VELCON GROUP, INC.
ErommRs & Suavevoas
October 05, 2015
Edmund Bas
St. Lucie County Public Works - Engineering Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Minor Site Plan Application
Family Dollar - Lennard Road
10331 SE Lennard Road, Port St. Lucie, FL 34952
S12, T37S, R40E
SCANNt,
BY
St. LUCiP Cni
Dear Mr. Bas,
We have received your constructability comments dated August 11, 2015. The following
responses correspond to the comments provided:
1. A note has been added to Sheet 1 regarding the crosswalk striping.
2. The stamped concrete section is the same as the concrete pavement section indicated on
Sheet 1. No additional detail is needed.
3. 6 of separation is demonstrated on the interference point detail. Also, there are no
minimum requirements for crossing of drainage pipe.
4. The only required cover is the amount indicated for the pavement section as this is' hot a
FDOT roadway and will receive minimal traffic when compared to a roadway. This is
standard practices -vithin private parking areas..
5. The typical pavement sections indicated on Sheet 1 and Sheet 3 have been updated so that
they are consistent with each other.
6: 9. Since all of the pavement is proposed and no work is proposed under 9xisting
pavement, the Replacement of Flexible Pavement Detail has been removed from Sheet
3.
Should you have any questions on the above, please contact, our office at your earliest
convenience.
Sincerely,
Randy R dge
The Velcon Group, Inc.
Attachments
Cc: File 12-066ENG (w/ aft)
N:\COMMERCIAL PROJECTS\12-JOBS\12-066 Family Dollar Lennard Road\SLC\Public Werks\12-0665LC PW 10-05-15.doc
"I" QvI_A(.59
Joe Cicio
From:
Sent:
To:
Subject:
Thank you, Joe.
Ernesto Velasco, P.E.
Velcon Group, Inc.
Engineers & Surveyors
772 879 0477
emestov@velcongroup.com
Ernesto Velasco <ernestov@velcongroup.com>
Tuesday, August 30, 2016 10:14 AM
Joe Cicio
RE: Family Dollar
From: Joe Cicio [mailto:cicioj@stlucieco.org]
Sent: Tuesday, August 30, 2016 9:33 AM
To: Ernesto Velasco
Cc: Joe Cicio
Subject: RE: Family Dollar
Hello Ernesto,
BCANNtL,
BY
St. Lucie Cn„n,
Our water and sewer inspections pertain to on -site piping installations. We are needing approval for the
underground water and sewer lines from the city connections to the building . These were previously covered and not
left open for our inspectors. We need an original letter of approval for plan compliance and compliance with the 2014
fbc [ plumbing ]
Thank You
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
St Lue i,& C.ou* y Fla.vuti.i" a*L& DevelorAv4,K+ServUz:s
AUG 3 1 RECD
How ** Flease-cowvta.ot-Corl. Fefe-rso%ti, 13v-i .oLi,ng OffusiaL a,l-
p� o�vy@ghy4Aeeoorg iv-w your wuggeyhowy, a*td. feeAbac ,.
From: Ernesto Velasco [mailto:ernestov@velcongroup.com]
Sent: Tuesday, August 30, 2016 9:19 AM
To: Joe Cicio <cicioj@stlucieco.org>
Subject: Family Dollar
.ld
Good morning Joe,
Hope all is well.
I am reaching out to you at the request of Garrett Almond, with Hutton Construction, who is in charge of the Family
Dollar project on Lennard Road.
He had shown me paperwork with open/pending items with regard to his permit status with the County, and in
particular, water and sewer service to the site. As you know, the project is serviced by the City of Port St. Lucie Utilities
Department. The contractor is in the process of finalizing installation of the station and our paperwork and certification
to the City should be finished, hopefully, sometime in the next month.
Please let me know if we need to provide paperwork to you in order to close the project out with St. Lucie County.
Thank you,
Ernesto
Ernesto Velasco, P.E.
Velcon Group, Inc.
Engineers & Surveyors
772 879 0477
ernestov onvelconproup.com
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
N
Joe Cicio
From: Frank Smith <fsmith@castlesdesigngroup.com>
Sent: Monday, September 14, 2015 11:16 AM SC NNEG
To: Joe Cicio
By
Cc: 'Steven Pratt' St.�UCIp rnij,,,
Subject: RE: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
I apologized, I haven't heard back from you regarding the storefront issue. We are moving closing to resubmitting the
project and do not want this item to be the one holding us back.
Hope you had a great weekend,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith@castle sdesigngroup.com
From: Frank Smith [mailto:fsmith@castlesdesigngroup.comj
Sent: Thursday, September 10, 2015 9:48 AM
To: ,Joe Cicio <cicioj@stlucieco.org>
Cc: 'Steven Pratt' <spratt@castlesdesigngroup.com>
Subject: FW: Family Dollar- Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
Thank you for the help.
We had a conversation with Kawneer in regard to the storefront system needed to use for Family Dollar— Lennard
Road/Port St Lucie, Florida project. They sent over the product information on both the glazing and storefront system
(attached) and indicated that these systems work correctly for the application and in compliance with the requirements
for the NOA compliance. I asked them to confirm the requirements for testing of the storefront with recommended
glazing approved in the NOA.
Kawneer referred me to Section F. STATEMENTS paragraph 1 which outlines the confirmation in the NOA utilized the
glazing in Section E. MATERIAL CERTIFICATIONS. Both the Storefront and the glazing have the same statement.
I did refer to your example NOA 12-1106.05 and I looked at FL# 8787-R5. FL# 8787-115 had the exact storefront system
from Kawneer I had send in the previous email (and attached).
With the attached PDF, will this be approved for our project?
Thanks,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith@castiesdesigngroup.com
From: Joe Cicio [mailto:cicioi@stlucieco.orgl
Sent: Wednesday, August 26, 2015 3:42 PM
To:'FrankSmith' <fsmith@castlesdesigngroup.com>
Subject: FW: Family Dollar- Port St Lucie, FL- Permit No: 1502-0127
Frank,
Look at FL# 8787-115 to see if that helps you
Thanks
Joe
From: Joe Cicio
Sent: Wednesday, August 26, 2015 4:35 PM
To: 'Frank Smith'
Cc: Joe Cicio
Subject: RE: Family Dollar- Port St Lucie, FL - Permit No: 1502-0127'
Good Afternoon Frank,
We, here in St Lucie County, have adopted the Florida Building Code library and are currently enforcing the 2014
5ch edition . We review the codes and manufacturers product approvals for compliance. In review of the testing you have
sent the aluminum storefront framing system would be o.k. however the other N.O.A. is for the interlayer testing only.
The notes state that the interlayer by itself does not comply with the Florida Building Code . The complete storefront
system must be engineered as 1 assembly being impact resistant. The other issue would be the design pressures as
required by your design professional.
I would need to see the complete testing for the laminated glass w/ frames, then your engineer would put the
glass and frames together on the plans to show a complete assembly. [[[ EXAMPLE ONLY ]]] see NOA 13-1106.05 as you
will see the complete assembly, glazing options, spans etc
Thank You
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
Sf L.u.ci e. Cov-+4y PLahu%Z" a v& Pevetopywzft4-Se rvi,
From: Frank Smith [mailto:fsmith@castlesdesigngroup.coml
Sent: Wednesday, August 26, 2015 2:38 PM
To: Joe Cicio
Cc: 'Steven Pratt'; Igililung@castlesdesigngroup.com
Subject: Family Dollar- Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
I talked to our storefront supplier Kawneer about which model would work at Port St. Lucie and they directed me to
their IR 501. The storefront system calls out, as one of the options for glazing, the Saflex. As it was explained to me by
the Kawneer and the glazing provider that as a whole the storefront and glazing meets the L.M.I. rating required by the
county.
My question is, will this meet the proper county requirements?
Thanks,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith(c@castlesdesigngroup.com
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and I
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Lydia Galbraith
From:
Jeffrey Johnson
Sent:
Tuesday, February 17, 2015 11:39 AM
To:
Lydia Galbraith
Cc:
Leslie Olson
Subject:
FW: Family dollar (FD-Lennard Road)
Lydia —See comment below from PSL re architecture
Thx, Jeff
From: Bridget Kean [mailto:BKean@cityofpsl.com]
Sent: Thursday, November 06, 2014 10:01 AM
To: Jeffrey Johnson
Cc: 'ernestov@velcongroup.com'
Subject: FW: Family dollar (FD-Lennard Road)
SCANNED
BY
St. Lucie Countv
Hi Jeffrey,
I do not have any additional comments on this project. Under our Code, the sign face should match the color of the
building. I think that has been straightened out. Let me know if you need anything else.
Bridget Kean, AICP
Community Redevelopment Agency Director
City of Port St Lucie
121 SW Port St. Lucie Blvd.
Port St. Lucie, FL 34984-5099
772-873-6489(Phone) 772-871-5128(Fax)
From: Bridget Kean
Sent: Tuesday, November 04, 2014 2:35 PM
To:'Helena, Jr., Lee'
Subject: RE: Family dollar (FD-Lennard Road)
That means the individual tenant panels. The background of the sign face has to match the color of the building. It's the
same requirement that Family Dollar had to meet with the store on Prima Vista in Port St. Lucie. Below is my contact
info.
Bridget Kean, AICP
Community Redevelopment Agency Director
City of Port St. Lucie
121 SW Port St. Lucie Blvd.
Port St. Lucie, FL 34984-5099
772-873-6489 (Phone) 772-871-5128(Fax)
From: Helena, Jr., Lee [mailto:lhelena@hutton.buildl
Sent: Tuesday, November 04, 2014 2:01 PM
To: Bridget Kean
Subject: RE: Family dollar (FD-Lennard Road)
Hi Bridget,
Sorry I don't have your phone number to discuss. The last part of that sentence says that it does not
apply to single tenant panels. That is what we are applying for, a single tenant monument panel.
Lee Helena
Development Project Manager
Human
736 Cherry Street
Chattanooga, TN 37402
423-643-9202 Office
423-664-7100 Fax
843-592-5136 Cell
Ihelena@hutton.build
http://hutton.build
Disclaimer: The content of this e-mail is intended solely for the use of the Individual or entity to whom it is addressed. If you have received this communication in
error, be aware that forwarding it, copying it, or in any way disclosing its content to any other person, is strictly prohibited. If you have received this communication
in error, please notify the author by replying to this e-mail immediately.
From: Bridget Kean [mailto:BKean@citvofpsl.coml
Sent: Tuesday, November 04, 20141:52 PM
To: Helena, Jr., Lee
Subject: RE: Family dollar (FD-Lennard Road)
Hi,
The way the Code reads, the sign face has to match the color of the building.
Freestanding (monument) signs.
(1)
In addition to other city codes, the following standards shall apply:
(a)
101
(e)
(b)
(c)
Signs shall be compatible with the architecture of the building (colors, materials).
Use a minimum six-inch and a maximum twenty -four -inch letter height for all signs. At least one line
must comply with the minimum requirement.
Identify the business name/logo and type of business on tenant signs. Corporate logo and color are
permitted on sign. Corporate logo may be thirty-six (36) inches, but must be included in sign calculation.
Phone numbers and e-mail addresses are not permitted on freestanding signs.
Locate sign perpendicular to the street.
Utilizing color of building on sign face, use no more than three colors on one sign face. This does not apply to
individual tenant panels.
From: Helena, Jr., Lee [mailto:lhelenaf_dhutton.buildl
Sent: Tuesday, November 04, 20141:48 PM
To: Bridget Kean
Cc: Ernesto Velasco; randvr@velcongroup.com
Subject: RE: Family dollar (FD-Lennard Road)
Bridget,
Thank you, but I think I worded one thing wrong. Our signage vendor just clarified that the comment
he received was that the base of the monument sign is to to be painted to match the building, not the
background. He already updated his submittal renderings last week.
I've revised the letter for your records and attached the revised monument sign rendering. I apologize
for the confusion.
Thanks -
Lee Helena
Development Project Manager
736 Cherry Street
Chattanooga, TN 37402
423-643-9202 Office
423-664-7100 Fax
843-592-5136 Cell
Ihelena@hutton.build
htto://hutton.build
Disclaimer. The content of this e-mail is intended solely for the use of the Individual or entity to whom it is addressed. If you have received this communication in
error, be aware that forwarding it, copying it, or in any way disclosing its content to any other person, is strictly prohibited. If you have received this communication
in error, please notify the author by replying to this e-mail immediately_
From: Bridget Kean [mailto:BKean@cityofpsl.com]
Sent: Tuesday, November 04, 20141:04 PM
To: Helena, Jr., Lee
Subject: RE: Family dollar (FD-Lennard Road)
That is fine. Thank you.
From: Helena, Jr., Lee [mailto:lhelena@hutton.build]
Sent: Tuesday, November 04, 2014 7:09 AM
To: Bridget Kean
Cc: Ernesto Velasco; randvr@velcongroup.com
Subject: RE: Family dollar (FD-Lennard Road)
Bridget,
Please review the attached letter and let me know if this is what you are looking for.
Thanks-
Lee Helena
Development Project Manager
Hutton
736 Cherry Street
Chattanooga, TN 37402
423-643-9202 Office
423-664-7100 Fax
843-592-5136 Cell
Ihelena(- hutton.build
htto: //hutton. build
Disclaimer: The content of this e-mail is intended solely for the use of the Individual or entity to whom it is addressed. If you have received this communication in
error, be aware that forwarding it, copying it, or in any way disclosing its content to any other person, is strictly prohibited. If you have received this communication
in error, please notify the author by replying to this e-mail immediately.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Lydia Galbraith
From:
Mike Halter
Sent:
Tuesday, February 17, 2015 11:30 AM
To:
Lydia Galbraith
Subject:
RE: family dollar, 10331 Lennard Rd. PDS 14-048
Lydia,
Yes, I have application and sent permit.
Thanks
Michael
2719
From: Lydia Galbraith
Sent: Tuesday, February 17, 2015 11:27 AM
To: Mike Halter
Subject: family dollar, 10331 Lennard Rd. PDS 14-048
Mike,
Do they need a stormwater permit?
Have they applied yet?
Thanks,
L_IUdta calbratth
Planning & Development Services
(772)462-1555
palbraithlna stlucieco.org
SCANNED
BY
St. Lucip. Count,
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and 1
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
P
Joe Cido
From: Steven Pratt <spratt@castlesdesigngroup.com>
Sent: Friday, March 27, 2015 3:00 PM
To: Joe Cicio SCANNED
Cc: 'Larry Christian'; Lisa Gililung BY
Subject: (1502-0127) Family Dollar - Lennard Road/Port St Lucie, FLSt LUCip r n, ^
Joe,
Thank you for taking my call today — please see my contact information below for your use in sending me the plan
review comments.
Have a great day!
Steven Pratt
CASTLES DESIGN GROUP, P.C.
A Professional Architectural Corporation
architecture since 1952
3801 Kirby Drive, Suite 600
Houston, Texas 77098
Tel.: 713.664.7974 x1319
Fax.: 713.664.9756
Cel: 832.978.6575
Web.: htto://www.castiesdesigngrouo.com
To send me files, CLICK HERE.
April 30, 2015
HUTTON CONSTRUCTION INC
736 CHERRY ST
CHATTANOOGA, TN 37402-1909
14-B-83134
THE HUTTON COMPANY
PORT SAINT LUCIE, FL
MULTIPLE BUILDINGS
To Whom It May Concern:
ACCREDITED
AC472
SCANNED
St. Lucie By
This. is to certify that materials for the subject structure have been designed in
accordance with the order documents, specifically as shown per the attached
Engineering Design Criteria Sheet.
Aspects of code compliance as related to use or occupancy, such as sprinkler
requirements, are not addressed by these documents.
These materials, when properly erected on an adequate foundation in accordance with
the erection drawings as supplied and using the components as furnished, will meet
the attached loading requirements.
This certification does not cover field modifications or the design of materials
not furnished by Mesco Building Solutions.
The attached design criteria information is to remain with and form .part of this
Letter of Certification.
The calculations and the metal building they represent are the product of Mesco
Building Solutions or a division of its affiliate NCI Building Systems. The
engineer whose seal appears hereon is employed by either Mesco Building Solutions
or a division of.its affiliate NCI Building Systems and is not the engineer of
record for this project.
Cordially,
Mesco Building Solutions
May0arials for Metal Buildings
May 12015 2:29 � Y pMjO&V.*
WA
Harley Davidson, P.E. ^ y •, t %
Design Manager • No.38M ?(
STATE OF
14-B-83134
Pagel of 3
At
ANSCOACCREDITED
Bw1mg So/rglons' AC472
An NCI Company
Building Code ..................... 2010 Florida Building Code
Building Risk Category Normal (Risk Category II)
Roof Dead Load
Superimposed ................. 2.66 psf
Collateral ................... 3.00 psf
(0.00 psf Ceiling 3.00 psf Other)
Roof Live Load .................... 20.00 psf reduction allowed
Wind
Ultimate Wind Speed (Vult) ... 160.00 mph
Nominal Wind Speed (Vasd) .. 123 mph (IBC section 1609.3.1)
Wind Exposure Category ....... C
Internal Pressure Coef (GCpi) 0.18/-0.18
Loads for components not provided by building manufacturer
Corner Areas (within 6.88' of corner) 52.56 psf pressure -70.08 psf suction
Other Areas 52.56 psf pressure -56.94 psf suction
These values are the maximum values required based on a 10 sq ft area.
Components with larger areas may have lower wind loads.
14-B-83134 Page 2 of 3
k
A%�
ANOWACCREDITED
saildIngsolutions- AC472
An NCI Company
Florida
The material supplied by the manufacturer has been designed with
the following minimum deflection criteria. The actual deflection
may be less depending on actual load and actual member length.
BUILDING DEFLECTION LIMITS...: BLDG-A
Roof Limits
Rafters
Purlins
Panels
Live L/
180
150
60
Snow L/
180
180
60
Wind L/
180
180
60
Total Gravity L/
120
120
60
Total Uplift L/
N/A
N/A
60
Frame Limits
Sidesway
Portal
Frame
Sidesway
Live H/
120
Snow H/
120
Wind H/
120
Seismic Drift H/
67
67
Crane H/
100
Total Gravity H/
120
Total Wind H/
120
60
Service Seismic H/
120
50
Wall Limits Limit
Total Wind Panels L/ 60
Total Wind Girts L/ 240
Total Wind EW Columns L/ 120
The Service Seismic limit as shown here is at service level loads.
14-B-83134 Page 3 of 3
Family Dollar
10331 Lennard Road
Port Saint Lucie, Florida
June 11, 2015 n Proposal No. PHD150185
EXHIBIT A —SCOPE OF SERVICES
SPECIAL INSPECTIONS SCANNED
BY
Cast -in -Place Concrete St. Lucie COunti.
• Check formwork for shape, location, and dimensions of the concrete member being formed.
• Observe placement of reinforcing steel, clearances, anchor bolts and embedments.
Masonry
As masonry construction begins, the following shall be observed:
Spot check mortar mix proportions.
Construction of mortar joints;
Location, specified size, grade and type of reinforcement and location of connectors.
Prior to grouting, the following will be observed:
• Grout, space is clean;
Placement of reinforcement and connectors;
Constructed mortar joints.
Structural Steel
• Review size, material, location, member orientation, and presence of connections.
• Confirm that field welding is being performed by welders with current qualifications.
Observe, test and report bolted and welded connections as shown below.
Structural Steel Welded & Bolted Connection Observations
A State of Florida Certified Standard Building Inspector will perform periodic field, inspection of the on -site
welded and bolted components. Inspection will consist of visual inspection of field -welded connections
and testing of field -bolted connections. The following tests and observations will be performed, where
required by project specifications:
• Review of welder qualification papers per AWS D.1.1-2010.
• Perform visual inspection of completed field welds per table 6.1 of ASWD1.1-2010 during
periodic site visits.
• Perform visual inspection of high -strength bolted connections for installation and hardware.
It is assumed that the contractor will provide a scissor lift (or OSHA approved safety cable system), and/or
aerial lift for welding and boiling inspections; as needed. It is the responsibility of the General
Contractor/Sub-contractor to have all slag removed from welds prior to our inspection.
During construction, Terracon will need to be provided with two complete copies of all current/revised
drawings, details, specifications, Requests for Information and any other clarifying or modifying
communication that .affect our portion of the work. We would also like the opportunity to attend pre -
construction meetings during which issues related to our scope of work may be discussed.
Family Dollar
10331 Lennard Road
Port Saint Lucie., Florida
June 11. 2015 c Proposal No. PHD150185
a
EXHIBIT A —SCOPE OF SERVICES
In addition, we specifically request to be provided with one copy of approved submittals for work performed in
the following categories:
1. Masonry (including CMU block, joint reinforcing, mortar and grout materials)
2. Reinforced Concrete (including approved mix designs and intended usesfiocafions)
3. Structural Steel (including shop and erection drawings)
Ourservice does not include inspection of any safety provisions required by OSHA or other safety standards,
which apply during the construction period.. Nor does it apply to other non- load bearingelements such as
glass, „metal or wood, railings, fire protection, roofing, rnechanicallelectrical systems, . architectural
components, site work or other elements not contributing to the structural capacity of the building frame.
It is not the special inspector's responsibility to provide quality control for the contractor. The inspector or his
agent will verify that non-compliance issues have been resolved within the scope of services, if accessible
and readily visible. Requests for additional time spent beyond our initial inspection will be considered
additional services. Similarly,, the contractor will endeavor.to have segments for threshold inspection ready
for final inspection at the time of notification and not request inspections on a repeated preliminary inspection
basis. If necessary, re -inspection services shall be provided by the authorized representative of the special'
inspector at the applicable rate of the field representative and for the special inspector.
Special inspections do not relieve the contractor of his responsibility to comply with the contract documents,
any statutory or contractual obligations, nor his responsibilities to carry out his quality control inspections and
testing. The contractor has the sole responsibility for any deviations from the official contract documents and
the costs of rectifying those deviations.
Under Florida Statutes, Chapter553, the Special Inspector is charged with certain inspections of structural
components of a defined threshold building. The inspections are to be performed in accordance with the
approved and filed Threshold Inspection Plan as prepared by the Structural Engineer.of Record. While the
inspections performed by the Special Inspector are under the guidance and auspices of the appropriate
building code or reference code, it is not the task of the :Special Inspector to either determine or certify
compliance of the building, in general, with the building code. Compliance with the building code is the
responsibility of the designers, in concert with the general contractor.
We anticipate submitting regular reports to the project team. We will also prepare a Concluding Report of
Special Inspections and submit it to the Building Department, Owner and other designated parties following
the last required site visit and resolution of outstanding discrepancies.
2
NMCO BUILDING SOLUTIONS
Corporate Office
5244 BaarCreekCowt
Irving, TX 75061
214-687-9999
800.556-3726 TOLL FREE
214-687-9741 FAX
June 23, 2015
Hutton Construction, Inc.
736 Cherry Street
Chattanooga, TN 37402
Re: Mesco Order#14-B-11MM
Project: Family Dollar
Gentlemen:
AN
AKSCO
Building Solutions"
MESCO BUILDING SOLUTIONS
Eastern Regional Office
107 2ndAve. SE
Cufiman,AL 35055
256-734-6514
866-279-9696 TOLL FREE
256-734-6734 FAX
SCANNED
BY
St. Lucie Countv
The referenced order was originally to be manufactured by Bigbee, but now is designed
and manufactured by Mesco Building Solutions, also all previous comments from the
city have been addressed.
Please let me know if you have any questions regarding this.
\\UUillitPtlJlryrr
\\ rr
a WC
�.
i�irrrr0l� ITEILyN'�'\`\.�OO
\`�4��rG� UAI//oS/��
No.3g305 :d
:U
of-
-We Find A Way"
H n
REAL ESTATE DEVELOPMENT CONSTRUCTION
We Di$.
June 26, 2015
St. Lucie County
Planning & Development Services
Building & Code Regulation Division
2300 Virginia, Avenue
Fort Pierce, FL 34982
RE: Permit No. 1502-0127
Family Dollar
10331 Lennard Rd
Port St Lucie, FL 34952
Mr. CUD,
In response to your plan review comments, please let this letter serve as notice that Hutton has
hired Terracon to perform all required special inspections associated with this project. I have
attached Hutton's contract with Terracon and also a list of inspectors who will be performing
the field inspections for your reference. Please feel free to contact me with any questions or
concerns.
Sincerely,
Jeff toi
Development Project Manager
STAU
OF 1(NEESM
MOTARY
�L PUSua"00
1/vVt GprAl�WIiSSO✓� ejE.'ectS: �'� ���
736 Cherry St Chattanooga, TN 37402 Phone: 423-756-9261 Fax:.423-756-7927 http://hutton.build
9neseree.�®
1743 South La Cienega Blvd.
Los Angeles CA 900354601
T - 310.837:0526
F - 310.837.0523
To: Whom It May Concern
Re: greenscreenTm General Engineering Information
-PANEL WEIGHT -
SCANNED
St i BY
urip County
The 3" thick panels weigh .66 pounds per square foot. #5104 trim adds .50 pounds per lineal foot and #5105 trim
adds .30 pounds per lineal foot.
The weight of plant materials grown on the panels is an issue that has been analyzed on previously completed
projects. There are a number of variables that affect the overall weight; including type of plant material, level of
maturity, and moisture content. We have taken what we assume to be the worst case scenario which accounts for
panel weight with full perimeter #5104 trim and fully mature vines on a cold wet day. In this case it has been our
experience that this weight would never exceed 5 pounds per square foot.
-PANEL OPENESS-
It has been calculated that a standard 4' x 8' panel without any plant growth gives 8.25% coverage in elevation,
meaning the panel is 91.75% open. However, most building departments consider the panel solid when fully
covered with mature plant material.
-GUARD-RAIL CONDITIONS -
Post mounted greenscreen panels do not meet typical code requirements for a guard-rail Most city codes require
a concentrated load resistance of 250 Ibs for a 42" high guard-rail. greenscreen panels only meet the in -fill
requirement for uniform load resistance of 50 Ibs/sq. ft. For guard-rail applications, a steel frame should be designed
by a project engineer and fabricated by a local steel.shop; greenscreen can then supply the infill panels. If
preliminary drawings are provided, greenscreeh can advise on mounting details and value engineering
suggestions.
-WIND EFFECTS ON PANELS -
It is assumed that plant material is frangible and will blow off in a mild wind long before hurricane speeds are
reached (A 140 mph 3 second gust is considered to be a low category 3 hurricane.) What this means is that as the
wind blows harder it will remove more and more plant material, thereby controlling the amount of lateral wind
pressure to an indeterminate amount. Furthermore, loss of plant material will also decrease the vertical load on the
mounting clips more and more as wind speeds increase. Lastly, it should be noted that the Gcpi (internal pressure
coefficient) is 0 when considering an Exposure C location.
-PANELS ARE NOT CLADDING -
The panels do NOT meet the definitions of "Main Wind Force Resisting Systems" or "Components and Cladding"
(Building Envelope)'as given in section 6.2 of ASCE 7-2005. This means that the panels are not required to be
designed for wind.
greenscreen®) aninnovative J unique modular trellising system Page 1 of 2
Contad us at 800.AS0.3 IPIcr salea@greens,reen.com IN REOUESTA QUOTE(hhpglgmensemen.coMequest-a-quotel
(mailto:salesgigreensneen.mm)
greenscreen° Company Products Projects Users Resources Installation Plants News OL
The Possibilities are Endless!
greenscreen@ is a three-dimensional modular trellis system providing you with endless
combinations for creating green facades, freestanding elements, shapes and fencing.
greenscreen® can transform space or define it... act as a wall, change a facade or
create an environment.
Access Your Path to a Perfect greenscreen® Solution.
Architects, Landscape Contractors and Installers Residential Customers
Architects & Designers (http://greenscreen.com/users/cor(trftpbb*eenscreen.com/users/res
(http://greenscreen.com/users/architdattersn customers/)
landscape -architects-
designersn and
ndlook over
andassemblyhere
For smaller thaltcanec eas toiscreen®Ise
and look over installation exam les here Gel a 'kit of an 'that co b 1 tall d 'gt
Discover the range of applications and project
types and team about the considerations for a
successful greenscreen® installation. Models,
drawings. details, plant guidelines and
examples are all available.
It
quote or prepare an order for your
greenscreen® installation.
Is s n e easy o ins an wi
the durability of our commercial system.
Launch here to learn more about how
greenscreen® can contribute to your solutions
for privacy screening, fencing security and
shade.
What Our Customers Are Saying
http://greenscreen.com/ 7/28/2015
greenscreen® Ian innovative - i unique modular trellising system
Page 2 of 2
1361A
greenscreen® provides the canvas and the frame to
display the seasonal color of the east, buffer the wind of
the prairie, mitigate the heat of the desert, and enhance
the rainforest of the northwest.
Randy Sharp, FCSLA, ASLA, LEER® A.P., G.R.P.
Request a Quote TELL US ABOUTYOUR PRO1ECT(Ire9uesta1uole)
CONTACT
greenscreen®
1743 S. La Cienega Blvd.
Los Angeles, CA 900354650
310.837.0526
800.450.3494
sales@greenscreen.com
(maillo:sales@greenscreen.aom)
READY TO ORDER?
Find a Product Representative or
Recommended Installer in your
area.
PRODUCTREPS
(http:llgreensereen.oemrcompanyl
representati
M1015gmensceesZ, I sic design♦Wild Sy Tomddo Design(Ltlpld .tomedodesgn.le)
DOYMMAD OUR CATALOG
samplesi)
SIGNUP FOROUR NEWSLETTER
our mailing list to receive
a about events, project
ales, and related information.
UBSCRIBE
mplleepurixomron3M)
r f t 0
http://greenscreen.com/ 7/28/2015
Joe Cicio
From:
Joe Cicio
Sent:
Wednesday, March 25, 2015 3:43 PM
To:
'Lhelena@hutton.build'
Cc:
'relliott@hutton.construction'; Joe Cido
Subject: Plan Review Comments for Permit Number 1502-0127
Attachments: Report_FL_Review_Comments_Noncompliant-jrf.pdf
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional, contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank you,
p°cAii wt. eGL6 6CAN
Plans Examiner II BY Fri
Standard Building
Building Plans E amtor
Examiner
t t /rra COUnty
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
StL_a4a ,COV-4 (y FLt*",.i," afad DeveLo�wtvr�,a Servfeey
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
July 10, 2015
St. Lucie County
Planning and Development Services
2300 Virginia Avenue
Ft. Pierce, FL.
Principals
Joe B. Hutcherson III, P.E.
Thomas L. Miller, Jr. P.E.
Quality Engineering Since 1982
JGANNED
BY
+ lJri , County
Re: SMEP Review Comments for Family Dollar 10331 Lennard Rd., Port St. Lucie, FL
Please find our responses to your comments provided during your review of the above
referenced project.
Comment
PLEASE REFER TO THE PROPER PLUMBING CODE ON SHEET T-1
Response
Plumbing code reference has been updated on sheet T-1 and Plumbing, drawings, as required.
Comment
ALL BUILDINGS AND STRUCTURES MUST BE DESIGNED TO THE 2010 FLORIDA BUILDING CODES WITH THE 2012
SUPPLEMENTS * MESCO STEEL PLANS, STRUCTURAL AND ARCHITECTURAL PLANS FROM HUTTON ARE
INCORRECTLY DESIGNED /THE WINDSPEED FOR THIS SITE WOULD BE MIN. 160 VULT EXPOSURE "c' **
MODIFY ALL PLAN PAGES, WIND LOAD COMPLIANCE SHEETS AND SUPPORTING DOCUMENTS, DESIGN
PRESSURES AS NECESSARY
Response
Structural sheet S-0.1 has been revised to indicate "2010 Florida Building Code with 2012 Supplements".
Windspeed has been revised to 160 mph "Vult". Exposure has, been revised to "C".
Comment
SUBMIT AN ORIGINAL, NOTARIZED LETTER FROM THE FEE OWNER OF THE BUILDING THAT HE/SHE HAS HIRED
THE SPECIAL INSPECTOR TO PERFORM SPECIAL INSPECTIONS ON THIS PROJECT [SEE F.S. 533.79 (4) *** SHEET
S-0.1 STATES STRUCTURAL TESTS REQUIRED BY CHAPTER 17 IBC WE ARE ENFORCING THE 2010 FLORIDA
BUILDING CODE * PLEASE IDENTIFY SCHEDULES FROM THAT CODE IF APPLICABLE * MODIFY ALL PLAN PAGES
APPLICABLE ** WE WILL REQUIRE ORGINALrSIGNED, SEALED AND DATED TEST DOCUMENTS FOR OUR FILES **
Response
References to "International Building Code" and have been deleted from sheet S-0.1. A letter from the
Owner has been provided verifying that a Special Inspector has been engaged to perform the required
Inspections on the project.
Street Address Mailing Address
310 Dodds Avenue P.O. Box 3689
Chattanooga, TN 37404 Chattanooga, TN 37404
Phone (423) 698-6675 www.marchadams.com Fax (423) 698-3638
CIVIL • STRUCTURAL • MECHANICAL • ELECTRICAL • INDUSTRIAL
March Adams & Associates, Inc. 10 July 2015
St. Lucie County
Plan review
Page 2 of 2
Comment
SHEET 5-1.1 STATES THAT FOOTING SIZES ARE ESTIMATED "STRUCTURAL P.E. TO HAVE THE BUILDABLE
FOUNDATION CRITERIA ON PLANS WITHOUT DISCLAIMER
Response
Sheet 5-1.1 has been revised to indicate that foundations have been sized based on reactions provided by
the metal building manufacturer.
Comment
NOTE 2 ON A-2.2 STATES THAT CIVIL ENGINEER WILL DETERMINE THE LOCATION AND CAPACITY OF THE
DOWNSPOUTS* PLEASE BE SURE THAT THIS ITEM GETS ADDRESSED ON THE CIVIL DRAWINGS.
Response
Plumbing sheet P1.1 has been added to the set showing both sizing and spacing of the downspouts in
lieu of being determined by Civil.
CIVIL • STRUCTURAL • MECHANICAL • ELECTRICAL • INDUSTRIAL
Galbraith
From:
Sent:
To:
Cc:
Subject:
Attachments:
Lydia,
Please see attached.
Thanks,
Edmund Bas
SLC-Engineering
Ext. 2184
Edmund Bas
Tuesday, August 11, 2015 1:11 PM
Lydia Galbraith
Linda Pendarvis; Ron Harris; Michael Powley; Craig Hauschild
FAMILY DOLLAR
Family Dollar.docx
SCANNED
BY
St, Lucie Count
N
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
1
F
Project: FAMILY DOLLAR
Permit #1502-0127
Subject: REVIEW COMMENT
To: Lydia Galbraith
From: Edmund Bas
PW-Engineering Division
August 11, 2015
CONSTRUCTION PLAN:
1. On Sheet #1, please label the crosswalk pavement marking on the southeast portion of the
parking lot.
2. On Sheet #1, please provide a Typical Section of the Stamped Concrete.
3. On Sheet #2, INTERFERENCE POINT #4, it seems the 6" minimum separation is not achieved.
Please verify.
4. On Sheet #2, Structures SD #2 and SD #3, it seems there is not enough cover height from the
top of the pipe to the bottom of the pavement base. Please refer to the FDOT Design Standards
for Cover Height requirements.
5. On Sheet #3, the Typical Pavement Sections do not match the Typical Pavement Sections
shown on Sheet #1.
6. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, the overlap of the proposed
asphalt to the existing asphalt should be consistent with the ASPHALT PAVEMENT SAWCUT
& BUTT JOINT DETAIL.
7. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, please indicate the compaction
requirements of the base and the backfill materials around the pipe.
8. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, General Note #1, please verify
if this requirement can be achieved with the proposed invert elevations of the pipe.
9. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, General Notes #1, please
correct the spelling of the word "ORIGINAL".
zi Joe Cicio /SCj % O/Z,%
From: Perini III, -Lou R. <Lou.Perini@terracon.com>
-i Sent: Monday, September 19, 2016 3:25 PM
To: Joe Cicio
Cc: jtroutner@huttonconstruction.com';'Almond, Garrett'; Youngstrom, David T.; O'Connor,
Mike J.
Subject: Family Dollar / Metal Building / Lennard Road / PSL / Tin Tag Report
SCANNED
BY
St. Lucie County
Good afternoon,
Inspection report number 71 delivered to The building department by the permit applicant Hutton Construction is the
dry in report.
Please read the notes in report #71, 1 noted dry in as requested by Garrett from Hutton Construction as he informed me
','•^;z` you were looking for that.
No tin tag exists for this type of metal building construction nor per the metal building manufacturers installation
instructions.
.-.The metal building manufacturer official construction documents on site call for a metal roof purlin bolted to the
structural steel superstructure.
Once the roof purlins are bolted down to the roof framing beams, the insulation in draped overthe roof purlins and then
.:'metal roof panels installed and crimped overthe insulation, that is the manufacturer installation instructions as was
inspected and reported to.
I informed Hutton Construction this morning I would discuss with you to remedy any requirements of the County of PSL
building department.
If we need to provide further documentation please inform me and I will provide.
Thank you
Lou Perini
Threshold Inspector Representative / LSC
Senior Project Manager I Construction Materials
Terracon
1225 Omar Road I West Palm Beach, FL 33405 paw
l (561) 494-701510 com terrac99 I F (561) 689-59551 M (561) 248-5147 FIL
C()Py
:'-lou.perini(a)terracon.com I terracon.com
Terracon provides environmental, facilities, geotechnical, and materials consulting engineering services delivered with
responsiveness, resourcefulness, and reliability.
Joe Cicio
From:
Joe Cicio
Sent:
Tuesday, September 15, 2015 8:00 AM
To:
'Frank Smith'
Subject:
RE: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Good morning Frank,
The St Lucie Product affidavits are needed for all building cladding. The engineer would fill in all pertinent lines,
completely, for the products proposed which will include the N.O.A.#s or the Florida approval #s with the product
approvals affixed. We will need three of these signed, sealed and dated by the design professional of record. We then
will review and inspect by these documents.
http://www.stlucieco.gov/pdfs/product review aff 2014.pdf
Thank You
fed elml X&a
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
St Lucie, Co-u.vvly PL&vw,Z" a*L& De4r0-orAmt*,,fServUzP
From: Frank Smith [mailto:fsmith@castlesdesigngroup.comj
Sent: Monday, September 14, 2015 4:42 PM
To: Joe Cicio
Cc: 'Steven Pratt'
Subject: RE: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
SCANNED
BY
St. Lucie Count,
Kawneer informed me that Section F. STATEMENTS should cover the Product affidavit as these were the items needed
to approve the storefront/glazing system for the NOA.
Thank you again for all the help,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith @castle sdesigngroup.com
From: Joe Cicio [mailto:cicioi@stlucieco.org]
Sent: Monday, September 14, 2015 12:02 PM
To: 'Frank Smith' <fsmith@castlesdesigngroup.com>
Cc: Joe Cicio <cicioi@stlucieco.org>
Subject: RE: Family Dollar- Port St Lucie, FL- Permit No: 1502-0127
Good afternoon Frank,
This N.O.A 14-0430.18 will be fine as long as your design professional specifies option 1 or option 2 for the
wet glazing or option 1 for the dry glazing on plans and the drawings show the max d.l.o. on the elevations . The
engineer needs to address this within the Product affidavit . Sorry I haven't responded sooner as I was out of the office
last Thurs and Fri.
Thanks
Joe
From: Frank Smith [mailto:fsmith@castlesdesigngroup.com]
Sent: Monday, September 14, 2015 11:16 AM
To: Joe Cicio
Cc: 'Steven Pratt'
Subject: RE: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
I apologized, I haven't heard back from you regarding the storefront issue. We are moving closing to resubmitting the
project and do not want this item to be the one holding us back.
Hope you had a great weekend,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith@castlesdesigngroup.com
From: Frank Smith [mailto:fsmith@castlesdesigngroup.com]
Sent: Thursday, September 10, 2015 9:48 AM
To: Joe Cicio <cicioi@stlucieco.org>
Cc: 'Steven Pratt' <spratt@castlesdesigngroup.com>
Subject: FW: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
Thank you for the help.
We had a conversation with Kawneer in regard to the storefront system needed to use for Family Dollar— Len nard
Road/Port St Lucie, Florida project. They sent over the product information on both the glazing and storefront system
(attached) and indicated that these systems work correctly for the application and in compliance with the requirements
for the NOA compliance. I asked them to confirm the requirements for testing of the storefront with recommended
glazing approved in the NOA.
Kawneer referred me to Section F. STATEMENTS paragraph 1 which outlines the confirmation in the NOA utilized the
glazing in Section E. MATERIAL CERTIFICATIONS. Both the Storefront and the glazing have the same statement.
I did refer to your example NOA 12-1106.05 and I looked at FL# 8787-R5. FL# 8787-115 had the exact storefront system
from Kawneer I had send in the previous email (and attached).
With the attached PDF, will this be approved for our project?
Thanks,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith@castlesdesigngroup.com
From: Joe Cicio [mailto:cicioi@stlucieco.orgl
Sent: Wednesday, August 26, 2015 3:42 PM
To: 'Frank Smith' <fsmith(a)castlesdesigngroup.com>
Subject: FW: Family Dollar- Port St Lucie, FL- Permit No: 1502-0127
Frank,
Look at FL# 8787-115 to see if that helps you
Thanks
Joe
From: Joe Cicio
Sent: Wednesday, August 26, 2015 4:35 PM
To: 'Frank Smith'
Cc: Joe Cicio
Subject: RE: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Good Afternoon Frank,
We, here in St Lucie County, have adopted the Florida Building Code library and are currently enforcing the 2014
51h edition . We review the codes and manufacturers product approvals for compliance. In review of the testing you have
sent the aluminum storefront framing system would be o.k. however the other N.O.A. is for the interlayer testing only.
The notes state that the interlayer by itself does not comply with the Florida Building Code . The complete storefront
system must be engineered as 1 assembly being impact resistant. The other issue would be the design pressures as
required by your design professional.
I would need to seethe complete testing for the laminated glass w/ frames, then your engineer would put the
glass and frames together on the plans to show a complete assembly. [[[ EXAMPLE ONLY]]] see NOA 13-1106.05 as you
will see the complete assembly, glazing options, spans etc
Thank You
%"eta x
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and Two Family Plans Examiner
StLlu i CQu.wfy KamhAi" atnd. D�ServLc s,
From: Frank Smith [mailto:fsmith@castlesdesigngroup.com]
Sent: Wednesday, August 26, 2015 2:38 PM
To: Joe Cicio
Cc: 'Steven Pratt'; Igililung@castlesdesigngroup.com
Subject: Family Dollar - Port St Lucie, FL - Permit No: 1502-0127
Mr. Cicio,
I talked to our storefront supplier Kawneer about which model would work at Port St. Lucie and they directed me to
their IR 501. The storefront system calls out, as one of the options for glazing, the Saflex. As it was explained to me by
the Kawneer and the glazing provider that as a whole the storefront and glazing meets the L.M.I. rating required by the
county.
My question is, will this meet the proper county requirements?
Thanks,
FrankJ. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsmith @castlesdesigngroup.com
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and !
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and f
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
f '
Joe Cicio
From:
Joe Cicio
Sent:
Thursday, August 20, 2015 11:15 AM
To:
'Frank Smith'; 'Steven Pratt'
Cc:
Joe Cicio
Subject: _
RE: Family Dollar - Lennard Road, Port St. Lucie Permit No. 1502-0127
Good Morning Frank,
Thank you for your e-mail and feel free to e-mail"me at any time. Please see the 2010 Florida Building Code
section 1609.1.2 which addresses Protection of openings located from 0 to 30 feet above grade and openings above 30
feet from grade. Depending upon how a product has been tested would determine its use within the wall of a building.
In N.O.A. # 12-0622.06 you will see that Kawneer has tested this product as small Impact resistant and it is for
use above the 30 foot mark as stated in note 6 in the general notes. You may select to use hurricane protection on this
curtain wall if desired and this product would be fine.
Now,,, with all of that being said, you may find a test for the same product under the Florida product approval
system , esr reports or one of the other testing means welcomed by the Florida Building Code. I would contact the
manufacturer to see if they have any alternative testing. You do not have to use a NOA in this part of Florida.
Thank You
-- SCANNE
By
Plans Examiner II St. Lu0ie
Standard Building Inspector
Building Plans Examiner
One and 'I`$c Family Dwelling Inspector Py
- I Um C4 0
One and TJo Family Plans Examiner
St Luei ez Comfy PULM+A " avid SerVUZ-5,
From: Frank Smith[mailto:fsmith@castlesdesigngroup.com]
Sent: Thursday, August 20, 2015 10:08 AM
To: Joe Cicio
Cc: 'Steven Pratt'; Igililung@castlesdesigngroup.com
Subject: Family Dollar- Lennard Road, Port St. Lucie Permit No. 1502-0127
Cicio,
comments stated that the glazed curtain wall must be Large Missile rated. Can you help me with this
\the storefront we will would like to use and one of the approved glazing is attached as well. The
�e Large Missile rating but not the glazing. Can we still use these items together because the glazing is
storefront? All the other approved glazing's for the storefront couldn't be found.
t
_ fl
a
Thanks,
Frank J. Smith
Castles Design Group
3801 Kirby Drive, Suite 600
Houston, Texas 77098
p: 713.664.7974 x1312
f: 713.664.9756
fsm ith CcDcastlesdesient?rouo.com
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
-y s
VELCON GROUP, INC.
ENGINEW & SMMORS
October 29, 2015
Edmund Bas
St. Lucie County Public Works - Engineering Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Minor Site Plan Application '
Permit #1502-0127
Constructability Review - Response to Comments
Family Dollar - Lennard Road
10331 SE Lennard Road, Port St. Lucie, FL 34952
S12, T37S, R40E
Dear Mr. Bas,
SCANNc--,
BY
St. Lucie en, v
�d-OV 4 9015
We have received your constructability comments dated October 23, 2015. The following
responses correspond to the comments provided:
1.-2. Resolved.
3. We spoke with the County Engineer, Michael Powley, P.E., regarding the updated
comment requiring 18" minimum clearance. Mr. Powley stated that it was not
understood that both pipes are storm sewer. Since that is the case, he indicated that 6"I
minimum vertical clearance is acceptable. The invert of the lower pipe has been
adjusted to clearly achieve 6" minimum vertical separation.
4. The storm pipe inverts have been adjusted to clearly achieve the required cover.
5.-9. Resolved.
10. This comment was discussed directly with you during our phone conversation and th
design meets the ADA criteria as presented.
11. The compaction requirement has been added to the sidewalk detail.
12. As discussed with you during our phone conversation, no changes to the plans an
necessary.
Should you have any questions on the above, please contact our office at your earlie
convenience.
Sincerely,
Randy Rodgers, P.E.
The Velcon Group, Inc.
Attachments:
1. Construction Plans (4)
2. CD
Cc: File 12-066ENG (w/ aft)
RECEIVED
- 3 2015
ENGINEERING
N.\COMMERCIAL PROJECTS\12-JOBS\12-066 Family Dollar Lennard Road\SLC\Public Works\12-066 SLC PW 10-29-SS.doc
702 SW Port St. Lucie Blvd., - Port St. Lucie, Florida 34953 • Phone (772) 879-0477 • Fax (772) 8
1.
Lydia Galbraith
From:
Sent:
To:
Cc:
Subject:
Attachments:
Lydia,
Please see attached.
Thanks,
Edmund Bas
SLC-Engineering
Ext. 2184
Edmund Bas
Monday, November 09, 2015 10:46 AM
Lydia Galbraith
Linda Pendarvis; Ron Harris; Michael Powley; Craig Hauschild
FAMILY DOLLAR
Family Dollar Comments 110915.docx
SC BN ED
i ucie county
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
1
November 9, 2015
Project: FAMILY DOLLAR
Permit #1502-0127
Subject: REVIEW COMMENT
To: Lydia Galbraith
From: Edmund Bas
PW-Engineering Division
CONSTRUCTION PLAN:
1. On Sheet #1, please label the crosswalk pavement marking on the southeast portion of the
parking lot. Comment has been addressed.
2. On Sheet #1, please provide a Typical Section of the Stamped Concrete. Comment has been
addressed.
3. On Sheet #2, INTERFERENCE POINT #4, it seems the 6" minimum separation is not achieved.
Please verify. This comment has not been satisfied. The County Standards require 18" of clear
separation between storm pipes. Comment has been addressed.
4. On Sheet #2, Structures SO #2 and SD #3, it seems there is not enough cover height from the
top of the pipe to the bottom of the pavement base. Please refer to the FDOT Design Standards
for Cover Height requirements. This comment has NOT been satisfied. Code 7.07.02 of the
Land Development Code states that: "In addition to meeting the requirements of this Code,
the design and performances of all stormwater management systems shall comply with all
applicable regulations of the State of Florida and rules of the South Florida Water Management
District. In all cases, the strictest of the applicable standards shall apply." Please refer to FDOT
Standard Index #205 for cover height requirements. Comment has been addressed.
5. On Sheet #3, the Typical Pavement Sections do not match the Typical Pavement Sections
shown on Sheet #1. Comment has been addressed.
6. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, the overlap of the proposed
asphalt to the existing asphalt should be consistent with the ASPHALT PAVEMENT SAWCUT
& BUTT JOINT DETAIL. Comment has been addressed.
7. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, please indicate the compaction
requirements of the base and the backfill materials around the pipe. Comment has been
adressed.
8. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, General Note #1, please verify
if this requirement can be achieved with the proposed invert elevations of the pipe. Comment
has been addressed.
9. On Sheet #3, REPLACEMENT OF FLEXIBLE PAVEMENT Detail, General Notes #1, please
correct the spelling of the word "ORIGINAL". Comment has been addressed.
10. On Sheet #2, SIDEWALK CONNECTION DETAIL, the Americans with Disabilities Act (ADA)
requires that running slopes for sidewalks should not be greater than 5%. Please refer to ADA
Standards for ramps and handrail requirements. Comment has been addressed.
11. On Sheet #2, SIDEWALK PAVEMENT DETAIL, please provide the compaction requirement for
the Compacted Subgrade. Comment has been addressed.
12. On Sheet #3, SPACING OR REQUIRED ROADWAY/PARKING AREA TESTS, the County requires
Limerock Bearing Ratio (LBR) instead of Florida Bearing Value (FBV). Please remove
reference to FBV. Comment has been addressed.
�l
Joe Cicio
From: Troutner, John <jroutner@hutton.construction>
Sent: Wednesday, August 31, 2016 2:04 PM
To: Joe Cicio
Cc: Jennings, Ronnie
Subject: Contingency plan for permit # 1502-0127 / Family Dollar 10331 SE Lennard Rd Port
Sanit Lucie
v Thanks for taking my call earlier Joe, I�
In consideration of the recent storm passing over Florida, FPL has warned us (Hutton Construction) that they
may not have the man power to install a power meter at 10331 SE Lennard before our projected open date. Is
it possible to power the site by a commercial generator(s) until they are able to install the meter?
Thanks again,
John Troutner
Superintendent
Hutton Construction
(423) 702-1276
jtroutner@hutton.construction
SCANNED
BY
St. Lucie Count\,
1
�?onrsiCITY OF Rim ST. LUCIE
UTILITY SYSTEMS DEPARTMENT
,• m 900 SE Ogden Lane
Port St. Lucie, FL 34983
(772) 873-6400 — TDD Accessible
F�OgtDP (772) 871-7615 — FAX Jesus A. Merejo, Director
'A CIry)orAHAges'
August 20, 2015
Randy Rodgers
Velcon Group, Inc.
702 S.W. Port St. Lucie Blvd.
Port St. Lucie, Florida 34953
Re: Family Dollar at Lennard Road
Water and Sewer Availability
Dear Mr. Rodgers:
Via e-mail: RandvR(o)Velcongroup.com
Regarding your request dated August 20, 2015; this is to confirm that the referenced project is within
the City of Port St. Lucie Utility Systems Department service area. A public water main and a public
sewer line are adjacent to the above property.
Please be advised that water and sewer system extensions may be required to serve the
property.
This should not be construed as a commitment to provide service until approvals by all regulatory
agencies have been obtained; construction plans are approved; a Service Agreement has been fully
executed; and all applicable fees have been paid to the City of Port St. Lucie Utility Systems Department.
Should you have any questions or require additional information, please feel free to contact our office by
calling 873-6400.
Sincerely,
�
`-�.
Lisa Campbell, M.P.A.
Commercial Development Manager
c: Jesus Merejo, Director
Laney Southerly, Engineering Manager
File: 5190
PSLUSD Doc. No. 04
Florida Power & Light Company
FPL
September 9, 2015
Hutton Company
736 Cherry Street
Chattanooga, TN 37402
Re: Family Dollar
10331 SE Lennard Rd.
Port St. Lucie, FL 34952
Dear Hutton Company:
Thank you for. contacting FPL early in your planning process. This will help you to achieve
your desired schedule for your project at the above location. At the present time FPL has
service available.
Service will be provided in accordance with applicable rates, rules, and regulations.
Please provide the final site plan, site survey and electrical load as soon as possible so
that we can plan accordingly.
I look forward to developing a good working relationship with you.
Si cerely,
l I/t/wu2
Shareka Hayden
Project Manager
(772)337-7025
an FPL'Group Company