Loading...
HomeMy WebLinkAboutCERTIFICATE FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department —'Building & Code Regulations Division - - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 nCertification for Design Load Compliance Project Name: t l ` tW KF nA16R*1 % WbigIKars14 NY CAt. CIEPf Project Address: at17ff) IVIAKI r0Zft v ry G ✓ Permit#: 15ol - CM9 Occupancy Type: K Lb construction Type:13 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • " Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:. o New Residences (single ormulti-family) of ANNED o Residential Addition BY o Any accessory structure requiring a building permit : r I I Ir;IQ County o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida f3viLpMr Code 2010 Edition with 2012Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed J%,Partially Enclosed _Open 3. Risk Category: _I y' II _ill _ IV Exposure Category: _B _'�_C _D 4. Design Wind Velocity mph ASD _LRFD End Zone Width: ft tiu 5. Mean Roof Height Roof Pitch: VM1_:12 Parapet: It 6. Components & Cladding Design Pressures Used: (PSF, based on 10s ft 15'MRH, clear lab on all plan openings): j�! D 1►� 0.{—�ly{0 �} Zone 1 � 2_ one 2+�/—Ill.r Zone Ei � Zone 4. 4one 5: - - . Arage: 7. Design Loads: Floor: IOQ PSF Roof/Dead: TPSF Roof/Live: AD Balcony: PSF Dock: PSF Deck:_PSF Stairs: PSF Fence: PSF Railings: - PSF 8. Were Shear Walls Considered For Structure? Yes ' Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? 2 ' Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: ZDQ PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: F ,Signature, Date, and Seal SLCCDV Form #-020-12 Revised 3/15/12 (JS) i Kart i 13 tTWRt .*5 4I9 Printflpme �� Cart # & Co. Cert Auth. [_AAOG�t (0316TIZOC 10t) C tkVe!r Company Name &Address 13 90 �bNr ►J`Ra4 f� LAr&cv01 1 U 33�:1 1