dD SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA
ILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION
FLORIDA (AAF) "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL
TABLE 1 MAIN MEMBER SCHEDULE
MEMBER
I MARK
I SIZE
I MATERIALI
TYPE
I THICKNESS
ILENGTH
b x t
I ALLOY
I
I W
I F
I FT.
COLUMN 1111
Cl
1 2x3-9
ALUM
1 HOLLOW
0.090
0.090
7'-3"
1 CALCULATION
COLUMN # 2
C2
3x3-9
ALUM
TUBE
0.090
0.090
7'-3"
CALCULATION
GIRT#1
G1
2x3
ALUM
HOLLOW
1 0.050
0.050
4'-6"
CALCULATION
GIRT#2
G2
2x3
ALUM
HOLLOW
0.050
0.050
5'-6"
CALCULATION
NOTE: COLUMN #2 WILL BE ATTACHED TO THE SIDE OF THE KNEE WALL.
TABLE 2 MAIN COMPONENTS SCHEDULE
COMPONENT
MANUFACMTPUO /MODEL
#-PRODUCT
APPROVAL
RATED MAX.
PRESSURE SIZE
INSTALLATION
1INSTRUCTIONS
HVHZ PRESSURE
RATED REQUIRED
8150 SERIES, HZ. SLIDERS
FL4093.2-R6
+1-40 PSF
54"x59"
DWG. # CWS-234D
NO +31.8 /-39.7 PSF
CUSTOM WINDOW SYSTEMS
8150 SERIES, HZ. SLIDERS
93.2-R
++1- 40 PSF
66"x59"
DWG. # CWS-234D
NO +31.51-38.9 PSF
CUSTOM WINDOW SYSTEMS
820 SERIES, FIXED WINDOW
EF15802.1-R7
+1- 60 PSF
54"x24"
DWG. #CWS-814A
NO +33.51-43.5 PSF
CUSTOM WINDOW SYSTEMS
820 SERIES, FIXED WINDOW
FL75802.1-R1
+/- 60 PSF
66"x24"
DWG. # CWS-814A
NO +33.41-41.9 PSF
CUSTOM WINDOW SYSTEMS
NOTE: THE WINDOWS IN TABLE 2 CAN BE REPLACED WITH OTHER WINDOWS AND DOORS PROVIDING THE FLORIDA
PRODUCT APPROVAL FOR THE OTHER DOORS AND WINDOWS MEETS THE REQUIRED PRESSURE RATING.
ADDITIONAL SITE SPECIFIC INFORMATION
THIS SECOND STORY SUN ROOM ENCLOSURE IS LOCATED IN A RESIDENTIAL COMMUNITY EAST OF ROUTE 1 AND
UNDER THE EXPOSURE CATEGORIES LISTED IN SECTION 1609.4.3 OF THE FLORIDA BUILDING CODE.THIS ENCLOSURE
THIS LOCATION IS DICTATED BY A WIND SPEED OF 160 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE
ARE 160 MPH WIND LOAD, EXPOSURE C, RISK CATEGORY II.
THE EXISTING PORCH IS BEING TRANSFORMED INTO A GLASS SUN ROOM BY INSTALLING SLIDING GLASS WINDOWS
AND DEADLIGHT WINDOWS BELOW THE SLIDERS. THE SLIDING GLASS WINDOWS AND DEADLIGHTS ARE SHOWN IN
TABLE 2 ABOVE. THIS GLASS PORCH SUN ROOM ENCLOSURE MEETS THE REQUIREMENTS FOR A CATEGORY III SUN
ROOM PER SECTION 2002.6 OF THE FLORIDA BUILDING CODE, AS SHOWN ON SHEET 2. HENCE THE SPACE, IS
CLASSIFIED AS "NON -INHABITABLE AND UNCONDITIONED".
THE EXISTING CONCRETE PORCH SURFACE, A NOMINAL 4" SLAB, THE ORIGINAL PORCH SLAB, IS PART OF THE
THESE NEW GLASS WINDOWS AND THE DOOR WILL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS. ADDITIONAL CONNECTION DETAILS ARE SHOWN ON SHEET 3.
THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 AND 20 OF THE FL.ORIDA BUILDING CODE (FBC),
EDITION 2010, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A. THE AAF
STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR TABLE 1 ARE ALSO APPLIED.
A DESIGN BASICS: THIS SCREEN ENCLOSURE IS A RISK CATEGORY II STRUCTURE. HEIGHT T-4", 160 MPH, EXP.'C'
B WIND IMPORTANCE FACTOR (0.77) AND BUILDING CLASSIFICATION RISK CATEGORY FROM FBC, TABLE 1604.5 AND
AREA LOCATION WIND SPEED PER FBC, FIGURE 1609C. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10.
C COMPONENT AND CLADDING DESIGN PRESSURE FOR WINDOWS AND DOORS: THE ULTIMATE DESIGN WIND SPEED, Vult, IS
FOUND IN FIGURE 1609A IN FBC. THE Vult IS USED TO FIND THE TO FIND THE NOMINAL DESIGN WIND SPEED, Vasd, IN TABLE
1609.3.1 IN THE FBC. THE Vasd IS USED TO FIND THE ALLOWABLE DESIGN PRESSURE, Pasd, FOR THE WINDOWS AND DOORS
IN FIGURE 30.5-1 IN ASCE 7-10. THESE ALLOWABLE DESIGN PRESSURES ARE LISTED IN TABLE 2 FOR EACH SIZE ITEM.
D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD.
E ALLOWABLE DEFLECTION: L 1120 MAXIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC.
F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES.
THE ALLOWABLE STRESS PRESSURES ARE FOUND IN ASCE 7-10 USING THE NOMINAL DESIGN WIND SPEED THAT HAS BEEN
DERIVED FROM THE ULTIMATE DESIGN WIND SPEED IN FIGURE 1609A USING TABLE 1609.3.1 OR EQUATION 16-32 OF THE FBC.
MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD):
A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE.
B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR
300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF
DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS.
ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY
INSTALLATIONS UTILIZING THE SUBJECT METHODS.
C SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58 % OPEN MINIMUM.
OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION.
D PANES OF GLASS > 9 SQ. FT. AND WITHIN 24" OF A DOOR OR WITHIN 18" FROM THE FLOOR SHALL BE TEMPERED GLASS.
E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME.
G WHEREVER SCREENING OR KICK PLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT
SCREENING OR KICK PLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER.
H ALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER.
3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS,
COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS,
ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE
IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL -CONNECTIONS SHALL MEET THE
FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR.
4 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL, PLUMBING,
ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT.
5 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN
ANY TWO BEAMS MUST BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE
AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C.
6 WHENEVER AN ALUMINUM COLUMN IS BEING ATTACHED TO A WOOD DECK, USE THE SAME SIZE WOOD SCREW, WITH
WASHER, INSTEAD OF THE SHEET METAL SCREWS CALLED FOR ON THE CONNECTION DRAWING.
7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS:
A THE SLAB MUST BE IN GOOD CONDITION, 3-1/2" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER
B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2".
8 ALL NEW SLABS, WITH OR WITHOUT PERIMETER FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A 4" (MIN.) NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER, WHERE IT ABUTS LIVING QUARTERS,
B 4" (MIN.) NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN) WITH FIBER MESH OR REBAR / WIRE.
9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A PERIMETER FOOTER REQUIRES THE SOIL BE WELL COMPACTED PRIOR TO POURING FOOTER WITH CONCRETE @ 3000 PSI,
B ONE #5 REBAR FOR 8" X 8" (MINIMUM) AND TWO #5 REBAR FOR LARGER FOOTERS,
10 ALL NEW SLABS WITH PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A ALL REQUIREMENTS OF ITEMS 9 AND 10 ABOVE,
B ALL PERIMETER FOOTERS AND CONCRETE SLABS SHALL BE MONOLITHICALLY POURED.
11 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL,
PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT.
12 ON THE ATTACHED SHEETS THERE ARE DIFFERENT CONNECTIONS THAT MAY BE USED FOR THE SAME PURPOSE. THE BUILDERS
CAN CHOOSE THEIR PREFERENCE. IF ADDITIONAL CONNECTIONS ARE DESIRED, PLEASE CONTACT THE ENGINEER OF RECORD.
GLASS ENCLOSURE
DWG. # TCAP-2015-401, REV. 1
March 6, 2015
SHEET 1 OF 3
GENERIC DESIGN DATA
TREASURE COAST ALUM. PROD.
3 SANTA FE LANE
PORT ST. LUCIE, FL 34952
OFFICE/FAX (772) 336-5329
CELL (772) 201-2111
NAME:
SAVASTANO RESIDENCE
ADDRESS:
19 LAKE VISTA TRAIL #207
CITY/STATE:
PORT ST. LUCIE,FL 34952
COUNTY:
ST. LUCIE
ISION 1 IS A COMPLETE REVISION.
SHE AREp ATTACHED BUT
Y SH B AIV'2 ARE AFFECTED.
St. Lucie County
THIS DRAWING IS ONLY ACCEPTABLE
FOR BUILDING PERMITS 8 ONLY WHEN IT
HAS THE ENGINEER OF RECORD'S RAISED
SEAL. COPIES ARE NOT DEEMED VALID.
THIS DOCUMENT IS
R. A. DUNLEA, P.E. AND SHALL NOT BE
REPRODUCED.IN WHOLE OR IN PART
WITHOUT THE WRITTEN CONSENT OF
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
FLORIDA LIC. NO. 42835
OT H OA/r
NO. ,UeD
j Oi(�•a ATAivg
-OF a•
NAL
1:1011b9mi
HOUSE
1:18111--i:4
HOUSE
SITE SPECIFIC DRAWING
NOTE: THE GIRTS CAN BE CONNECTED TO THE 2x3x0.090 AND THE 3x3x0.090 COLUMNS WITH INTERNAL CLIPS AND
THE COLUMNS CAN BE ATTACHED TO THE HOUSE (TOP & BOTTOM) WITH SCREW BOSSES AS SHOWN ON SHEET 3.
SECOND STORY PORCH ROOF
PLAN VIEW
II I I 11 11 1 1
d'-6" 2" 4'-6" 2" 4'-6" 2" 4'-6" 3"
FRONT ELEVATION VIEW
5'-10"
3"
4'-11" 2'-0"
7'-3"
RIGHT SIDE ELEVATION VIEW
1"
SUN ROOM CALCULATION:
TOTAL ROOM WALL AREA=
FRONT WALL (18.83x7.25) = 13652 SQ.FT.
LEFT WALL (HOUSE) = 0.0 SQ.FT.
RIGHT WALL (5.83x7.25) = 42.27 SQ.FT.
TOTAL ROOM WALL AREA= 178.79 SQ. FT.
GLASS ENCLOSURE
DWG. # TCAP-2015-401, REV. 1
March 6, 2015
SHEET 2 OF 3
SITE DESIGN DRAWING
HEIGHT T-4", 160 MPH, EXP.'C'
TREASURE COAST ALUM. PROD.
3 SANTA FE LANE
PORT ST. LUCIE, FL 34952
OFFICE/FAX (772) 336-5329
19 LAKE
FL
:us17L` "
DRAWINGS NOT TO SCALE
PLAXS A,YD ALL PROPORED WORT
SUBJECT TO ANY COIMECTIONS
IRED BY FIELD INSPECMFS THAT
Y BE NECFSSANY IN OI4m TO
LY WITH ALL APPLICABLE CODES,
TOTAL GLASS AREA = ' hp At>C� �11GOPk1FMINERS ORATTACHOM
FRONT WALL 4x(4.5x4.92) = 124.56 SQ.FT. µR�l�B�Y11 VfTHE
LEFT WALL (HOUSE) = 0.00 SQ.FT. T
RIGHT WALL (5.5x4.92)+(5.5x2.0) = 38.06 SQ.FT. QF�
TOTAL GLASS AREA= 162.62 SQ.FT.
HENCE, THE PERCENTAGE OF GLASS AREA FOR
THIS ROOM = (162.62/178.79) = 90.96%, WHICH IS
ACCEPTABLE FOR THIS CATEGORY III SUN ROOM.
ST. LUCIE COUNTY
BUILDING DIVISION
FOR
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
FLORIDA LIC. NO. 42835
OTH Otyy
7nT,),
00'
p° 4/
�eOy�tS •.�ORIOP °�\��°
ZONAL
GLASS ENCLOSURE
DWG. # TCAP-2015-401, REV. 1
MR�///NR;Z'
1" X 1" X 118" ANGLES
2" LONG WITH 2- #8 X 1 2 LONG March 6, 2015
"i. //J/,//�/:i �•/; ; i / /��f/'/rl/1 %�f : ' ,' , S.M.S. AT EACH LEG
NOTE-A:U`-E Yd a. ^'IONGL:CG INTO N040
TYPICAL EACH SIDE, TOP & BOTTOM 1' X 2-1/4" X 1/8"
iCS ANO '/i 9.:'/.' LONG GMGE E SCIE`NS ( ) SHEET 3 OF 3
CONC:3.�: MACONRYCONS II MC30 RECEIVING CHANNEL
CR
=MBFJMuYCONNECTION DETAILS
YFTCxl/ :
LY?"GF _aC; :E3. NOICJL>R IHE�19E:"
,• !f � f - ,I I �. -------------
HEIGHT 7'-4", 160 MPH, EXP.'C'
TREASURE L
3SANTAFELANETALUM.PROD.
Z-T10S.MS. r�CM INEIOE E4C OF I _ - _ PORT ST. LU CIE, FL 34952
2 OE INTO SC'REhV SPLINES OF 1 I , a \ 4D511Cf 11R,.
Z 0B (1- EMBEOMENTMINIMUM.) I / OFFICE/FAX (772) 336-5329
x
OB @PERIMETER /
l/ `'\—REFER TO NOTE k1 -T1115 SHEcI F.'LtiTSiY PS NOTE 'al CHANNEL ALTERNATE —/
r x 2° OR r x3° OE a U1 POSE / COLUMN
PERIMETER FASTEN PER NOTE *1 `� PASTS POST ENO PER OET-4i1 LOCATION:
t 'c Py
CONNECTCO N'M CONC EALEO FASTENERS - t NAME:
SAVASTANO RESIDENCE
PARTIAL ELEV.41 IGbIS / 1X2 TO 1rZ COI` NECTIONS E: co ADDRESS:
` CONNECTION W/ EXPOSED FASTENERS 19 LAKE VISTA TRAIL #201
X2' OR1"X3'0E@
RIMEM FASTEN PER NOTE 91
HORIZONTAL(G1RT)
NOTE 41: USE 74'9 X 3" LONG LAGS INTO WOOD
HOST AND Y4'flXZVa' LGNG CONG7ErE SCREWS
INTO CONCRETE OR MASONRYCONSTRUCTION
(1" EMBEDMENT TYPICAL)l SPACING?4' O.C. AND
WIMIN 64 OF FAOi PERFUDIO AR MEMBER
Z- 9 10 SMS. FROM ➢`LSME FAG? OFF 1 X 2
OE INTO SGLEN SRZFS OF HOLLON GIRT
(1' EMBEDMENT MMUM.)
CONNECTION W/ CONCEALED FASTENERS
PARTIAL ELEVATIONS / Z" X 2" GIRT TO 1" X 2" CONNECTIONS
4 -3 10 S.N.S. FROM INSIDE FACE OF
POST INTO SCREW SPLINES OF HOLLOW
GIRT (1-VZ° EMBEDMENT MINIMUM)
GIRT OR
FaiAIR RAIL
CONNECRON W/CONCEALED FASTENERS
PARTIAL ELEVATIONS / GIRT TO POST CONNECTIONS
Z'
IL(GAT) -SELECT BY
HE FROM TABLE 1
pass's 970 PER TABLE
RY WIND ZONE
IOOGUTERAIL(GAfj -SELECT
BY WIND ZONE FROM TABLE I
9jaccOIpL9E (DF'TIONAL)
FASTEN POST END PER DETAIL
LY2 CS SOLE PLATE UNLESS NOTED
GTHHIWISE, FASTEN TO FLOOR OR
n� O 0 �FOUNOATCIGN W/ 1/4'9 FASTENE25 V
EMBEDMENT @ Z4' O.C.- r
TYPICAL SECTIOM / SCREEN IA/ALL 'h/T THOUT CUAROP.AiL
01CTSUPP0P,I [%G R-O0 j FqjNGAI.GNOF, 8ALCOr!
ONCRETE DECK ANCHORING DETAIL
The detail to the left shall be secured with two
(2) 2" x 2" x 2" x 1/8" thick angle (Capri Clip)
w/ two (2) #14 SMS securing the angle to the
upright and two (2) securing the angle to the
base plate. The base plate shall be secured to
the slab w/ one (1) 1/4" Tapcon, embedded a
min. of 2" in the slab w/ 5/8" min. washer dia.
Tapcon must be within 6" of the upright.
EACHSIDE
.N
COLUMN I FOUNDATION FASTENER FOR 2x2 & 2x3
NOTE: LOAD CONDITIONS: CONNECTION UPLIFT CAPACITY= 1,100A, SHEAR CAPACITY=2280.
1)TOSDETAILMAYNOTBE USED FOR COLU61NS LANCER THAN V.P, 2)T"0(2)EACHXUS-DI0.BOLTS MAYBE SUBSPTU2ED FOR
THE l EACH 014 SMS (2 THRU BOLTS REPLACE 6 SCREWS) 2) CONCRETE FASTENER SPECIFICATIONS: CONCRETE FASTENERS MUST
HAVE A (MIN.) ULTIMATE ULTIMATE TENSION CAPACITY OF 2.560 S OR A WORKING (MINIMUM) TENSION CAPACITY OF 6405, AND. A
PORT ST.
PLANS MM ALL PR®POSEti WO
SIMECT TO ANY COP.RECTIONS
IRLD BY FIELD 1NSPfiCXpg THAT
I' BE NECESSAW IN OlqM TO
LY WITH ALL APPLICABLE CODES,
DRAWINGS NOT TO SCALE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
FLORIDA LIC. NO. 42835
00HOAIy
f�17
ST OF 10
'*oe.!01VAL E'<<