Loading...
HomeMy WebLinkAboutOBSERVATIONS REPORTSr't STRUCTURAL STEEL OBSE__ _ ATIONS REPORT Report Number: HB161005.0074 Service Date: 09/06/16 Report Date: 09/09/16 Hutton Construction, Inc. Attn: Nancy Bunch 732 Gherry Street Chattanooga, TN 37402 lrerracon 607 NW Commodity Cv Port St Lucie, FL 34986-2250 Family Dollar 10M 1 Lennard Road Port St. Lucie, FL 34952 SCANNED BY St. Lucie Countv Project Number. ,HB161005 Services Requested By: Garrett @ Hutton Construction Connection Type/Description: Structural steel metal building bolting Visual Observation Elevation(s)/Location(s): Roof rake parapet walls framing bolting, roof purlins framing & bolting Type of Observation: Structural steel Referenced Documents: Official construction documents, Mesco Building Solutions, metal building manufacturer submittal drawings, page E3 of 15, E4 of 15. Observation Results: Based on our visual observations, the connections observed at the referenced locations appeared to be the proper size, type, in the proper location and placed in general accordance with the identified referenced documents. Exceptions: 3rd re -inspection Comments: Deficiencies noted in report number 42 dated 4-27-2016 have been corrected. L Services: Terracon Rep.: Louis, Perini Reported Too Client Contractor: Hutton Construction Report Distribution: (1) Hunan Construction, Inc., (1) Platinum Construction, Inc, yalmond(aUtton.construction i3mes(?Platinumcoustruction.0m (1) St. Lucie County, cicioj@sducieco.org (1) Velcun Group, Inc, emcstov(dvelwngroup.com (1) Velcan Group, Inc, taudyrAa elcunmurp.com Reviewed By: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This indicated above and shall not be reproduced except in full without the Written consent of our company. Test re the actual samples tested at theloration(s) referenced and are not necessarily indicative of the properties of of Cr0019, 10.1613; Rev2 Page I of I SEP 1 6 RECD �s02-0/2 7 FL RegisfSHYrar on No. 44082 t is exclusfor the use of the client transmitteein are only applicable to pparentiy or identical materials. STRUCTURAL STEEL OBSI , _ ATIONS REPORT Report Number: HB161005.0042 Service Date: 04/25/16 Report Date: 04/27/16 Hutton Construction, Inc. Attn: Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 Ire racon 607 NW Commodity Cv Port St Lucie, FL 34986-2250 Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB161005 Services Requested By: Kevin O'Steen with Hutton Construction Reinforcing Steel Type: Observation Location(s): SCANNED BY St. Lucie County Observation Results: Based on our observations, the reinforcing steel placement at the above -referenced locations DID NOT APPEAR to be completed in general accordance with the identified project drawings. Please see the Exceptions for a discussion of non- conforming items. Referenced Drawings: Official construction documents, Metal building drawings section A on page 5 • Exceptions: • Parapet rake walls steel framing top channel connections missing bolts at plated connections, 2 bolts required at each connection, (6) six locations missing bolts and fastened together with tech screws. FBC 107.4 Amended Construction Document required by (DOR) designer of record of metal building before re - inspection. • Roof framing purlins concealed at time of inspection, 100% of roof standing seam panels installed, unable to verify roof panel clip connection to roof framing members holding down metal roof panels, roof insulation 100% complete, unable to verify from below roof clip connection to roof framing system. • Main roof framing support W-shape beams supported by columns missing bolts in various locations. • North, South, East, West metal building comers structural steel columns to wall girt connections missing bolts. Comments: In progress / ongoing. RECEIVED SEP 14 2016 Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Construction Report Distribution: (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, galmonl(,c Itoncooewcrion ia111es P1aVnumCnnsMcfion.org (1) St. Lucie Cowry, cicioj@rtlucieco.org (1) Velcon Group, Inc, Reviewed By: emestovpvelcongmw.cam (I) Velcon Group, Inc, rnndvr(u}vcicong=p.com FL The tests were performed in general accordance with -applicable ASTM, AASHTO, or DOT test methods. This report is indicated above and shall not be reproduced except in full without the written consent of our company. Test results trar the actual samples tested at the locallon(s) referenced and are not necessarily Indicative of the properties of other appr CNa13, 1041 13, Rc..v Pagc I of 1 ation No. 44082 ely for the use of the client herein are only applicable to milar or identical materials. STRUCTURAL STEEL OW) VATIONS REPORT Report 1-113161005.0042 I rerracon Service Date: 04/25/16 607 NW Commodity Cv Report Date: 04/27/16 Port St Lucie, FL 34986-2250 772-343-9787 Reg No: 6870 Client Project Hutton Construction, Inc. Family Dollar Attn: Nancy Bunch 10331 Lennard Road 732 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 Project Number: HB161005 Botts Services: Rake Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Construction Report Distribution: (1) Hutton ConsWction. Inc., (1) Platinum Construction; Inc, xalmond9hunon.constmction lamcsAPlafin=Cons ction.orx (1)St. Lucie County, cieioj@stluciew.org (1) Velcon Croup, Inc, cmesm avciconAMP.Mat (1) Velcon Group, Inc, randyravelcongmup.com Reviewed By: Bolts FL The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclu: Indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitte the actual samples tested at the location(s) referenced and are not necessarily indicati4e of the properties of other apparently Page 1 of 1 tNo. 44082 r the use of the client a are only applicable to or Identical materials. STRUCTURAL STEEL OBS, NATIONS REPORT Report HB161005.0042 Service Date: 04/26/16 Report Date: 64/27/16 Client Hutton Construction, Inc. Attn: Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 at Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Construction Report Distribution: (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, galmonclRbutton.constmction jamcsAPIatinumConstmction.org (1) St. Lucie County, cicioj@stlucieco.org (1) Velcon Group, Inc, emestovCmVelcongmup.com (1) Velcon Group, Inc, iandvr9velcongroup.com 1 rerracon 607 NW Commodity C Port St Lucie, FL 34986-22f 772-343-9787 Reg No: 68i Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 Number: HB161005 (Photo No.) I Bolts Missing / Roof Parapet Rake Framing Reviewed By: FL Reeishrion No. 44082 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclus ely for the use of the client Indicated above and shall not be reproduced except In full without the written consent of our company. Test results t ansmitte stein are only applicable to the actual samples tested at the locatlon(s) referenced and are not necessarily Indicative of the properties of other apparently liar or Identical materials. Page 1 of 1 STRUCTURAL STEEL OBC-i A,VATIONS REPORT Report H13161005.0042 Service Date: 04/25/16 Report Date: 04/27/16 Client Hutton Construction, Inc. Attn:Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 (Photo No.) Bolts Missing / Roof Parapet rake Framing ��.+.ffA [II[il[[annm c 1 C 'T- :IStI[IfCrt[n[numnn o Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Construction Report Distribution: lterracon 607 NW Commodity Cv Port St Lucie, FL 34986-22.50 772-343-9787 Rea No:6870 Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB161005 _seuln)r m[inumu�mm[Ir;r-, I - -, P ¢� IP (1) Hutton Construction, Ina, (I) Platinum Coasuuction, lac, galmond64M1utton.cunstrucnon lamespPletinutnConstruction.org (1) St. Luce County, dd0j@sduciwo.org (1) Velcon Group lag Reviewed By: emestovCWvelcongroup.rnm (1) Velmn Group, Inc, M1Ch111 O'COnI O[ mndyr(ijvclmngmuo-con, FLRegisionNo.44082 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclus for the use of theclient Indicated above and shall not tie reproduced except in full without the written consent of our company. Test results transmitterein are only applicable to the actual samples tested at the Iocation(s) referenced and are not necessarily Indicative of the propertles of other apparentlyar or Identical materials. Page 1 of 1 STRUCTURAL STEEL OBE :_ YATIONS REPORT Report HB161005:0042 I rerracon Service Date: 04/25/16 607 NW CommodityCv Report Date: 04/27/16 Port St Lucie, FL 34986-2250 772-343-9787 Reg No: 6870 Client Project Hutton Construction, Inc. Family Dollar Attn:Nancy Bunch 10331 Lennard Road 732 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 Project Number: HB161005 Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Construction Report Distribution: (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, 01mond(aihunun.constmction lames(a)PlatinumCooshuclion.om (1) SL Lucie county, cicioj@nlucieco.org (1) Veleon Group, Inc, Reviewed By: emesuw rAvelcommp.com (1) Velcun Group, Inc, rendyrRvelconmup.com The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is indicated above and shall not be reproduced except in full without the written consent of our company. Test results trar the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other appe Page 1 of 1 ration No. 44092 rely for the use of the client herein are only applicable to imiter or Identical materials. STRUCTURAL STEEL OBSI_--, . 'ATIONS REPORT �������� Report Number. HB161Q05.0071 Service Date: 018/24/16 607 NW Commodity Cv Report Date: 09/02/16 Port St Lucie, FL 34986-2250 772-343-9187 Reg No: 6870 Client Project SCANNILL Hutton Construction, Inc. Family Dollar BY Attn: Nancy Bunch 10331 Lennard Road 7.32 Cherry Street Port St. Lucie, FL 34952 �¢• Lucie C011ntt Chattanooga, TN 37402 ProiectNumber' IM161005 Services Requested By: Garrett Almond Connection Type/Description: Roof Panel Fasteners / Dry In Visual Observation Ele,vation(s)/Location(s): Metal standing seam crimp roof panels Type of Observation: Structural steel metal building Referenced Documents: Official construction documents Observation Results: Based on our visual observations, the connections observed at the referenced locations appeared to be the proper size, type, in the proper location and placed in general accordance with the identified referenced documents. Exceptions: NA Comments: NA Services: Terracon Rep.: Louis, Perini Reported To: Contractor: Hutton Report Distribution: (1) Hutton Construction, Inc., ualmond b4gon.conmuction (1) St. Lucie County, cicioj@stlucimo.org (1) Velcon Croup, Inc, renayr(alvelcon¢row-cm (1) Platinum Construction, Inc, jinuo(a)PlatinumComouction.orz (1) Velcon Croup, Inc, ..stovQvelconmup.cotn Reviewed By: FL The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclu: indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitte the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently Cr11019, 10-I&D, Rev2 Page I of I SEP 1 6 RECD No.44082 the use of the client are. only applicable to r identical materials. STRUCTURAL STEEL OBE; MATIONS REPORT Report HB161005.0071 Service Date: 08/24/16 Report Date: 09/02/16 Client Hutton Construction, Inc. Attn: Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 r a Photo No.1 Roof panels fasteners dry in 1 rerracon 601 NIN Commodity CV Port St Lucie, FL 34986-2250 772-343-9787 Reg No: 6870 Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 HB161005 Photo No. No. 4 - Roof panel fasteners dry in 9 Services: l Terracon Rep.: Louis, Perini Reported To: Contractor: Hutton Report Distribution: (1) Hutton Con=c idn, htc., (1) Platinum Construction, Inc, gahnond(a?hutton.conshuction iamesgPlatinumConstruction.org (I) St. Lucie Cmmty, cicnq@sduci«o.org (1) Velcon Group, Inc: Reviewed By: emcstovAvcicongouo.com (1) Velcun Group, Inc, - - mndyaiilvcicocWo .corn FL Regis "on No082 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusiv for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted rein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently sit iar or identical materials. Page 1 of 1 I i STRUCTURAL STEEL OBE , -IfATIONS REPORT l ��rr�con Report HB161065:0074 Service Dater 09/06/16 607 NW Commodity Cv Report Date: 09/09/16 Port St Lucie, FL 34986-2250 772-343-9787 Reg No:6870 Client Hutton construction, Inc. SCANNED Project Family Dollar Attn:Nancy Bunch BY 10331 Lennard Road 732 Cherty Street St. Lucie County Port St. Lucie, FL 34952 Chattanooga; TN 37402 Project Number. HB16.1005. Photo No. 1 Roof rake parapet wall corrected bolted connections; 9-62616 Roof rake parapet wall Photo No. 3 connections, 9-6-2016 Roof rake parapet wall corrected bolted Photo No. 2 connections, 9-6-2016 Roof rake parapet wall corrected bolted " Photo No. 4 connections, 9-6-2016 Services: Terracon Rep.: Louis, Perini ` Reported To: Client Contractor: Hutton Construction Report Distribution: (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, galmond@hutton.consttucdon james@Platimanconsumcnon.mg (1)St. Lucia County, cicioj@sducieco.org (1)Velcon Group,Inc, R¢VI¢W¢d By: ttnestov�t{velcongouD.com (1) Velcon Group, Inc, randyr@velconmup.com FL The tests were performed in general accordance with applicable ASTM, AASHTO; or DOT test methods. This report is indicated above and shall not be reproduced except in full without the written consent of our company. Test results tran the actual "samples tested at the location(s) referenced and are hot necessarily indicative of the properties of other appa Page 1 of 2 INo. 44082 r the use of the client rare only applicable to or identical materials. STRUCTURAL STEEL OBSI. 'ATIONS REPORT Report Number: HB161005.0073 Service Date: 09/01/16 Report Date: 09/09/16 Hutton Construction, Inc. Attn: Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 SCANNED BY St. Lucie County 1 rerracon 607 NW Commodity Cv Port St Lucie, FL 34986-2250 772-343-9787 Reg No: 6870 _ Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB161005 Services Requested By: Garrett @ Hutton Connection Type/Description: Metal Building Bolting Visual Observation Elevation(s)/Location(s): Parapet walls framing bolted connections Type of Observation: Structural steel Referenced Documents: Official construction documents Observation Results: Based on out visual observations, the connections observed today DID NOT APPEAR to be placed in general accordance with the identified referenced documents. As a result, the observation is noted as Non -Conforming. Exceptions: Re -inspection to verify roof parapet wall framing & bolting deficiencies noted in report dated 4-27-16, report number 42. See attached photographs. Comments: No deficiencies corrected as detailed on report number 42, dated 4-27-2016. Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Report Distribution: (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, � gahaond(a7,hutton.construction iames(olPlatirunConsnuctiomorx (1) st Lucie Comity, cicioj@stlucieco.org (I) Velcon Group, lnc, Reviewed By: emestov@velconxroup.com (1) Velcon Group, Inc, raudyr@velcotutroup.com FL The tests were performed in general accordance with applicable ASTM; AASHTO, or DOT test methods. This report is indicated above and shall not be reproduced except in full without the written. consent of our company. Test results her the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other appe Cr0019,161613,Rev.2 Page I oft SEP 1 6 REC'D wion No. 44082 ely for the use of the client herein are only applicable to milar or Identical materials. .ti STRUCTURAL STEEL OB4---__VATIONS REPORT ��������� Report HB161005:0073 Service Date: 09/01/16 607 NW Commodity Cv Report Date: 09/09/16 Port St Lucie, FL 34986-2250 772-349-9787 Reg No:6870 Client Project Hutton Construction, Inc. Family Dollar Attn: Nancy Bunch 10331 Lennard Road 732 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 Project Number. HB161005 V _ y Photo No.1 Rake parapet wall metal framing bolts missing, not per plan. Photo No. 3 Services: pPhotoNo.2 i Rake. parapet wall metal framing bolts missing, not per plans. Terracon Rep.: Louis, Perini Reported To: Client Contractor: Report Distribution: (1) Huttou Construction, Inc., (1) platinum Conshuction, Inc, olmondphunon.wnstmction jamcs(a?PlatinumConstruction.org (1)StLucm County, nigriucieco.org (1) Velcon Group, Inc. Reviewed By: emestovftvelcongroup.com (1) Velcan Group, Inc, ], O'COIlnO randvrra�velcongoup.wm FL Regis ation No. 44082 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclus' I ly for the use of the client Indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitte erein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently ilar or identical materials. Page 1 of 1 STRUCTURAL STEEL OBSI= "ATIONS REPORT 7 F�rr�con Report Number: HB161005.0070 Service Date: 08/24/16 607 NW Commodity Cv Report Date: 09/02/16 Port St Lucid, FL 34986-2250 772-343-9787 Reg No: 6870 . Client Project Hutton Construction, Inc. SCANNED Family Dollar Attn: Nancy Bunch BY 10331 Leonard Road 732 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 St. LUCID. Cnunty Project Number: HB161005 Services Requested By: Garrett Almond Connection Type/Description: Structural Steel Metal Wall Panels Fasteners Visual Observation Elevation(s)/Lodation(s): Exterior North, South East West, Parapet walls. Type of Observation: Structural Steel Metal Building Components Referenced Documents: Official construction documents permit set. Observation Results: Based on our visual observations, the connections observed at the referenced locations appeared to be the proper size, type, in the proper location and placed in general accordance with the identified referenced documents. Exceptions: NA Comments: NA Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Report Distribution: (1) Hutton Construction, Inc., r1mond inigon.construction (1) St. Lucie Cowty, cicioj@sducieco.org (1) Velcon Group, Inc, mndYK4velcon=up.com (1) Platinum Construction, Inc, iamesAPlafiniunConswction.org (1) Velcon Group, Inc, - Reviewed By: emestovAvelconmoup.com FL 5EP 1 6 OECD The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclu: Indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitte the actual samples tested at the location(s) referenced and are not necessarily indicative of the.properties of other apparently Cfa019,1 &D, Irevl Page 1 of 1 1 No. 44082 r the use of the client 1 are only applicable to or identical materials. STRUCTURAL STEEL OB;,,� _,VATIONS REPORT Report HB161005.0070 Service Date: 08/24/16 Report Date: 09/02/16 Hutton Construction, Inc. Attn: Nancy Bunch 732 Cherry Street Chattanooga, TN 37402 Services: Terracon Rep.: Louis, Perini Reported To: Client Contractor: Hutton Report Distribution: Irerracon 607 NW Commodity Cv Port St Lucie. FL 34986-2250 Project Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 Project Number. HB161005 (1) Hutton Construction, Inc., (1) Platinum Construction, Inc, galmwd(alutlon.cons"etion jumes(dPlatinumCarmuction.org (I) St Lucie County, cicioj(av)stlucimo.org (1) Velcon Group, Inc, Reviewed By: emestovielvcleonguaga.eom (1) Velcon Group, Inc, sandwAvelcanpmw.com FL Regi tration No. 44082 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exGu iv y for the use of the client Indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitte rein are only applicable to the actual samples tested at the locations) referenced and are not necessarily Indicative of the properties of other apparenlly Her or Identical materials. Page 1 of 1 EARTHWORK OBSERVATIOP� ~--PORT Report Number: HB161005.0020 Service Date: 03/08/1 Report Date: 03/08/1 LE2 C 12 0 V pp I Client v Hutton Construction, Inc. MAR 9 Ui Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 _AZ_ I RECEV.'D j�:. : 0 '116 1 rerracon 607 NW Commodity Cv Port St Lucie, FL 34986-2250 Project Family Dollar SCANNED 10331 Leonard Road BY Port St. Lucie, FL 34952 St. Lucie Countv ProiectNumber: FIB161005 Summary of Earthwork Observations and Density Testing for the Building Pad: This summarizes the earthwork observations and density testing during the preparation of the building pad for the proposed Family Dollar at 10331 Lennard Road in Port St. Lucie, FL. The earthwork was performed between February 3rd and March 71h, 2016. Our on -site contact was Kevin O'Steen with Hutton Construction. Our field personnel typically discussed the daily earthwork activities with Kevin and provided verbal results of the daily observations and testing. As outlined in the Geotechnical Engineering Services Report prepared by KCI Technologies (KCI), dated November 19, 2012, there was uncontrolled fill and buried debris that need to be removed from the building pad area and replaced with compacted embankment fill. At the time of our initial observations it appeared that some of the uncontrolled fill had been removed from the building pad area.'The site contractor utilized a large trackhoe to excavate about 8 to 8 1/z feet of uncontrolled fill and buried debris from the building pad. Based on the survey .stakes in the field (by others), the building excavation was oversized approximately 10 feet beyond the building footprint. The bottom of the excavation ranged from approximate elevation +8 NAVD in the NW corner of the excavation to about elevation +9- NAVD along the east side of the excavation (see attached sketch). The soils encountered at the excavation bottom consisted of a poorly graded gray to light gray fine to medium grained sand that were judged to be native soils. A dozer was used to level the excavation bottom and push the standing water to the lowest point (NW corner) of the excavation. The contractorused pumps to dewater the excavation bottom. A large vibratory smooth' drum roller used to surface compact the. soils at the excavation bottom prior to embankment fill placement. The embankment fill was relatively clean sand with less than 10% fines imported from another site consisting of gray and brown fine to medium sand. The fill was hauled to the site with double -axle dump trucks and placed in thin, uniform lifts about 1-foot thick with a dozer then compacted with the large vibratory smooth drum roller. In - place density tests.were taken as each lift of embankment fill in the building pad area. A total of thirty (30) density tests were performed, all tests met or exceeded the density requirement of 95% Modified Proctor density (ASTM D 1557). Based on our observations and testing, the earthwork to prepare, the building pad was completed in general accordance with the project plans and specifications. The daily earthwork observation reports, laboratory Proctor test reports and in -place density test reports have been previously submitted. As requested, original signed and sealed reports will be delivered to Mr. Joe Cicio with the St. Lucie County Building Inspection Department. ­11 F 0 PY ILL 06 Services: Turbidity measurement readings performed in the field at the locations indicated. TerraconRep.: David T. Youngstrom . Reported To: Client Contractor: Platinum Report Distribution: (I) Huaon Construction, Inc., Emailed (1) St Lucie County, cicioiCastlucieco.org Reviewed By: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exc t ely for the use of the client indicated above and shall not be'reproduced except in full without the written consent of our company. Test results transmi hereinare only applicable to the actual samples tested.at the location(s) referenced and are not necessarily indicative of the properties of other apparenimilar or identical materials. AFONZ 10.16-13, Re 3 Page 1 of 1 ° W/ 5' HIGH MASONRY WALLS 6 OPAQUE GATES (SEE DETAIL) Iq +81n In PROP. +9 (6) BIKE SPACES - 16' 81.92'7LL.0AbING— b+8 WALL PACKMOUNTED ATE 11.5' ABOVE FFE (TYP.) PAVEMENT PROP. (TYP') 1-STORY CBS DISCOUNT STORE 0 GROSS FLOOR AREA = 8,593 S.F. F.F.E. = 15.25 N.A.V.D.1988 0 +9 PROP. WATER SERVICE 'F9 a D BLDG. SEWER od m . PROP o. PAVT.. w Excavation Sketch Site Plan: N/A - Hutton Construction, Inc. ReportNumber: HB361005.0020 Attn: Lucas Borneman Technician: Jerry Logan 607 NW Commodity Cv 736 Cherry Street Date: 03/08/16 Port St Lucie, FL 34986-2250 - Chattanooga, TN 37402 Scale: Not to Scale 772-343-9787 Reg No: 6870 U 020, M&v, Re .O FIELD DENSITY TEST REPOR'_ - ,� rL'���COr Report Number: HB161005.0009 Service Date: 02/22/16 607 NW Commodity Cv ReportDate: 02/25/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Reg No: 6870 Client Hutton Construction, Inc. Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 Project Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB161005 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab -Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (pcf) (%) (%) 1 HB161005.0003 Grey fine to medium SAND, trace ASTM D1557 11:8 104.2 N/A Min 95 silt ' 2 HB 161005.0002 Grey fine to medium SAND, trace ASTM D 1557 13.2 110.5 N/A Min 95 clay & shell Field Test Data Probe Wet Water Water - Dry Percent Test Lift/ Mat. Depth Density Content Content Density Compaction No. Test Location Elev. No.' (in) (pcf) (pcf) (%) (pcf) (%) Building Pad, Excavation Subgrade SE Comer of Pad 10.50 2 0-12 123.1 14.7 13.6 108.4 98 NE Comer of Pad 9.50 2 0-12 125.4 15.6 14.2 109.8 99 Center of Pad 10.00 1 0-12 114.8 13.4 13.2 101.4 97 Datum: NAVD Serial No: 36817 Stal. Cut. M:723 Std. Cut. D: 1931 Comments: Test and/or retest results on this report meet project requirements as noted above. Test and/or retest results on this report meet project requirements as noted above. The western 1/3 of the building excavation subgrade was still too wet to take density tests. .. Services: Perform in -place density tests to determine degree of compact Terracon Rep.: Jerry Logan Reported To: Client Contractor:- Platimum Report Distribution: (I) Hutton Construction, Inc., Emailed . Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT indicated above and shall not be reproduced except in full without the written consent of ou actual samples tested at the Iocaflon(s) referenced and are not necessarily indicative of the CaeoOr, 1-W12, Re 3 - Page I of I FIELD DENSITY TEST REPORr - 1rerracon Report Number: 1-IB161005.0011 Service Date: 02/27/16 607 NW Commodity Cv Report Date: 03/04/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Reg No: 6870 Client Hutton Construction, Inc. Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 Project Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 Project Number: HB161005 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (pef) (%) (%) 1 HB161005.0003 Grey fine to medium SAND, trace ASTM D1557 11.8 104.2 N/A Min 98 silt Field Test Data Probe Wet Water Test Lift / Mat. Depth Density Content No. Test Location Elev. No. (in) (pcf) (pef) Water Content (%) Dry Density (pcf) Percent Compaction (%) Building Pad, Embankment Fill 1 SE Comer of Building Pad 11.00 1 12 117.1 14.0 13.6 103.1 99 Excavation Datum: NAVE) Serial No: 36817 Std. Cnt. M:722 Std. Cut. D: 1931 Comments: Test and/or retest results on this report meet project requirements as noted above. Test and/or retest results on this report meet project requirements as noted above. Services: Perform in -place density tests to determine degree of compacti Terracon Rep.: Jerry Logan Reported To: Client Contractor: Platinum - Report Distribution: .: (1) Hutton Construction, Inc., Entailed Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT t indicated above and shall not be reproduced except in full without the written consent of our actual samples tested at the location(s) referenced and are not necessarily indicative of the CR0001, 11-1&12, Ra 3 Page 1 of 1 FIELD DENSITY TEST REPORT: 1 rerracon Report Number: HB161005.0014 Service Date: 02/29/16 607 NW Commodity Cv Report Date: 03/07/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Reg No: 6870 Client Project Hutton Construction, Inc. Family Dollar Attn: Lucas Bomeman 10331 Lennard Road 736 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 Project Number: HB161005 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (pef) (%) (%) 1 HB161005.0003 Grey fine to medium SAND, trace ASTM D1557 11.8 104.2 N/A Min 98 silt 2 HB161005.0007 Brown fine to medium SAND, trace ASTM D1557 11.8 111.0 N/A Min 98 silt Field Test Data Probe Wet Water Water Dry Percent Test Lift! Mat. Depth Density Content Content Density Compaction No. Test Location Elev. No. (in) (pcf) (pef) (%) (pcf) (%) Building Pad, Embankment Fill 1 NW Comer of Building Pad 11.00 1 12 119.2 15.9 15.4 103.3 99 Excavation 2 SW Comer of Building Pad 11.00 1 12 118.8 15.2 14.7 103.6 99 Excavation 3 SE Comer of Building Pad 11.00 1 12 119.3 15.4 14.8 103.9 100 Excavation 4 NE Comer of Building Pad 11.00 1 12 118.2 15.5 15.1 102.7 99 Excavation 5 Center of Building Pad, South 11.00 1 12 118.5 15.9 15.5 102.6 98 Side 6 Center of Building Pad, North 11.00 1 12 118.2 15.4 15.0 102.8 99 Side 7 NE Corner of Building Pad 12.00 2 12 125.5 14.7 13.3 110.8 100 8 NW Comer of Building Pad 12.00 2 12 123.8 12.9 11.6 110.9 100 -9--SE"Comer -99 10 SW Corner of Building Pad 12.00 2 12 124:3 13.6 12.3 110.7 100 11 Center of Building Pad . 12.00 2 12 124.9 12.3 10.9 112.6 100+ Datum: N"D Serial No: 36817 Slid. Cut. M:716 Std. Cut. D: 1913 Comments: Test and/or retest results on this report meet project requirements as noted above. Test and/or retest results on this report meet project requirements as noted above. I The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods - port is exciusivelyfor the use of the client Indicated above and shall not be reproduced except in full without the written consent of our company. r Its transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties o othe pparently similar or identical materials. CR0009, I I-I6-12, Rev.] Page 1 of 2 2� 8 -;4( 4 FIELD DENSITY TEST REPOK. "I erracon Report Number: HB161005.0014 Service Date: 02/29/16 607 NW Commodity'Cv Report Date: 03/07/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Rea No:6870 Client Project Hutton Construction, Inc. Attn: Lucas Borneman 736 Cherry Street Chattanooga, TN 37402 Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB 161005 Services: Perform in -place density tests to determine degree of compaction and material Terracon Rep.: Jerry Logan - - - - - Reported To: Contractor: Platinum Report Distribution: (1) Hutton Construction, Inc., Emailed (1)St. Lucie County, cicioj@silucieco.org Reviewed By: Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. indicated above and shall not be reproduced except in full without the written consent of our company. Te actual samples tested at the location(s) referenced and are not necessarily indicative of the properties Of othe ca000r, a-1&I3, acaa Page 2 of 2 i . 'b / - ly for the used I�he client fitted herein are only applicable to the similar or identical materials. FIELD DENSITY TEST REPOR`. I rerracon Report Number: H13161005.0017 Service Date: 03/02/16 607 NW Commodity Cv Report Date: 03/07/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Reg No: 6870 Client Hutton Construction, Inc. Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 Project Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 Project Number: HB 161005 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (Pei) (%) (%) I HB 161005.0007 Brown fine to medium SAND, trace ASTM D 1557 11.8 111.0 N/A Min 98 silt, Field Test Data Probe Wet Water Water Dry Percent Test Lift/ Mat. Depth Density Content Content Density Compaction No. Test Location Elev. No. (in) (Pei) (Pei) (%) (Pei) (%) Building Pad, Embankment Fill 1 NW Comer of Building Pad 13.00 1 12 129.5 14.5 12.6 115.0 100+ 2 SW Comer of Building Pad 13.00 1 12 127.2 14.4 12.8 112.8 100+ 3 SE Comer of Building Pad 13.00 1 12 126.8 15.4 13.8 111.4 100 4 NE Comer of Building Pad 13.00 1 12 128.3 15.3 13.5 113.0 100+ 5 Center of Building Pad 13.00 1 12 125.3 15.1 13.7 110.2 99 Datum: NAVD Serial No: 36817 Std. Cut. M:715 Std. Cut. D: 1927 Comments: Test and/or retest results on this report meet protect requirements as noted above. Test and/or retest results on this report meet project requirements as noted above. Are OServices: Perform in -place density tests to determine degree of compaction and material MendNN 44082 Terracon Rep.: Jerry Logan s Reported To: STATE OF = Contractor: Platinum Report Distribution: (1) Hutton Construction, Inc., Emailed (I) St. Lucie County, cicioj@sducieco.org Reviewed By: �t r F R�b3LL4�L'11at�io.44082 Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. s e J_ (ivvel he use�the client Indicated above and shall not be reproduced except in full without the written consent of our company. T s t nsmitted""herein are only applicable to the actual samples tested at the location(s) referenced and are, not necessarily indicative of the properties of o er a barently similar or identical materials. Ca0007, a.141Y. aevv Page 1 of I 1� FIELD DENSITY TEST REPOR': •' � �C'��c7.COr1 Report Number: HB161005.0019 Service Date: 03/07/16 607 NW Commodity Cv Report Date: 03/08/16 Port St Lucie, FL 34986-2250 Task: 772-343-9787 Reg No: 6870 Client Hutton Construction, Inc. Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 Project Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 Number: HB161005 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (PC') (%) (ova) 1 HB161005.0007 Brown fine to medium SAND, trace ASTM D1557 11.8 111.0 N/A Min 98 silt Field Test Data Probe Wet Water Water Dry Percent Test Lift / Mat. Depth Density Content Content Density Compaction No. Test Location Elev. No. - (in) (pcf) (pcf) (%) (pcf) (%) Building Pad, Embankment Fill 1 NE Comer of Building Pad 14.00 1 12 125.3 13.7 12.3 111.6 100+ 2 NW Comer of Building Pad 14.00 1 12 124.9 12.2 10.8 112.7 100+ 3 SE Corner of Building Pad 14.00 1 12 123.4 11.3 10.1 112.1 100+ 4 SW Comer of Building Pad 14.00 1 12 125.5 12.3 10.9 113.2 100+ 5 Center of Building Pad 14.00 1 12 126.2 12.3 10.8 113.9 100+ 6 NE Comet of Building Pad 15.00 1 12 124.0 11.3 10.0 112.7 100+ 7 NW Comer of Building Pad 15.00 1 12 127.8 13.0 11.3 114.8 100+ 8 SE Comer of Building Pad 15.00 1 12 125.4 12.3 10.9 113.1 100+ 9 SW Comer of Building Pad 15.00. 1 12 128.1 12.3 10.6 115.8 100+ 10 1 Center of Building Pad 15.00 1 12 126.9 12.4 10.8 114.5 100+ Datum: NAVD Serial No: 36817 Comments: Test and/or retest results on this report meet project reqt Test and/or retest results on this report meet project requirem tents as noted : as.noted above. Std. Cut. M:714 Std. Cut. D: 1956 Services: Perform in -place density tests to determine degree of compaction and material moisture condition.' Terracon Rep.: Jerry Logan Reported To: Client Contractor: Platinum Report Distribution: Reviewed B (1) Hutton Conswction, Inc., Entailed (1) St. Lucie County, ciciolQsducieco.urg 1' Test Methods: ASTM D6938 -o (to The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repor¢is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-1&12, Rev.] Page 1 of I ' ReportNumber: HB161005.0002 Service Date: 02/01/16 Report Date: 02/05/16 Hutton Construction, Inc. Attn: Lucas Borneman 736 Cherry Street Chattanooga, TN 37402 Material Information Source of Material: Existing Material Proposed Use: Embankment Fill Laboratory Test Data Test Procedure: ASTM D1557 Test Method: Method Sample Preparation: Dry Rammer Type: Mechanical Maximum Dry Unit Weight (pep: 110.5 Optimum Water Content (%): 13.2 Comments: 1 rerracon 607 NW Commodity Cove Port St. Lucie, FL 34986 772-343-9787 Reg No: 6870 Family Dollar 10331 Leonard Road Port St. Lucie, FL 34952 ProjectNumbet BB161005 Sample Information Sample Date: 02/01/16 Sampled By: Michael Cohen Sample Location: Center of building pad Sample Description: Grey fine to medium SAND, trace clay & shell Result Specifications Liquid Limit: N/A Plastic Limit: N/A Plasticity Index: N/A In -Place Moisture (%): Passing #200 (%): 5.6 USCS: SP Zero Air Volds CurveforAssumed Specific Gravity 2.65 m' A T A A In N 11 13 IA IS 1B 17 IA IQ 'NI 11 9J 9 Water Content (%) Services: Proctor Test: Sample from project site which was delivered to laboratory on Service Date. sample for Moisture Density Relationship. Terracon Rep.: Armindo Gonzalez Reported To:. Client Contractor: Eddie Huggins Report Distribution: (1) Hutton Construction, Inc., Emailed Reviewed By: SF N0.44082 Test Methods: The tests were performed in general accordance with applicable ASTM, at methods. This report is exclusively for the use of , the client indicated above and shall not be reproduced except in full withou Hen consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) reference n re It nec�sari i tiye of the properties of other apparently similar or identical materials. / / /p ae000Q tatal3,Ra.J Page 1 of 1 Report Number: HB161005.0003 Service Date: 02/01/16 Report Date: 02/05/16 Client Hutton Construction, Inc. Attn: Lucas Bomeman 736 Cherry Street Chattanooga, TN 37402 Family Dollar 10331 Lennard Road Port St. Lucie, FL 34952 1rerracon 607 NW Commodity Cove Port St. Lucie, FL 34986 772-343-9787 Reg No: 6870 ProjectNumbei BB161005 Material Information Sample Information Source of Material: On -site Material Sample Date: 02/01/16 Proposed Use: Compacted Subgrade Sampled By: Michael Cohen Sample Location: On -site Stockpile Laboratory Test Data Test Procedure: ASTM D1557 Test Method: Method Sample Preparation: Dry Rammer Type: Mechanical Maximum Dry Unit Weight (pet): 104.2 Optimum Water Content (%): 11.8 Comments: Sample Description: Grey fine to medium SAND, trace silt Result Specifications Liquid Limit: N/A Plastic Limit: N/A Plasticity Index: N/A In -Place Moisture Passing #200 (%): 5.3 USCS: SP Zero Airvolds Curvefor Assumed Specific ,Gravity 2.65 . . 5 6 7 8 9 161112131415161718192D21222324 Water Content (%) Services: Proctor Test: Sample from project site which was delivered to laboratory on Service Date. sample for Moisture Density Relationship. Terracon Rep.: Anders Youngstrom Reported To: Client Contractor: Eddie Huggins Report Distribution: (1) Hutton Consmcdon, Inc., Entailed J��;'�No.44082 STATE OF dewed B :01Y 5"o._�__ ez� FL Aeeistration No. 44082 Test Methods: The tests were performed in general accordance with applicable ASTM, MSHTO ids. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the w co sent of our company. Test results transmitted herein are only applicable to the actual samples tested at the locations) referenced and a not cessarily indicative of the properties of other apparently similar or identical materials. w Ih 1 cg0005, tat5-t3,xes.7 Page 1 of 1 Zi (y[, I/l`(^/ LABORATORY COMPACTION _ MACTERISTICS OF SOIL REPOF' - ��rracon Report Number: HB161005.0007 Service Date: 02/22/16 607NW CommodityCv Report Date: 02/26/16 Port St Lucie, FL 34986-2250 772-343-9787 Reg No: 6870 Client Project Hutton Construction, Inc. Family Dollar Attn: Lucas Bomeman 10331 Lennard Road 736 Cherry Street Port St. Lucie, FL 34952 Chattanooga, TN 37402 ProjectNumbet HB161005 Material Information Sample Information Source of Material: Imported Fill Sample Date: 02/22/16 Sample Time: 1030 Proposed Use: Embankment Sampled By: Jerry Logan Sample Location: Northside Stockpile Laboratory Test Data Test Procedure: ASTM D1557 Test Method: Method D Sample Preparation: Dry RammerType: Mechanical Maximum Dry Unit Weight (pep: 111.0 Optimum. Water Content (%): 11.8 Comments: Sample Description: Brown fine to medium SAND, trace silt Result Specifications Liquid Limit: N/A Plastic Lim(t: N/A Plasticity Index: N/A In -Place Moisture (%): Passing #200 (%): 4.0 USCS: SP Zero Air Volds Curve for Assumed Specilic Gravity 2.65 3 u „z a m t rn no 3 109 c 108 r ,or 106 A ] G a in „ I, Iq ,d 19 to 11 1N 19 Water Content (%) Services: Proctor Test: Sample from project site which was delivered to laboratory on Service Date. sample for Moisture Density Relationship. Terracon Rep.: Anders Youngstrom Reported To: Client Contractor: Platimum Report Distribution: (1) Hutton Construction, Inc., Emailcd OF FLIIegistration No.44082 Test Methods: The tests were performed in general accordance with applicable ASTM, AASHT , r t s. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the 1 ant of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and a not I cessarily indicative of the properties of other apparently similar or identical materials. �O _ / CRa006, 14[6U;Rn�] Page 1 of 1 3 `g � ��',/1/.1