
94 at 24 in.
#4 at 16 in.
#5 at 16 in.
6.0 (1.8)
#5 at 24 in.
#6 at 16 in.
98 at 16 in.
6.7 (2.0)
#5 at 16 in.
#6 at in.
-
4.0 (1.2)
94 at 72 in.
#4 at 64 in.
#4 at 48 in.
4.7 (1.4)
#4 at 56 in.
#4 at 40 in.
#4 at 24 in.
5.3 (1.6)
#4 at 40 in.
#4 at 24 in.
#4 at 16 in.
10 (254)
6.0 (1.8)
94 at 24 in.
#4 at 16 in.
#5 at 16 in.
6.7 (2.0)
94 at 16 in.
#5 at 16 in.
#6 at 16 in.
7.3 (2.2)
#5 at 24 in.
#6 at 16 in.
#6 at 8 in.
8.0 (2.4)
#5 at 16 in.
#6 at 8 in.
http://publicecodes.cyberregs.comistlfllstlb200v101st_fl_st b200v10_18_sec007_par016.htm 2/3/2015
Chapter 18 - Soils and Foun,.9* ons
Page 2 of 2
12 (305)
4.0 (1.2)
4.7 (1.4)
5.3 (1.6)
6.0 (1.8)
6.7 (2.0)
7.3 (2.2)
8.0 (2.4)
8.7 (2.7)
9.3 (2.8)
#4 at 72 in.
#4 at 72 in.
#4 at 48 in.
#4 at 32 in.
#4 at 24 in.
#4 at 16 in.
#5 at 24 in.
#5 at 16 in.
#6 at 16 in.
#4 at 72 in.
#4 at 48 in.
#4 at 32 in.
#4 at 24 in.
#4 at 16 in.
#5 at 16 in.
95 at 16 in.
97 at 16 in.
#7 at 8 in.
#4 at 64 in.
#4 at 40 in.
94 at 24 in.
#4 at 16 in.
#5 at 16 in.
#6 at 16 in.
#7 at 16 in.
#7 at 8 in.
a. Based on fully grouted masonry; f'm = 1500 psi (10.3 MPa); d = 5 in., 7 in. and 9 in. (127, 178 and 229 mm)
for wall thicknesses of 8, 10, and 12 in. (203, 254, and 305 mm), respectively; level backfill to top of wall.
Too Previous Section Next Section To view the next subsection please select the Next Section
option.
COPYRIGHT 2007 by INTERNATIONAL CODE COUNCIL, powered by citation®
http://publicecodes.cyberregs.comistlfllstfb200v10/st fl st_b200v10_18_sec007—paz016.htm 2/3/2015