HomeMy WebLinkAboutDESIGN CALCULATIONS� . EasySeats --' „ 4 easyseals.conn DESIGN CALCULATIONS FOR A UNLIMITED CELLULAR WALL -MOUNTED SIGNS 8290 South U.S. i — Port St Lucie qr'A GENERAL NOTES: 1. Design is in accordance with the 2010 Florida Building Code for use QPY and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) must be capable of supporting the loaded system as verified by building department or architect/ engineer of record. No warranty, either expressed or implied, is contained herein 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2005 Aluminum Design Manual, Part 1A. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. SCANNED St. LucieY County Index: Pg 1 Cover Pg2 Wind Loads Pg 3 Anchors to Cabinet Pg 4 Anchors to Fascia Engineer's signature and seal valid for pages 1 through Christian La Easy Seals PE # 67382 th q 29531 N Federal Hwy, N200 Easy Seals .com Page 1 Bocaoca Raton, FL 33432 ySeals ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 170 mph Basic wind speed Exposure C Calculations a=9.5 3-sec gust speed power law exponent zg = 900, Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff CALCULATIONS F( WALL -MOUNTED SIGNS ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionality factor Kzt = 1.0 Topographic factor A = 10 sq ft Tributary area 1fy mpll - GAM � - WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER HEIGHT (Zone 4) (Zone 5) Y % U y - 15 ft 35.2 psf 44.8 psf 0.85 53.4 -1.10 -1.40 20 ft 37.4 psf 47.6 psf 0.90 56.7 -1.10 -1.40 25 ft 39.2 psf 49.9 psf 0.95 59.4 -1.10 -1.40 30 ft 40.8 psf 51.9 psf 0.98 61.8 -1.10 -1.40 35 ft 42.1 psf 53.6 psf 1.01 63.8 -1.10 - -1.40 40 ft 43.3 psf 55.1 psf 1.04 65.6 -1.10 -1.40 45 ft 44.4 psf 56.5 psf 1.07 67:3 -1.10 -1.40 50 ft 45.4 psf 57.8 psf 1.09 68.8 -1.10 -1.40 55 ft 46.3 psf 58.9 psf 1.12 70.2 -1.10 -1.40 60 ft 47.2 psf 60.0 psf 1.14 71.5 -1.10 -1.40 70 ft 39.9 psf 79.7 psf 1.17 73.8 -0.90 -1.80 80 ft 41.0 psf 82.0 psf 1.21 75.9 -0.90 -1.80 90 ft 42.0 psf 84.1 psf 1.24 77.8 -0.90 -1.80 100 ft 43.0 psf 86.0 psf 1.27 79.6 -0.90 -1.80 110 ft 43.8 psf 87.7 psf 1.29 81.2 -0.90 -1.80 120 ft 44.7 psf 89.3 psf 1.32 82.7 -0.90 -1.80 130 ft 45.4 psf 90.8 psf 1.34 84.1 -0.90 -1.80 140 ft 46.2 psf 92.3 psf 1.36 85.4 -0.90 -1.80 150 ft 46.8 psf 93.6 psf 1.38 86.7 -0.90 -1.80 175 ft 48.4 psf : 96.7 psf 1.42 89.5 -0.90 -1.80 200 ft 49.7 psf 99.5 psf 1.46 92.1 -0.90 -1.80 250 ft 52.1 psf 104.2 psf 1.53 96.5 -0.90 -1.80 a - of Page 2 EasySeals Wall Sign Anchor Design Structure Dimensions & loading Design wind pressure: Sign type: Sign size: Wall material: Anchor type/size: CALCULATIONS FI WALL -MOUNTED SIGNS CABINET TO BRACKETS P = 51.9 psf Cabinet A = 18.0 sgft (entire cabinet) Metal Steel studs or extrusions/shapes #14 SMS Ref: Min 18ga studs (grd 33) or 0.090" 6063-T6 Min Embedment: Full Min edge dist: 0.75" Min Spacing: 0.5" Anchor tensile capacity: Tcap = 152.0 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 934 lb ... = P*A (entire cabinet) No. of anchors req'd: n = 6.1 total anchors ... = Rt/Tcap Total anchors required: 7 total anchors balanced over cabinet OK, use min (8) total. Page 3 w�_vSeaLs Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: CALCULATIONS F WALL -MOUNTED SIGNS P = 51.9 psf Cabinet A= 18.0 sgft (entire cabinet) BRACKET TO WOOD FASCIA Wall material: Wood CDX or equiv, thickness to match Min Embed Anchor type/size: 3/8" Toggle Bolt (r) Ref: Powers Toggle Bolt, catalog Min Embedment: 0.5" Min edge dist: 3" Min Spacing: 1.5" Anchor tensile capacity: Tcap = 177.5 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 934 lb ... = P•A (entire cabinet) No. of anchors req'd: n = 5.3 total anchors ... = Rt/Tcap Total anchors required: 6 total anchors balanced over cabinet OK, critical anchor option shown. ��'�' `�a • •t Page 4