HomeMy WebLinkAboutPROJECT INFORMATIONv
lndustrlal Auto : wood 7
.. e
E 5 AT
�.. -
SC> AED
•:EZTO'INSTALL •EZ30MAINTQIN -IT,L CIECOIRMBUiL3?INODN410N` �
' fit. Lucie Cuunty�
EZ'TO OPERATE • EZ TO ADD HEAT' PM -Reviewed Not is Com Hance
I Reviewed By:
:
Date;
_v
�;r 1�q1 a P
3^t ¢c y 1 f
t
; :��i 2i-.nt� Tb �"4 �,'� t[a � � !� s � Ir • t ' �`� � i ° t �:`i
m�
CONSTRUCTION FEATURES AND QUALITY STANDARDS BOOTH SHOWN WITH OPTIONAL CURTAINS
The Hanging Intake Plenum and Exhaust Plenum Wall will be fabricated with 18-gauge galvanized steel panels; flanged for strength
and pre -punched for easy nut and bolt assembly. The intake plenum may be suspended with a maximum of 10' tall clearance or as
low as T tall clearance. The actual installed height is required to order the GoffsTM Curtain walls.
Intake air is supplied by one (1) 18" diameter tubeaxial fan with a 1-1/2 HP, three-phase motor. Exhaust is provided by one (1) 18"
diameter tubeaxial fan with a 1-1/2 HP, three-phase motor.
Col -Met Spray Booths' EZ Limited Finishing Prep Station complies with NFPA 33 regulations pertaining to limited finishing
workstations. Optional ETL listing with purchase of control panel and curtains is availabe.
_ .OVERVIEW= A
t The Col -Met EZ'L`im ted Finishing Prep Station,dr4ws-fresh air from the cleaner'upper level`s oftheshop through,Pa.pr'essurization,,t:'
5 fan. This air is forced down`into,the prep station through a filter bank located In the ceiling near the entry. The air,i's drawn through'';`
' the prep station work area into afiltered exhaustplenum at the opposite end and exhausted out to the atmosphere through the .,
'exhaust fan and stack. This design allows for -easy addition -of a`heated air makeup unit. Panels;;assembly hardware, filters, and
.'sealants neededJor mechanicalinstallation,are included. The threaded rod,forsu`spending thee -intake plenum is not supplied
by Col -Met. Goffs- Curtain wails, intake and exhaust. stack, control panel,,and other electrical. components may be purchased
separately. ,,..
LIGHTING FEATURES
` Bright, full booth illumination is,provided byeighf (8)four-tube, 48"long, 32-watt, fluorescent ligh{fixtures:in the.ceiling panels.
{ ; 'Each' is sealed behind clear tempered safety glass. All fixtures -are UL listed and `approved for#heir intended use and placement =3 Q
- gp
1 -11 1
v
Model
Number
Interior Dimensions
Width Heiqhtj
Lenqth
Exterior Dimensions
� With
Nominal Clear Entry
Width I Heiqht
I Lights
Open
� Air Flow
SUM
Fan Spec.
Dia. I HP
Filters
Int.Ext.
x'
�l
EPS-14-10-24-P-5B
14 1-0"
10'-0"
24'-0"
1 14'-4'
112'-2"126'
6"1
14'-0" 1 10'-0"
1 8
15,000
(2)18"1
1.5
12
2
Referen'ee Key
13 =
c -
.1 .
V
-4, "J
COL -MET SPRAY BOOTHS COMPLY WITAALL:A'PPLICABLE
OSHA