Name:�drl��/%gr�, INSULATION INSTALLATION CERTIFICATE
.
Permit #: /5-6,2- pl;L';� Address: fo331sE 4vJAf)V > �l font 5 Gricic
Lot: Block: Subdivision;
The undersigned hereby certifies that Insulation as been installed at the above described property as follows:
1. Exterior CBS walls have been Insulated with ( ) Spray on cellulose
which thickness, according to the manufacturer. Fi-Foil, (&+f Flberglass,blankets
(Density N/A) will yield an "R" value of 4.1. (} Aluminum Poll
(.) Other
Exterior Frame wall have been insulated with ......... O Spray on cellulose
To a thickness of 6.25 inches, which thickness, according to (&YTTbergiass blankets
the manufacturer, Certain Teed, (Density N/A) will yield an {) Aluminum Foil
" R" value of 19. {) Other
2. Ceilings— Level - have been insulated with ........, Kfiberglass blankets
to a thickness of 10.0 inches, which thickness, according to O Fiberglass loose' fill
the manufacturer, Certain Teed, (Density N/A) will yield an O Aluminum Foil
"R" value of30,
O Other Cellulose SAS
Ceilings — Cathedral — have been insulated with ...... ........ 04berglass blankets
to a thickness of 10.0 inches, which thidmess, according to () Fiberglass loose fill
the manufacturer, Certain Teed, Density (N/A) will yield an O Aluminum Foil LU
"R"value of 30. {) Other Cellulose SAB
3. Interior knee walls have been Insulated with Mai
OFiberglass blankets ORMEMM
to a thidmess of 10.0 inches, which thickness, according to O Polyurethane
the manufacturer, Certain Teed, (Density N/A) will yield an O Spray on cellulose
"R" value of 30• {:) Other LL
4. Garage partition walls of conditioned living areas have been {) fiberglass blankets
Insulated with ......... .....„. ..................... O Spray ontell ulose
to a thickness "af6 25lnches, which thickness, according to the () Polyurethane
manufacturer, Certain Teed, (Density N/A) will yield an O Other
`iR" value of 19.
MULTI -FAMILY, RESIDENTIAL CONSTRUCTION ONLY: The amnion (party) walls separating different tenants shall be insulated as
follows — Frame/Metal'stud walls 'R-11(Min); CBS or Concrete walls R-3 (Min) by Energy Code requRemerds. See Energy Code
Rev,1187, paragraph 903.2(b), on pages 9-17, latest.edition. These "minimum levels of insulation" are not Included the Energy
Calculations, but shale be installed In the field.
NOTE: Densitles of sprayed onj loose fill, orany other composed -on site insulation shall be the PCF (ibfft3) average of three (3)
"DRY SAMPLES" of actual Installation.
Print Name of Insulation Contractor Signature of insulation Contractor
Date of Certification
my (.OynM1&&IUY%
_pypjreS 5(10{202-0