Loading...
HomeMy WebLinkAboutSIGN PLANSe5250 S U51, Ft. Pierce, FI 34982 • FIB: THIS SIGN CONFORMS TO THE REQUIREMENTS {' 8'-0" OF FLORIDA BUILDING CODE 2010 ULTIMATE DESIGN WIND SPEED V(ULT) = 150 MPH ._ RISK CATEGORY = I EXPOSUREC INTERNALLY ILLUMINATED DOUBLE SIDED SIGN STRUCTURE: FABRICATED ALUMINUM SIGN EXTERIOR WITH INTERNAL ALUMINUM ANGLE FRAME CONSTRUCTION ILLUMINATION: SIGN TO HAVE INTERNAL 800 M.A. H.O. FLUORESCENT LAMPS ON 12" CENTERS AND INTERNAL BALLASTS INSTALLATION: SIGN MOUNTED ON SINGLE VERTICAL STEEL 8"SQUARE STEEL SUPPORT POLE WITH DIRECT BURIAL CONCRETE FOUNDATIO �a®®.......... I"Be TYPICAL POLE TO SIGN L s� CABINET CONNECTION Better �,�.•'��• - 94, �DETAILED ON SHEET Wna 5" SCH40 ASTM A53grB STEEL PIPE 1C1 �I SCANNED �sIN, S�'i BACK RBA, St. Lucee'eunt\ FRONT 8 X 8" X 5/16" WALL ASTM A500 STEEL TUBE t BIDES SECTION MODULUS =23.71NA3 IDES CNRS�MINIMUM REQUIRED=23.2 INA3 1 I REAR LNG. TECH 5' 6" DIAMETER X 5' 0" DEEP 3000 PSI CONCRETE EMBEDMENT NOTE: ANY SHAPE AT LEAST 5'6"WID I'o o IS ACCEPTABLEO hod �b"obo o.� o I 'O�oa p. sb'o RCK Auto Sales 18'OAH sign by Glomaster Signs John J. Orlando PE LLC 165 Old Ridge Road Macon, GA 31211 478 731 5394 Florida registration # 0044089 sheet 1 of 3 scale: 3/8"=1'0" job 0315GM I'o ',o�'�o •< [2- o' T-6" • Prices! 12'-0" m GRADE 0" a•o:.. o'o � :o p 15! _o oiw'0 9 „M16FALEB FASTENERS ORATTACNII ARE THE RESPONSIRIM OF NE man OFWOrm mold' 5,250 S U,S1, Ft. Pierce, FI 34982 CON ApEtHEA�p(1N51611nY OFTN� ALUMINUM ANGLE RETAINER TYPICAL SIGN CABINET SYSTEM BOX FRAME AND SADDLE DETAIL SUPPORT L CopyEO EE O. GRADE ALUMINUM ANGLE RETAINER SYSTEM 2"x 3/16"ALUMINUM ANGLE BOX FRAMING STEEL ANGLE SADDLE 'Oory ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANC REVIEWED BY DATE - O PLA SAND PER IT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE RCK Auto Sales 18'OAH sign by Glomaster Signs John J.Orlando PE LLC 165 Old Ridge Road Macon, GA 31211 478 731 5394 Florida registration # 0044089 sheet 2 of 3 job 0315GM z 6(r ALUMINUM CLADDING ALUMINUM ANGLE CROSS MEMBER ALUMINUM ANGLE RETAINER SYSTEM STEEL SADDLE BOLTED TO ALUMINUM FRAME WITH 3/8"NUT & BOLTS THESE PLSsYS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECI"S THAT MAY BE NECE96ARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. THIS SIGN CONFORMS TO TH E REQUIREMENTS OF FLORIDA BUILDING CODE 2010 ULTIMATE DESIGN WIND°BOEI %OffQ,* 150 MPH RISKCATEGORY=1 J:"ORC poi EXPOSURE a%\Og0o�i AMU FASTENERS ORASTACHAm Job name IRto Sae ls 0315G Job# 0315GM Installation company: GloMaster Signs Installation location. 5250 S US1, Ft. Pierre, FI34982 Section 3107 and 1609 of Florida Building Code 2010 applies: Chapter 29 of ASCE 7-10 (Wind Loads on Other Structures and Building Appurtances) applies: Type of structure: Risk Category: Ultimate design wind speed, figure C, FBC 2010, section 1609: Wind stagnation pressure (qz) Table 1609.6.2 (1) FBC 2010 Design wind pressure conversion factor Gust effect factor (G) ASCE 7-10 26.9.1 Widest part of sign face (B) Height of sign face (s) Overall height of sign (H) Aspect ratio (B/s) Clearance ratio (s/H) Force Coefficient Cf from Figure 29.4-1, ASCE 7-10 Wind pressure (p) multiplied by design wind pressure conversion factor and Cf pylon sign I 1.50 mph 57.6 psf 0.77 0.85 8.00 18.00 18.00 0.44 1.00 1.2 45.2 psf 2. Calculate wind load and turning moments at base by the provisions of the alternate all -heights method in Section 1609.6. Wind shall be assumed to come from any horizontal direction and wind pressures shall be assumed to act normal to the surface considered. Hor Dim Vert Dim Fill Factor Af p F H M (base) (ft) (ft) (sf) (Ibs) (ft) (ft-Ibs) 8.0 18.0 1.0 144.0 45.2 6514 9.0 68630 0.0 45.2 0 0 0.0 45.2 0 0 0.0 45.2 0 0 Total 144.0 6514 9.0 58630 3. Determine depth of embedment, D in feet From Table 1806.2, class 4, sandy soil, lateral bearing pressure below grade= 150 psf/ft Per 1806.3.4 Increase for poles, tabular value time 2 = 300 psf/ft Assume depth of hole (D) = 5 ft (Si) = 1500 psf - number of posts= 1 Load per post (P)= 6514 -from p. 5-81, Structural Engineering Handbook: D=((1.18-P)/(b-S1))•(1+(SQRT(1+(1.88•b•S1 •H/P)))) assume b (ft)= 5.5 D (ft) = 5.3 Alternatively, Section 1807.3.2.1, Equation 18-1 1.85 A=2.5A((l+ 1+ D=O.5A((1+(1+(q:36h/A))^0.5)= 5.3 feet *� 16�i7� �c�������I@off■ 4. Determine required section modulus (in ^3) at base max stress = (P'(H)`l2)/section modulus max stress < allowable stress for outdoor signs, allowable stress < (0.66)(yield strength) steel grade yield strength required section > (P•(H)'12)/((0.66•ys)) At base, minimum section modulus = Use 8" x 8" x 5/16" wall steel tube, section modulus = References: Structural Engineering Handbook, Gaylord&Gaylord editors, Fourth edition, McGraw Hill, NY 1997 ASCE 7 lYe AIBIp�O 0 Florida Building Code 2007 with 2009 suppliils((�� Mechanics of Materials, Beer and Johns Mc ;aVp,ryy7od, ICBO Evaluation Report No. 4016 •;GE N S"c••., p SBCCI Compliance Report No. 93680� O; �, Standard Handbook for Mechanical jing aec,�„�. 0$urA�sie�' arid L.S. Marks, editors, Seventh edition.McGraw Hill, NY 1967 1'4 •- /arnT t- O� John J Orlando PE 0044089 O r 165 Old Ridge Road Macon GA 31211 °°j�0 O•••�,/ (478) 794-2226 .1 A500 46000 psi 23.17 in^3 23.70 in^3 sheet 3 of 3 Plaskolite DURAPLEX Prt, lies! Physical,, Chemical; Mechanical b• ientral mperite... Page 3 of5 DURAPLEX DURAPLEX TL-"ST' DURAPLEX OPTIX S605 DURAPLEX OPTIX SGI0 PHYSICAL METTIOD UNITS 30%. (50%) 70% (10()0/0) Specific ASTM D- Gravity/Relativc 7921SO 1,181.18 1.17L17 1:r61.i6 I_I;SL1,5, Density ) 183 Light AS',CM D-- Transmission - 10033180 No% 9292 9292 9090 9090 Total 13468-1 Light ASTM D- Transmission - Ip031SO 22. 22 >3>3 >3>3 lfize 14782 Water Absor bon 1' ASTM D- yo t y 0,303 0.305 0303 0.30.3 Obis662 U4°io M71tlShrinktige ASTt41' D- miisfin%3-603-0.6 3-603-().6 3-W1-0;6 3-60.3-0.6 955 ` E8T MECHANICAL METTIOD UNITS ASTM D- Tensile Strength 63$ISO psimpa 527 Tensile Modulus ASTM D- Elasticity fi38iSt) psiMPa of 527 ASTM D- Plexural'Strength 746180 psiMPa 1,78 DURAPLEX DURAPLEX DLIRAPI.EX OPTTX SGO5 DURAPLEX 0PT'IX SG10 9,00062 8,00053 7,10049 5,600.19 376,0.002t592.340,0002344 304,0002.096 230,0001,724 I-4)094 12,60083 L0,61073 8,30057 jzod Impact ASTM D- Strength-- 2561SO ft-lhlm otchk l to 0632 0.737 0.948 1.159 Malifed Notch 180 Bali Drop Impact DIN 52306 Pis$Pass: PassPass PassPass Passl'ass 2ackwell AS`,I;M D- Hardness: 78515t3 M-78M-78 M-68M•68 M-5{)M-59 M-46M-46 2039-2. DURAPLEX DURAPLEX ..< TEST DLIRAPLFX OPTIX SGOS DURAPLEX OPTIX SG10 THFRMAL ME11-1013 LJN117S 30% (50%) 70% (100%) Deflection ASTM D-- Temperature 6481SO °F°C 19892 19490 19098 "'.18595 ?64 psi (I,8' MP.u) ,,Coefficient of ASTM M U- 17 ermal int{in °I% } z 10' 3.56.3 x 10-3 6461SO 4T2'x 10-5 4:58.1 x 10-5 59.0 x 16-5 Expansion- 'IWC 11359 30 to'a0-C ('anmilehticl' AIM D �aani' tectnfmnt 0:8� 16 ` ;' I 4 1S': - LJ33 f9 19,7 4ti? 3urnuzgRaie)635-m Flammability DIN 4`.102. 52E2 B2B2 132B; B2B2_ Smoke ASTM D- ofoofo 5.25:2. 8.58.5 11.51 1.5 16.516.5. Density Rating 2843 Self -Ignition, ASTM D- 212412015